851 - 900 of 1841 citations for 1 tert Butoxy 4 methyl 2 nitrobenzene since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Plant Biology 2020Quote: ... the cells were harvested by centrifuging for 30 min at 4°C and 6,000 rpm (JA-10, Beckman Coulter®). The cells were resuspended in 1x PBS (pH 7.3 ...
-
bioRxiv - Genomics 2021Quote: ... The tubes were then balanced and centrifuged in a Beckman Coulter L7-65 Ultracentrifuge at 25,000rpm at 4°C for 2hr using a Beckman Coulter SW28 swing bucket rotor (Beckman Coulter). The supernatant was carefully removed via aspiration ...
-
bioRxiv - Molecular Biology 2020Quote: ... by centrifuging at 63,000 x g for 18 hrs at 4°C using a Type 80 Ti rotor (Beckman Coulter). Pellets were resuspended and these samples were analysed by mass spectrometry.
-
bioRxiv - Immunology 2021Quote: ... Ultracentrifugation in a Beckman L7-65 ultracentrifuge at 25,000 rpm for two hours at 4°C using a Beckman SW28 rotor (Beckman Coulter) was performed to pellet the viruses through the sucrose cushion while soluble egg proteins were removed ...
-
bioRxiv - Cell Biology 2020Quote: ... The ultracentrifugation (UC) steps were performed in refrigerated conditions (4°C) with rotors 50.4Ti or 70Ti (Beckman-Coulter, California, US).
-
bioRxiv - Physiology 2021Quote: ... the supernatant was ultracentrifuged at 100,000 g for 70 min at 4°C using an MLA-55 rotor (Beckman Coulter) and an Optima MAX-TL Ultracentrifuge (Beckman Coulter) ...
-
bioRxiv - Biochemistry 2021Quote: ... Samples were ultracentrifuged at 120,000 × g for 90 minutes at 4 °C in an Optima XPN-80 ultracentrifuge (Beckman Coulter) using a SW55 Ti swinging-bucket rotor (Beckman Coulter) ...
-
bioRxiv - Biochemistry 2021Quote: ... and cellular debris was removed by centrifugation at 90 000 x g for 20 min at 4°C (45 Ti rotor, Beckman). Membranes were collected by ultracentrifugation at 220 000 x g for 90 min at 4°C (45Ti rotor ...
-
bioRxiv - Cell Biology 2020Quote: ... This crude mitochondrial pellet was further purified on a discontinuous percoll gradient (buffer composition 15/23/40% sucrose) by centrifugation (40,000 x g, 1hr, 4°C) in an SW41 rotor (Beckman Coulter) and enriched mitochondria were collected from the 23-40% interface (adapted from [76]) ...
-
bioRxiv - Cell Biology 2020Quote: ... Tubes were centrifuged twice at 100,000 x g for 70 min at 4°C with a Beckman ultracentrifuge (32Ti rotor from Beckman Coulter). Supernatants were removed and the pellets resuspended in phosphate-buffered saline (PBS ...
-
bioRxiv - Microbiology 2020Quote: ... Microbial cells were collected from to 2-3 L of water samples by centrifugation at 12,000 × g and 4°C for 20 min in a high-speed centrifuge (Beckman, USA). Total genomic DNA was extracted using AxyPrep™ Genomic DNA Miniprep Kit (Axygen ...
-
bioRxiv - Microbiology 2020Quote: ... Two distinct fractions were collected from the first CsCl density gradient centrifugation (17,000 × g, 60 min, 4°C in a fixed angle MLA-55 rotor, Beckman Coulter), each were sedimented (4000 × g ...
-
bioRxiv - Molecular Biology 2021Quote: ... lysates were spun for 24 h at 4°C at 50000 rpm in a Type 70 Ti rotor (Beckman Coulter) through a 40 % (w/v ...
-
bioRxiv - Microbiology 2021Quote: ... purified by ultracentrifugation through a sucrose cushion (25% weight/volume in Tris-NaCl-EDTA buffer) for 75 min at 4°C and 28,000 rpm using a SW 32 TI rotor (Beckman Coulter), resuspended in serum-free RPMI 1640 or DMEM medium and stored in small aliquots at −80°C ...
-
bioRxiv - Immunology 2020Quote: ... previously coated over-night at 4 °C with 1.5 μg per well of anti-Igκ or anti-IgM (Beckman Coulter) in PBS and saturated with culture medium ...
-
bioRxiv - Microbiology 2021Quote: ... The resting supernatants were filtered through 0.45µm syringe filters and ultracentrifuged at 100,000 x g for 1h at 4°C (SW41 Ti swinging-bucket rotor, Beckman Coulter). The supernatant was discarded and the pellet suspended in 0.22 µm-pore filtered or 0.02 µm-pore filtered (for Flow Cytometry analysis ...
-
bioRxiv - Systems Biology 2023Quote: ... Gradients were centrifuged at 4°C for 17 h at 100,000 g using an L7 ultracentrifuge with an SW28 swing out rotor (Beckman Coulter). Fractions (F ...
