Labshake search
Citations for Beckman :
451 - 500 of 1854 citations for trans 2 2 4 Bromophenyl 2 oxoethyl cyclohexane 1 carboxylic acid since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cell Biology 2021Quote: ... Hettich) at 4°C and then centrifuged at 40000 rpm for 4h30 at 4°C using SW41Ti rotor (Beckman). The supernatant was then UV inactivated at a wavelength of 254 nm for 4 min (3 times ...
-
bioRxiv - Microbiology 2023Quote: ... The lysates containing matured PsVs were loaded on an OptiPrep gradient that had been stabilized at least 1 h and centrifuged at 50k x g for 3.5-4 h at 4°C in a SW-55Ti rotor (Beckman). Fractions were collected in siliconized tubes and subjected to SDS-PAGE followed by Coomassie blue staining to assess the abundance of L1 and L2 proteins ...
-
bioRxiv - Microbiology 2024Quote: ... The lysates containing matured PsVs were loaded on an OptiPrep gradient that had been stabilized at least 1 h and centrifuged at 50k ×g for 3.5-4 h at 4°C in a SW-55Ti rotor (Beckman). Fractions were collected in siliconized tubes and subjected to SDS-PAGE followed by Coomassie blue staining to assess the abundance of L1 and L2 proteins ...
-
bioRxiv - Genetics 2024Quote: ... and spun at 70,000 rpm for 4 hours at 4°C using a TLA 100.3 Rotor in an Optima Ultracentrifuge (Beckman, 361889). After centrifugation ...
-
bioRxiv - Microbiology 2024Quote: ... and the remainder was then loaded onto a 20%-60% sucrose cushion and centrifuged at 25,000 rpm at 4°C for another 4 hours using the SW41 rotor (Beckman). The initial 5 μL sample and each sucrose gradient layer were then absorbed ...
-
bioRxiv - Biophysics 2020Quote: ... The lysates were clarified by centrifugation (16,000 rpm for 1 h at 4°C, rotor JA 25.50, Beckman Coulter, Brea, California, USA). The supernatant was incubated with amylose resin for 1 h at 4°C and loaded onto a 20 ml chromatography column (Bio-Rad ...
-
bioRxiv - Systems Biology 2020Quote: ... Next the cultures were diluted 1:40 with 0.5M NaCl and immediately measured in Multisizer™4 COULTER COUNTER® (Beckman Coulter) (Coulter ...
-
bioRxiv - Plant Biology 2020Quote: ... Double size selection was carried out by adding 50 μL of a 1:4 (0.5X) mixture of AMPure XP Beads (Beckman Coulter, Brea, USA) to PEG buffer (20% PEG w/v ...
-
bioRxiv - Molecular Biology 2023Quote: ... The cell lysate was centrifuged at 4 °C at 35000 rpm for 1 hour with Beckman Optima™ L-80XP Ultracentrifuge equipped with Ti45 rotor (Beckman, USA). The pellet containing membranes and cell debris was discarded ...
-
bioRxiv - Neuroscience 2022Quote: ... The loaded gradient was ultracentrifuged at 69,150 x g for 1 h at 4 °C (SW 41 Ti Swinging-Bucket Rotor, Beckman Coulter, Cat. #331362) and the synaptosome fraction was harvested from the interface between the two sucrose layers ...
-
bioRxiv - Cell Biology 2023Quote: ... the supernatants were transferred into SW60 tubes (in vivo studies 1–4) or SW40 tubes (donated patients) (Beckman Coulter Inc., Brea, USA) and centrifuged at 10,000xg for 35 minutes ...
-
bioRxiv - Neuroscience 2024Quote: ... The supernatant was segregated subsequent to centrifuging the brain tissue homogenate for 1 h at 100,000g and 4°C utilising an ultra-high-speed centrifuge (Beckman, Optima MAX-XP). The tissue residue was then reprocessed ...
-
bioRxiv - Microbiology 2024Quote: ... The top agar was then scraped off the LB agar and centrifuged for 26,000 x g at 4°C for 1 hour (Beckman Coulter JA-17). The supernatant was then removed ...
-
bioRxiv - Microbiology 2024Quote: ... Crude ribosomes were separated from other low molecular weight cellular contents by centrifugation at 35000 rpm (126,000g) for 1 hour at 4 °C (Beckman rotor Type 70Ti). The crude ribosome pellet was resuspended in 10 mL HMA-10 buffer and layered on top of a 10 mL 32% sucrose solution in HMA-10 buffer and centrifuged for 16 hours at 37,000 rpm (140,000g ...
