bioRxiv - Microbiology 2023Quote: ... The tube was centrifuged for 3 hours at 150’000 x g (4°C) using a SW 32.1 Ti swinging bucket (369651, Beckman Coulter). Finally ...
-
bioRxiv - Plant Biology 2023Quote: ... The tubes were then centrifuged at 100,000 x g for 1 h at 4 ⁰C (TLA 55 rotor, Beckman Coulter ...
-
bioRxiv - Biochemistry 2023Quote: ... The lysate was clarified by centrifugation (183,960 x g, 88 min, 4°C) in a Type 70Ti rotor (Beckman). The supernatant was mixed with 2 mL of IgG Sepharose 6 Fast Flow beads (Cytiva ...
-
bioRxiv - Biochemistry 2023Quote: ... The lysate was clarified via centrifugation (66,000 x g, 30 min, 4°C) in a Type 70 Ti rotor (Beckman). The supernatant was mixed with 1.5 mL of anti-FLAG M2 affinity gel (Sigma-Aldrich ...
-
bioRxiv - Immunology 2022Quote: ... then samples were centrifuged at 2,700 RPM for 10 minutes at 4°C in a tabletop centrifuge (Beckman Coulter). The supernatant (serum ...
-
bioRxiv - Cell Biology 2022Quote: ... The supernatant was centrifuged at 200,000 x g for 2.5 h (high g) at 4°C in a TLA-100.3 fixed angle rotor (k-factor 14) (Beckman Coulter) and the pellet was resuspended in 25 ∝l lysis buffer ...
-
bioRxiv - Cell Biology 2023Quote: ... Gradients were spun at 45,000 RPM for 16 hours at 4°C in SW55Ti rotor using an ultracentrifuge (Beckman). After centrifugation ...
-
Comparative membrane proteomics reveals diverse cell regulators concentrated at the nuclear envelopebioRxiv - Cell Biology 2023Quote: ... The gradients then were centrifuged at 35,000 rpm (210,000g) for 1 h at 4°C with no brake in an SW41Ti rotor (Beckman Coulter). Two samples were collected from the nucleus gradient ...
-
bioRxiv - Biochemistry 2023Quote: ... The lysate was then clarified (using a JA 25.50 Beckman rotor at 40000x g for 30 min, 4°C) and the soluble fraction was incubated with 2 ml of Glutathione Sepharose 4B resin for 2h at 4°C under constant agitation ...
-
bioRxiv - Cancer Biology 2023Quote: ... 100 μg/mL cycloheximide if reaction contained cycloheximide) for 3.5 hrs at 240,000 g at 4 °C using a SW41 rotor (Beckman Coulter). Gradients were fractionated using Teledyne Isco Tris Peristaltic Pump and fractions were collected and pooled according to the UV trace ...
-
bioRxiv - Biochemistry 2023Quote: ... Density gradient centrifugation was done at 50,000 rpm for two hours at 4 °C using a 70.1 Ti rotor (Beckman Coulter). Post centrifugation ...
-
bioRxiv - Neuroscience 2023Quote: ... the supernatant was collected and applied for further centrifugation at 40,000 rpm for 1 h at 4°C (45 Ti fixed-angle rotor, Beckman) to pellet the membranes ...
-
bioRxiv - Immunology 2023Quote: ... and then centrifuged at 260,800 x g for 2.5 h at 4°C in an Optima L-100XP ultracentrifuge (Beckman–Coulter) using the SW41Ti rotor with brake ...
-
bioRxiv - Biochemistry 2023Quote: ... binding reactions were centrifuged at 50,000 RPM for 30 min at 25 °C in a TLA-100 rotor (Beckman). Following centrifugation ...
-
bioRxiv - Microbiology 2023Quote: ... 500 μ g of the lysate was loaded on the top of 15–50% sucrose gradient containing 100μ g/ml cycloheximide and the gradients were centrifuged at 36,000 rpm for 2 h at 4°C in SW41 rotor (Beckman). Density Gradient Fractionation System (ISCO ...
-
bioRxiv - Cell Biology 2022Quote: ... The supernatant was centrifuged at 200,000 x g for 2.5 h (high g) at 4°C in a TLA-100.3 fixed angle rotor (k-factor 14) (Beckman Coulter) and Red-C12 fluorescence of the starting material ...
-
bioRxiv - Cell Biology 2023Quote: ... After cell debris and undisrupted cells were removed by centrifugation (45,000 rpm, 30 min, 4°C, 70Ti rotor; Beckman), supernatant was applied to an open column with Ni-IMAC resin (BIO-RAD) ...
