Labshake search
Citations for Beckman :
501 - 550 of 1331 citations for 4 4 7 Triethoxy 7 Methyl 3 8 Dioxa 4 7 Disiladecane since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2021Quote: ... Eluted fractions were pooled and subjected to a 2.5 h ultracentrifugation at 135,500 x g at 4 °C using a TLA-55 rotor (Beckman-Coulter). Finally ...
-
bioRxiv - Biochemistry 2021Quote: ... Reaction mixtures were incubated for 30 minutes and centrifuged at 100,000g at 4°C for 1 hr using a TLA100 fixed angle rotor (Beckman). The supernatant fraction was carefully removed ...
-
bioRxiv - Cancer Biology 2020Quote: ... Lysates were loaded on 15-50% sucrose gradient and centrifuged at 35,000 rpm for 2.5 h at 4°C in a SW41 rotor (Beckman Coulter). Polysomes were separated through a live optical density (OD ...
-
bioRxiv - Molecular Biology 2020Quote: ... Ten OD260 units were loaded on a 10–50% sucrose gradient and centrifuged at 187,813 × g for 2.75 h at 4 °C in a SW41Ti rotor (Beckman Coulter). The fractions of the gradient were collected ...
-
bioRxiv - Cell Biology 2021Quote: ... The crude extract was clarified by high-speed centrifugation (60 min at 36,000 ×g at 4 °C) by Beckman Coulter centrifuge.
-
bioRxiv - Plant Biology 2021Quote: ... A soluble fraction was obtained by ultracentrifugation at 200,000 g for 20 minutes at 4°C on a Beckman Optima Ultracentrifuge (Beckman). Two biological replicates for SEC and IEX column separations were prepared in this manner.
-
bioRxiv - Pharmacology and Toxicology 2021Quote: ... IL-4 and IFN-γ concentrations were determined using DTX 880 Multimode Detector (Beckman Coulter, Inc., Brea, CA, USA) set to 450 nm.
-
bioRxiv - Biochemistry 2021Quote: ... The gradient was centrifuged at 100,000 g for 16 hours at 4°C (rotor MLS-50, Beckman Optima MAX). Twelve fractions of 400 μL were collected from the top of the gradient and pelleted by UC at 100,000 g for 2 hours at 4°C (Figure 1) ...
-
bioRxiv - Biochemistry 2021Quote: ... and 10 mM NH4Cl) and centrifuged for 16 h at 4°C with 18,000 rpm in an SW60Ti rotor (Beckman). Gradients were hand-fractionated and ribosome concentrations were determined by absorbance at 260 nm (A260 ...
-
bioRxiv - Biochemistry 2021Quote: ... Samples were centrifuged at 50,000 rpm (∼166,000 × g) for 3h at 4°C using TLS-55 rotor (Beckman Coulter) in an Optima benchtop ultracentrifuge (Beckman Coulter ...
-
bioRxiv - Biochemistry 2021Quote: ... Membranes were collected by ultracentrifugation at 220 000 x g for 90 min at 4°C (45Ti rotor, Beckman).
-
bioRxiv - Biochemistry 2021Quote: ... and the lysate was clarified by centrifugation at 30,000 x g for 60 min at 4 °C in a JA25.50 rotor in an Avanti J-E centrifuge (Beckman). The clarified lysate was then added to 10 mL of Ni-NTA Agarose beads (Invitrogen ...
-
bioRxiv - Cell Biology 2021Quote: ... Pellets were resuspended in 0.9% NaCl and spun at 110,000 × g for 2 hours at 4°C in an XPN-80 ultracentrifuge equipped with a Type 50.4 Ti rotor (Beckman Coulter ...
-
bioRxiv - Microbiology 2021Quote: ... The VLPs were concentrated by ultracentrifugation for 2 h at 31,000 rpm at 4 °C (Beckman SW-31Ti rotor), and then resuspended in 500 μL of Ex-Cell 405 medium ...
-
bioRxiv - Cell Biology 2021Quote: ... The lysate was clarified by centrifugation for 30 min at 35,000 rpm at 4°C in a Type 45 Ti rotor (Beckman). Cleared lysate was incubated with 2 mL glutathione-sepharose (Fisher Scientific ...
-
bioRxiv - Cell Biology 2021Quote: ... The lysate was clarified by centrifugation for 30 min at 35,000 rpm at 4°C in a Type 45 Ti rotor (Beckman). Cleared lysate was incubated with 2 mL Ni-NTA agarose (Qiagen ...
-
bioRxiv - Immunology 2022Quote: ... stained bacteria were then sonicated for 4 min (0.5 cycle, 75 A, VialTweeter) followed by determination of concentration using flow cytometry (CytoFlex; Beckman Coulter ...