-
bioRxiv - Synthetic Biology 2023Quote: ... The gradients were ultra-centrifuged at 41,000 rpm for 3 hours at 4°C (Optima L-80 XP ultracentrifuge (Beckman-Coulter)) ...
-
bioRxiv - Cell Biology 2022Quote: ... The supernatant was centrifuged at 300,000×g at 4°C for 3 h in a TLA-110 fixed angle rotor (k-factor 13) (Beckman Coulter). The pellet was resuspended in 10 µL PBS of which 3 µL was adsorbed onto glow-discharged 2 nm carbon layer coated Quantifoil R1.2/1.3 400 mesh gold grids ...
-
bioRxiv - Cell Biology 2023Quote: ... The iodixanol density gradients were centrifuged at 100,000 x g at 4◦C for 18 hours in SW41Ti rotor (Beckman Coulter). Ten fractions (F1 ...
-
bioRxiv - Cell Biology 2023Quote: ... Lysates were cleared by centrifugation at 25 000 rpm for 45 min at 4°C in a Ti45 rotor (Beckman). Supernatant was incubated with 5 ml of Glutathione Sepharose 4B beads slurry (Cytiva ...
-
bioRxiv - Neuroscience 2022Quote: ... The homogenised mixture then underwent ultracentrifugation at 200,000 g for 110 min at 4°C with a SW-41 Ti rotor (Beckman Coulter) and transferred the supernatant into a Slide-A-Lyzer™ G2 Dialysis Cassettes 2K MWCO (Thermo ...
-
bioRxiv - Molecular Biology 2023Quote: 8 mL of viral supernatant on a 3 mL of 20% sucrose cushion were ultracentrifugated for 3 h at 100,000 x g at 4°C using an Optima L80-XP instrument (Beckman Coulter). After ultracentrifugation ...
-
bioRxiv - Cancer Biology 2023Quote: ... clarified by centrifugation at 20,000 rpm (48,385 x g) for 30 min in a JA25.50 rotor at 4 °C (Beckman AvantiTM J-25), filtered through a 0.8/0.2 AcroPak Filter Unit (Pall) ...
-
bioRxiv - Cancer Biology 2023Quote: ... cells were seeded into 6-well plates at a concentration of 4×105 cells per well and counted cumulatively with a Coulter counter (Beckman) every three days for two weeks ...
-
bioRxiv - Genomics 2023Quote: ... the supernatant was cleared by two rounds of centrifugation at 20,000 ×g (10 min, 4 °C, JA-20 rotor, Avanti J-26 XP, Beckman Coulter) followed by centrifugation at 31,900 ×g (10 min ...
-
bioRxiv - Genomics 2023Quote: ... Precipitated ribosomes were pelleted at 20,000 ×g (10 min, 4 °C, JA-20 rotor, Avanti J-26 XP, Beckman Coulter). To remove residual supernatant the pellet was re-centrifuged for 5 min at 20,000 ×g ...
-
bioRxiv - Genomics 2023Quote: ... The suspension was incubated on ice for 5 min and centrifuged at 20,000 ×g (10 min, 4 °C, JA-20 rotor, Avanti J-26 XP, Beckman Coulter). The pellet was re-centrifuged for 5 min and both supernatants were combined into a new tube ...
-
bioRxiv - Molecular Biology 2023Quote: ... then pelleted at 4°C and 4,300 x g for 30 min in an Allegra X-14R centrifuge (Beckman Coulter) equipped with a swinging bucket SX4750 rotor ...
-
bioRxiv - Plant Biology 2023Quote: ... The cAW was collected by spinning at 700 x g for 20 min at 4 ⁰C (JA-14 rotor, Beckman Coulter ...
-
bioRxiv - Genomics 2023Quote: ... The ribosomes were further purified by centrifugation at 59,727 ×g (15 hours, 4 °C, SW 32.1 Ti rotor, Optima™ L-100 XP, Beckman Coulter) in a linear (15 – 30 % ...
-
bioRxiv - Systems Biology 2023Quote: ... The urine was centrifuged at 20,000 x g for 30 minutes at 4°C (k-factor 1,790) in an Optima XPN-80 ultracentrifuge (Beckman Coulter) equipped with a SW32 Ti swinging bucket rotor (Rmin 67 ...
-
bioRxiv - Molecular Biology 2023Quote: ... Cells were lysed by sonication and the lysate was clarified at 150,000 rcf for 30 min at 4°C using a Type 45 Ti Rotor (Beckman Coulter). The lysate was passed three times though 2mL of pre-equilibrated Ni-NTA Agarose beads (Qiagen ...
-
bioRxiv - Molecular Biology 2023Quote: ... Cells were lysed by sonication and the lysate was clarified at 150,000 rcf for 30 min at 4°C using a Type 45 Ti Rotor (Beckman Coulter). The lysate was passed three times through 2 mL of pre-equilibrated Ni-NTA Agarose beads (Qiagen ...
