Labshake search
Citations for Beckman :
101 - 150 of 325 citations for 7 7 dimethylbicyclo 3.1.1 heptan 2 ol since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Immunology 2023Quote: Cells were washed with 2% FACs and data was acquired using CytoFLEX S (Beckman Coulter, USA) and analyzed via FlowJo v10 software (Oregon ...
-
bioRxiv - Biochemistry 2020Quote: ... One was through twice daily measurement of 2 or 3 levels of QC specimens obtained from Beckman Coulter Inc ...
-
bioRxiv - Neuroscience 2020Quote: ... and were centrifuged at 82,500 x g for 2 h at 4 °C (Beckman SW28 swing rotor). The band between 1.0 and 1.2 M sucrose was collected as the synaptosome fraction and diluted with 80 mM Tris-HCl (pH 8.0) ...
-
bioRxiv - Microbiology 2019Quote: ... Gradients were then spun at 38,000 RPM for 2 h in a SW41Ti rotor (Beckman Coulter; 331362) at 4°C ...
-
bioRxiv - Pathology 2021Quote: ... BALF (10 μl) was applied to glass microscopy slides using a cytocentrifuge (StatSpin CytoFuge 2, Beckman Coulter). Slides were fixed with 10% neutral buffered formalin ...
-
bioRxiv - Evolutionary Biology 2020Quote: ... in 67 mM HEPES-KOH pH 7.2) after 2 h of ultracentrifugation (4 °C, 5000 RPM, Beckman SW41 ...
-
bioRxiv - Developmental Biology 2021Quote: ... inhibin B and AMH/MIS by 2-site ELISA (Beckman Coulter and Beckman Coulter Gen II, respectively); and βHCG and AFP CMIA-ARCHTECT I 4000.The assays were performed as recommended by the manufacturers ...
-
bioRxiv - Microbiology 2022Quote: ... 2 ng of each product were pooled for subsequent cleanup using the AmpureXP PCR cleanup protocol (Beckman). The pooled library was quantified by a picogreen assay and loaded onto an Illumina MiSeq Reagent Kit v3 (600-cycle ...
-
bioRxiv - Cell Biology 2022Quote: ... The supernatant was ultracentrifuged for 2 h at 150,000 x g in an Optima XP centrifuge (Beckman) with a MLA-50 rotor ...
-
bioRxiv - Microbiology 2022Quote: ... cells were resuspended in 2% FBS-PBS and analyzed by a CytoFLEX flow cytometer (Beckman Coulter, USA). The final results from three independent experiments were averaged and shown in the histogram.
-
bioRxiv - Biochemistry 2023Quote: ... The cell culture microplate was centrifuged at 300g for 2 min (Beckman Coulter Allegra X-22R Centrifuge) to bring the cells to the well bottom ...
-
bioRxiv - Molecular Biology 2023Quote: ... Reactions were incubated for 2 hr at 60°C and purified by Ampure XP beads (Beckman #A63881). Libraries were PCR amplified in a 30 µL reaction containing 14 µL circularized library ...
-
bioRxiv - Molecular Biology 2023Quote: ... Reactions were incubated for 2 hr at 60°C and purified by Ampure XP beads (Beckman #A63881). Libraries were PCR amplified in a 30 µL reaction containing 14 µL circularized library ...
-
bioRxiv - Molecular Biology 2023Quote: ... followed by ultracentrifugation at 70k RPM at 4⁰C for 2 h (Optima TLX ultracentrifuge, Beckman Coulter). Ribosome pellets were then resuspended in Trizol and extracted for RNA according to manufacturer’s instructions ...
-
bioRxiv - Cancer Biology 2024Quote: ... Cells were then resuspended in PBS + 2% FBS and acquired on a Gallios flow cytometer (Beckman Coulter).
-
bioRxiv - Cancer Biology 2024Quote: ... centrifuged twice at 100,000 × g for 2 h at 4°C (Beckman Coulter Optima XE-90 Ultracentrifuge). The supernatant was replaced with DPBS between ultracentrifugation spins ...
-
bioRxiv - Genetics 2021Quote: ... and samples were evaluated 2 minutes later with a Cytomics FC500 flow cytometer (Beckman Coulter, Brea, CA, USA) AO was excited with a 488 nm argon laser ...
-
bioRxiv - Molecular Biology 2021Quote: ... Gradients were centrifuged at 36000 RPM for 2 hours at 4°C in a SW41 rotor (Beckman Coulter) and then fractions were collected using a gradient collector (Teledyne ISCO gradient station ...
