Labshake search
Citations for Beckman :
951 - 1000 of 1820 citations for 1 6 Chloropyridazin 3 yl piperidine 4 carboxamide since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Systems Biology 2023Quote: ... Gradients were centrifuged at 4°C for 17 h at 100,000 g using an L7 ultracentrifuge with an SW28 swing out rotor (Beckman Coulter). Fractions (F ...
-
bioRxiv - Cell Biology 2023Quote: ... The iodixanol density gradients were centrifuged at 100,000 x g at 4◦C for 18 hours in SW41Ti rotor (Beckman Coulter). Ten fractions (F1 ...
-
bioRxiv - Cell Biology 2023Quote: ... Each fraction was subjected to a washing step in ice-cold PBS at 100,000 × g at 4°C for 2 h using a SW28Ti rotor (Beckman Coulter). The pelleted EVs were resuspended in ice-cold PBS ...
-
bioRxiv - Immunology 2022Quote: ... eVLPs were purified by ultracentrifugation at 50,000 rpm (135,000 x g) for 2 hours at 4°C using a TLA100.3 rotor and a OptimaTM TLX ultracentrifuge (Beckman Coulter) on a 20% w/v sucrose cushion ...
-
bioRxiv - Cell Biology 2023Quote: ... Lysates were cleared by centrifugation at 25 000 rpm for 45 min at 4°C in a Ti45 rotor (Beckman). Supernatant was incubated with 5 ml of Glutathione Sepharose 4B beads slurry (Cytiva ...
-
bioRxiv - Microbiology 2023Quote: ... The filtrate was ultracentrifuged at 100,000 ×g at 4 °C for 2 h using an Optima XE-90 (Beckman Coulter) to collect EMVs ...
-
bioRxiv - Neuroscience 2022Quote: ... The homogenised mixture then underwent ultracentrifugation at 200,000 g for 110 min at 4°C with a SW-41 Ti rotor (Beckman Coulter) and transferred the supernatant into a Slide-A-Lyzer™ G2 Dialysis Cassettes 2K MWCO (Thermo ...
-
bioRxiv - Cancer Biology 2023Quote: ... clarified by centrifugation at 20,000 rpm (48,385 x g) for 30 min in a JA25.50 rotor at 4 °C (Beckman AvantiTM J-25), filtered through a 0.8/0.2 AcroPak Filter Unit (Pall) ...
-
bioRxiv - Genomics 2023Quote: ... the supernatant was cleared by two rounds of centrifugation at 20,000 ×g (10 min, 4 °C, JA-20 rotor, Avanti J-26 XP, Beckman Coulter) followed by centrifugation at 31,900 ×g (10 min ...
-
bioRxiv - Genomics 2023Quote: ... Precipitated ribosomes were pelleted at 20,000 ×g (10 min, 4 °C, JA-20 rotor, Avanti J-26 XP, Beckman Coulter). To remove residual supernatant the pellet was re-centrifuged for 5 min at 20,000 ×g ...
-
bioRxiv - Genomics 2023Quote: ... The suspension was incubated on ice for 5 min and centrifuged at 20,000 ×g (10 min, 4 °C, JA-20 rotor, Avanti J-26 XP, Beckman Coulter). The pellet was re-centrifuged for 5 min and both supernatants were combined into a new tube ...
-
bioRxiv - Molecular Biology 2023Quote: ... then pelleted at 4°C and 4,300 x g for 30 min in an Allegra X-14R centrifuge (Beckman Coulter) equipped with a swinging bucket SX4750 rotor ...
-
bioRxiv - Plant Biology 2023Quote: ... The cAW was collected by spinning at 700 x g for 20 min at 4 ⁰C (JA-14 rotor, Beckman Coulter ...
-
bioRxiv - Genomics 2023Quote: ... The ribosomes were further purified by centrifugation at 59,727 ×g (15 hours, 4 °C, SW 32.1 Ti rotor, Optima™ L-100 XP, Beckman Coulter) in a linear (15 – 30 % ...
-
bioRxiv - Cancer Biology 2023Quote: ... Filtered supernatants were concentrated by ultracentrifugation at 22,000 rpm for 2 hours at 4°C with OptimaTM L-90K Ultracentrifuge (Beckman Coulter) and stored at -80°C (never refrozen).
-
bioRxiv - Systems Biology 2023Quote: ... The urine was centrifuged at 20,000 x g for 30 minutes at 4°C (k-factor 1,790) in an Optima XPN-80 ultracentrifuge (Beckman Coulter) equipped with a SW32 Ti swinging bucket rotor (Rmin 67 ...
-
bioRxiv - Molecular Biology 2023Quote: ... Cells were lysed by sonication and the lysate was clarified at 150,000 rcf for 30 min at 4°C using a Type 45 Ti Rotor (Beckman Coulter). The lysate was passed three times though 2mL of pre-equilibrated Ni-NTA Agarose beads (Qiagen ...
