Labshake search
Citations for Beckman :
751 - 800 of 2114 citations for 3 Hydrazino 5 methyl 4H 1 2 4 triazol 4 ylamine hydrochloride since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cancer Biology 2024Quote: ... Samples were centrifuged at 24,000 rpm under vacuum for 1.5 hrs at 4°C (Allegra X-15R Centrifuge, Beckman Coulter). The viral pellet was resuspended in 300 µL PBS ...
-
bioRxiv - Biophysics 2024Quote: ... Lysis was accomplished via douncing and the lysate was clarified via centrifugation (183,960 x g, 88 min, 4°C) in a Type 70Ti rotor (Beckman). 2 mL of IgG Sepharose 6 Fast Flow beads (Cytiva ...
-
bioRxiv - Cell Biology 2024Quote: ... and the lysate was cleared twice by centrifugation at 40,000 rcf for 20 min each at 4°C using a JA 25.50 rotor (Beckman Coulter). The cleared lysate was incubated with 2 mL Ni-NTA resin (Thermo Fisher Scientific ...
-
bioRxiv - Cell Biology 2024Quote: ... 36 mL of media per condition was subject to ultracentrifugation at 100,000 x g for 6 hours at 4 °C in a SW-32-Ti swinging bucket rotor (Beckman). The media was decanted and 500 μL PBS was added to the pellet and left to resuspend overnight at 4 °C ...
-
bioRxiv - Cancer Biology 2024Quote: ... samples were loaded based on equal total RNA onto a 10%–50% sucrose gradient and subjected to ultracentrifugation (187,813 g for 1.5 hours at 4 °C) using a SW 41 Ti rotor (Beckman Coulter). Subsequently ...
-
bioRxiv - Bioengineering 2024Quote: ... The virus was then pelleted by centrifugation at 4°C for 45 min at 25,000 rpm in a sw28 rotor (Beckman) and gently suspended in dilution buffer (150 mM NaCl ...
-
bioRxiv - Cancer Biology 2024Quote: ... which was then centrifuged at 100,000 × g for 18 hours at 4°C (344060, SW 40 Ti, Beckman Coulter) for further purification ...
-
bioRxiv - Cell Biology 2024Quote: ... All ultracentrifugation steps will be performed at 4°C using a SW41 Ti rotor (Beckman Coulter, Brea, CA, USA).
-
bioRxiv - Evolutionary Biology 2024Quote: ... Ribosomes were pelleted by centrifugation at 27,000 rpm (57,000 xg) for 16 h at 4 °C in a Ti-45 rotor (Beckman-Coulter). Ribosomes pellets were then resuspended in dissociation buffer (20 mM Tris-HCl pH 7.5 ...
-
bioRxiv - Cell Biology 2024Quote: ... Cells were harvested at day 3 post-infection by centrifuging at 2,000xg for 15 mins at 4°C using a JLA 8.1000 rotor (Beckman Coulter). Insect cell pellets were frozen in liquid nitrogen for storage or used immediately for protein purification.
-
bioRxiv - Cell Biology 2024Quote: ... Cells were harvested by centrifuging at 5,000xg for 15 mins at 4°C using a JLA 8.1000 rotor (Beckman Coulter). Bacterial cell pellets were frozen in liquid nitrogen for storage or used immediately for protein purification.
-
bioRxiv - Cell Biology 2024Quote: ... Lysates were clarified by centrifugation at 20,000 x g for 45 mins at 4°C in a JA25.50 rotor (Beckman Coulter). Clarified lysates were applied to a gravity flow column several times over 2 ml Ni-NTA resin (Sigma ...
-
bioRxiv - Microbiology 2020Quote: ... and overlaid with 6 ml of 30% and 3 ml of 5% sucrose (w/v) followed by centrifugation at 32,000 rpm in SW41 rotor (Beckman Coulter) for 20 h ...
-
bioRxiv - Neuroscience 2020Quote: ... reverse 5’-CTTA TTAGTCAGTCAGAAACAAC-3’).ThePCR amplicon was purified using RNAse-free SPRI beads (Agencourt RNAclean XP, Beckman-Coulter A63987) and then used for in vitro transcription with the HiScribe T7 ARCA mRNA Kit (with tailing ...
-
bioRxiv - Cancer Biology 2024Quote: ... The fragments were repaired the 3’and 5’overhangs using End repair mix (component of SureselectXT) and purified using Agencourt AMPure XP Beads (Beckman). The purified fragments were added with ‘A’ tail using A tailing Mix (component of SureSelectXT ...
-
bioRxiv - Biochemistry 2021Quote: ... 10 U/mL SuperASE-In and was ultracentrifuged at 100,000 × g for for 16 h at 4 °C in a SW Ti41 rotor (Beckman Coulter). After removing the supernatant ...
-
bioRxiv - Biochemistry 2021Quote: ... The lysate was clarified by ultracentrifugation at 30,000 × g 30 min at 4°C using a Ti45 rotor (Beckman Coulter) twice ...
