Labshake search
Citations for Beckman :
751 - 800 of 854 citations for 3 Cyclohex 1 enyl acrylic acid methyl ester since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cell Biology 2024Quote: ... plasma samples were thawed on ice and subjected to ultracentrifugation at 100,000 g for 1 hr or 18 hr at 4 °C (TLA-55 rotor; Optima MAX-MP Tabletop Ultracentrifuge, Beckman Coulter). Pellets were washed once in 1.0 ml PBS ...
-
bioRxiv - Microbiology 2024Quote: ... The final Hcp1-VLPs particles were pelletized by ultracentrifugation at 274,000 ×g at 4°C for 1 h in a SW41 Ti rotor (Beckman Coulter, Inc). The final pellet was resuspended in PBS pH 7.4.
-
bioRxiv - Microbiology 2024Quote: Intracellular HIV-1 p24 staining was performed on fixed U1 and ACH-2 cells with KC57-FITC (Beckman Coulter, Cat#6604665). After allowing at least 30 minutes for fixation ...
-
bioRxiv - Neuroscience 2023Quote: ... The absorbance was recorded at 1 min intervals for 10 min at 340 nm at 30°C using a spectrophotometer (DU 800, Beckman Coulter). The enzymatic activity was determined as the change in absorbance/min/mg protein.
-
bioRxiv - Immunology 2023Quote: ... cells were washed with 1% FBS in PBS antibody staining buffer and stained with the following antibodies: CD64 PE-Cy7 (Cat. # B06025, Beckman Coulter); CD45 PerCP (Cat ...
-
bioRxiv - Biochemistry 2023Quote: GFP fluorescence level (FITC channel, signal amplification = 1) and cell size (FSC channel, signal amplification = 200) were measured with flow cytometer CytoFlex S (Beckman Counter) and CytExpert Software in 10000 cells (per each sample ...
-
bioRxiv - Bioengineering 2023Quote: ... The suspension was then ultracentrifuged (58,000 × g, 1 hr., 4 °C) in an Optima MAX-XP (Beckman Coulter, Indianapolis, IN, USA) to separate residual catalyst ...
-
bioRxiv - Genomics 2023Quote: PCR reaction products were cleaned and size selected using a 0.7:1 ratio of AMPure XP SPRI beads (Beckman Coulter Inc.) to sample ...
-
bioRxiv - Plant Biology 2024Quote: ... Then the reaction was started by adding 150 µL of a 1 M proline solution and the decrease in the OD600 monitored until at least 1 min of linear reaction was observed (DU-800 Spectrophotometer, Beckman Coulter). Reaction rates were calculated using the 600 nm absorbance coefficient of DCPIP (19.1 mM-1 cm-1 ...
-
bioRxiv - Biochemistry 2022Quote: ... to remove intact cells and the supernatant was centrifuged again at 25,000 RCF for 1 hour (Beckman Coulter JA-20 rotor). The pellet was resuspended in lysis buffer and sodium cholate was added to a final concentration of 1% and stirred at 4°C for 1 hour ...
-
bioRxiv - Microbiology 2023Quote: ... and permeabilized in PBS/1% BSA/0.1% saponin before staining with a FITC-conjugated anti-Cap24 (KC57-FITC, Beckman Coulter, France) for 1h at room temperature ...
-
bioRxiv - Biochemistry 2023Quote: ... to remove intact cells and the supernatant was centrifuged again at 25,000 RCF for 1 hour (Beckman Coulter JA-20 rotor). The pellet was resuspended in lysis buffer and sodium cholate was added to a final concentration of 1% and stirred at 4°C for 1 hour ...
-
bioRxiv - Microbiology 2024Quote: ... Four working concentrations were achieved through 1:2 serial dilutions using a Biomek i7 liquid handler (Beckman Coulter, ED. Fig. 1a). Precultures were grown overnight and diluted to an OD600 nm of 1 (WT ...