-
bioRxiv - Neuroscience 2023Quote: ... the liposomes were isolated by centrifugation for 3 h 40 mins at 55,000 rpm at 4°C in a SW 60 rotor (SW 60 Ti, Beckman). 20 µl were harvested from the top of the gradient and mixed with 8 µl of 4x Laemmli buffer (final 62.5 mM Tris-HCl ...
-
bioRxiv - Plant Biology 2023Quote: ... The cel lysates were clarified by high-speed centrifugation at 50,000g for 60 min at 4°C (Avanti J-26 XP centrifuge with JA-25.50 rotor; Beckman Coulter), followed by a 0.45-mm filtration (Millex-HP ...
-
bioRxiv - Molecular Biology 2024Quote: ... Virus was then purified by centrifugation through a 20% sucrose cushion at 25,000 rpm for 2.5 hours at 4 °C in a Sw32Ti rotor (Beckman Coulter). Virus pellets were resuspended in PBS and virus genomic RNA copy number was quantified by RTqPCR as described above ...
-
bioRxiv - Neuroscience 2024Quote: ... The total 200mL of supernatant was centrifuged at 28,000rpm for 2h at 40 °C in a 45Ti rotor (Beckman), which can sustain faster speeds ...
-
Ribonuclease Inhibitor and Angiogenin collaboratively regulate cell-type-specific global translationbioRxiv - Biochemistry 2024Quote: ... and were centrifuged at 39,000 rpm for 2.45 hours at 4°C using Optima XPN-80 Ultracentrifuge (Beckman Coulter). Following centrifugation ...
-
bioRxiv - Molecular Biology 2023Quote: ... Small extracellular vesicles were pelleted at 100,000 X g for 1,5 h at 4°C by using Ti-45 rotor (Beckman Coulter) and 70 ml polycarbonate bottles (Beckman Coulter ...
-
bioRxiv - Molecular Biology 2023Quote: ... Pellets were pooled in 1 ml PBS and centrifuged at 100,000 X g for 1,5 h at 4°C in 1,5 ml tubes in a Ti-45 rotor (Beckman Coulter) using adapters (#11004 ...
-
bioRxiv - Cancer Biology 2023Quote: ... the obtained supernatant was filtered through a 0.22 μm filter before ultracentrifugation at 150,000 g for 2 h at 4 °C (Beckman Coulter). The nsEV-containing pellet was resuspended in phosphate buffer saline (PBS).
-
bioRxiv - Biochemistry 2023Quote: ... SV experiments were conducted in charcoal-filled Epon centerpieces with a 12-mm optical path length at 20 °C and at rotor speeds ranging from 38,000 to 48,000 rpm (An-50 Ti rotor, Beckman Coulter). All sedimentation profiles were recorded with either absorption optics at 280 nm or interference optics ...
-
bioRxiv - Microbiology 2023Quote: ... The samples were centrifugated at 70000 rpm for 2 h at 4°C in an Optima TLX Ultracentrifuge (Beckman Coulter ...
-
bioRxiv - Neuroscience 2023Quote: ... NP-40 prepared in DPBS] and then ultracentrifuged at 100,000x g for 1 h at 4 °C using a TLA-55 rotor (Beckman). The supernatant was removed ...
-
bioRxiv - Cell Biology 2023Quote: ... Equilibrated tubes were ultra-centrifuged at 100,000xg for 1h at 4°C using a swinging-bucket rotor (SW 32Ti, Beckman Coulter ...
-
bioRxiv - Cell Biology 2023Quote: ... of proteins were applied on the top of a 16 ml 10-30% continuous sucrose density gradient and centrifuged at 74,400 g for 15 h at 4 °C (SW 32.1 Ti; Beckman Coulter). 24 equal volume fractions were collected ...
-
bioRxiv - Biochemistry 2023Quote: ... at 18000 PSI and cell debris were separated by centrifugation (4 °C, 30 min, 75,600 ×g, JA25.50 rotor Beckman Coulter). The supernatant was loaded on an affinity chromatography column (GE Healthcare ...
-
bioRxiv - Cell Biology 2023Quote: ... Solutions of 15% and 23% Optiprep were layered on top or below the sample and centrifuged at 4°C for 16 h at 120,000g in a SW 28 Ti swinging bucket rotor (Beckman).
-
bioRxiv - Developmental Biology 2023Quote: ... the supernatant was centrifuged in a TLA100.4 fixed angle rotor at 100000 g for 1h at 37°C in an Optima TL ultracentrifuge (Beckman). The supernatant containing globular actin was collected ...
