Labshake search
Citations for Beckman :
451 - 500 of 1669 citations for Human Chemokine C X C Motif Receptor 5 CXCR5 Protein since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2020Quote: ... and centrifuged at 140,000 × g for 70 min at 4°C (# Optima-XE SW41 Beckman Coulter). The pellet was resuspended in 2 mL of 0.475M of sucrose solution (# S5-3 Fisher science ...
-
bioRxiv - Biochemistry 2020Quote: ... subjected to centrifugation (36,000 rpm for 3 hours at 4 °C, SW-41Ti Beckman Coulter rotor) and analysed using Biocomp Gradient Station (BioComp Instruments ...
-
bioRxiv - Cancer Biology 2020Quote: ... for 30 min at 37°C and cleaned by 1.2× volumes of SPRI beads (Beckman Coulter). Next ...
-
bioRxiv - Molecular Biology 2020Quote: ... Samples were ultracentrifuged at 95,000 rpm at 4°C for 2h using a TLA100.2 rotor (Beckman). The pellets were resuspended in 200 µL of W-Buffer and treated with 1% SDS (Sigma cat ...
-
bioRxiv - Biochemistry 2019Quote: ... After centrifugation of the lysate (JA-20 rotor, Beckman Coulter, 25000 g, 60 min, 4°C) the supernatant was loaded onto a Ni-NTA Agarose (Qiagen ...
-
bioRxiv - Microbiology 2019Quote: ... performed ultracentrifugation (40,000 rpm, either 4 h or 18 h, +4 °C, SW41 rotor, Beckman Coulter), and collected approximately 600 μl fractions by puncturing the tubes with a thin (23G or 25G ...
-
Plasma derived cell-free mitochondrial DNA originates mainly from circulating cell-free mitochondriabioRxiv - Genomics 2021Quote: ... and finally centrifuged at 200,000 g for 2h at 4°C (Beckman MLA-130 Ultracentrifuge Rotor). After each centrifugation step ...
-
bioRxiv - Biochemistry 2020Quote: ... The microtubules were pelleted at 90,000 rpm for 10 min at 37°C (TLA120.1 Beckman Coulter) and re-suspended in warm (37°C ...
-
bioRxiv - Microbiology 2020Quote: ... Gradients were resolved at 35,000 rpm for 2.5 hours at 4 °C in SW41 rotor (Beckman) and analysed and fractionated using Biocomp Gradient Station (BioComp Instruments ...
-
bioRxiv - Molecular Biology 2022Quote: ... for 1 additional hour at 55°C and purified using 2x AMPure XP beads (Beckman Coulter). The generated libraries were amplified using the KAPA HiFi Hotstart Ready Mix and Nextera Index Kit 1 (i7 ...
-
bioRxiv - Plant Biology 2022Quote: ... and centrifuged at 45,000 rpm for 65 min at 4°C (Sorval NVT 90; Beckman Coulter). In parallel ...
-
bioRxiv - Biophysics 2022Quote: ... 100µL samples were then centrifuged at 42000rpm for 30min at 4°C (Beckman TLA 100 rotor). 2 fractions were isolated from these samples ...
-
bioRxiv - Neuroscience 2023Quote: ... and centrifuged at 53,000 RPM for 40 min at 4°C using a Ti70 rotor (Beckman). The supernatant was discarded and the pellet was transferred to a 2 mL tube in 50 μL PBS per g initial grey matter and resuspended by sonication using a Hielscher S26D11X10 Vial-Tweeter-Sonotrode in 0.5 s pulses at 100% amplitude for a total accumulated power of 200 W ...
-
bioRxiv - Cancer Biology 2023Quote: ... and ultracentrifuged at 100,000g for 90 min at 4°C (Optima L-90K Ultracentrifuge, Beckman Coulter). Pelleted EVs were resuspended in 200 μl PBS ...
-
bioRxiv - Cancer Biology 2023Quote: ... The cells were further grown overnight at 18°C and spun down by centrifugation (Beckman Coulter). A french press (Thermo Spectronic ...
-
bioRxiv - Biochemistry 2023Quote: ... The crude lysate was centrifuged for 1 hour at 20,000 rpm and 4 °C (Beckman Coulter). The supernatant was filtered using a 0.44 μm syringe filter (Sartorius ...
