Labshake search
Citations for Beckman :
1151 - 1200 of 1386 citations for 6 chloro 4 methylquinolin 2 ol since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Molecular Biology 2019Quote: ... The supernatant was transferred to a new tube and spun at 100,000 × g for 60 min at 4°C in a SW50.1 swinging bucket rotor (Beckman CoulterTM, Palo Alto, CA) to pellet the membrane fraction ...
-
bioRxiv - Cell Biology 2021Quote: ... and centrifuged at 100 000 × g for 60 min at 4°C using rotor Ti-70 in an Optima LE-80K Ultra Centrifuge (Beckman Coulter, Australia). The harvested EV pellet was resuspended in 1 mL RNase-free Phosphate buffered saline (RNase-free PBS ...
-
bioRxiv - Neuroscience 2021Quote: ... Lentiviruses were purified by overlaying the virus containing media over a 20% sucrose solution before ultracentrifugation at 26,000 rpm for 90 minutes at 4 °C in a SW28Ti swinging-bucket ultracentrifuge rotor assembly in an Optima XPN-80 Ultracentrifuge (Beckman Optima Ultracentrifuge) and the viral pellet was resuspended in AimV™ media.
-
bioRxiv - Cell Biology 2020Quote: ... supernatants were centrifuged at 10,000 x g for 30 min at 4°C and the supernatants were transferred to ultracentrifuge tubes (Beckman Coulter, Brea, CA) and diluted with phosphate-buffered saline (PBS) ...
-
bioRxiv - Microbiology 2020Quote: ... All bacteria were harvested by centrifugation at 4000 rpm and 4°C in a JS 4.0 swinging bucket rotor (Beckman Coulter, Brea California) and immediately processed as described below.
-
bioRxiv - Microbiology 2021Quote: ... density gradient (35 to 0% in PBS) and ultracentrifuged at 200,000 × g for at least 12 hours at 4 °C (Beckman Optima XL-100K). The corresponding clear yellow band was collected ...
-
bioRxiv - Cell Biology 2022Quote: ... The resulting supernatant was centrifuged at 10,000 x g for 30 minutes to remove any remaining debris and then ultra-centrifuged at 118,000 x g for 70 minutes at 4°C with a fixed-angle rotor (Ti-70, Beckman Coulter, Brea, CA). The pellet was washed with sterile 1X PBS and subjected to another cycle of ultracentrifugation at 118,000 x g for 70 minutes at 4°C ...
-
bioRxiv - Cancer Biology 2022Quote: ... The supernatants were further centrifuged at 10,000 × g for 30 min at 4°C to remove remaining cell debris and at 100,000 × g (Type 90 Ti Rotor, Beckman, Brea, CA, USA) overnight at 4°C to remove exosomes ...
-
bioRxiv - Biochemistry 2022Quote: ... Triton-X was added to the lysate to a final concentration of 0.1% and clarified by spinning at 15,000 RCF at 4°C for 45 minutes (Beckman Coulter JA-20 rotor). The supernatant was loaded onto a 5 mL HisTrap™ FF crude column (GE Healthcare ...
-
bioRxiv - Molecular Biology 2023Quote: ... The cell lysate was centrifuged at 4 °C at 35000 rpm for 1 hour with Beckman Optima™ L-80XP Ultracentrifuge equipped with Ti45 rotor (Beckman, USA). The pellet containing membranes and cell debris was discarded ...
-
Isolation and characterization of a novel phage of Vibrio parahaemolyticus with biocontrol potentialbioRxiv - Microbiology 2022Quote: ... for purification and centrifuged at 200,000 × g at 4°C for 24 h using an Optima L-100 XP ultracentrifuge (Beckman Coulter, CA, USA). The purified phage particles were dialyzed through 30-kDa superfilters (Millipore ...
-
bioRxiv - Neuroscience 2023Quote: ... re-suspend in the homogenization buffer and centrifuged at 100,000 x g for 40 min at 4°C (Beckman SWTi41 swing rotor). The pellet containing the growth cone were re-suspended in 50 μl of the homogenization buffer ...
-
bioRxiv - Neuroscience 2022Quote: ... The loaded gradient was ultracentrifuged at 69,150 x g for 1 h at 4 °C (SW 41 Ti Swinging-Bucket Rotor, Beckman Coulter, Cat. #331362) and the synaptosome fraction was harvested from the interface between the two sucrose layers ...
-
bioRxiv - Biochemistry 2022Quote: ... The supernatant was again centrifuged at 100000 g for 45 min at 4°C (Beckman Optima™ MAX-XP Rotor MLS-50). After filtering the supernatant through a 0.22 μm syringe filter ...
-
bioRxiv - Cell Biology 2022Quote: ... One milliliter of concentrated conditioned medium was pipetted on top of the gradient and samples were centrifuged for 18 h at 100,000 ×g and 4 °C using a SW 32.1 Ti rotor (Beckman Coulter, Fullerton, California, USA). Fractions of 1 mL were collected from the top and EV-rich fractions 9 and 10 (corresponding to a density of 1.10-1.12 g/mL ...