-
bioRxiv - Genetics 2023Quote: ... Fifteen A260 units of WCEs were layered on a pre-chilled 10-50% sucrose gradient and centrifuged at 40,000 rpm for 2 h at 4°C in a SW41Ti rotor (Beckman). Gradient fractions were continuously scanned at A260 using the BioComp Gradient Station and polysome to monosome (P/M ...
-
bioRxiv - Molecular Biology 2024Quote: ... for ultracentrifugation at 100,000 × g for 1 hour at 4°C (JXN-30 centrifuge, JA-30.50 Ti Rotor, Beckman Coulter). The pellet was washed with PBS and centrifuged again at 100,000 × g for 1 hour at 4°C to remove soluble contaminant ...
-
bioRxiv - Neuroscience 2024Quote: ... by centrifugation at 5,000 x g at 4°C for 30 minutes in a fixed angle rotor (Beckman Coulter). The qEV column washed with 1x PBS was then loaded with 500 µL of concentrated supernatant followed by 2.5 mL PBS to collect 3 mL void volume ...
-
bioRxiv - Neuroscience 2024Quote: ... and PBS was added to reach a 4.5 mL tube filling and centrifuged at 120,000xg for 100 min at 4°C in the L-60 Optima Ultracentrifuge (Beckman Coulter ...
-
bioRxiv - Neuroscience 2024Quote: ... Ultracentrifugation was performed for 2.5 h at 18 °C at 350,000 × g in a type 70 Ti rotor (Beckman Coulter). The interface between the 60 and 40% gradient was extracted along with the 40% layer ...
-
bioRxiv - Biochemistry 2023Quote: ... lysates were centrifuged at 60,000 x g (4 °C) for 45 min (Beckman Avanti JXN-26 (rotor: JA 25.5)) and immediately supplemented with 10 mL pre-washed Ni2+-NTA agarose (QIAGEN ...
-
bioRxiv - Biophysics 2024Quote: ... Each seed mix was clarified using an ultra-centrifuge (Beckman Optima MAX-XP, 90,000 RPM, 4°C, 5 min) then snap-frozen in small aliquots and stored at -80°C ...
-
bioRxiv - Cancer Biology 2024Quote: ... 100 μg/mL cycloheximide) for 2 h at 40,000 g at 4 °C using an SW41 rotor (Beckman Coulter). Gradients were fractionated using Teledyne Isco Tris Peristaltic Pump and fractions were collected and pooled according to the UV trace ...
-
bioRxiv - Cell Biology 2024Quote: ... samples were ultracentrifuged at 160,000 xg for 2 h at 4 °C in ultracentrifuge tubes (Beckman Coulter Cat #328874). The resulting pellet contained the insoluble AMB-1 cell fraction and the supernatant contained the soluble fraction ...
-
bioRxiv - Cell Biology 2023Quote: ... Samples were spun at 200,000 × g at 4°C for 4 h in an MLS-50 rotor (Beckman Coulter), and 60 µL of top layer was collected ...
-
bioRxiv - Cell Biology 2024Quote: ... The supernatant was then subjected to ultracentrifugation at 100,000 x g for 2 h at 4 °C to sediment small EVs (Optima L-80K ultracentrifuge, Beckman Coulter ...
-
bioRxiv - Molecular Biology 2024Quote: ... and 1 M sucrose) at 100,000 rpm (543,000 × g) and 4°C for 1 h with a TLA110 rotor (Beckman Coulter) and an Optima MAX-TL Ultracentrifuge (Beckman Coulter) ...
-
bioRxiv - Immunology 2023Quote: ... FITC-conjugated anti Vδ2 and PE-conjugated anti CD69 mAbs were purchased from Beckman Coulter ...
-
Combining LSD1 and JAK-STAT inhibition targets Down syndrome-associated myeloid leukemia at its corebioRxiv - Cancer Biology 2022Quote: ... anti-CD11b-PC7 (Beckman Coulter) and anti-CD86-Alexa Fluor® 700 (BD Biosciences ...
-
bioRxiv - Immunology 2022Quote: ... anti-Gag KC57 (Beckman Coulter) by intracellular staining and labelled for HIV gag mRNA using the PrimeFlow RNA assay (ThermoFisher ...
-
bioRxiv - Immunology 2020Quote: ... anti-CD56-APC (Beckman Coulter), anti-CD19-PB (Dako) ...
-
bioRxiv - Microbiology 2020Quote: ... anti-CD159a-PC7 (Beckman Coulter) prepared in brilliant stain buffer ...