Labshake search
Citations for Beckman :
201 - 250 of 2057 citations for 6H 1 3 Thiazin 6 one 2 ethoxy 4 hydroxy 5 nitro 9CI since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
Adaptive translational pausing is a hallmark of the cellular response to severe environmental stressbioRxiv - Molecular Biology 2020Quote: ... and centrifuged at 4°C at 31,000 rpm for 2 h and 30 min using an SW 32 Ti rotor(Beckman Coulter, 369694). The gradients were fractionated using a Teledyne ISCO Density Gradient Fractionation System and 12 fractions were collected ...
-
bioRxiv - Cancer Biology 2019Quote: ... Gradients were ultra-centrifuged at 221,600 × g for 2 hours at 4°C (SW-41Ti rotor, 331362, Beckman Coulter, Brea, CA). Gradients were fractionated (Piston Fractionator ...
-
bioRxiv - Immunology 2021Quote: ... Samples were spun at 76,650 x g for 2 hours at 4° C inside a SW 32i rotor using an Optima L-90K Ultracentrifuge (Beckman Coulter). Purified virus was quantified using a bicinchoninic acid assay (BCA ...
-
bioRxiv - Genomics 2021Quote: ... The samples were then centrifuged at 28,600 rpm for 2 h at 4°C (Beckman Optima XE-90; SW32 Ti rotor). After centrifugation ...
-
bioRxiv - Immunology 2020Quote: ... Vesicles recovered by ultracentrifugation of filtered supernatant at 150,000 x g for 2 h at 4 °C using a Ti 45 rotor (Beckman Instruments, USA), were washed with phosphate-buffered saline (PBS ...
-
bioRxiv - Neuroscience 2022Quote: ... layers F1/2 were removed before transferring the combined F3/4 layer into a clean 25mL centrifuge tube (Beckman Coulter, #355618) and diluting in GM buffer (at least 1:4 ...
-
bioRxiv - Bioengineering 2023Quote: ... The gradient tubes were balanced and subjected to centrifugation at 135,000 × g for 2 h at 4 °C using a fixed-angle rotor (TLA-55, Beckman Coulter, USA). After DGUC ...
-
bioRxiv - Bioengineering 2023Quote: ... The gradient tubes were subjected to centrifugation at 135,000 × g for 2 h at 4 °C using a fixed-angle rotor (TLA-55, Beckman Coulter, USA). After DGUC ...
-
bioRxiv - Bioengineering 2023Quote: ... The gradient tube was balanced and subjected to ultracentrifugation at 150,000 × g for 2 h at 4 °C using a swinging-bucket rotor (SW 41 Ti Beckman Coulter, USA).
-
bioRxiv - Cell Biology 2023Quote: ... 5 mM Mg(OAc)2) and centrifuged for 20 min at 100,000 x g in a 70Ti rotor (Beckman Coulter). The resulting membrane pellet was resuspended in 1 ml rough microsome (RM ...
-
bioRxiv - Neuroscience 2019Quote: ... and 3% Percoll (1 ml each) in Polycarbonate centrifuge tubes (13 x 51 mm; Beckman Coulter). The gradients were then centrifuged for 15 min at 18,700 rcf ...
-
A laboratory framework for ongoing optimisation of amplification based genomic surveillance programsbioRxiv - Genomics 2023Quote: ... PCR amplicons for pools 1 and 2 were combined for each sample and purified with a 1:1 ratio of AMPureXP beads (Beckman Coulter) and eluted in 30μL of sterile water ...
-
bioRxiv - Genomics 2021Quote: ... The spores were washed twice with sterile ddH2O and pelleted at 3700g for 5 min at 4 °C in an Allegra X-12R centrifuge (Beckman, Brea, CA, USA). Spores were resuspended in sterile ddH2O and kept at 4°C until experiments.
-
bioRxiv - Microbiology 2022Quote: ... then clarified by centrifugation at 2000 rpm at 4°C for 5 min in a refrigerated tabletop centrifuge (Beckman Coulter, Indianapolis IN, USA) to remove large debris ...
-
bioRxiv - Microbiology 2023Quote: ... Extracellular vesicles were isolated by ultracentrifugation (one hour at 100,000xg, Beckman Coulter The Optima™ MAX-XP ...
-
bioRxiv - Immunology 2021Quote: ... The pelleted exosomes from above supernatants were further centrifuged at 100,000g (26,450rpm) for 2 h at 4 °C (Beckman Coulter, Optima XE-90) and resuspended in PBS ...
