bioRxiv - Plant Biology 2020Quote: ... The loaded density gradients were centrifuged at 33,000 g for 14.5 h at 4°C using a six-position SW41 Ti rotor (Beckman Coulter, Kerfeld, Germany). The positions of ribosome complexes varied slightly with each centrifugation run that comprised a set of six samples ...
-
bioRxiv - Bioengineering 2020Quote: ... Ultracentrifugation was performed at 100,000 x g at 4 C for 45 min in an Optima MAX-XP ultracentrifuge (Beckman Coulter, Inc.). Supernatant was discarded ...
-
bioRxiv - Biochemistry 2020Quote: ... in BC300N buffer and centrifuged for 4hr at 55,000rpm at 4°C in a TLS-55 rotor (with Beckman 356860 adaptors). 40µl fractions were collected by pipetting from the top ...
-
bioRxiv - Biophysics 2021Quote: Purified 3C DNA from each sample was sonicated to 200-400 bp with a Soniprep 150 probe sonicator at 4°C and purified with a standard Ampure XP Bead protocol (Beckman Coulter) using a 1/1.5 DNA to bead ratio ...
-
bioRxiv - Neuroscience 2020Quote: ... The supernatant was then collected and subjected to ultracentrifugation at 100,000 x g for 70 min at 4°C using an Optima XPN-80 ultracentrifuge with SW 32 Ti swinging rotor (Beckman Coulter). Pellets were washed in PBS 1X and EVs were subjected to an additional centrifugation at 100,000 x g for 30 min at 4°C using an Optima MAX ultracentrifuge ...
-
bioRxiv - Neuroscience 2020Quote: ... centrifuged at 100,000 g for 70 min at 4°C using an Optima XPN-80 ultracentrifuge with SW 32 Ti swinging rotor (Beckman Coulter) and then processed for further analyses.
-
bioRxiv - Plant Biology 2021Quote: ... Syringes were placed inside 50-mL tubes and centrifuged for 20 min at 700g with slow acceleration (4°C, JA-14 rotor, Avanti J-20 XP Centrifuge; Beckman Coulter). The apoplastic wash fluid was then filtered through a 0.22 μm membrane and centrifuged at 10,000g for 30 minutes to remove any remaining large particles ...
-
bioRxiv - Biochemistry 2021Quote: ... 2 mM DTT) and centrifuged for 2 hours and 15 minutes at 39000 rpm at 4°C (Beckman Coulter TLS55 rotor). Fractions corresponding to the large mitochondrial subunit were collected and subjected to buffer exchange (25 mM HEPES-KOH pH = 7.5 ...
-
bioRxiv - Microbiology 2021Quote: ... cells were fixed with 4% Paraformaldehyde for 30 minutes at room temperature and analyzed for GFP fluorescence on a Gallios flow cytometer (Beckman-Coulter). For SARS-CoV-2 experiments ...
-
bioRxiv - Molecular Biology 2021Quote: ... and spung for 20hrs at 151,000 x g (rav) at 4°C in a swinging bucket rotor (Beckman SW-41 Ti). 12 1ml fractions were taken off the gradient and incubated for 10min at RT with 100μl 0.15% deoxycholine ...
-
bioRxiv - Microbiology 2021Quote: ... and cytoplasmic membranes were precipitated by ultracentrifugation for 45 min at 55,000 rpm and 4°C (Beckman Coulter rotor TLA 55). Membrane fractions resuspended in resuspension buffer (750 mM aminocaproic acid ...
-
bioRxiv - Biophysics 2021Quote: ... The crude lysate was sonicated on ice and clarified by centrifugation for 30 min at 4°C and 35,000 rpm in a Beckman L90K Optima and 50.2 Ti rotor (Beckman, Brea, CA, USA). The clarified lysate was applied to a HisTrapHP column (Cytiva ...