-
bioRxiv - Microbiology 2024Quote: ... Saliva was collected by expectoration into tubes on ice followed by centrifugation for 10 minutes at 4°C at 4000 x g (Beckman SX4750 rotor) to remove large debris and bacterial aggregates ...
-
bioRxiv - Cell Biology 2024Quote: ... The collected monosomes were then 1:1 diluted with PEB and centrifuged at 60,000 rpm at 4°C overnight on an SW65 Ti ultracentrifuge rotor (Beckman Coulter, California, USA). The pellets were resuspended in 250µl PEB with 50 mM NH4Cl ...
-
bioRxiv - Biochemistry 2023Quote: ... Cultures were then recovered by centrifugation (4,000 x g, 4 °C, 40 min in a Beckman Avanti JXN-26 (rotor: JLA 8.1)) and pellets resuspended in approximatively 30 mL of lysis buffer (20 mM HEPES ...
-
bioRxiv - Molecular Biology 2024Quote: ... ADEV isolation was performed by ultracentrifugation at 100,000 × g for 14 h at 4 °C (swing bucket rotor on minimum acceleration/break setting, SW 32Ti Beckman Coulter, Brea, CA), and ADEVs were resuspended in 200μL PBS and stored at −20°C until used16,41 ...
-
bioRxiv - Cell Biology 2023Quote: ... Following centrifugation at 131,300 × g for 24 hr at 4 °C using a MLS-50 Swinging-Bucket rotor (Beckman Coulter, Brea, CA) to sediment protein complexes ...
-
bioRxiv - Cell Biology 2024Quote: ... All centrifugation steps were done at 4°C and the last two steps were performed using Optima XE-90 ultracentrifuge (Beckman Coulter, A94471) with rotor SW32Ti (Beckman Coulter ...
-
bioRxiv - Cell Biology 2024Quote: ... and cells were isolated by centrifugation at 500 g for 5 min at 4°C followed by being treated with a red blood lysis buffer (Beckman Coulter, USA). After washing with PBS ...
-
bioRxiv - Microbiology 2023Quote: ... The lysate was clarified by centrifugation at 5500 rpm for 20 min at 4°C (AllegraTM 21R Centrifuge, Beckman Coulter, CA, USA). The sample was then loaded into a HisTrap HP 5 mL column (Cytiva ...
-
bioRxiv - Neuroscience 2023Quote: ... then spun at 100,000 x g for 30 min at 4°C in an ultracentrifuge (Beckman OPTIMA TLX with TLA-100.3 rotor). The supernatant was saved and the pellet went through a series of similar extractions using High-Salt Triton Buffer (High-Salt Buffer ...
-
bioRxiv - Neuroscience 2023Quote: ... The supernatants were then combined and centrifuged at 17,000g for 10min at 4°C in a Beckman SW41-Ti rotor (Beckman Coulter, Brea, CA). The supernatant was saved as the cytosolic (CYT ...
-
bioRxiv - Cell Biology 2023Quote: Myf5High and Myf5Low MuSCs were isolated from a pool of 4 male and 4 female mice and repeated in two independent experiments and total RNA was extracted using Agencourt RNAdvance tissue Kit (Beckman Coulter, #A32646) with a quality score of RQN 9.3 to 10 ...
-
bioRxiv - Cell Biology 2023Quote: ... was next subjected to ultracentrifugation at 120,000 × g for 4 h in a SW 28 Ti Swinging-Bucket Rotor (Beckman Coulter, Fullerton, CA) to sediment small EVs ...
-
bioRxiv - Biochemistry 2023Quote: ... Triton-X was added to the lysate to a final concentration of 0.1% and clarified by spinning at 15,000 RCF at 4°C for 45 minutes (Beckman Coulter JA-20 rotor). The supernatant was loaded onto a 5 mL HisTrap™ FF crude column (GE Healthcare ...
-
bioRxiv - Cell Biology 2023Quote: ... the supernatants were transferred into SW60 tubes (in vivo studies 1–4) or SW40 tubes (donated patients) (Beckman Coulter Inc., Brea, USA) and centrifuged at 10,000xg for 35 minutes ...
-
bioRxiv - Microbiology 2023Quote: ... Cells were incubated further overnight at 20°C and subsequently harvested by centrifugation (Beckman rotor 8.1000, 5000 rpm, 15 min, 4°C). The pellet was resuspended in PBS ...
-
bioRxiv - Biochemistry 2023Quote: ... by centrifugation at 80,000 × g for 30 min at 4°C using a TLS-55 rotor (Beckman Coulter Inc., Miami, FL, USA). Crista membranes were identified and removed based on fluorescence under a UV lamp ...
-
bioRxiv - Developmental Biology 2024Quote: ... for 30 min at 4°C in the dark followed by flow cytometry analysis on a CytoFlex 26 (Beckman Coulter, Indianapolis, IN) in PE-A and PerCP-A channels ...
