bioRxiv - Cell Biology 2022Quote: ... The supernatant was centrifuged at 300,000×g at 4°C for 3 h in a TLA-110 fixed angle rotor (k-factor 13) (Beckman Coulter). The pellet was resuspended in 10 µL PBS of which 3 µL was adsorbed onto glow-discharged 2 nm carbon layer coated Quantifoil R1.2/1.3 400 mesh gold grids ...
-
bioRxiv - Cell Biology 2022Quote: ... 4–40% sucrose gradient prepared in lysis buffer and centrifuged at 150,000 × g for 4 or 16 h at 4°C in a MLS-50 rotor (Beckman Coulter). Thereafter ...
-
bioRxiv - Cell Biology 2023Quote: ... The iodixanol density gradients were centrifuged at 100,000 x g at 4◦C for 18 hours in SW41Ti rotor (Beckman Coulter). Ten fractions (F1 ...
-
bioRxiv - Cell Biology 2023Quote: ... Each fraction was subjected to a washing step in ice-cold PBS at 100,000 × g at 4°C for 2 h using a SW28Ti rotor (Beckman Coulter). The pelleted EVs were resuspended in ice-cold PBS ...
-
bioRxiv - Molecular Biology 2023Quote: ... then pelleted at 4°C and 4,300 x g for 30 min in an Allegra X-14R centrifuge (Beckman Coulter) equipped with a swinging bucket SX4750 rotor ...
-
bioRxiv - Microbiology 2023Quote: ... Each tube was centrifuged for 3 hours at 150’000 x g (4°C) using an Optima XPN-80 ultracentrifuge (Beckman Coulter) equipped with a SW 32 Ti swinging bucket (369650 ...
-
bioRxiv - Cell Biology 2023Quote: ... loaded onto a discontinuous 0.75/1.0/2.33 M sucrose gradient and spin at 242,000 g for 1 h at 4 °C in a SW32Ti rotor (Beckman & Coutler). Growth cone fractions were collected at the interface load/0.75 M sucrose and non-growth cone fractions collected between 0.75/1.0 M sucrose and then analyzed by Western Blot.
-
bioRxiv - Cell Biology 2023Quote: ... 5 mM Mg(OAc)2) and centrifuged for 20 min at 100,000 x g in a 70Ti rotor (Beckman Coulter). The resulting membrane pellet was resuspended in 1 ml rough microsome (RM ...
-
bioRxiv - Cancer Biology 2023Quote: ... EV-depleted FBS was made by ultra-centrifuging the FBS at 100,000 x g overnight (18h) in a Ti 45 rotor (Beckman Coulter).
-
bioRxiv - Cell Biology 2023Quote: ... The obtained supernatant was layered onto 30 w/v% sucrose solution in ultracentrifugation tubes and subjected to ultracentrifugation at 100,000 × g for 3 h at 4°C using SW32Ti rotor (Beckman courter). The collected sucrose solutions were mixed with PBS and washed by ultracentrifugation at 100,000 × g for 1 h ...
-
bioRxiv - Cancer Biology 2023Quote: ... Large EVs were collected by centrifugation at 10,000 x g for 30 minutes in a Ti 45 rotor (Beckman Coulter). Small EVs were collected by a modified cushion-density gradient protocol (Li et al. ...
-
bioRxiv - Systems Biology 2023Quote: ... The urine was centrifuged at 20,000 x g for 30 minutes at 4°C (k-factor 1,790) in an Optima XPN-80 ultracentrifuge (Beckman Coulter) equipped with a SW32 Ti swinging bucket rotor (Rmin 67 ...
-
bioRxiv - Plant Biology 2023Quote: ... It was then centrifuged again at 100,000 x g for 1 h at 4 ⁰C (TLA 55 rotor, Beckman Coulter; OptimaTM Max ultracentrifuge, Beckman Coulter). The final pellet containing the purified EV fraction was resuspended in 50 µl of 20 mM Tris-HCl pH 6.0 ...
-
bioRxiv - Plant Biology 2023Quote: ... at 10,000 x g for 1 h at 4 ⁰C (JA-17 rotor, Beckman Coulter; Avanti J-20TM centrifuge, Beckman Coulter). The supernatant from this step was decanted into the new tubes and centrifuged at 39,800 x g for 2 h at 4 ⁰C (JA-17 rotor ...
-
bioRxiv - Cell Biology 2023Quote: ... The supernatant was then overlaid onto a 2 ml 60% iodixanol cushion and spun at 100,000 x g (SW32 rotor, Beckman Coulter) for 18h ...
-
bioRxiv - Neuroscience 2023Quote: ... This supernatant was next subjected to ultracentrifugation at 120,000 x g for 2 h at 4LJ in a SW 41 Ti Rotor Swinging-Bucket rotor (Beckman Coulter), and the pellets collected as small factors like exosome ...
