Labshake search
Citations for Beckman :
101 - 150 of 468 citations for Mouse Anti Human Papilloma virus type 18 718 238 since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Molecular Biology 2019Quote: ... Gradients were centrifuged 18-20h at 192,000g in a SW40 rotor (k-factor 144.5) (Beckman Coulter, Brea, CA). For RNA extraction and small RNA library preparation ...
-
bioRxiv - Microbiology 2022Quote: ... The sample-containing tube was spun at 31,000 RPM for 18 hours using SW 32.1 rotor (Beckman Coulter). 1-mL fractions were collected from the bottom of the tube ...
-
bioRxiv - Biochemistry 2023Quote: ... A discontinuous sucrose gradient was formed by overlaying with 6 ml of 35% sucrose and 3.5 ml of 5% sucrose in the same buffer containing 0.25 M Na2CO3 and centrifuged at 38,000 rpm for 18 h in an SW41 rotor (Beckman). Twelve fractions were collected from top to bottom ...
-
bioRxiv - Molecular Biology 2023Quote: ... 3 mM BME and centrifuged for 18 h at 30,000 rpm in a Ti 50.2 rotor (Beckman Coulter) at 4°C ...
-
bioRxiv - Immunology 2019Quote: The following antibodies were used: anti-p24-FITC (mouse monoclonal, Beckman and Coulter, #KC-57); anti-CD3-Pacific Blue (mouse monoclonal ...
-
bioRxiv - Microbiology 2024Quote: ... cells were stained with primary anti-HIV-Gag antibody (Beckman-Coulter; KC57-RD1, mouse derived), and with α-mouse Alexa Fluor555-conjugated secondary antibody (Invitrogen ...
-
bioRxiv - Microbiology 2024Quote: ... cells were stained with primary anti-HIV-Gag antibody (Beckman-Coulter; KC57-FITC, mouse derived), and cells were acquired using the MACs Quant Flow Cytometer (Milentyi ...
-
bioRxiv - Microbiology 2021Quote: ... the percentages of anti-human IgG postive cells in GFP positive cells were then analyzed using flow cytometer (Cytoflex S, Beckman). LIVE/DEAD fixable aqua (Thermo Fisher Scientific ...
-
bioRxiv - Microbiology 2020Quote: ... The virus was then purified over a 20% sucrose cushion by centrifugation at 35,000 rpm (Beckman Coulter SW41 rotor) for 3 h at 4°C ...
-
Human Sex Matters: Y-linked lysine demethylase 5D drives accelerated male osteogenic differentiationbioRxiv - Cell Biology 2021Quote: ... Virus was transferred into conical tubes and spin at 20000rpm for 2 hours at 4°C in (Beckman TST2838) swinging bucket rotor ...
-
bioRxiv - Molecular Biology 2020Quote: ... Virus particles in the supernatant were pelleted by ultracentrifugation at 45.000 rpm for 45 min (Beckman 70.1 Ti Rotor) over a pad of 15% sucrose in 10 mM Tris-HCl buffer (pH 7.4) ...
-
bioRxiv - Microbiology 2024Quote: ... Virus RNA was extracted with a magnetic bead-based RNA extraction kit (RNAdvance Viral Reagent kit, Beckman Coulter, C63510) on an epMotion® 5073t liquid handler (Eppendorf ...
-
bioRxiv - Immunology 2021Quote: ... Filtered supernatant was then centrifuged using fixed angle type 70.1Ti rotor (Beckman Coulter) in a Beckman L8-55M ultracentrifuge ...
-
bioRxiv - Bioengineering 2021Quote: ... and spun at 20,000xg for 45 min in a type 50.2Ti rotor (Beckman-Coulter Optima XE-90 ultracentrifuge ...
-
bioRxiv - Synthetic Biology 2022Quote: ... The step gradients were spun in a Beckman Type 70ti rotor (Beckman, 337922) in a Sorvall WX+ ultracentrifuge (Thermo Scientific ...
-
bioRxiv - Molecular Biology 2023Quote: ... The supernatant was further clarified in a Type 45 Ti rotor (Beckman Coulter) at 45,000 rpm for 50 min at 4°C ...
-
bioRxiv - Immunology 2023Quote: ... followed by centrifugation at 350,000g using a Type 70 Ti ultracentrifuge rotor (Beckman). Following centrifugation ...
