Labshake search
Citations for Beckman :
651 - 669 of 669 citations for 5 Methyl 3 phenylmethylene 2 3H furanone since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Genomics 2020Quote: ... were layered onto a 1.8M sucrose cushion and ultra-centrifuged at 24,400 rpm at 4°C for 2 hours using a SW28 swinging bucket rotor (Beckman Coulter Optimal centrifuge #L90K). The nuclear pellet was re-suspended in 2% BSA in 1X PBS ...
-
bioRxiv - Microbiology 2020Quote: ... EMVs were obtained by ultracentrifugation from 4 mL of filtrate at 100,000 × g (average centrifugal force) and 4°C for 2 h with an OptimaX centrifuge (Beckman Coulter, Brea, CA, USA). The pellets were resuspended in 400 μL of Dulbecco’s phosphate-buffered saline (DPBS ...
-
bioRxiv - Neuroscience 2022Quote: ... The tubes were sealed and centrifuged at 50,000 rpm at 4°C for 2 h in an OptimaTM L-90K ultracentrifuge using the 70.1Ti rotor (Beckman Coulter, Brea, CA, USA). After the centrifugation ...
-
bioRxiv - Cell Biology 2020Quote: ... 3 μM or 10 μM from a 2 mM or 10 mM stock solution using a Biomek FX with 384-well head (Beckman Coulter, Indianapolis, IN). The DMSO concentration was kept below or at 0.5% v/v ...
-
bioRxiv - Physiology 2022Quote: ... the library preparation step followed the CEL-Seq 2 protocol85: the RT product was digested by ExoI and HinFI and purified using AMpure XP beads (Beckman Coulter™, USA). Then ...
-
bioRxiv - Microbiology 2023Quote: ... then the colonies were diluted and inoculated into the Neg MIC EN-2J panel containing β-lactams listed in Table 2 and incubated in MicroScan Walkway40 Plus (Beckman Coulter Inc.). Breakpoint criteria for susceptible (S) ...
-
bioRxiv - Neuroscience 2020Quote: ... for further depletion of cell debris and spun at 10,000 × g for 30 min at 4°C (AH-650 rotor, Beckman Ultra-Clear Tube with 5 ml capacity). The pellet was resuspended in 100 μl PBS and considered to be the “10K pellet” (10K or 10K fraction) ...
-
bioRxiv - Molecular Biology 2020Quote: ... bound antibodies were visualized using 100 µL of a 1:100 dilution of goat F(ab’)2 anti-human IgG coupled to phycoerythrin (Beckman Coulter, Brea, CA, USA) at 4°C for 30 min ...
-
bioRxiv - Biochemistry 2020Quote: Sedimentation velocity experiments were performed using a ProteomeLab XL-1 analytical ultracentrifuge with the use of an AN60-Ti rotor and Epon-2 channel centerpieces (Beckman Coulter, Brea, CA, USA). Protein samples were diluted with SANS buffer to concentrations yielding an absorbance of 0.5 at 280 nm as measured with an 8454 UV–Vis spectrophotometer (Agilent ...
-
bioRxiv - Microbiology 2022Quote: ... The success of the amplifications was checked in a 2% agarose gel and PCR products were subsequently purified using Agencourt AMPure XP magnetic beads kit (Beckman Coulter, Brea, CA, USA), quantified with the QuantiFluor™ dsDNA System (Promega ...
-
bioRxiv - Molecular Biology 2019Quote: ... The concentrated urine sample was resuspended in 3.2 ml of a 50% iodixanol solution and layered on the bottom of a 17 ml Thinwall Polypropylene Tube (Beckman Coulter, Fullerton, California, USA). A discontinuous DG was prepared by additional layering of 4 ml of 20% ...
-
bioRxiv - Neuroscience 2019Quote: ... and 1□mM DTT) before a centrifugation process of 2 h 20 min at 30,000□× g (Beckman J-25 centrifuge with a J13.1 rotor). The supernatant was carefully aspirated and the extracted nuclei in a form of a pellet were resuspended in a nuclear storage buffer (15% sucrose ...
-
bioRxiv - Biochemistry 2019Quote: ... and 5 mM MgCl2 at pD 7.5 corresponding to a pH reading of 7.1) at 25°C as follows: spin column at 2000 rpm for 2 min in a tabletop centrifuge (Beckman Coulter Allegra R Tabletop Centrifuge), discard the flow-through ...
-
bioRxiv - Microbiology 2020Quote: ... and layered on top of a two-step sucrose gradient (20%/50% w/v in HNE) and centrifuged for 2 h at 154 000 x g at 4 °C in a SW41 rotor (Beckman Coulter, Woerden, the Netherlands) to clear from cell debris ...
-
bioRxiv - Microbiology 2023Quote: The amplicons obtained with each of the strategies (using pools 1 and 2) were pooled in each group and purified with one volume of AMPure XP beads (Beckman Coulter, Brea, CA, USA). The beads were washed with 80% ethanol ...
-
bioRxiv - Biochemistry 2023Quote: ... cells were treated with the drugs (20 µM to a suspension at 500,000 cells/mL in PBS containing 2 % FBS at 37°C) and directly analyzed by flow cytometry (Gallios, Beckman-Coulter, 405/488 nm laser) over 2 h ...
-
bioRxiv - Cancer Biology 2020Quote: ... Filtered media containing lentiviral particles were centrifuged at 24000rpm at 20°C for 2 hrs in 90Ti rotor in ultra-centrifuge (Beckman Coulter Optima TM L-100K). Viral particle pellet was obtained after discarding supernatant post centrifugation and suspended in 100 μl OptiMEM media for overnight at 4°C.The collected lentivirus suspension was used for transfection or stored for later use at −80°C ...
-
bioRxiv - Biochemistry 2019Quote: ... Resuspended cells were lysed by French Press (8,000 psi, 4°C, 2 passages) and lysates were centrifuged (Beckman 60Ti rotor, 30 min, 50,000 rpm, 4°C). Pellets were resuspended in 100 ml of buffer B (PBS [140 mM NaCl ...
-
bioRxiv - Microbiology 2023Quote: ... another 2 mL of staining bacterial samples was analyzed with a flow cytometry to check cell viability (Beckman CytoFLEX FCM, USA, Channel FL2-A: PE-A).