-
bioRxiv - Neuroscience 2023Quote: ... The lysate was separated into soluble and insoluble fractions by ultracentrifugation at 100,000 x g for 1 h using Optima L-XP (Beckman Coulter). The soluble fraction was filtered using a bottle-top 0.22-µm filter (Corning) ...
-
Dopaminoceptive D1 and D2 neurons in ventral hippocampus arbitrate approach and avoidance in anxietybioRxiv - Neuroscience 2023Quote: ... 10 mM Tris-HCl) and centrifugated at 107,000 g for 1 hour at 4°C in a SW41Ti Swinging-Bucket Rotor (Beckman Coulter). Supernatant was discarded and nuclei pellets were re-suspended in 800 µL of PBS supplemented with 0.5% bovine serum albumin (BSA) ...
-
bioRxiv - Plant Biology 2023Quote: ... Approximately 250 µl of crude EV sample resuspended in 20 mM Tris-HCl pH 6.0 was slowly dispensed on top of the column and centrifuged at 100,000 x g for 17 h at 4 ⁰C (SW 41 Ti rotor, Beckman Coulter; OptimaTM L-90K, Beckman Coulter). After the ultracentrifugation ...
-
bioRxiv - Plant Biology 2023Quote: ... The resulting solution was then centrifuged again at 39,800 x g for 2 h at 4 ⁰C (JA-17 rotor, Avanti J-20TM centrifuge, Beckman Coulter). The supernatant was decanted ...
-
bioRxiv - Plant Biology 2023Quote: ... The supernatant from this step was decanted into the new tubes and centrifuged at 39,800 x g for 2 h at 4 ⁰C (JA-17 rotor, Beckman Coulter; Avanti J-20TM centrifuge, Beckman Coulter). The supernatant was then decanted and discarded ...
-
bioRxiv - Plant Biology 2023Quote: ... The tubes were then centrifuged at 100,000 x g for 1 h at 4 ⁰C (TLA 55 rotor, Beckman Coulter; OptimaTM Max ultracentrifuge, Beckman Coulter). The pellets from the tubes were pooled together in 500 µl of 20 mM Tris-HCl pH 6.0 buffer and the volume was brought up to 1,500 µl using 20 mM Tris-HCl ...
-
bioRxiv - Cell Biology 2023Quote: ... The density adjusted FBS was subjected to ultracentrifugation for 25 h at 310,500 x g at 10°C in a 70Ti rotor (Beckman Coulter) before dialysis ...
-
bioRxiv - Cell Biology 2023Quote: ... the post-nuclear supernatant was centrifuged for 30 min at 100,000 x g at 4°C using a S120AT2 rotor (Beckman Coulter). The resulting pellet containing the membranes was resuspended in SDS sample buffer (see below).
-
bioRxiv - Cell Biology 2022Quote: ... The supernatant was then transferred to polycarbonate tubes and centrifuged at 100,000 × g and 4°C for 1 h in a XL-90 ultracentrifuge (Beckman Coulter) ...
-
bioRxiv - Cell Biology 2022Quote: ... This spin was repeated and the resulting supernatant was then centrifuged for 1 h at 75,000 g at 4°C (TLA-100.3 rotor or Type60 Ti rotor; Beckman Coulter, USA). The supernatant was aspirated and the membrane pellet gently resuspended in microsome buffer (10 mM HEPES/KOH pH 7.5. ...
-
bioRxiv - Biochemistry 2023Quote: ... made in TEMB buffer) and ultracentrifuged at 105,000 x g for 35 min (SW 32 Ti Swinging-bucket, Beckman Coulter). Gradients were fractionated ...
-
bioRxiv - Neuroscience 2023Quote: ... Fraction LP2 was obtained after centrifugation of fraction LS1 for 2 h at 165,000 g in a SW40 Ti rotor (Beckman, US). Corresponding supernatant was collected as Fraction LS2 ...
-
bioRxiv - Neuroscience 2023Quote: ... and centrifuged at 100,000 × g for 1 h at 4 °C using a TLA-55 rotor in an Optima TLX Ultracentrifuge (Beckman Coulter). The first supernatant ...
-
bioRxiv - Genomics 2023Quote: ... the supernatant was cleared by two rounds of centrifugation at 20,000 ×g (10 min, 4 °C, JA-20 rotor, Avanti J-26 XP, Beckman Coulter) followed by centrifugation at 31,900 ×g (10 min ...
-
bioRxiv - Genomics 2023Quote: ... Precipitated ribosomes were pelleted at 20,000 ×g (10 min, 4 °C, JA-20 rotor, Avanti J-26 XP, Beckman Coulter). To remove residual supernatant the pellet was re-centrifuged for 5 min at 20,000 ×g ...
-
bioRxiv - Genomics 2023Quote: ... The suspension was incubated on ice for 5 min and centrifuged at 20,000 ×g (10 min, 4 °C, JA-20 rotor, Avanti J-26 XP, Beckman Coulter). The pellet was re-centrifuged for 5 min and both supernatants were combined into a new tube ...