-
bioRxiv - Biophysics 2023Quote: ... The cell lysate was centrifuged at 4 °C at 35000 rpm for 1 hour by Beckman Optima™ L-80XP ultracentrifuge equipped with a Ti-45 rotor (Beckman ...
-
bioRxiv - Immunology 2023Quote: ... and spun for 100 min at 38,000rpm at 4°C in a SW41Ti rotor (Beckman Ultracentrifuge). Gradients were syringe-fractionated mechanically from the bottom up and monitored for absorbance at 254nm (Teledyne Isco ...
-
bioRxiv - Microbiology 2023Quote: ... The gradient was centrifuged at 32,700 rpm for 18h at 4°C (Beckman SW41-Ti rotor). After the centrifugation ...
-
bioRxiv - Microbiology 2023Quote: ... Virions were then pelleted by ultracentrifugation (22 krpm, 90 min, 4 °C, Beckman-Coulter rotor SW28) on a 5-mL cushion of 30% sucrose ...
-
bioRxiv - Biochemistry 2023Quote: ... followed by lysate centrifugation at ∼28500g for 1h at 4°C (Beckman Coulter centrifuge, JA-14). The supernatant was incubated for 45min ...
-
bioRxiv - Biochemistry 2023Quote: ... the lysate was centrifuged at ∼28500g for 1h30 at 4°C (Beckman Coulter centrifuge, JA-14) and the supernatant incubated for 1h ...
-
bioRxiv - Biochemistry 2023Quote: ... the lysate was centrifuged at ∼18000g for 1h at 4°C (Beckman Coulter centrifuge, JA-20) and the supernatant incubated for 45min ...
-
bioRxiv - Pharmacology and Toxicology 2024Quote: ... 18 ◦C for 1 h 45 min in a 50.2Ti rotor (Beckman-Coulter, Brea, CA, USA). After ultracentrifugation ...
-
bioRxiv - Cell Biology 2020Quote: ... 4°C for 60 minutes to isolate S-EV (Optima XL-80K, Beckman Coulter Lifesciences, Tokyo, Japan). The plasma samples were centrifuged similarly but without the 300xg centrifugation.
-
bioRxiv - Cell Biology 2020Quote: ... and gradients were spun 100,000rpm for 20min at 20°C in a TLA-100 ultracentrifuge rotor (Beckman). Top layers were collected ...
-
bioRxiv - Cell Biology 2020Quote: ... The lysate was centrifuged at 100,000 × g for 30 min at 4°C in a 70.1Ti Rotor (40,000 rpm; Beckman). The supernatant in centrifuge tubes was immersed in boiling water (95°C ...
-
bioRxiv - Evolutionary Biology 2020Quote: ... 20 min at 20 000 g to pellet mitochondria (8 °C, 11 300 RPM, Beckman JA-13.1), 40 min at 20 000 g (8 °C ...
-
bioRxiv - Evolutionary Biology 2020Quote: ... and further centrifuged 20 min at 20 000 g (8 °C, 11 300 RPM, Beckman JA-13.1) to pellet mitochondria after Percoll removal by dilution with 40 mL mitochondrial wash buffer (250 mM Sorbitol ...
-
bioRxiv - Neuroscience 2021Quote: ... for 30 minutes at 50°C and DNA fragments were purified using Ampure XP beads (Beckman Coulter). The library preparation was conducted by Diagenode ChIP-seq/ChIP-qPCR Profiling service (Diagenode Cat# G02010000 ...
-
bioRxiv - Molecular Biology 2021Quote: ... 25°C) and IP-DNA was finally purified from supernatant using AMPure XP magnetic beads (Beckman Coulter). Enrichment was assessed with qPCR for several genomic loci (Table S1) ...
-
bioRxiv - Biochemistry 2020Quote: ... viruses were concentrated by centrifugation at 100,000 × g and 4°C in a Ty45 Ti rotor (Beckman) for 2 hours ...
-
bioRxiv - Biophysics 2019Quote: ... and centrifuged at 5000 xg for 30 minutes at 4°C and subsequently at 10000 xg (Beckman Coulter Optima L-90K with a SW40Ti rotor) ...