-
bioRxiv - Cell Biology 2024Quote: ... cells were washed with PBS at the indicated time and then stained for GPA/Band3/CD49d expression with 1:20 human BV421-anti-235a (Beckman Coulter), 1:20 human FITC-BRIC6 (IBGRL Research ...
-
bioRxiv - Molecular Biology 2024Quote: ... OD260 absorbance equal to 60 µg RNA in 200 µl polysome lysis buffer was loaded on 800 µl of 1M sucrose cushion in 1 ml thick wall polycarbonate tubes (part numbers 343778; Beckman Coulter). After centrifugation at 90,000 RPM (352,000 x g ...
-
bioRxiv - Biochemistry 2024Quote: ... Non-solubilized materials were removed by centrifuging the sample at 41,000 r.p.m for 1 h at 4 °C using rotor type 45 Ti in the OptimaTM L-100 XP Ultracentrifuge (BECKMAN COULTER). The resulting supernatant containing the solubilized LysP-GFP was incubated with Ni2+-NTA resin (Qiagen ...
-
bioRxiv - Biophysics 2024Quote: ... cycled at 2 secs on / 2 secs off) and clarified by centrifugation at 8500 RPM for 1 hour using a fixed angle JA-20 rotor (Beckman Coulter) at 4 °C ...
-
bioRxiv - Plant Biology 2024Quote: ... The pre-concentrated culture was centrifuged (10000 g, 10 min) in 1-L buckets (Avanti J-265 XP, Beckman Coulter, USA). The biomass reached a concentration of approximately 40 % (dry weight - DW ...
-
bioRxiv - Microbiology 2024Quote: ... and labeled intracellularly for the structural HIV-1 p24 protein with the anti-p24 clone KC57 antibody (30 min RT followed by 30 min 4°C, Beckman Coulter). HIV-1 RNA probing was performed using the PrimeFlow RNA Assay (ThermoFisher) ...
-
bioRxiv - Neuroscience 2024Quote: ... The supernatants were collected and subjected to high-speed centrifugation at 100,000× g for 1 h (TLS-55 rotor, OptimaTMMAX Ultracentrifuge; Beckman Coulter, USA). The supernatants (S100 ...
-
Sense codon-misassociated eRF1 elicits widespread ribosome stalling and induction of quality controlbioRxiv - Molecular Biology 2024Quote: ... The mixture was layered over 900 μl of 1 M sucrose cushion 46 and ultracentrifuged at 100,000 rpm ( 543,000 × g) at 4°C for 1 h using a TLA-110 rotor and an Optima MAX-TL Ultracentrifuge (both Beckman Coulter).
-
bioRxiv - Microbiology 2024Quote: ... the supernatant was filtered through 0.45-μm syringe filters and ultracentrifuged at 100,000 ×g for 1 h at 4 °C (MLA-50 fixed angle rotor, Beckman Coulter, Germany). The supernatant was discarded ...
-
bioRxiv - Biochemistry 2024Quote: ... Digested pellets were loaded onto a 10-50% sucrose gradient (sucrose dissolved in 1× lysis buffer) and ultracentrifuged using a SW41 Ti rotor (Beckman Coulter) at 40,000 rpm (273,620 × g ...
-
bioRxiv - Cancer Biology 2024Quote: ... Each 384 well plate was then pooled into a 1 μL reaction product and cDNA was purified using 0.8X volume of AMPure XP beads (Beckman Coulter, A63882). Each pool was analyzed for concentration and size distribution using Bioanalyzer (Agilent).
-
bioRxiv - Bioengineering 2024Quote: ... Cells were resuspended in 250 uL PBS/1% BSA after the final wash and subjected to analysis by a CytoFLEX flow cytometer (Beckman Coulter).
-
bioRxiv - Bioengineering 2024Quote: ... Cells were resuspended in 250 uL PBS/1% BSA after the final wash and subjected to analysis by a CytoFLEX flow cytometer (Beckman Coulter).