-
bioRxiv - Microbiology 2022Quote: ... Fractions were diluted in 5 ml PBS and washed by ultracentrifugation at 200,000 × g (60 min, 4°C, AH-650 rotor, 5 ml Beckman Ultra-Clear tubes ...
-
bioRxiv - Microbiology 2022Quote: ... 100 ml cell cultures were grown over night and harvested by centrifugation at 15,000 x g for 15 min at 4 °C (Beckman JLA-16.250 rotor ...
-
bioRxiv - Microbiology 2022Quote: ... 100 ml cell cultures were grown over night and harvested by centrifugation at 15,000 x g for 15 min at 4 °C (Beckman JLA-16.250 rotor, Beckman Avanti J-25, Beckman Coulter). Pellets were washed with 20 mM potassium phosphate (pH 7.5 ...
-
bioRxiv - Microbiology 2022Quote: ... The supernatant fractions were collected and centrifuged at 75,600 x g for 90 min at 4 °C (Beckman JA25.50 rotor, Beckman Avanati J-25, Beckman Coulter). The resulting pellets were washed again and resuspended in 500 μl potassium phosphate buffer ...
-
bioRxiv - Biochemistry 2022Quote: ... The lysate was clarified by centrifugation at 48000×g for 45 min at 4°C using a JA-25.50 rotor (Beckman), and applied on a XK 16/20 chromatography column (Cytiva ...
-
bioRxiv - Biochemistry 2022Quote: ... The elutions were combined and centrifuged at 100,000 rpm at 4°C for 40 minutes in a TLA120.2 rotor (Beckman Coulter) before resuspension of the ribosomal pellet in RNC buffer containing 1 μM ternatin-4 ...
-
bioRxiv - Developmental Biology 2022Quote: ... Gradients were centrifuged at 35.000 g for 3h at 4°C in an ultracentrifuge using the SW40ti rotor head (Beckman). Fractions of 1 mL were collected from the top at 1 mL/min ...
-
Reducing mitochondrial ribosomal gene expression does not alter metabolic health or lifespan in micebioRxiv - Cell Biology 2022Quote: ... and then purified using 30% Percoll gradient ultracentrifugation at 95,000g for 30 minutes at +4°C (Beckman sv41 rotor). Purified mitochondria were treated 1:200 with a protease inhibitor cocktail (Thermo Fisher Scientific HALT PI ...
-
bioRxiv - Genomics 2022Quote: ... All samples were acquired on a Beckman Coulter CytoFLEX S with 4 lasers (405nm, 488nm, 561nm, 638nm) (Beckman Coulter), and operated by CytExpert Software v2.3 (Beckman Coulter ...
-
bioRxiv - Neuroscience 2022Quote: ... and ultracentrifuged at 25,000 g for 20 min 4°C (or 50,000 g for 30 min 4°C) in a Beckman TLA100.3 rotor (Optima™ TLX Ultracentrifuge, Beckman). The pellet was discarded ...
-
bioRxiv - Microbiology 2022Quote: ... The gradient was centrifuged at 4°C and 35,000 rpm for 2.5 h using an SW 40 Ti rotor (Beckman Coulter). Afterward ...
-
bioRxiv - Microbiology 2022Quote: ... which was spun in a ultracentrifuge at 30,000 x g for 2h at 4°C (SW 60 Ti rotor, Beckman) The pellet was resuspended in 20 μl of PBS for 1 h at 4 °C ...
-
bioRxiv - Molecular Biology 2023Quote: ... The gradients were centrifuged at 38,300 rpm for 2 hours and 45 min at 4 °C in a SW-40Ti (Beckman) rotor using an Optima XE-100 Ultracentrifuge (Beckman) ...
-
bioRxiv - Molecular Biology 2023Quote: ... The gradients were centrifuged at 38,300 rpm for 2 hours and 45 min at 4 °C in a SW-40Ti (Beckman) rotor using an Optima XE-100 Ultracentrifuge (Beckman) ...
-
bioRxiv - Plant Biology 2023Quote: ... Extract was then centrifuged at 40 000 rpm for 2 hours at 4°C using the 50Ti rotor (Beckman). A protocole previsouly used in the laboratory and described in Maclot et al ...
-
bioRxiv - Microbiology 2022Quote: ... Glycoproteins in the supernatants were pelleted by centrifugation at 100,000×g at 4°C for 90 min using a TLA-55 rotor (Beckman). The resultant pellets ...
-
bioRxiv - Microbiology 2022Quote: ... The post-nuclear supernatant was adjusted to 0.8 M sucrose and loaded in the middle of a step gradient ranging from 0.1 to 1.8 M sucrose in STKM buffer and centrifuged at 50’000 g for 1 h at 4°C in a TLA-120.1 fixed-angle rotor (Beckman Coulter). LDs formed a white cushion on top of the tube and were collected by aspiration of the upper fraction of the gradient (125 µl).