-
bioRxiv - Biophysics 2020Quote: ... Escherichia coli BL21 cells overexpressing α-synuclein were collected by centrifugation (20 min, 4000 rpm, 4 °C) in a JLA-8.1000 rotor in a Beckman Avanti J25 centrifuge (Beckman Coulter), resuspended in lysis buffer (10 mM Tris ...
-
bioRxiv - Biophysics 2020Quote: ... The insect cells were harvested after 4 days by centrifugation at 300 g for 10 min at 4 °C in an Avanti J-26S ultracentrifuge (JLA-9.1000 rotor, Beckman Coulter). The cell pellet was resuspended in 5 ml ice-cold phosphate buffered saline (PBS ...
-
bioRxiv - Biophysics 2020Quote: ... and centrifuged at 45000 x g for 60 min at 4 °C in the Avanti J-26S ultracentrifuge (JA-30.50Ti rotor, Beckman Coulter). The cleared cell lysate was incubated in a lysis buffer-equilibrated Ni-NTA column (HisPur Ni-NTA Superflow Agarose ...
-
bioRxiv - Cell Biology 2020Quote: ... and the gradient was centrifuged for 60 min at 24,700 × g at 4 °C using a TLS-55 swinging bucket rotor (Beckman Coulter). Purified mouse POS were resuspended in DMEM/Ham’s F-12 containing 2.5% sucrose ...
-
bioRxiv - Cell Biology 2020Quote: ... lysed by sonication (UD-201 ultrasonic disrupter, Tomy Seiko), and centrifuged at 50,000 rpm (70 min, 4°C) with a 70 Ti rotor (Beckman Coulter). GST-His6-tagged LC3B-His12 and GATE-16-His12 proteins in the supernatants obtained were isolated by mixing with COSMOGEL GST-Accept beads (50% slurry ...
-
bioRxiv - Immunology 2021Quote: ... the culture medium containing the lentiviral particles was collected and ultracentrifuged at 25,000 rpm for 90 min at 4 °C using a Beckman SW28 ultracentrifuge rotor (Beckman Coulter) for the obtention of concentrated virus ...
-
bioRxiv - Microbiology 2020Quote: ... sanguinis was grown as described above and centrifuged for 10 minutes at 3,740 x g in an Allegra X-142 centrifuge at 4°C (Beckman-Coulter). The supernatant was discarded and the cells were resuspended in BHI prior to inoculation ...
-
bioRxiv - Neuroscience 2021Quote: ... PMCA products were centrifuged at 45,000 rpm for 2.5 h at 4 °C (Optima™ Max Ultracentrifuge, Beckman Coulter, USA), the supernatants discarded and the pellets resuspended in an equal volume of PBS.
-
bioRxiv - Molecular Biology 2021Quote: ... 2 mM DTT and centrifuged for 16 h at 34,000 rpm at 4°C for 16 h using an SW60 Ti rotor (Beckman Coulter). The fractions were subjected to SDS-PAGE and Coomassie blue staining.
-
bioRxiv - Molecular Biology 2021Quote: ... The samples were centrifuged at 34,000 rpm at 4°C for 16 h using an SW60 Ti rotor (Beckman Coulter). Subsequently ...
-
bioRxiv - Molecular Biology 2021Quote: ... 2 mM DTT and centrifuged for 16 h at 34,000 rpm at 4°C for 16 h using an SW60 Ti rotor (Beckman Coulter). The fractions ...
-
bioRxiv - Molecular Biology 2020Quote: ... Gradients were centrifuged at 39 000 rpm for 2.5 h at 4°C in an Optima L-100XP ultracentrifuge (Beckman– Coulter) using the SW41Ti rotor with brake ...
-
bioRxiv - Cell Biology 2020Quote: ... The insect cells were harvested after 4 days by centrifugation at 300 g for 10 min at 4 °C in an Avanti J-26S ultracentrifuge (JLA-9.1000 rotor, Beckman Coulter). The cell pellet was resuspended in 5 ml ice-cold phosphate buffered saline (PBS ...
-
bioRxiv - Cell Biology 2020Quote: ... and centrifuged at 45000 x g for 60 min at 4 °C in the Avanti J-26S ultracentrifuge (JA-30.50Ti rotor, Beckman Coulter). The cleared cell lysate was incubated in a lysis buffer-equilibrated Ni-NTA column (HisPur Ni-NTA Superflow Agarose ...
-
bioRxiv - Developmental Biology 2020Quote: ... Separation of testis cell populations was performed by centrifugal elutriation using a JE-5.0 elutriation system and a 4-ml standard elutriation chamber (Beckman Coulter). The assembly of the system followed the manufacturer’s instruction ...
-
bioRxiv - Bioengineering 2020Quote: ... the EV pellets were resuspended in 3 ml 0.32 M sucrose (diluted in PBS) solution and centrifuged again at 100,000xg for 60 minutes at 4°C (SW60 rotor, Beckman Coulter). Sucrose supernatant was removed and pellet was resuspended in 500 μl phosphate-buffered saline containing 0.01% bovine serum albumin (0.2 μm filtered ...