-
bioRxiv - Biophysics 2021Quote: ... and the fractions containing the protein of interest were combined and concentrated to 2mL at a final concentration of 3.85 mg/mL by repeated centrifugation in an Amicon Ultra Centrifugal Filter at 4k rpm for 5 min at 4 °C (Beckman SX4250). The concentrated protein was incubated overnight with TEV (1:50 mass ratio ...
-
bioRxiv - Cancer Biology 2022Quote: ... vehicle control or compounds from the small molecule library (Supplementary Table 4) were added using an Echo liquid handler (Labcyte/Beckman Coulter). Cells were then incubated in an IncuCyte Zoom (Sartorius ...
-
bioRxiv - Microbiology 2022Quote: ... Most of the supernatant was discarded leaving 12x∼200 µL of concentrated fibers that were pooled and layered on top of ultracentrifuge tubes of 4 mL (polypropylene centrifuge tubes, Beckman Coulter) containing a discontinuous sucrose gradient (40% ...
-
bioRxiv - Biophysics 2022Quote: ... and the supernatant was subjected to ultracentrifugation to separate the membrane fraction (100,000g, 1 hour, 4°C using an Optima XE-90, Beckman Coulter centrifuge). Membranes were resuspended in lysis buffer supplemented with cOmplete EDTA-free protease inhibitors (Roche) ...
-
bioRxiv - Microbiology 2022Quote: ... through a syringe needle (0.4-by 20 mm needles) and the cell wall was collected by ultracentrifugation at 90,000 × g for 45 min at 4°C (Beckman Coulter, Inc.). To the pellet ...
-
bioRxiv - Bioengineering 2022Quote: ... The final supernatant was collected and EVs were pelleted at 100,000 g at 4°C for four hours in an Optima ultracentrifuge using the Beckman Ti45 rotor (Beckman Coulter, USA). The EVs pellet was washed with PBS and resuspended in 0.22 μm filtered PBS ...
-
bioRxiv - Cell Biology 2022Quote: ... A new supernatant was collected in a prechilled 1.5 ml ultracentrifuge tube and centrifuged at 100000 g for 1 h at 4°C in a TLA-55 rotor (Beckman Coulter). The resulting pellet was resuspended in the same isotonic buffer containing antiproteases and was frozen at -80°C together with the 100000 g supernatant ...
-
bioRxiv - Microbiology 2021Quote: ... Cell supernatants containing the pseudotype viral particles were centrifuged at 109,000 g or 35 min at 4 °C using a TLA100.3 rotor with an Optima TLX ultracentrifuge (Beckman Coulter, CA, USA), and the pellet was then lysed for western blotting analysis.
-
Adaptive translational pausing is a hallmark of the cellular response to severe environmental stressbioRxiv - Molecular Biology 2020Quote: ... and centrifuged at 4°C at 31,000 rpm for 2 h and 30 min using an SW 32 Ti rotor(Beckman Coulter, 369694). The gradients were fractionated using a Teledyne ISCO Density Gradient Fractionation System and 12 fractions were collected ...
-
bioRxiv - Molecular Biology 2020Quote: ... The filtered supernatant was then centrifuged in JA20 tubes at 6000 rpm overnight (O/N) at 4°C (Avanti J-25, Beckman Coulter). The following day the viral pellet was resuspended in 5 ml PBS and centrifuged at 20,000 rpm for 90 mins at 4°C (Optima XL-100K ...
-
bioRxiv - Molecular Biology 2020Quote: ... The gradients were centrifuged at 40000 rpm for 2h at 4°C in a SW 60 Ti swinging-bucket rotor (Beckman Coulter). Afterwards ...
-
bioRxiv - Cell Biology 2021Quote: ... and centrifuged at 100,000 g at 4°C for 60 min in a swinging rotor (SW40Ti) (Beckman Coulter OptimaTM L–100K). Following centrifugation ...