-
bioRxiv - Biochemistry 2023Quote: ... The supernatant was collected and centrifuged in a Type 45 Ti rotor (Beckman) at 45,000 rpm for 50 min at 4 °C ...
-
bioRxiv - Biochemistry 2023Quote: ... Lysate was clarified at 35,000 rpm in a Type 45 Ti rotor (Beckman) for 45 min at 4°C and the supernatant was mixed with 3 mL Ni-NTA agarose (Qiagen ...
-
bioRxiv - Biophysics 2022Quote: ... The sample was loaded on top of the glycerol gradient and centrifuged at 4°C for 18 h at a speed of 35,000 rpm in SW-41Ti rotor (Beckman). Fractions of 500 μL were collected ...
-
bioRxiv - Microbiology 2021Quote: ... 200mM NaCl was used to top up the 13mL polyethylene tube and the solutions were spun at 27,000×g for 18 hours at 4°C using SW45 Ti rotor (Beckman). 1mL of top fraction ...
-
bioRxiv - Biophysics 2021Quote: ... sucrose density gradients and centrifuged at 24,000 × rpm (102,170 × g) for 18 h at 4°C (Sw40Ti rotor, Beckman Coulter). The fractions of the sucrose gradient were applied to SDS-PAGE ...
-
bioRxiv - Biophysics 2021Quote: ... The polymerized microtubules were centrifuged for 30 min at 18000 x g in a Microfuge 18 Centrifuge (Beckman Coulter). After centrifugation the pellet was resuspended in BRB80T.
-
bioRxiv - Biophysics 2021Quote: ... The polymerized microtubules were centrifuged for 30 min at 18000 x g in a Microfuge 18 Centrifuge (Beckman Coulter). After centrifugation ...
-
bioRxiv - Microbiology 2022Quote: ... and the mixture was centrifuged for 18 h at 36,000 rpm in an SW55 Ti rotor (Beckman, Fullerton, CA) at 4°C ...
-
bioRxiv - Neuroscience 2019Quote: ... Then the lysates were spin down at 67,000 rpm for 1 hour at 18 °C with the ultracentrifuge (Beckman). The AAV particles were collected by aspirating the interface between 40-60% iodixanol with a syringe ...
-
bioRxiv - Neuroscience 2022Quote: ... Then the lysates were spin down at 67,000 rpm for 1 hour at 18 °C with the ultracentrifuge (Beckman). The AAV particles were collected by collecting the interface between 40 and 60% iodixanol with a syringe ...
-
bioRxiv - Cancer Biology 2023Quote: ... The polymerized microtubules were centrifuged for 30 min at 18000 x g in a Microfuge 18 Centrifuge (Beckman Coulter). After centrifugation the pellet was resuspended in BRB80.
-
bioRxiv - Cell Biology 2024Quote: ... The polymerized microtubules were centrifuged for 30 min at 18000 x g in a Microfuge 18 Centrifuge (Beckman Coulter). After centrifugation the pellet was resuspended and kept in BRB80T at room temperature.
-
bioRxiv - Cancer Biology 2019Quote: Cells were stained for 30 min (minutes) with the anti-human monoclonal antibody CD11b-PE (IM2581U, Beckman Coulter, Brea, CA, USA), CD14-FITC (555397 ...
-
bioRxiv - Cell Biology 2022Quote: ... the virus-cell mixture was centrifuged at 1,000 rcf for 2 hours at 32°C (Beckman Coulter, Allegra X-30R). Infected cells were then cultured as described above and subsequently FACS-sorted for the establishment of clonal cell lines.
-
bioRxiv - Biophysics 2023Quote: ... Virus-containing supernatants were collected at 48 hours and 72 hours after transfection and concentrated using ultracentrifugation (Ultraclear, Beckman 344058). The transduction capacity of the viral vector product was confirmed by culturing non-transfected HEK293T cells with the virus after 24 hours and assessing via fluorescent imaging.
-
bioRxiv - Biochemistry 2020Quote: ... Protein expression was continued for 18 h before harvesting cells by centrifugation (4°C, 8000 rpm, 10 min in Beckman Coulter Avanti JXN-26 centrifuge ...