-
bioRxiv - Neuroscience 2024Quote: ... The PNS- Nycodenz gradient was centrifuged for 1 h at 141,000 x g at 4°C (46,000 rpm, TLS-55 rotor, Beckman Coulter Optima TLX Ultracentrifuge). After centrifugation ...
-
bioRxiv - Biochemistry 2020Quote: ... which were centrifuged at 50,000rpm for 4 hours at 4°C using a TLS55 rotor and an Optima MAX-XP Ultracentrifuge (Beckman Coulter). The sample was physically fractionated into 10 fractions of 85 uL each ...
-
bioRxiv - Molecular Biology 2022Quote: ... 800 µl of EDTA-treated lysate was layered on top of the sucrose gradient and ultracentrifuged at 35000 rpm for 4 hours at 4 °C in a SW41Ti rotor (Beckman). After centrifugation ...
-
bioRxiv - Immunology 2020Quote: ... all CCMV CP preparations were purified two times using an ultracentrifuge and 30% sucrose cushion – first with additional 0.5% Triton X-100 and the second time without Triton X-100 (4 h, 50 000 rmp, 4°C; Type 70Ti rotor, Beckman) and the pellet was then dissolved in buffer A ...
-
bioRxiv - Cell Biology 2022Quote: ... 4–40% sucrose gradient prepared in lysis buffer and centrifuged at 150,000 × g for 4 or 16 h at 4°C in a MLS-50 rotor (Beckman Coulter). Thereafter ...
-
bioRxiv - Neuroscience 2023Quote: ... the samples were filtered with a membrane pore size of 0.2 μm and centrifuged at 120,000 × g for 4 h at 4 °C in polycarbonate bottle assemblies (Beckman coulter, 355603) in a 70.1 Ti fixed angle rotor (Beckman coulter ...
-
bioRxiv - Cell Biology 2020Quote: ... 4°C in a TLA 100.3 rotor (Beckman). P13 ...
-
bioRxiv - Cell Biology 2022Quote: ... 4°C (Type 45 Ti rotor, Beckman Coulter) for 30 min to collect supernatant ...
-
bioRxiv - Biochemistry 2020Quote: ... 4 °C (Beckman Coulter Optima LE-80K Ultracentrifuge). The clarified lysate was placed in a beaker on a stir plate at 4 °C and concentrated ammonium sulfate (5 mM HEPES pH 7.5 ...
-
bioRxiv - Neuroscience 2020Quote: ... for 4 h with SW28 rotor (Beckman Coulter). The concentrated vector was stored at −80 °C until use ...
-
bioRxiv - Biochemistry 2022Quote: ... 4 °C on a Sorvall WX90 ultracentrifuge (Beckman) with SW55Ti rotor ...
-
bioRxiv - Molecular Biology 2022Quote: ... 4°C in SW-41Ti rotor (Beckman Coulter). Subsequently ...
-
bioRxiv - Plant Biology 2021Quote: ... 4 °C for 18 h (Beckman SW41 rotor). The sugar solution contains 0.65 M sucrose ...
-
bioRxiv - Biochemistry 2022Quote: ... 4°C using a SW41Ti rotor (Beckman Coulter). A BioComp fractionator was used to collect fractions 1 – 16 ...
-
bioRxiv - Neuroscience 2022Quote: ... at 4°C in a Beckman ultracentrifuge (Beckman). After centrifugation ...
-
bioRxiv - Systems Biology 2022Quote: A particle size analyzer (Multisizer 4, Beckman Coulter) was used to count the number of cells ...
-
bioRxiv - Microbiology 2024Quote: ... 4 °C (Beckman Coulter, JA 25-50 rotor) for 10 min ...
-
bioRxiv - Microbiology 2024Quote: ... 4°C (Beckman Coulter, JA 25-50 rotor) for 10 min and the cell lysates were incubated with 1 mL of prewashed Ni-NTA Agarose beads (QIAGEN ...
-
bioRxiv - Molecular Biology 2021Quote: ... triglycerides and non-esterified fatty acids using a serum analyzer (AU480 Chemistry analyzer Beckman Coulter). Plasma levels of leptin and insulin were assessed using ELISAs used according to the manufacturer’s instructions (R&D Systems ...
-
bioRxiv - Immunology 2020Quote: ... nucleic acids were extracted from sorted single cell using RNAClean XP SPRI beads (Beckman Coulter), and RNA was hybridized first using RT primer (/5BiosG/AAGCAGTGGTATCAACGCAGAGTACTTTTTTTTTTTTTTTTTTTTTTTTTTTTT TVN ...