-
bioRxiv - Neuroscience 2024Quote: ... The supernatant was segregated subsequent to centrifuging the brain tissue homogenate for 1 h at 100,000g and 4°C utilising an ultra-high-speed centrifuge (Beckman, Optima MAX-XP). The tissue residue was then reprocessed ...
-
bioRxiv - Biophysics 2024Quote: ... Samples were centrifuged at 24,000 rotations per minute using an S-28 rotor at 4◦C in an Optima XL-100K Ultracentrifuge (Beckman Coulter, Brea, CA). The supernatant was decanted ...
-
bioRxiv - Molecular Biology 2024Quote: ... was loaded on top of the gradient and spun at 4°C for 18 hr at 30,000 rpm (Beckman, Rotor SW-41Ti). Samples were fractionated with absorbance optics (λ = 260 nm ...
-
bioRxiv - Genetics 2021Quote: ... and samples were evaluated 2 minutes later with a Cytomics FC500 flow cytometer (Beckman Coulter, Brea, CA, USA) AO was excited with a 488 nm argon laser ...
-
bioRxiv - Genomics 2020Quote: ... The PCR products were purified by using 1.3X Agencourt AMPure XP beads (2 or 3 cycles; Beckman Coulter) and evaluated by using an Agilent High Sensitivity DNA Kit on an Agilent 2100 Bioanalyzer (Agilent) ...
-
bioRxiv - Cancer Biology 2020Quote: ... concentrated for 2 h by ultracentrifugation in a swing-out rotor SW-32Ti (Beckman Coulter, Brea, US-CA) at 26000 g ...
-
bioRxiv - Physiology 2019Quote: ... plasma samples were deproteinized with ZnSO4 and Ba(OH)2 and counted using a Liquid Scintillation Counter (Beckman Coulter LS6500 Multi-purpose Scintillation Counter) ...
-
bioRxiv - Microbiology 2019Quote: ... and adding this to 3 ml sterile inoculum water (Beckman Coulter, Inc. Brea, CA, cat no B1015-2) and 840 μl phenol red solution ...
-
bioRxiv - Cell Biology 2022Quote: ... Lentiviral particles were then concentrated by centrifugation for 2 hours at 20,000 rcf (Beckman Coulter, Optima L-100K) in round bottom polypropylene tubes (Beckman Coulter ...
-
bioRxiv - Cell Biology 2022Quote: Total RNA of Caco-2 cells and human ileum organoids was extracted using RNAdvance Tissue kit (Beckman Coulter) and total RNA of mouse organoids was isolated using Quick-RNA Miniprep Plus Kit (Zymo Research) ...
-
bioRxiv - Microbiology 2024Quote: ... (The filtrate was subjected to ultracentrifugation at 100,000g for 2 h (Optima L-90 K ultracentrifuge; Beckman Coulter). The supernatant was discarded and the pellet was washed with sterile PBS and filtered through a sterile 0.2 μm-pore polyvinylidene difluoride (PVDF ...
-
bioRxiv - Immunology 2023Quote: ... CD27 and BA.1 or BA.2 were sorted using a MoFlo Astrios EQ Cell Sorter (Beckman Coulter). FACS data were collected by Summit 6.0 (Beckman Coulter ...
-
bioRxiv - Microbiology 2023Quote: ... The filtrate was subjected to ultracentrifugation at 200,000xg for 2 h (Optima L-100 XP ultracentrifuge; Beckman Coulter). Supernatants were discarded ...
-
bioRxiv - Physiology 2024Quote: ... was analysed via a sequential 2-step immune-enzymatic assay (inter-assay CV 5.2-7.8%) according to manufacturer’s instructions (Beckman Coulter) and follicle stimulating hormone (FSH ...
-
bioRxiv - Microbiology 2020Quote: ... by ultra-centrifugation in a Beckman L7-65 ultracentrifuge at 25,000 rpm for two hours at 4°C using a Beckman SW28 rotor (Beckman Coulter, Brea, CA, USA). Supernatants were aspirated off and the pellets were re-suspended in PBS (pH 7.4) ...
-
bioRxiv - Microbiology 2020Quote: ... by centrifugation in a Beckman L7-65 ultracentrifuge at 25,000 rpm for 2h at 4°C using a Beckman SW28 rotor (Beckman Coulter, Brea, CA, USA). Supernatants were aspirated and the pellets were re-suspended in PBS (pH 7.4) ...
-
bioRxiv - Molecular Biology 2021Quote: ... The centrifugation is performed on a SW60Ti rotor at 40 000 g for 22 minutes at 4°C (Beckman Optima L-90K Ultracentrifuge). The mitochondrial fraction (400µL ...
-
bioRxiv - Molecular Biology 2020Quote: ... and plasma was separated by centrifugation (2,000 × g, 20 min, 4 °C) in a Microfuge 20R (cat. no. B30149, Beckman Coulter, Brea, CA, USA). Plasma was transferred to new 1.5 mL microcentrifuge tubes and further clarified by centrifugation (10,000 × g ...