Labshake search
Citations for Beckman :
1051 - 1100 of 1535 citations for 6 Ethyl 1H indole 2 3 dione 3 O 4 4 4 trifluoro butyl oxime since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2023Quote: ... The supernatants were then combined and centrifuged at 17,000g for 10min at 4°C in a Beckman SW41-Ti rotor (Beckman Coulter, Brea, CA). The supernatant was saved as the cytosolic (CYT ...
-
bioRxiv - Cell Biology 2023Quote: Myf5High and Myf5Low MuSCs were isolated from a pool of 4 male and 4 female mice and repeated in two independent experiments and total RNA was extracted using Agencourt RNAdvance tissue Kit (Beckman Coulter, #A32646) with a quality score of RQN 9.3 to 10 ...
-
bioRxiv - Cell Biology 2023Quote: ... was next subjected to ultracentrifugation at 120,000 × g for 4 h in a SW 28 Ti Swinging-Bucket Rotor (Beckman Coulter, Fullerton, CA) to sediment small EVs ...
-
bioRxiv - Biochemistry 2023Quote: ... Triton-X was added to the lysate to a final concentration of 0.1% and clarified by spinning at 15,000 RCF at 4°C for 45 minutes (Beckman Coulter JA-20 rotor). The supernatant was loaded onto a 5 mL HisTrap™ FF crude column (GE Healthcare ...
-
bioRxiv - Cell Biology 2023Quote: ... the supernatants were transferred into SW60 tubes (in vivo studies 1–4) or SW40 tubes (donated patients) (Beckman Coulter Inc., Brea, USA) and centrifuged at 10,000xg for 35 minutes ...
-
bioRxiv - Microbiology 2023Quote: ... Cells were incubated further overnight at 20°C and subsequently harvested by centrifugation (Beckman rotor 8.1000, 5000 rpm, 15 min, 4°C). The pellet was resuspended in PBS ...
-
bioRxiv - Biochemistry 2023Quote: ... by centrifugation at 80,000 × g for 30 min at 4°C using a TLS-55 rotor (Beckman Coulter Inc., Miami, FL, USA). Crista membranes were identified and removed based on fluorescence under a UV lamp ...
-
bioRxiv - Developmental Biology 2024Quote: ... for 30 min at 4°C in the dark followed by flow cytometry analysis on a CytoFlex 26 (Beckman Coulter, Indianapolis, IN) in PE-A and PerCP-A channels ...
-
bioRxiv - Neuroscience 2024Quote: ... The supernatant was segregated subsequent to centrifuging the brain tissue homogenate for 1 h at 100,000g and 4°C utilising an ultra-high-speed centrifuge (Beckman, Optima MAX-XP). The tissue residue was then reprocessed ...
-
bioRxiv - Biophysics 2024Quote: ... Samples were centrifuged at 24,000 rotations per minute using an S-28 rotor at 4◦C in an Optima XL-100K Ultracentrifuge (Beckman Coulter, Brea, CA). The supernatant was decanted ...
-
bioRxiv - Molecular Biology 2024Quote: ... was loaded on top of the gradient and spun at 4°C for 18 hr at 30,000 rpm (Beckman, Rotor SW-41Ti). Samples were fractionated with absorbance optics (λ = 260 nm ...
-
bioRxiv - Cancer Biology 2021Quote: ... 100,000xg for 3 h in an Optima XPN-80 (Beckman Coulter) ultracentrifuge using UltraClear Thinwall tubes ...
-
bioRxiv - Immunology 2023Quote: ... Lymphocytes were enumerated with a cell counter (Beckman Coulter Multisizer 3) set to detect nuclei between 3.5 and 10 μm ...
-
bioRxiv - Immunology 2023Quote: ... Lymphocytes were enumerated with a cell counter (Beckman Coulter Multisizer 3) set to detect nuclei between 3.5 and 10 μm.
-
bioRxiv - Immunology 2023Quote: ... Measurements were performed in a Gallios 10/3 cytometer (Beckman Coulter), using the Kaluza for Gallios Acquisition software (Version 1.0 ...
-
bioRxiv - Microbiology 2020Quote: ... by ultra-centrifugation in a Beckman L7-65 ultracentrifuge at 25,000 rpm for two hours at 4°C using a Beckman SW28 rotor (Beckman Coulter, Brea, CA, USA). Supernatants were aspirated off and the pellets were re-suspended in PBS (pH 7.4) ...
-
bioRxiv - Microbiology 2020Quote: ... by centrifugation in a Beckman L7-65 ultracentrifuge at 25,000 rpm for 2h at 4°C using a Beckman SW28 rotor (Beckman Coulter, Brea, CA, USA). Supernatants were aspirated and the pellets were re-suspended in PBS (pH 7.4) ...
-
bioRxiv - Molecular Biology 2021Quote: ... The centrifugation is performed on a SW60Ti rotor at 40 000 g for 22 minutes at 4°C (Beckman Optima L-90K Ultracentrifuge). The mitochondrial fraction (400µL ...