-
bioRxiv - Bioengineering 2024Quote: ... we transferred the inserts to new wells containing 1 mL of TrypLE to single-cell disperse the clusters and perform cell counts (Vi-Cell XR, Beckman Coulter). We again saved these supernatants ...
-
bioRxiv - Cell Biology 2024Quote: ... the inserts were transferred to new wells containing 1 mL of TrypLE to single-cell disperse the clusters and perform cell counts (Vi-Cell XR, Beckman Coulter). The supernatants were again saved ...
-
Inhibition of Ribosome Biogenesis in vivo Causes p53-Dependent Death and p53-Independent DysfunctionbioRxiv - Cell Biology 2024Quote: ... 1 mL of the lysates was loaded onto a 10%-50% sucrose gradient in a 14 mL polypropylene tube (Beckman Coulter). Ultracentrifugation was performed using a Beckman Optima LE-80K Ultracentrifuge Floor Centrifuge at 261,000 × g for 135 minutes at 4 °C ...
-
bioRxiv - Biophysics 2020Quote: ... The lysates were clarified by centrifugation (16,000 rpm for 1 h at 4°C, rotor JA 25.50, Beckman Coulter, Brea, California, USA). The supernatant was incubated with amylose resin for 1 h at 4°C and loaded onto a 20 ml chromatography column (Bio-Rad ...
-
bioRxiv - Biophysics 2020Quote: ... Very small amounts of fibrillar species formed during this time were removed by ultracentrifugation for 1 h at 90000 rpm (Optima TLX Ultracentrifuge, Beckman Coulter, TLA-120.2 Beckman rotor, 288000 g). The excess monomeric protein and some small oligomers were then removed by multiple filtration steps using 100-kDa cut-off membranes ...
-
bioRxiv - Genetics 2021Quote: ... A final DNase treatment was performed in 50 μL total volume using 1 μL of Turbo DNase with addition of the buffer incubated for 60 min at 37 °C followed by inactivation with 1 μL of 10% SDS and purification using RNA clean SPRI beads (Beckman Coulter, A63987).
-
bioRxiv - Systems Biology 2020Quote: ... Next the cultures were diluted 1:40 with 0.5M NaCl and immediately measured in Multisizer™4 COULTER COUNTER® (Beckman Coulter) (Coulter ...
-
bioRxiv - Molecular Biology 2021Quote: ... Resulting libraries were pooled and treated with AMPure XP magnetic beads at a ratio of 0.8:1 beads:sample volume to purify DNA (Beckman Coulter, Brea, CA, USA). Library yield and quality was determined by TapeStation electrophoresis with HSD1000 ScreenTapes (Agilent Technologies).
-
bioRxiv - Biochemistry 2020Quote: ... to a final volume of 1 ml and then further centrifuged (120000 g, 4°C, 2 h) in a TLA-120.2 rotor (Beckman Coulter, Brea, CA). Pellets were washed twice with 4°C cold PBS and centrifuged (120000 g ...
-
bioRxiv - Biophysics 2020Quote: ... The lysate was then centrifuged at 4° C in the SW32Ti rotor with a speed of 30,000 rpm for 1 h to pellet the membrane fraction using an Optima L-90K Ultracentrifuge (Beckman Instruments, Brea, CA). The pellet was resuspended in HND buffer and bulk membrane proteins were extracted by adding 2% ANAPOE-X-100 (Anatrace ...
-
Hydrogen sulfide blocks HIV rebound by maintaining mitochondrial bioenergetics and redox homeostasisbioRxiv - Microbiology 2021Quote: ... Permeabilized cells were then incubated with 50 μl of 1:100 dilution of phycoerythrin (PE)-conjugated mouse anti-p24 monoclonal antibody (KC57-RD1; Beckman Coulter, Inc.) for 30 min at room temperature ...