-
bioRxiv - Molecular Biology 2023Quote: ... The lysate was clarified at 150,000 rcf for 45 min at 4°C using a Type 45 Ti Rotor (Beckman Coulter). The supernatant was incubated with 3 mL IgG Sepharose 6 Fast Flow beads (Cytiva ...
-
bioRxiv - Molecular Biology 2023Quote: ... The lysate was clarified at 150,000 rcf for 30 min at 4°C using a Type 45 Ti Rotor (Beckman Coulter). The supernatant was incubated with 3 mL IgG Sepharose 6 Fast Flow beads (Cytiva ...
-
bioRxiv - Molecular Biology 2023Quote: ... The lysate was clarified at 503,000 rcf for 45 min at 4°C using a Type 70 Ti Rotor (Beckman Coulter). The supernatant was incubated with 3 mL IgG Sepharose 6 Fast Flow beads (Cytiva ...
-
bioRxiv - Microbiology 2023Quote: ... Each tube was centrifuged for 3 hours at 150’000 x g (4°C) using an Optima XPN-80 ultracentrifuge (Beckman Coulter) equipped with a SW 32 Ti swinging bucket (369650 ...
-
bioRxiv - Cell Biology 2023Quote: ... The obtained supernatant was layered onto 30 w/v% sucrose solution in ultracentrifugation tubes and subjected to ultracentrifugation at 100,000 × g for 3 h at 4°C using SW32Ti rotor (Beckman courter). The collected sucrose solutions were mixed with PBS and washed by ultracentrifugation at 100,000 × g for 1 h ...
-
bioRxiv - Cell Biology 2023Quote: ... the post-nuclear supernatant was centrifuged for 30 min at 100,000 x g at 4°C using a S120AT2 rotor (Beckman Coulter). The resulting pellet containing the membranes was resuspended in SDS sample buffer (see below).
-
bioRxiv - Cell Biology 2023Quote: ... 355647) and centrifuged at 35,000 rpm (100,000xg) for 40min at 4°C (Fixed-angle rotor, Beckman Coulter Optima Max Unltracentrifuge). 100K pellet (sEVs ...
-
bioRxiv - Plant Biology 2023Quote: ... Approximately 250 µl of crude EV sample resuspended in 20 mM Tris-HCl pH 6.0 was slowly dispensed on top of the column and centrifuged at 100,000 x g for 17 h at 4 ⁰C (SW 41 Ti rotor, Beckman Coulter; OptimaTM L-90K, Beckman Coulter). After the ultracentrifugation ...
-
bioRxiv - Neuroscience 2022Quote: ... trypsin-dissociated cells on 96-well plates were centrifuged at 1,000g for 5 min at 4°C using a swinging-bucket rotor for microplates (Beckman S6096) in an Allegra X-30R centrifuge (Beckman) ...
-
SARS-CoV2 associated secretion of nanoLuciferase reports on virus and Virus-Like Particle productionbioRxiv - Molecular Biology 2022Quote: ... the samples were pelleted through a 20% sucrose in 120 mM HEPES cushion at 100,000xg for 2hrs at 4 °C with 45 Ti or 70 Ti fixed-angle rotor (Beckman-Coulter) depending on the volume of the sample ...
-
bioRxiv - Molecular Biology 2022Quote: ... The gradients were ultra-centrifuged for 3 h at 175,000g at 4°C in a SW41Ti rotor (Beckman-Coulter, USA) and analyzed by measuring the absorbance continuously at 260 nm using a piston gradient fractionator (Biocomp Instruments) ...
-
bioRxiv - Molecular Biology 2022Quote: ... and spun at 40,000 rpm for 3 hours at 4°C using a SW 41 Ti Swinging-Bucket Rotor (Beckman Coulter). Sucrose gradient fractionation was performed by using a Brandel Density Gradient Fractionation System ...
-
bioRxiv - Molecular Biology 2022Quote: ... and the sucrose cushion was ultra-centrifuged for 1.5 hours at 80000 rpm and 4°C in TLA-100 rotor (Beckman Coulter). The pellet was resuspended in 100 µL of buffer F (50 mM HEPES-KOH pH 7.4 ...
-
bioRxiv - Molecular Biology 2024Quote: ... the rest was loaded on top of sucrose gradient and ultracentrifuged (30000 rpm, 4°C, 18h, stop DECEL, slow, SW40/1Ti swinging bucket rotor, Optime L-90K, Beckman). 24 fractions were taken from top to bottom of the tube as 500 µL aliquots and precipitated by incubation with 50 µL of 0.15% sodium deoxycholate for 10 min at RT ...
-
bioRxiv - Genomics 2023Quote: ... 1x protease inhibitor cocktail EDTA-free) by spinning at 38,000 rpm at 4 °C in a SW-41 Ti rotor (Beckman Coulter). Monosome pellets were resuspended in 400 µL lysis buffer and rocked overnight ...
-
bioRxiv - Biophysics 2024Quote: ... and subjected to ultracentrifugation at 384,492□g for 45□min at 4□°C (Beckman Coulter Optima MAX, TLA-100 rotor), stored at −80 °C after flash-frozen with liquid nitrogen for crystallization trials ...