-
bioRxiv - Molecular Biology 2020Quote: ... and plasma was separated by centrifugation (2,000 × g, 20 min, 4 °C) in a Microfuge 20R (cat. no. B30149, Beckman Coulter, Brea, CA, USA). Plasma was transferred to new 1.5 mL microcentrifuge tubes and further clarified by centrifugation (10,000 × g ...
-
bioRxiv - Biophysics 2022Quote: ... shortly sonified and centrifuged for 30 min at 100 000 g at 4°C (Centrifuge Beckman Coulter Optima XPN-80, Rotor type 70.1).) ...
-
bioRxiv - Biophysics 2022Quote: ... The samples were centrifuged for 30 min at 100 000 g at 4°C (Centrifuge Beckman Coulter Optima XPN-80, Rotor type 70.1). The supernatant ...
-
bioRxiv - Microbiology 2020Quote: ... CLP assembly reactions were incubated at 25°C for 30 min before loading onto 15-30% (wt/wt) sucrose gradients and spinning at 159,599 X g for 43 min at 4°C (Beckman Coulter TLS 55 rotor). Gradients were immediately fractionated and aliquots of each fraction were denatured by boiling in 1% SDS to ensure antibody access ...
-
bioRxiv - Biochemistry 2020Quote: ... Unbroken cells were pelleted by centrifugation at 18,000 RCF for 30 min at 4°C (Beckman centrifuge J-20-XP, Rotor JA16.250, DE). The supernatant was transferred to 45 TI rotor (Beckman ...
-
bioRxiv - Bioengineering 2020Quote: ... and the supernatant was centrifuged again at 26000 × g at 4 °C for 15 min using an Optima L-90K (Beckman Coulter, Brea, CA) ultracentrifuge with a 70-Ti fixed angle rotor (Beckman Coulter) ...
-
bioRxiv - Biochemistry 2021Quote: ... supernatants were collected and centrifuged with 150.000 x g (at rav) for 30 min at 4 °C using an Optima™ MAX-XP Ultracentrifuge (Beckman Coulter; TLA120.2 rotor). Pellets were resuspended in PBS and 4 µg of primary antibody were added for 30 min ...
-
bioRxiv - Genomics 2021Quote: ... The spores were washed twice with sterile ddH2O and pelleted at 3700g for 5 min at 4 °C in an Allegra X-12R centrifuge (Beckman, Brea, CA, USA). Spores were resuspended in sterile ddH2O and kept at 4°C until experiments.
-
bioRxiv - Biochemistry 2020Quote: ... The sample was centrifuged at 4°C for 1 hour and 40 minutes at 182,753 x g (38,000 rpm in a Beckman Coulter Type 42.2 Ti rotor).
-
bioRxiv - Neuroscience 2021Quote: ... The resulting lysates were centrifuged at 100,000Xg for 30-60 min at 4°C in an Optima TLX tabletop ultracentrifuge using a TLA-110 rotor (Beckman Coulter, Fullerton, CA). The clarified supernatants were removed and transferred into the new tubes ...
-
bioRxiv - Biochemistry 2020Quote: ... Unbroken cells were pelleted by centrifugation at 18,000 RCF for 30 min at 4°C (Beckman centrifuge J-20-XP, Rotor JA16.250, DE). The supernatant was transferred to 45 TI rotor (Beckman ...
-
bioRxiv - Bioengineering 2021Quote: ... The samples were then centrifuged at 12,000 g for five minutes at 4°C to remove tissue debris with a Microfuge™ 22R centrifuge (Beckman Coulter, Brea, CA). The RNA was extracted using the Invitrogen PureLink™ RNA Mini Kit (Thermo Fisher ...
-
bioRxiv - Bioengineering 2021Quote: ... The tubes were then centrifuged at 1000 g for 15 minutes at 4°C using a Microfuge™ 22R (Beckman Coulter, Brea, CA), and the serum was then stored at -80°C ...
-
bioRxiv - Molecular Biology 2021Quote: ... 1 mM ATP and 1 mM PMSF) and centrifuged for 15 h at 4°C and 74 400 x g (Beckman SW 32.1 Ti). From the gradient ...
-
bioRxiv - Microbiology 2021Quote: ... resuspended in 150 μl 0.1 M HEPES/NAOH pH 7.0 and purified for 48 h (250,000 × g, 4 °C; Beckman Optima LE-80K, rotor SW60-Ti) using a CsCl gradient (0.45 g/ml ...
-
bioRxiv - Molecular Biology 2020Quote: ... and centrifuged at 10,000xg for 30 minutes at 4°C in a Beckman Coulter Optima XE-100 (fitted with a SW41Ti Rotor (Beckman Coulter, CA USA)) ...