-
bioRxiv - Molecular Biology 2023Quote: ... Cells were lysed by sonication and the lysate was clarified at 150,000 rcf for 30 min at 4°C using a Type 45 Ti Rotor (Beckman Coulter). The lysate was passed three times through 2 mL of pre-equilibrated Ni-NTA Agarose beads (Qiagen ...
-
bioRxiv - Molecular Biology 2023Quote: ... The lysate was clarified at 150,000 rcf for 45 min at 4°C using a Type 45 Ti Rotor (Beckman Coulter). The supernatant was incubated with 3 mL IgG Sepharose 6 Fast Flow beads (Cytiva ...
-
bioRxiv - Molecular Biology 2023Quote: ... The lysate was clarified at 150,000 rcf for 30 min at 4°C using a Type 45 Ti Rotor (Beckman Coulter). The supernatant was incubated with 3 mL IgG Sepharose 6 Fast Flow beads (Cytiva ...
-
bioRxiv - Molecular Biology 2023Quote: ... The lysate was clarified at 503,000 rcf for 45 min at 4°C using a Type 70 Ti Rotor (Beckman Coulter). The supernatant was incubated with 3 mL IgG Sepharose 6 Fast Flow beads (Cytiva ...
-
bioRxiv - Cell Biology 2023Quote: ... the post-nuclear supernatant was centrifuged for 30 min at 100,000 x g at 4°C using a S120AT2 rotor (Beckman Coulter). The resulting pellet containing the membranes was resuspended in SDS sample buffer (see below).
-
bioRxiv - Cell Biology 2023Quote: ... 355647) and centrifuged at 35,000 rpm (100,000xg) for 40min at 4°C (Fixed-angle rotor, Beckman Coulter Optima Max Unltracentrifuge). 100K pellet (sEVs ...
-
bioRxiv - Plant Biology 2023Quote: ... Approximately 250 µl of crude EV sample resuspended in 20 mM Tris-HCl pH 6.0 was slowly dispensed on top of the column and centrifuged at 100,000 x g for 17 h at 4 ⁰C (SW 41 Ti rotor, Beckman Coulter; OptimaTM L-90K, Beckman Coulter). After the ultracentrifugation ...
-
bioRxiv - Plant Biology 2023Quote: ... The resulting solution was then centrifuged again at 39,800 x g for 2 h at 4 ⁰C (JA-17 rotor, Avanti J-20TM centrifuge, Beckman Coulter). The supernatant was decanted ...
-
bioRxiv - Plant Biology 2023Quote: ... The supernatant from this step was decanted into the new tubes and centrifuged at 39,800 x g for 2 h at 4 ⁰C (JA-17 rotor, Beckman Coulter; Avanti J-20TM centrifuge, Beckman Coulter). The supernatant was then decanted and discarded ...
-
bioRxiv - Neuroscience 2022Quote: ... trypsin-dissociated cells on 96-well plates were centrifuged at 1,000g for 5 min at 4°C using a swinging-bucket rotor for microplates (Beckman S6096) in an Allegra X-30R centrifuge (Beckman) ...
-
SARS-CoV2 associated secretion of nanoLuciferase reports on virus and Virus-Like Particle productionbioRxiv - Molecular Biology 2022Quote: ... the samples were pelleted through a 20% sucrose in 120 mM HEPES cushion at 100,000xg for 2hrs at 4 °C with 45 Ti or 70 Ti fixed-angle rotor (Beckman-Coulter) depending on the volume of the sample ...
-
bioRxiv - Molecular Biology 2022Quote: ... and the sucrose cushion was ultra-centrifuged for 1.5 hours at 80000 rpm and 4°C in TLA-100 rotor (Beckman Coulter). The pellet was resuspended in 100 µL of buffer F (50 mM HEPES-KOH pH 7.4 ...
-
bioRxiv - Cell Biology 2022Quote: ... and the post-nuclear supernatant was loaded onto an 8-step discontinuous sucrose density gradient (HEPES-buffered 0.2–2 M sucrose) and centrifuged at 55,000 rpm for 2h at 4 °C using an MLS50 rotor (Beckman Coulter). Extracellular acidification rate (ECAR ...
-
bioRxiv - Molecular Biology 2024Quote: ... the rest was loaded on top of sucrose gradient and ultracentrifuged (30000 rpm, 4°C, 18h, stop DECEL, slow, SW40/1Ti swinging bucket rotor, Optime L-90K, Beckman). 24 fractions were taken from top to bottom of the tube as 500 µL aliquots and precipitated by incubation with 50 µL of 0.15% sodium deoxycholate for 10 min at RT ...
-
bioRxiv - Genomics 2023Quote: ... 1x protease inhibitor cocktail EDTA-free) by spinning at 38,000 rpm at 4 °C in a SW-41 Ti rotor (Beckman Coulter). Monosome pellets were resuspended in 400 µL lysis buffer and rocked overnight ...
-
bioRxiv - Biophysics 2024Quote: ... and subjected to ultracentrifugation at 384,492□g for 45□min at 4□°C (Beckman Coulter Optima MAX, TLA-100 rotor), stored at −80 °C after flash-frozen with liquid nitrogen for crystallization trials ...