-
bioRxiv - Biophysics 2021Quote: ... The polymerized microtubules were diluted in BRB80T (BRB80 supplemented with 10μM taxol (paclitaxel)) and centrifuged for 30 min at 18000 x g in a Microfuge 18 Centrifuge (Beckman Coulter). After centrifugation the pellet was resuspended in BRB80T.
-
bioRxiv - Pharmacology and Toxicology 2020Quote: Samples were centrifuged at 13,000 rpm (14,300 rcf) for 10 min using a Microfuge®18 Centrifuge (Beckman Coulter, USA). The supernatant was measured using a Zetasizer Nano ZS (Malvern Instruments Ltd. ...
-
bioRxiv - Microbiology 2021Quote: ... culture samples were diluted (1:100 or 1:1000) with 0.2-µm-filtered 18% BSW and were analysed with a Multisizer M4 Coulter cytometer (Beckman-Coulter) equipped with a 20 or 30 µm aperture tube ...
-
bioRxiv - Molecular Biology 2019Quote: ... Supernatants were then loaded on 150% (w/v) cesium chloride for ultracentrifugation for 18 hr at 42000 rpm in a NVT 65.2 rotor (Beckman coulter) at 25°C ...
-
bioRxiv - Developmental Biology 2022Quote: ... the whole embryos were individually mounted on glass slides with spacers of approximately 100–500 µm, which were adjusted depending on the sample using sticky tape (CT-18S, Nichiban) and silicone vacuum grease (335148, Beckman). To view different sides of a single embryo ...
-
bioRxiv - Cell Biology 2023Quote: ... The iodixanol density gradients were centrifuged at 100,000 x g at 4◦C for 18 hours in SW41Ti rotor (Beckman Coulter). Ten fractions (F1 ...
-
bioRxiv - Neuroscience 2023Quote: ... The gradients were centrifuged for 18 h at 100,000 xg at 4 °C in a SW 40 rotor (Beckman Coulter). 500 µl fractions were collected from the top of the ultracentrifuge tubes and analyzed by WB analysis.
-
bioRxiv - Cell Biology 2023Quote: ... The gradient was centrifuged at 4 °C and 100,000 ˗ g for 18 h (Optima L-80 XP Ultracentrifuge with Swing Rotor (Beckman Coulter)) ...
-
bioRxiv - Microbiology 2023Quote: ... Medium was cleared from EVs by ultracentrifugation at 100,000 ×g for 18 h at 4°C in a LE-80 ultracentrifuge (Beckman Coulter) with a 60Ti rotor [13] ...
-
bioRxiv - Microbiology 2023Quote: ... Media was cleared from EVs by ultracentrifugation at 100,000×g for 18 h at 4 °C in a LE-80 ultracentrifuge (Beckman Coulter) with a 60Ti rotor ...
-
bioRxiv - Neuroscience 2024Quote: ... for 30 minutes at 37 °C prior to centrifugation at 18.000 x g for 30 min in a Microfuge 18 Centrifuge (Beckman Coulter) and resuspension of the microtubule pellet in BRB80 supplemented with 10 µM Taxol (Sigma Aldrich ...
-
bioRxiv - Cell Biology 2022Quote: ... labeled filamentous actin was centrifuged at 167,000 x g (Type 50.2 rotor, Beckman Coulter) for 3 hours at 4°C ...
-
bioRxiv - Biochemistry 2022Quote: ... The lysate was clarified by centrifugation in a Type 45 Ti rotor (Beckman Coulter) at 35,000 RPM for 35 min at 4 °C ...
-
bioRxiv - Neuroscience 2022Quote: ... followed by centrifugation at 350,000 xg using a Type 70 Ti ultracentrifuge rotor (Beckman). Following centrifugation ...
-
bioRxiv - Cell Biology 2019Quote: ... Lysates were cleared by centrifugation at 35000 rpm (Beckman Instruments type 45 Ti rotor) for 1.5 h at 4°C ...
-
bioRxiv - Cell Biology 2019Quote: ... Lysates were cleared by centrifugation at 35000 rpm (Beckman Instruments type 45 Ti rotor) for 1.5h at 4°C ...
-
bioRxiv - Pharmacology and Toxicology 2021Quote: ... fixed angle Type 45 Ti rotor (k factor = 133; Beckman Coulter, Miami, FL, USA), at 4°C ...