-
Single cell analysis of the cellular heterogeneity and interactions in the injured mouse spinal cordbioRxiv - Neuroscience 2020Quote: ... were added to each sample well and cells were kept at 4°C until analysis on a Cytoflex Flow Cytometer (Beckman Coulter).
-
bioRxiv - Cell Biology 2020Quote: ... were pelleted in Beckman Coulter polypropylene open top tubes (110,000 x g for 70 min at 4°C, in Beckman rotor SW28). After washing ...
-
bioRxiv - Immunology 2021Quote: ... 4 ng of RNA were retrotranscribed and cDNA was amplified using 13 cycles and purified with AMPure XP beads (Beckman Coulter). Concentration was determined using Qubit 3.0 (Life Technologies ...
-
bioRxiv - Cancer Biology 2020Quote: ... cells were grown for 4-6 days and counted using an Incucyte (Essen Biosciences) or a Z2 Coulter Counter (Beckman Coulter). Small molecule dose-response curves were printed using an D300e Digital Dispenser (HP Specialty Printing Systems ...
-
bioRxiv - Microbiology 2022Quote: ... and the viral particles were concentrated by ultracentrifugation for 1h at 30,000 rpm at 4°C in an SW40 rotor (Beckman, Fullerton, CA). Viral pellets were resuspended in TNC buffer (10 mM Tris-HCl [pH 7.5] ...
-
bioRxiv - Neuroscience 2022Quote: ... dispersed and collected in a single tube and further centrifuged for 4 hours at 21000 rpm in a 20% sucrose gradient (SW55 Beckman rotor). The resulting pellet was suspended in 100 μl PBS and the virus was aliquoted (5-10 μl ...
-
bioRxiv - Cancer Biology 2022Quote: ... Crude vesicle pellets were resuspended in 1 ml of exosome-depleted 1X PBS and re-pelleted by centrifugation at 100,000 g for 70 minutes at 4°C (Beckman 45 Ti). Pellets at the bottom of the centrifugation tubes were resuspended in approximately 50ul of 1X PBS ...
-
bioRxiv - Systems Biology 2020Quote: ... The resultant supernatant was collected and underwent ultracentrifugation at 100,000xg for 40 minutes at 4°C (rotor MLA-55) in 10.4 ml 16×76 mm polycarbonate capped centrifuge tubes (Beckman Coulter 355603), the pellet was washed once in PBS−/− and centrifuged again at 100,000xg for 40 minutes at 4°C ...
-
bioRxiv - Molecular Biology 2019Quote: ... EDS was obtained after 18 h ultracentrifugation at 100,000 g and 4 °C (SW55 Ti rotor, Beckman Coulter, Fullerton, California, USA), followed by 0.22 µm filtration ...
-
bioRxiv - Molecular Biology 2019Quote: ... followed by 3 h ultracentrifugation at 100,000 g and 4 °C using SW 32.1 Ti rotor (Beckman Coulter, Fullerton, California, USA). Resulting pellets were resuspended in 100 µl PBS and stored at −80 °C until further use ...
-
bioRxiv - Microbiology 2019Quote: ... The concentrated vesicles were washed twice with PBS by ultracentrifugation at 110,000xg at 4°C for 1 hour (Beckman Optma MAX-XP Ultracentrifuge, rotor TLA 120.2; Beckman Coulter Inc., USA). The final pellet (exosomes ...
-
The antibiotic bedaquiline activates host macrophage innate immune resistance to bacterial infectionbioRxiv - Immunology 2019Quote: ... Cells were detached and were fixed with 4% paraformaldehyde and the fluorescence was analyzed using a CytoFLEX Flow Cytometer (Beckman Coulter).
-
bioRxiv - Cancer Biology 2019Quote: ... Gradients were ultra-centrifuged at 221,600 × g for 2 hours at 4°C (SW-41Ti rotor, 331362, Beckman Coulter, Brea, CA). Gradients were fractionated (Piston Fractionator ...