-
bioRxiv - Biochemistry 2024Quote: ... The protein samples were carefully applied to the gradient and centrifuged for 16 h at 130,000 g at 4 °C (Optima XPN-80 Ultracentrifugation from Beckman Coulter). 200 µl fractions were taken from the top of the gradient and the glutaraldehyde quenched with 20 mM Tris pH 7.5 ...
-
bioRxiv - Biochemistry 2024Quote: ... The homogenate was clarified by centrifugation for 30 min at 70,560 × g at 4°C in an Optima XPN Ultracentrifuge (Beckman Coulter) using a Ti-45 rotor ...
-
bioRxiv - Neuroscience 2024Quote: ... Samples were centrifuged at 30,000 xg for 45 min at 4 °C using a SW41 Ti swinging bucket rotor (Beckman Coulter) before the supernatant was decanted ...
-
bioRxiv - Neuroscience 2024Quote: ... The homogenate was centrifuged (45 min, 16 000 rpm, 4°C, JLA 16.250 rotor, Beckman-Coulter Centrifuge Avanti J25-01) and the supernatant subjected to Ni-NTA affinity purification (HIS-Select Nickel Affinity Gel (Sigma Aldrich)) ...
-
bioRxiv - Cell Biology 2024Quote: ... Gradients were centrifuged at 36,000 rpm for 2 h at 4 °C in an Optima L-100XP ultracentrifuge (Beckman–Coulter). Following centrifugation ...
-
bioRxiv - Biochemistry 2023Quote: ... The gradient was centrifuged for 2.30 hours at 4 °C and 111,000 ×g in a swing-out rotor (Beckman- Coulter, SW41). The brownish lysosome-enriched fraction (∼ 1ml ...
-
bioRxiv - Cancer Biology 2023Quote: ... The gradients were ultracentrifuged at 35,000 rpm for 2 hrs at 4°C using an SW41 Ti rotor (Beckman Coulter). The gradients were then displaced into a UA-6 continuous UV detector (Teledyne ISCO ...
-
bioRxiv - Cell Biology 2023Quote: ... Small EVs were isolated by ultracentrifugation at 120,000 x g and 4°C for 120 min using Optima XE-90 equipment with a SW32Ti rotor (Beckman Coulter). Supernatants were discarded using a pipette ...
-
Centriole and transition zone structures in photoreceptor cilia revealed by cryo-electron tomographybioRxiv - Cell Biology 2023Quote: ... OptiPrep step-gradient and centrifuged for 60 min at 19,210 × g at 4 °C in a TLS-55 rotor (Beckman Coulter). The ROS band was collected with an 18G needle ...
-
bioRxiv - Cell Biology 2023Quote: ... The gradient was centrifuged at 4 °C and 100,000 ˗ g for 18 h (Optima L-80 XP Ultracentrifuge with Swing Rotor (Beckman Coulter)) ...
-
bioRxiv - Developmental Biology 2023Quote: ... The resulting supernatant was subjected to ultracentrifugation at 120,000 × g at 4°C for 2 h (Optima Max TL, Beckman Coulter). Pellets were resuspended in 1 ml cold PBS and centrifuged at 120,000 × g at 4°C for 2 h ...
-
bioRxiv - Immunology 2023Quote: ... and purified and concentrated by ultracentrifugation on a 20% sucrose cushion (24,000 rpm and 4°C for 2 hours with a SW32Ti or SW28 rotor (Beckman Coulter)) ...
-
bioRxiv - Neuroscience 2023Quote: ... and samples were centrifuged at 24,000 rpm at 4°C for 1h in a SW41Ti Swinging-Bucket Rotor (Beckman Coulter). After discarding the supernatant ...
-
bioRxiv - Cell Biology 2023Quote: ... The samples were sedimented by velocity centrifugation at 36,000 x rpm for 2 h at 4°C using SW40Ti rotor in Optima L-80XP ultracentrifuge (Beckman Coulter). Absorbance at 254 nm was measured from lower to higher sucrose gradients using an ISCO gradient fractionation system and the optical density at 254 nm was continuously recorded with a Foxy JR Fractionator (Teledyne ISCO).
-
bioRxiv - Cell Biology 2024Quote: ... The step gradients were centrifuged for 5 h at 132.000 x g at 4 °C (SW60 Beckman and Coulter, # 335649). Subsequently ...
-
bioRxiv - Cell Biology 2024Quote: ... The same amounts of proteins were loaded on a double sucrose cushion (20% and 30% sucrose) and centrifuged at 190,000 g for 2 h at 4 °C in an Optima L-100XP ultracentrifuge (Beckman–Coulter). Extracts were incubated with pre-washed anti-Flag beads (Sigma ...
-
bioRxiv - Immunology 2023Quote: ... virus solutions were clarified of debris by centrifugation at 10,000 rpm at 4°C for 30 minutes in a chilled SW32Ti rotor (Beckman Coulter), followed by pelleting through a 30% cold sucrose solution at 25,000 rpm for 90 minutes ...