-
Micro RNAs are minor constituents of extracellular vesicles and are hardly delivered to target cellsbioRxiv - Cell Biology 2020Quote: ... Cat no UZ-PA-38.5-1) at 100,000 g at 4 °C for 2 h in a swinging-bucket rotor (Beckman Coulter; SW28 or SW32).
-
bioRxiv - Cell Biology 2020Quote: ... anti-CD105 and anti-HLA-ABC antibodies (suppl. Table 1) and analysed by flow cytometry (Cytoflex; Software Cytexpert 2.3, Beckman-Coulter, Krefeld, Germany). Upon passage 3 ...
-
bioRxiv - Plant Biology 2020Quote: ... Double size selection was carried out by adding 50 μL of a 1:4 (0.5X) mixture of AMPure XP Beads (Beckman Coulter, Brea, USA) to PEG buffer (20% PEG w/v ...
-
bioRxiv - Plant Biology 2020Quote: ... Soil pH and EC were 8.3 and 12 dS m−1 that were measured by a pH meter (Beckman 45 Modal, US) and EC meter (VWR Conductivity Meter DIG2052 ...
-
bioRxiv - Microbiology 2020Quote: ... Membrane-containing fractions were collected in 1 mL after ultracentrifugation at 35,000 rpm on an SW-40 rotor (Beckman, Brea, CA USA) for 6 hours at 4°C and stored at -80°C prior to analysis.
-
bioRxiv - Evolutionary Biology 2021Quote: ... with NEBNext Multiplex Oligos for Illumina® (Dual Index Primers Set 1) and AMPure XP magnetic beads (Beckman Coulter, Brea, CA, USA). DNA content and quality of indexed libraries were examined with a Qubit 4.0 using the high-sensitivity kit (ThermoFisher Scientific ...
-
bioRxiv - Microbiology 2023Quote: ... Cell pellets were permeabilized for intracellular staining via resuspension in 0.5% Triton X-100 in PBS for 10 min and were subsequently resuspended in a 1:500 dilution of anti-p24-FITC KC57 antibody (Beckman Coulter #6604665) in 1% BSA in PBS for 1 h at room temperature in the dark ...
-
bioRxiv - Neuroscience 2022Quote: ... The loaded gradient was ultracentrifuged at 69,150 x g for 1 h at 4 °C (SW 41 Ti Swinging-Bucket Rotor, Beckman Coulter, Cat. #331362) and the synaptosome fraction was harvested from the interface between the two sucrose layers ...
-
bioRxiv - Evolutionary Biology 2022Quote: ... and libraries were purified and size selected using Ampure XP Beads at a 1.8:1 bead volume:library volume (Beckman Coulter, Brea, CA, USA). Library quality and transposition efficiency was accessed using a Fragment Analyzer and PROSize 2.0 (Agilent ...
-
bioRxiv - Physiology 2023Quote: ... via centrifugation in a SW41 rotor at 42,000 g at 4 °C for 1 hour in a Beckman Coulter Optima L-100 XP ultracentrifuge using 14 × 89 mm Ultra-Clear Centrifuge Tubes (Beckman Instruments Inc.). Mitochondria were harvested at the interphase between 19 and 40% Percoll ...
-
bioRxiv - Plant Biology 2023Quote: ... DNA extracts were purified using a bead clean up method with a 2:1 ratio of Ampure XP beads (Beckman Coulter, USA) to DNA elution ...
-
bioRxiv - Cancer Biology 2024Quote: ... The cells mixed with polybrene and lentivirus were then plated in 1 mL aliquots onto 12 well plates and centrifuged at 2000 rpm (931 x g) [Allegra® X-15R Centrifuge (Beckman Coulter), rotor SX4750A] for 2 hours at 30°C ...
-
bioRxiv - Microbiology 2022Quote: ... Cells were permeabilized in 0.5% Triton-X for 10 min and stained with 1:300 KC57-FITC (Beckman Coulter 6604665; RRID: AB_1575987) or 1:300 KC57-RD1 (numbers) ...