-
bioRxiv - Biochemistry 2020Quote: ... The sample was centrifuged at 4°C for 1 hour and 40 minutes at 182,753 x g (38,000 rpm in a Beckman Coulter Type 42.2 Ti rotor).
-
bioRxiv - Molecular Biology 2021Quote: ... 1 mM ATP and 1 mM PMSF) and centrifuged for 15 h at 4°C and 74 400 x g (Beckman SW 32.1 Ti). From the gradient ...
-
bioRxiv - Pharmacology and Toxicology 2024Quote: ... the cell lysate was layered on top of a discontinuous OptiPrep® gradient (50 %, 35 %, 30 %, 20 %, and 15 %) and centrifuged at 135,000 g for 1 h at 4°C (Beckman L8-80M Ultracentrifuge, USA). The melanin pellet was recovered ...
-
bioRxiv - Microbiology 2024Quote: ... The 1 ml fraction containing the phage was then placed on a 40% (w/v) - 60% (w/v) sucrose gradient for 1 hour at 63,400 x g at 4°C (Beckman Coulter SW 40 Ti). The 1 ml fraction was then placed in a 50 kDa dialysis membrane (Spectrum Labs ...
-
bioRxiv - Biochemistry 2024Quote: ... The A2aR-expressing membrane fraction was obtained by ultra- centrifugation at 100,000 g for 1 hour at 4°C in a Type 70 Ti Fixed-angle rotor (Optima XPN ultracentrifuge, Beckman Coulter Life Sciences). The pellet (membrane fraction ...
-
bioRxiv - Neuroscience 2021Quote: ... 4 × 5-s bursts) and subsequently centrifuged at 48,000g at 4°C (Beckman Avanti J-251 Ultracentrifuge; Beckman Coulter, Fullerton, CA) for 30 min ...
-
bioRxiv - Immunology 2021Quote: ... were incubated with monoclonal antibodies at 4°C for 30 min and then fixed with 4% paraformaldehyde before analysis on a Cytoflex cytometer (Beckman Coulter). Data were analyzed by Flow Jo software v.10.7 (BD Biosciences) ...
-
bioRxiv - Cell Biology 2021Quote: ... and loaded onto of a step-wise sucrose gradient as described by the manufacturer and subjected to ultracentrifugation at 150,000 xg for 4 h at 4 °C using SW50.1 rotor (Beckman Coulter, Mississauga, ON). Fractions were then collected and subject to denaturation with Laemmli buffer until further use.
-
bioRxiv - Molecular Biology 2024Quote: ... They were cherrypicked from the original library plates and 4 crRNAs per target were pooled (4 x10 μl) and re-arrayed using a Biomek-FX automated pipetting system (Beckman Coulter). Edit-R CRISPR-Cas9 Synthetic tracrRNA (Horizon Discovery Biosciences ...
-
bioRxiv - Systems Biology 2020Quote: ... and the resultant supernatant was ultracentrifuged at 100,000xg for 40 minutes at 4°C (rotor TLA 120.2; Beckman Coulter 343778 1 ml uncapped tubes).
-
bioRxiv - Physiology 2021Quote: ... sEV were further isolated from lEV-depleted supernatants following a 100,000 xg ultracentrifugation step for 1 hour at 4°C (rotor MLA-50, Beckman Coulter Optima MAX-XP Ultracentrifuge) and two washes in NaCl before resuspension in NaCl.
-
bioRxiv - Biophysics 2023Quote: ... Cell debris was removed by centrifugation at 20,000 rpm at 4°C for 1 h (Avanti® J-E centrifuge from Beckman Coulter, rotor: JLA 25.50). The supernatant was collected and loaded onto a pre-equilibrated 5 ml His-Trap FF crude column ...
-
bioRxiv - Microbiology 2020Quote: ... The supernatant was filtered by 0.22 μm nylon membrane followed by centrifugation through a cushion of 50 % (w/v) sucrose with 36,000 rpm at 4 °C for 4 h (Beckman SW41 Ti rotor). The pellet was resuspended with PBS and the copy number of DWV was quantified by qRT-PCR.
-
bioRxiv - Biophysics 2024Quote: ... The gradients were then centrifuged at 187,000 × g for 4 h at 4°C in a SW 41 Ti rotor (Beckman Coulter, Brea, CA). Bands corresponding to purified virus particles (∼1.36 g/mL ...
-
bioRxiv - Microbiology 2020Quote: ... 4°C in SW 60 Ti rotor (Beckman Coulter) to pellet cyanophage particles ...
-
bioRxiv - Immunology 2021Quote: ... CD38 APC-AF700 (clone LS198-4-3; Beckman Coulter), CD19 APC-Cy7 (clone SJ25C1 ...