-
bioRxiv - Microbiology 2022Quote: ... The gradient was spun at 45,000 rpm (~200,000 x g) for 6 hours at 4 °C in a SW60Ti rotor (Beckman Coulter). Successive 0.4 mL fractions were collected by pipetting and their densities measured ...
-
Ribonuclease Inhibitor and Angiogenin collaboratively regulate cell-type-specific global translationbioRxiv - Biochemistry 2024Quote: ... and were centrifuged at 39,000 rpm for 2.45 hours at 4°C using Optima XPN-80 Ultracentrifuge (Beckman Coulter). Following centrifugation ...
-
bioRxiv - Molecular Biology 2024Quote: ... Virus was then purified by centrifugation through a 20% sucrose cushion at 25,000 rpm for 2.5 hours at 4 °C in a Sw32Ti rotor (Beckman Coulter). Virus pellets were resuspended in PBS and virus genomic RNA copy number was quantified by RTqPCR as described above ...
-
bioRxiv - Neuroscience 2024Quote: ... by centrifugation at 5,000 x g at 4°C for 30 minutes in a fixed angle rotor (Beckman Coulter). The qEV column washed with 1x PBS was then loaded with 500 µL of concentrated supernatant followed by 2.5 mL PBS to collect 3 mL void volume ...
-
bioRxiv - Molecular Biology 2024Quote: ... for ultracentrifugation at 100,000 × g for 1 hour at 4°C (JXN-30 centrifuge, JA-30.50 Ti Rotor, Beckman Coulter). The pellet was washed with PBS and centrifuged again at 100,000 × g for 1 hour at 4°C to remove soluble contaminant ...
-
bioRxiv - Neuroscience 2024Quote: ... and PBS was added to reach a 4.5 mL tube filling and centrifuged at 120,000xg for 100 min at 4°C in the L-60 Optima Ultracentrifuge (Beckman Coulter ...
-
bioRxiv - Cell Biology 2024Quote: ... The supernatant was then subjected to ultracentrifugation at 100,000 x g for 2 h at 4 °C to sediment small EVs (Optima L-80K ultracentrifuge, Beckman Coulter ...
-
bioRxiv - Molecular Biology 2024Quote: ... and 1 M sucrose) at 100,000 rpm (543,000 × g) and 4°C for 1 h with a TLA110 rotor (Beckman Coulter) and an Optima MAX-TL Ultracentrifuge (Beckman Coulter) ...
-
bioRxiv - Cell Biology 2024Quote: ... samples were ultracentrifuged at 160,000 xg for 2 h at 4 °C in ultracentrifuge tubes (Beckman Coulter Cat #328874). The resulting pellet contained the insoluble AMB-1 cell fraction and the supernatant contained the soluble fraction ...
-
bioRxiv - Cancer Biology 2024Quote: ... 100 μg/mL cycloheximide) for 2 h at 40,000 g at 4 °C using an SW41 rotor (Beckman Coulter). Gradients were fractionated using Teledyne Isco Tris Peristaltic Pump and fractions were collected and pooled according to the UV trace ...
-
bioRxiv - Biophysics 2024Quote: ... Each seed mix was clarified using an ultra-centrifuge (Beckman Optima MAX-XP, 90,000 RPM, 4°C, 5 min) then snap-frozen in small aliquots and stored at -80°C ...
-
bioRxiv - Biochemistry 2023Quote: ... lysates were centrifuged at 60,000 x g (4 °C) for 45 min (Beckman Avanti JXN-26 (rotor: JA 25.5)) and immediately supplemented with 10 mL pre-washed Ni2+-NTA agarose (QIAGEN ...
-
bioRxiv - Neuroscience 2023Quote: ... DTT-treated EVs were pelleted at 100,000 x g for 70 min at 4°C in a TLA100 rotor (Beckman). The supernatant ...
-
bioRxiv - Neuroscience 2023Quote: ... The prepared gradients were centrifuged at 200,000 x g for 16 h at 4°C in an SW41Ti rotor (Beckman), with no braking during deceleration ...
-
bioRxiv - Neuroscience 2023Quote: ... The pellet was resuspended in 4.5 volumes of ice-cold extraction buffer and re- centrifuged at 11,300 RPM for 10 min at 4°C using a Ti45 rotor (Beckman). The supernatant was filtered through a 70 μm pore size cell-strainer and combined with the first supernatant ...
-
bioRxiv - Neuroscience 2023Quote: ... The tube was topped up to 23 mL with PBS and centrifuged at 59,300 RPM for 30 min at 4°C using a Ti70 rotor (Beckman). The floating lipid layer and supernatant were discarded and the pellet was transferred to a 2 mL tube in 50 μL PBS per g initial grey matter ...