-
bioRxiv - Cancer Biology 2023Quote: ... clarified by centrifugation at 20,000 rpm (48,385 x g) for 30 min in a JA25.50 rotor at 4 °C (Beckman AvantiTM J-25), filtered through a 0.8/0.2 AcroPak Filter Unit (Pall) ...
-
bioRxiv - Biophysics 2023Quote: ... Reactions were centrifuged at 400,000 g at 20 °C for 15 min in polycarbonate centrifuge tubes (Beckman Coulter Inc. USA). The pellets were resuspended in 40 μl reaction buffer ...
-
bioRxiv - Genomics 2023Quote: ... The ribosomes were further purified by centrifugation at 59,727 ×g (15 hours, 4 °C, SW 32.1 Ti rotor, Optima™ L-100 XP, Beckman Coulter) in a linear (15 – 30 % ...
-
bioRxiv - Cell Biology 2023Quote: ... then incubated for 1 hr at RT before centrifugation at 100,000 x g (23°C) in a TLA100 rotor (Beckman-Coulter). The top 50% of the supernatant was removed ...
-
bioRxiv - Plant Biology 2023Quote: ... The cAW was collected by spinning at 700 x g for 20 min at 4 ⁰C (JA-14 rotor, Beckman Coulter ...
-
bioRxiv - Biochemistry 2023Quote: ... The gradient was centrifuged for 2.30 hours at 4 °C and 111,000 ×g in a swing-out rotor (Beckman- Coulter, SW41). The brownish lysosome-enriched fraction (∼ 1ml ...
-
bioRxiv - Physiology 2023Quote: ... and HDL (1.063
g/mL) using NaBr buffers in the Optima MAX-TL Ultracentrifuge with the TLA-100 rotor (Beckman Coulter). Complete blood count analysis was carried out using Heska Element HT5. -
bioRxiv - Cell Biology 2023Quote: ... The gradient was centrifuged at 4 °C and 100,000 ˗ g for 18 h (Optima L-80 XP Ultracentrifuge with Swing Rotor (Beckman Coulter)) ...
-
bioRxiv - Cell Biology 2023Quote: ... tared and ultracentrifuged for 1 h at 110,000x g using a Beckman L7-65 ultracentrifuge with a SW41Ti rotor (#331362, Beckman Coulter). After ultracentrifugation ...
-
bioRxiv - Developmental Biology 2023Quote: ... The resulting supernatant was subjected to ultracentrifugation at 120,000 × g at 4°C for 2 h (Optima Max TL, Beckman Coulter). Pellets were resuspended in 1 ml cold PBS and centrifuged at 120,000 × g at 4°C for 2 h ...
-
bioRxiv - Developmental Biology 2023Quote: ... The top 1 mL was loaded onto a 52% isotonic Percoll solution and centrifuged at 27,000 × g for 10 min at 10°C (Optima-XPN-80, Beckman Coulter). Following centrifugation ...
-
bioRxiv - Pathology 2023Quote: ... The mixture was then layered under a 20–40% discontinuous iodixanol gradient and centrifuged at 260,000 g for 15h at 4°C using an SW 41 Ti Rotor (Beckman Coulter). After spinning ...
-
bioRxiv - Neuroscience 2023Quote: ... the samples were filtered with a membrane pore size of 0.2 μm and centrifuged at 120,000 × g for 4 h at 4 °C in polycarbonate bottle assemblies (Beckman coulter, 355603) in a 70.1 Ti fixed angle rotor (Beckman coulter ...
-
bioRxiv - Microbiology 2023Quote: ... sucrose gradients prepared with buffer C and centrifuged for 16 h at 71,935 g at 4 °C in a SW28 rotor (Beckman Coulter). Gradients were fractionated on a Biocomp Piston Gradient Fractionator (BioComp Instruments ...
-
bioRxiv - Microbiology 2023Quote: ... Medium was cleared from EVs by ultracentrifugation at 100,000 ×g for 18 h at 4°C in a LE-80 ultracentrifuge (Beckman Coulter) with a 60Ti rotor [13] ...
-
Centriole and transition zone structures in photoreceptor cilia revealed by cryo-electron tomographybioRxiv - Cell Biology 2023Quote: ... OptiPrep step-gradient and centrifuged for 60 min at 19,210 × g at 4 °C in a TLS-55 rotor (Beckman Coulter). The ROS band was collected with an 18G needle ...
-
bioRxiv - Cell Biology 2023Quote: ... Small EVs were isolated by ultracentrifugation at 120,000 x g and 4°C for 120 min using Optima XE-90 equipment with a SW32Ti rotor (Beckman Coulter). Supernatants were discarded using a pipette ...
-
bioRxiv - Bioengineering 2023Quote: ... For performing cryogenic transmission electron microscopic imaging EVs were centrifuged and washed in PBS at 100,000 x g for 3 hours at 4°C in a SW41 Ti rotor (Beckman Coulter).