-
bioRxiv - Biophysics 2022Quote: ... EVs were fractionated by OptiPrep density gradient ultracentrifugation (100,000 × g, 18 h, 4 °C) using a SW41 rotor (Beckman Coulter, Fullerton, CA, USA) through a continuous 5–40% OptiPrep (Sigma-Aldrich ...
-
bioRxiv - Immunology 2022Quote: ... followed by ultracentrifugation at 110,000 × g for 90 min at 4°C on an Optima XPN -100 ultracentrifuge with SW32Ti rotor (Beckman Coulter, Brea, CA, USA). The isolated EVs was washed with PBS and followed with a secondary ultracentrifugation (110,000 × g for 90 min at 4°C) ...
-
bioRxiv - Cell Biology 2021Quote: ... Cells were spun down at 4°C for 15 minutes at 4000 RPM (3040 RCF) in a J6 centrifuge (Beckman Coulter Life Sciences). Supernatant was discarded and pellets were stored in 15ml conical tubes in -80°C ...
-
bioRxiv - Biochemistry 2020Quote: ... Unbroken cells were pelleted by centrifugation at 18,000 RCF for 30 min at 4°C (Beckman centrifuge J-20-XP, Rotor JA16.250, DE). The supernatant was transferred to 45 Tl rotor (Beckman ...
-
bioRxiv - Pharmacology and Toxicology 2019Quote: ... for 10 m at 4°C and pelleted the lysates at 50,000×g for 1 h at 4°C using an Optima MAX-XP ultracentrifuge (Beckman Coulter, Brea, CA, USA). We resuspended cell fractions in 500 μL water and stored the samples at 4°C until analysis ...
-
bioRxiv - Microbiology 2021Quote: ... Ten milliliters of allantoic or amniotic fluid was centrifuged at maximum speed (16,000 × g) for 30 min at 4 °C using a floor ultra centrifuge (Beckman Optima L-60 Ultracentrifuge). After removal of the supernatant ...
-
bioRxiv - Microbiology 2019Quote: ... the extracts were added on top of layers in LCM buffer with 45% and 5% glycerol and ultracentrifuged at 77 000 x g for 1 h at +4°C (Beckman Coulter SW41Ti rotor). Viral nucleocapsids were recovered from the bottom of the ultracentrifuge tube ...
-
bioRxiv - Microbiology 2021Quote: ... the SBV samples were purified via sucrose density gradient centrifugation (10–50% range) at 32,500 rpm for 4 h with an SW 41 Ti Swinging-Bucket Rotor (Beckman Coulter Inc., Brea, CA). The SBV band that corresponded to the 40% sucrose gradient was harvested and then centrifuged at 25,000 rpm for 12 h ...
-
bioRxiv - Microbiology 2022Quote: ... The supernatant fractions were collected and centrifuged at 75,600 x g for 90 min at 4 °C (Beckman JA25.50 rotor, Beckman Avanati J-25, Beckman Coulter). The resulting pellets were washed again and resuspended in 500 μl potassium phosphate buffer ...
-
bioRxiv - Microbiology 2022Quote: ... 100 ml cell cultures were grown over night and harvested by centrifugation at 15,000 x g for 15 min at 4 °C (Beckman JLA-16.250 rotor, Beckman Avanti J-25, Beckman Coulter). Pellets were washed with 20 mM potassium phosphate (pH 7.5 ...
-
bioRxiv - Microbiology 2022Quote: ... then clarified by centrifugation at 2000 rpm at 4°C for 5 min in a refrigerated tabletop centrifuge (Beckman Coulter, Indianapolis IN, USA) to remove large debris ...
-
bioRxiv - Pharmacology and Toxicology 2024Quote: ... the cell lysate was layered on top of a discontinuous OptiPrep® gradient (50 %, 35 %, 30 %, 20 %, and 15 %) and centrifuged at 135,000 g for 1 h at 4°C (Beckman L8-80M Ultracentrifuge, USA). The melanin pellet was recovered ...
-
bioRxiv - Biochemistry 2023Quote: ... Expression was continued for 7h and the cells harvested by centrifugation at ∼6250g for 15 min at 4°C (Beckman Coulter centrifuge, JLA8.1000).
-
bioRxiv - Cell Biology 2024Quote: ... and centrifuged at 16,500 × g (14,500 rpm) at 4°C for 20 min using a Type Ti 45 fixed-angle rotor (Beckman Coulter, k-factor 1.275) to isolate large EVs ...
-
bioRxiv - Microbiology 2023Quote: ... cells were pelleted by centrifugation at 6,000 ×g at 4 °C for 15 min with ALLEGRA X-30R (Beckman Coulter, Brea, CA, USA). The supernatant was centrifuged at 15,000 ×g at 4 °C for 15 min with Sorvall LYNX4000 (Thermo Scientific ...
-
bioRxiv - Cancer Biology 2022Quote: ... the sample was centrifuged at 268,000 ×g at 4°C for 38 min with an MLA-50 rotor (Beckman Coulter, Brea, CA, USA). The top layer and subsequent 10 fractions (fractions 1–10 ...