-
bioRxiv - Microbiology 2021Quote: ... Samples were centrifuged at 130,000 × g for 2 h at 4°C in a TLA100.3 rotor (Beckman Optima TLX table top centrifuge). Following centrifugation ...
-
bioRxiv - Neuroscience 2021Quote: ... The post nuclear supernatant was transferred to an ultracentrifuge tube and centrifuged for 2 h at 245,000 g at 4 °C in a Beckman L90 Ultracentrifuge (Beckman Coulter, Mississauga, Canada) to pellet remaining membrane.
-
bioRxiv - Immunology 2022Quote: ... Ultracentrifugation in a Beckman L7-65 ultracentrifuge at 25,000 rpm for 2 hours at 4°C using a Beckman SW28 rotor (Beckman Coulter, CA, USA) was performed to pellet the viruses through the sucrose cushion while soluble egg proteins were removed ...
-
bioRxiv - Microbiology 2019Quote: ... and viruses were pelleted via ultracentrifugation for 2 hours at 125,000 x g at 4°C using an SW55-Ti rotor (Beckman Coulter, Indianapolis, IN). Following centrifugation ...
-
bioRxiv - Cell Biology 2023Quote: ... cells were blocked in 2% human serum and PBS for 30 min at 4°C and stained with DC-SIGN (Beckman Coulter #A07407), CD80 (BioLegend #305214) ...
-
bioRxiv - Plant Biology 2023Quote: ... 700 μl of obtained extract was applied to a chilled sucrose density gradient and centrifuged at 4 °C for 2 hours 45 minutes at 151,000 ×g using the SW 41 Ti rotor (Beckman Culture Life Sciences). After centrifugation ...
-
bioRxiv - Molecular Biology 2023Quote: ... The lysates were loaded onto the sucrose gradients and centrifuged at 40’000 rpm for 2 h at 4°C using the SW 41 Ti rotor (Beckman Coulter, Cat# 331362). Subsequently ...
-
bioRxiv - Biochemistry 2023Quote: ... Samples were centrifuged at 100,000 × g for 2 hr at 4 °C (Type 50.2 Ti Fixed angle ultracentrifuge rotor, Beckman Coulter, Brea, CA, USA). The supernatants were aspirated ...
-
bioRxiv - Cell Biology 2024Quote: ... Samples were centrifuged at 60,000 rpm at 4°C for 2 h on an SW65 Ti ultracentrifuge rotor (Beckman Coulter, California, USA). The pellets were gently washed by dispensing and removing 500 µl of ice-cold RNase-free water ...
-
bioRxiv - Biophysics 2022Quote: SpeMreBs with a volume of 200 μL were polymerised for 1 to 6 h and centrifuged (100,000 rpm, 23°C, 120 min) in a TLA-100 rotor (Beckman Coulter). The pellet was resuspended in 200 μL of water ...
-
bioRxiv - Biochemistry 2022Quote: ... The lysed cells were centrifuged at 41399 g and 6 °C and for 1 hour (Beckman Avanti J-25 centrifuge) to obtain the cytoplasmic protein extract.
-
bioRxiv - Cell Biology 2022Quote: ... were mixed 1:1 with liposomes (6 mg/ml) and floated for 2h at 55 000 rpm in a TLS-55 rotor (Beckman) at 25°C through a sucrose gradient ...
-
bioRxiv - Biophysics 2023Quote: SpeMreBs in buffer S polymerized at room temperature with a volume of 200 μL were polymerized for 1–6 h and centrifuged (100,000 rpm at 23 °C for 120 min) in a TLA-100 rotor (Beckman Coulter) (2) ...
-
bioRxiv - Developmental Biology 2023Quote: ... and centrifuged at 40,000 rpm for 1 h at 4°C (Beckman SW-41Ti rotor). Supernatants were discarded ...
-
bioRxiv - Neuroscience 2022Quote: ... The samples were then spun at 31000 x g (18468 rpm) for 5 min at 4°C in a fixed-angle rotor (50.2 Ti rotor in Beckman Coulter Optima L-100 XP) with slow brake ...
-
bioRxiv - Cancer Biology 2022Quote: ... the genomic DNA was cleaned up with AMPure XP beads at 3:1 ratio (Beckman Coulter A63880) and eluted in the 10 mM Tris-HCl (pH 8.0) ...
-
bioRxiv - Microbiology 2021Quote: ... and extracellular vesicles including exosomes and virions were pelleted by ultracentrifugation at 141,000 g at 4 °C for 2 h in a swinging-bucket rotor (SW28; Beckman Coulter, Brea, CA, USA). The pellet was resuspended in filtered PBS and centrifuged at 18,300 g and 4°C for 10 min to remove insoluble aggregates ...