-
bioRxiv - Genomics 2020Quote: ... The PCR products were purified by using 1.3X Agencourt AMPure XP beads (2 or 3 cycles; Beckman Coulter) and evaluated by using an Agilent High Sensitivity DNA Kit on an Agilent 2100 Bioanalyzer (Agilent) ...
-
bioRxiv - Cancer Biology 2020Quote: ... concentrated for 2 h by ultracentrifugation in a swing-out rotor SW-32Ti (Beckman Coulter, Brea, US-CA) at 26000 g ...
-
bioRxiv - Microbiology 2020Quote: ... Purification was done by ultracentrifugation for 2 h at 154,000xg at 4°C in a SW41 rotor (Beckman) using a two-step sucrose gradient (20%/50% w/v in HNE) ...
-
bioRxiv - Physiology 2019Quote: ... plasma samples were deproteinized with ZnSO4 and Ba(OH)2 and counted using a Liquid Scintillation Counter (Beckman Coulter LS6500 Multi-purpose Scintillation Counter) ...
-
bioRxiv - Cell Biology 2020Quote: ... the cleared supernatant was ultracentrifuged at 47,000 g for 2 hours at 4 °C using the JA25.50 rotor (Beckman). The virus was resuspended overnight in 180 μL D10 medium at 4 °C ...
-
bioRxiv - Microbiology 2019Quote: ... and adding this to 3 ml sterile inoculum water (Beckman Coulter, Inc. Brea, CA, cat no B1015-2) and 840 μl phenol red solution ...
-
bioRxiv - Cell Biology 2021Quote: ... 4 °C for 2 h in an Optima L-100XP ultracentrifuge (with SW 55 Ti rotor, Beckman Coulter). Fractionation was done manually by collecting every 200 μl volume from the top till the bottom of each centrifuge tube ...
-
bioRxiv - Cell Biology 2022Quote: ... Lentiviral particles were then concentrated by centrifugation for 2 hours at 20,000 rcf (Beckman Coulter, Optima L-100K) in round bottom polypropylene tubes (Beckman Coulter ...
-
bioRxiv - Cell Biology 2022Quote: Total RNA of Caco-2 cells and human ileum organoids was extracted using RNAdvance Tissue kit (Beckman Coulter) and total RNA of mouse organoids was isolated using Quick-RNA Miniprep Plus Kit (Zymo Research) ...
-
bioRxiv - Molecular Biology 2023Quote: ... Digested extracts were then loaded on 1 M sucrose cushions 116 and centrifuged at 70,000 rpm for 2 hours at 4°C in a TLA100.4 rotor (Beckman). Ribosome pellets were resuspended in 300 µl of TRIzol reagent (Invitrogen) ...
-
bioRxiv - Microbiology 2023Quote: ... The filtrate was subjected to ultracentrifugation at 200,000xg for 2 h (Optima L-100 XP ultracentrifuge; Beckman Coulter). Supernatants were discarded ...
-
bioRxiv - Immunology 2023Quote: ... CD27 and BA.1 or BA.2 were sorted using a MoFlo Astrios EQ Cell Sorter (Beckman Coulter). FACS data were collected by Summit 6.0 (Beckman Coulter ...
-
bioRxiv - Microbiology 2024Quote: ... (The filtrate was subjected to ultracentrifugation at 100,000g for 2 h (Optima L-90 K ultracentrifuge; Beckman Coulter). The supernatant was discarded and the pellet was washed with sterile PBS and filtered through a sterile 0.2 μm-pore polyvinylidene difluoride (PVDF ...
-
bioRxiv - Neuroscience 2021Quote: ... 2 mL of 20% (w/v) sucrose in DPBS (-Ca, -Mg) is prepared in ultracentrifuge tubes (Beckman Coulter, 344058) to which the divided EnvA- pseudotyped viral media is added before pelleting (20,000 RPM for 2 hours at 4°C) ...
-
bioRxiv - Cell Biology 2019Quote: ... Sucrose gradients were subjected to ultracentrifugation (SW41 Ti 11E1698 rotor; Beckman at 260,000xg for 2 h at 4□°C) and fractionated by displacement using 60% sucrose/0.01% bromophenol blue on an ISCO Foxy fraction collector (35 s for each fraction ...