-
bioRxiv - Cell Biology 2019Quote: ... and centrifuged at 200,000 g for 3 h at 4°C in a TLS55 rotor (Beckman Coulter). The sucrose gradient was fractionated manually from the top ...
-
bioRxiv - Biophysics 2019Quote: ... then spun at 36,000 × g for three hours at 4°C (Type 45 Ti rotor, Beckman Coulter) to pellet OMVs ...
-
bioRxiv - Biophysics 2021Quote: ... the supernatant containing unbound cyt c was carefully removed and saved for UV-vis spectrophotometer (Beckman Coulter) measurement ...
-
bioRxiv - Bioengineering 2020Quote: ... EVs were pelleted by ultracentrifugation at 100,000xg for 120 minutes at 4°C (SW28 rotor, Beckman Coulter). Additionally ...
-
bioRxiv - Bioengineering 2021Quote: ... After centrifugation at 15,000 rpm at 4°C for 0.5 h in an JA-30.50 rotor (Beckman), the obtained soluble extract was mixed with 2 ml slurry Ni-NTA beads (30210 ...
-
bioRxiv - Bioengineering 2020Quote: ... 4°C) in a Beckman J2-21 centrifuge fitted with a fixed-angle JA-14 rotor (Beckman Instruments Inc. ...
-
bioRxiv - Biochemistry 2021Quote: ... After centrifugation at 15,000 rpm at 4°C for 0.5 h in an JA-30.50 rotor (Beckman), the obtained soluble extract was mixed with 2 ml slurry Ni-NTA beads (30210 ...
-
bioRxiv - Biochemistry 2021Quote: Sedimentation velocity experiments were carried out at 20°C in an XL-I analytical ultracentrifuge (Beckman Coulter). Samples were spun using an An60Ti rotor and 12-mm double sector epoxy centerpieces ...
-
bioRxiv - Biochemistry 2020Quote: The cell lysates obtained after sonication were centrifuged (16000 rpm, JA-17, 45 min, 4 °C, Beckman) to remove unlysed cells and other high molecular weight debris ...
-
Dissecting β-Cardiac Myosin and Cardiac Myosin-Binding Protein C Interactions using a Nanosurf AssaybioRxiv - Biophysics 2022Quote: ... Lysates were centrifuged (176,000g, 4°C, 25 min) in a TLA 100.4 rotor (Beckman Coulter, Brea, CA) and bound to anti-FLAG M2 affinity resin (Sigma-Aldrich ...
-
bioRxiv - Cell Biology 2022Quote: ... Homogenates were ultracentrifuged (4 °C for 60 min) at 100,000×g (Optima MAX Preparative Ultracentrifuge, Beckman Coulter). Supernatants (S1 fractions) ...
-
bioRxiv - Neuroscience 2022Quote: ... Homogenates were ultracentrifuged (4 °C for 60 min) at 100,000×g (Optima MAX Preparative Ultracentrifuge, Beckman Coulter). Supernatants ...
-
bioRxiv - Microbiology 2022Quote: ... The immunoturbidimetric test was used to assess serum complement (C) and immunoglobulin antibodies (AU5421; Beckman Coulter, USA). Immunoblotting and immunofluorescence were used to detect serum autoantibodies ...
-
bioRxiv - Biochemistry 2022Quote: ... Polymerised MTs were pelleted at 313,000g for 10 min at 25°C using TLA100 rotor (Beckman Coulter), and the pellet was washed with BRB80 buffer ...
-
bioRxiv - Molecular Biology 2022Quote: ... and centrifuged at 100,000 g for 1 h at 4°C in a TLA100.3 rotor (Beckman Coulter). Top (T ...
-
bioRxiv - Microbiology 2019Quote: ... The samples were centrifuged at 158,000 × g for 18h at 4°C on a SW55Ti rotor (Beckman). Finally ...
-
bioRxiv - Neuroscience 2021Quote: ... it was centrifuged at 110 000×g for 1 hour at 4°C (Optima TLX Ultracentrifuge, Beckman) and the fat-free infranatant was used for HSL activity measurements ...