-
bioRxiv - Cell Biology 2020Quote: ... Reconstituted nucleosome samples were overlaid onto the sucrose gradient and spun at 32000 rpm for 20 h at 4 ° using SW55Ti rotor (Beckman Coulter) in Beckman Optima L80 ...
-
bioRxiv - Molecular Biology 2020Quote: ... the lysate was incubated under rotation for 30 min at 4 °C and cleared for 10 min in an MLA-80 rotor (Beckman Coulter) at 11,500 xg and 4 °C ...
-
bioRxiv - Molecular Biology 2021Quote: ... Indexing PCR amplicons were pooled (4◻μl of each) and purified using AMPure XP beads (Beckman Coulter, California, United States) according to manufacturer’s protocol ...
-
bioRxiv - Biochemistry 2020Quote: ... cells were centrifuged at 4 ℃ for 5 minutes at 300g and suspended in HBSS and analyzed with a flow cytometer (CytoFLEX, Beckman Coulter). Mean fluorescence intensity was calculated for each group.
-
bioRxiv - Microbiology 2020Quote: ... The supernatant was ultracentrifuged at 120,000 g for 3 h at 4°C using an MLS-50 rotor (Beckman Coulter, USA) to collect 120k pellet vesicles ...
-
bioRxiv - Biochemistry 2019Quote: ... Gradients were centrifuged at 49,123 x g for 16 hours at 4°C using an SW32Ti rotor (Beckman Coulter, ref. 369694). Gradients were fractionated with a Brandel gradient fractionation system using a 1 mm UV cell detector ...
-
bioRxiv - Systems Biology 2020Quote: ... the 500xg supernatant was first spun at 10,000xg for 10 minutes at 4°C (Beckman Coulter, fixed angle rotor TLA 120.2) in 1 ml 11×34 mm polycarbonate uncapped centrifuge tubes (Beckman Coulter 343778) ...
-
bioRxiv - Microbiology 2019Quote: ... saliva EVs were pelleted by ultracentrifugation at 100,000 × g for 90 min at 4 °C (Optima™ Max-XP, Beckman Coulter). The EVs were washed in 2 ml PBS and pelleted again at 100,000 × g for 90 min and suspended in PBS ...
-
bioRxiv - Systems Biology 2020Quote: ... each resultant fraction underwent separate ultracentrifugation at 100,000xg for 40 minutes at 4°C (rotor TLA 120.2) in 1 ml 11×34 mm polycarbonate uncapped centrifuge tubes (Beckman Coulter 343778). In EV-enriched pooled fraction experiments ...
-
bioRxiv - Systems Biology 2020Quote: ... and underwent ultracentrifugation at 100,000xg for 40 minutes at 4°C (rotor MLA-55; Beckman Coulter 355603 10.4 ml capped tubes). Supernatant was discarded from each fraction ...
-
bioRxiv - Biophysics 2021Quote: The aggregation products formed in Eppendorf tubes under agitation conditions at pH 3 and pH 4 were centrifuged using an Optima MAX-XP ultracentrifuge (Beckman Coulter) in a TLA-55 rotor at 40,000 rpm at 20°C for 45 min ...
-
bioRxiv - Cell Biology 2020Quote: ... 50 µl of alkaline carbonate treated mitochondria were set aside as input (kept on ice) and 50 µl were centrifuged at 100 000g for 30 min at 4°C in TLA100 rotor (Beckman Coulter). Pellet was gently washed with ice-cold sodium carbonate buffer and resuspended in 20 µl of 1x Laemmli loading buffer ...
-
bioRxiv - Microbiology 2020Quote: ... Vesicles were obtained by centrifugation at 38,400 x g for 1 h at 4°C in an Avanti J-20XP centrifuge (Beckman Coulter, Inc). Pelleted vesicles were resuspended in 20 ml of 50 mM HEPES (pH 6.8 ...