-
bioRxiv - Cell Biology 2020Quote: ... Lysates were loaded on the top of the gradient and centrifuged at 260,000 × g and 4 °C for 2 h using SW 41 rotor (Beckman). Collection of polysomal fractions were done using Piston Gradient Fractionator (BioComp) ...
-
Human Sex Matters: Y-linked lysine demethylase 5D drives accelerated male osteogenic differentiationbioRxiv - Cell Biology 2021Quote: ... Virus was transferred into conical tubes and spin at 20000rpm for 2 hours at 4°C in (Beckman TST2838) swinging bucket rotor ...
-
bioRxiv - Biochemistry 2021Quote: ... 2 mM DTT) by being centrifuged at 73000 rpm for 45 minutes at 4°C (Beckman Coulter TL120.2 rotor). The mitoribosomal pellet was subsequently resuspended in ribosome resuspension buffer (25 mM HEPES-KOH pH = 7.5 ...
-
bioRxiv - Biochemistry 2020Quote: ... The functional complex was recovered as a jelly-like pellet by centrifugation at 60,000 rpm at 25°C for 2 h in an ultracentrifuge (128,000 g in a TLA 120.2 Beckman rotor) and packed into a 1.9 mm rotor ...
-
bioRxiv - Microbiology 2020Quote: ... and separated in potassium tartrate-glycerol gradient 10–35% for 2 hrs at 175,000 ×g (Beckman SW41 Ti rotor). Purified viral particles were suspended in 10 µg/ml BSA solution or 10 µg/ml CbAE-1 solution and incubated for 1 hr at room temperature ...
-
bioRxiv - Neuroscience 2022Quote: ... and centrifuged at 24,000 rpm for 2 h at 4°C using a SW-Ti32 swinging bucket (Beckman Coulter). The upper layer was discarded ...
-
bioRxiv - Cell Biology 2019Quote: ... MT seeds were diluted in BRB80 containing 2 μM taxol and centrifuged at 100,000 g (Optima TL100; Beckman Coulter) for 15 min ...
-
bioRxiv - Cell Biology 2021Quote: ... The supernatant was cleared again by 2 rounds of ultracentrifugation at 100,000 rpm (358,400 x g; Beckman TLA-120.2) for 10 minutes at 0°C ...
-
bioRxiv - Cell Biology 2021Quote: ... Pellets were resuspended in 0.9% NaCl and spun at 110,000 × g for 2 hours at 4°C in an XPN-80 ultracentrifuge equipped with a Type 50.4 Ti rotor (Beckman Coulter ...
-
bioRxiv - Microbiology 2021Quote: ... The VLPs were concentrated by ultracentrifugation for 2 h at 31,000 rpm at 4 °C (Beckman SW-31Ti rotor), and then resuspended in 500 μL of Ex-Cell 405 medium ...
-
bioRxiv - Molecular Biology 2021Quote: ... and the tube was centrifuged for 2 hours at 190,000 x g in a swing-out rotor (SW40 Ti; Beckman Coulter ...
-
bioRxiv - Microbiology 2021Quote: ... and either aliquoted or concentrated by ultracentrifugation using 20% (w/v) sucrose cushions for 2 hours at 25,000 rpm in an SW41 rotor (Beckman).
-
bioRxiv - Cell Biology 2022Quote: ... milk was prevented from cooling down and was processed within 20 minutes after collection by 2 rounds of centrifugation at 3,000xg for 10 minutes at 23°C (Beckman Coulter Allegra X-12R ...
-
bioRxiv - Microbiology 2022Quote: ... The pellet was resuspended in 2 ml (per fraction) of the supernatant and ultracentrifuged (Optima MAX-TL, Beckman Coulter) at 12,000 rpm (TLA55 rotor ...
-
bioRxiv - Molecular Biology 2023Quote: ... The gradients were centrifuged at 38,300 rpm for 2 hours and 45 min at 4 °C in a SW-40Ti (Beckman) rotor using an Optima XE-100 Ultracentrifuge (Beckman) ...
-
bioRxiv - Molecular Biology 2023Quote: ... The gradients were centrifuged at 38,300 rpm for 2 hours and 45 min at 4 °C in a SW-40Ti (Beckman) rotor using an Optima XE-100 Ultracentrifuge (Beckman) ...
-
bioRxiv - Plant Biology 2023Quote: ... Extract was then centrifuged at 40 000 rpm for 2 hours at 4°C using the 50Ti rotor (Beckman). A protocole previsouly used in the laboratory and described in Maclot et al ...