-
bioRxiv - Genomics 2020Quote: ... were layered onto a 1.8M sucrose cushion and ultra-centrifuged at 24,400 rpm at 4°C for 2 hours using a SW28 swinging bucket rotor (Beckman Coulter Optimal centrifuge #L90K). The nuclear pellet was re-suspended in 2% BSA in 1X PBS ...
-
bioRxiv - Microbiology 2020Quote: ... EMVs were obtained by ultracentrifugation from 4 mL of filtrate at 100,000 × g (average centrifugal force) and 4°C for 2 h with an OptimaX centrifuge (Beckman Coulter, Brea, CA, USA). The pellets were resuspended in 400 μL of Dulbecco’s phosphate-buffered saline (DPBS ...
-
bioRxiv - Neuroscience 2022Quote: ... The tubes were sealed and centrifuged at 50,000 rpm at 4°C for 2 h in an OptimaTM L-90K ultracentrifuge using the 70.1Ti rotor (Beckman Coulter, Brea, CA, USA). After the centrifugation ...
-
bioRxiv - Genomics 2019Quote: ... Libraries were purified one more time with SPRI Beads (Beckman Coulter, 1.5x). Libraries were quantified using a Qubit fluorometer (Life technologies ...
-
bioRxiv - Genomics 2021Quote: ... Libraries were purified one more time with SPRISelect reagent (Beckman Coulter, 1.5x). Libraries were quantified using a Qubit fluorimeter (Life technologies ...
-
bioRxiv - Cell Biology 2020Quote: ... and then the sample was centrifuged at 182,000g for 1 h at 4°C (Beckman SW40). LD fraction was carefully collected from the top band of the gradient and washed three times using 200 μL of buffer B ...
-
bioRxiv - Cell Biology 2022Quote: ... and incubated for 1 hr at +4°C before the flow cytometry analysis (Beckman Coulter CytoFlex) or sorting (SONY MA900) ...
-
bioRxiv - Biochemistry 2023Quote: ... The crude lysate was centrifuged for 1 hour at 20,000 rpm and 4 °C (Beckman Coulter). The supernatant was filtered using a 0.44 μm syringe filter (Sartorius ...
-
bioRxiv - Biophysics 2023Quote: ... The cell lysate was centrifuged at 4 °C at 35000 rpm for 1 hour by Beckman Optima™ L-80XP ultracentrifuge equipped with a Ti-45 rotor (Beckman ...
-
bioRxiv - Synthetic Biology 2022Quote: ... and 6 mL respectively in OptiSeal tubes (Beckman, 361625). The step gradients were spun in a Beckman Type 70ti rotor (Beckman ...
-
bioRxiv - Cell Biology 2020Quote: ... containing the phosphatases and proteases inhibitors and centrifuged at 100,000xg for 1 h through a 3 ml 1.4 M sucrose cushion using a TL100 centrifuge (Beckman). The crude heavy nuclear fraction and purified nuclei were resuspended in buffer A and extracted with 1% Triton X-100 for 5 min at 4°C (cNM ...
-
bioRxiv - Microbiology 2020Quote: ... and layered on top of a two-step sucrose gradient (20%/50% w/v in HNE) and centrifuged for 2 h at 154 000 x g at 4 °C in a SW41 rotor (Beckman Coulter, Woerden, the Netherlands) to clear from cell debris ...
-
bioRxiv - Molecular Biology 2022Quote: ... 4°C (Beckman Coulter). The pellet containing lentiviral particles was suspended in the residual medium ...
-
bioRxiv - Genomics 2020Quote: ... 4°C (Beckman Coulter). Supernatant was loaded onto 5 ml HisTrap FF columns (GE Healthcare ...
-
bioRxiv - Molecular Biology 2020Quote: ... 4°C (Beckman Coulter). Clarified lysates were poured several times over 0.5-1 ml Streptactin resin (IBA ...
-
bioRxiv - Cancer Biology 2023Quote: ... 4°C (Beckman Coulter). The pellet containing lentiviral particles was suspended in the residual medium ...
-
bioRxiv - Immunology 2021Quote: ... 39 mL of cGAMP-VLP-containing supernatant was gently overlaid on 6 mL of cold PBS containing 20% sterile filtered endotoxin free sucrose in 6 Ultra-Clear tubes (Beckman Coulter, ref 344058), and centrifuged for 1 hour and 30 minutes at 100,000 g 4°C ...