-
bioRxiv - Biochemistry 2020Quote: ... Protein expression was continued for 24 h before harvesting cells by centrifugation (4°C, 8000 rpm, 10 min in Beckman Coulter Avanti JXN-26 centrifuge ...
-
bioRxiv - Biochemistry 2020Quote: ... Protein expression was continued for 18 h before harvesting cells by centrifugation (4°C, 8000 rpm, 10 min in Beckman Coulter Avanti JXN-26 centrifuge ...
-
bioRxiv - Biophysics 2021Quote: Pooled seminal plasma from stallions was centrifuged for 30 min at 10,000g and 4°C (Beckman Coulter, BC - rotor SW32Ti) to pellet cell debris and larger molecular complexes ...
-
bioRxiv - Plant Biology 2020Quote: ... The sucrose gradient was centrifuged at 154,300 × g for 15 h at 4 °C using a SW 41 Ti rotor (Beckman Coulter). The LHCII proteoliposomes separated from empty liposomes were collected dropwise from the bottom of the tube and used for analysis.
-
bioRxiv - Cancer Biology 2021Quote: ... Tubes were then spun at 10,000 x g for 20 minutes at 4 °C in an ultracentrifuge (Beckman, L8-70M). The supernatant was filtered using 0.2 μM syringe filters (Millipore Sigma ...
-
bioRxiv - Cancer Biology 2021Quote: ... The pellet was washed with PBS and ultracentrifuged at 100,000 × g 1h at 4°C to obtain small vesicles (TL-100 Ultracentrifuge, Beckman Coulter). The final pellet was resuspended in PBS for subsequent experiments ...
-
bioRxiv - Biochemistry 2020Quote: ... 20% FBS containing RPMI was ultracentrifuged for 18□hours at 100,000□g at 4□°C in a 45Ti fixed angle rotor using polycarbonate tubes (both from Beckman Coulter). After ultracentrifugation ...
-
bioRxiv - Microbiology 2020Quote: ... the sample was centrifuged for 16 h at 4°C and 100,000 rcf using a type 70 Ti rotor (Beckman Coulter). The pellet was gently washed with 500 μl of storage buffer (lysis buffer C + 10% (v/v ...
-
bioRxiv - Plant Biology 2021Quote: ... The plant debris was removed by centrifuging at 16 000 g for 15 minutes at 4°C in a JA-25.50 rotor and Avanti J- 20 XP centrifuge (Beckman Coulter). The clear supernatant was then gently poured on top of 8 ml sucrose cushion (100 mM Tris·HCl (pH 8.0) ...
-
bioRxiv - Microbiology 2021Quote: ... The density gradient centrifugation was performed at 141,000 g and 4 °C for 20 h in a SW28 swing rotor (Beckman Coulter). A total of 18 fractions were collected starting from the top.
-
bioRxiv - Neuroscience 2020Quote: ... Samples were centrifuged at 15,600 rpm and 4°C using a Swi32T swinging bucket rotor and Beckman ultracentrifuge (Beckman Coulter) for 45 minutes ...
-
bioRxiv - Microbiology 2021Quote: ... Archaella were pelleted from the supernatant by ultracentrifugation (60,000 × g, 90 min, 4 °C; Beckman Optima LE-80K, rotor 70Ti), resuspended in 150 μl 0.1 M HEPES/NAOH pH 7.0 and purified for 48 h (250,000 × g ...
-
bioRxiv - Molecular Biology 2020Quote: ... The sucrose gradients were centrifuged at 200,000 x g avg at 4°C for 173 min using a SW40Ti rotor (Beckman Coulter). After the spin ...
-
bioRxiv - Microbiology 2020Quote: ... Virus was pelleted at 1847 x g for 30 min at 4°C in the plate in an Allegra centrifuge (Beckman) and the pellet was resuspended in 50 uL of loading buffer with DTT for analysis by WB with αGag ...
-
bioRxiv - Cell Biology 2020Quote: ... The cell lysate was collected in a flask on ice and ultracentrifuged at 4°C for 25 min at 50000 rpm using a Ti-70 rotor (Beckman). The protein purification was done through affinity chromatography on a Ni-column (HiTrap chelating HP column 1 ml ...
-
Micro RNAs are minor constituents of extracellular vesicles and are hardly delivered to target cellsbioRxiv - Cell Biology 2020Quote: ... FCS was diluted 1:1 with RPMI and centrifuged at 100,000 g at 4 °C in a swinging-bucket rotor (SW28 or 32, Beckman Coulter) for 18 h ...
-
bioRxiv - Microbiology 2021Quote: ... cell lysate was centrifuged 20 min at 14,000 rpm and 4°C to sediment cell debris and supernatant was transferred to microcentrifuge polypropylene tubes (Beckman Coulter) and cytoplasmic membranes were precipitated by ultracentrifugation for 45 min at 55,000 rpm and 4°C (Beckman Coulter rotor TLA 55) ...