Labshake search
Citations for Beckman :
451 - 500 of 1888 citations for 6 Chloro 3 4 dihydro 4 methyl 3 oxo 2H 1 4 benzoxazine 8 carboxylic Acid d3 Methyl Ester since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cancer Biology 2024Quote: ... Lysates were then separated by centrifugation at 30,000 rpm and 4°C in an SW41Ti rotor (Beckman) for 18 hours ...
-
bioRxiv - Neuroscience 2024Quote: ... An equimolar pool of 4 barcoded libraries was cleaned up with 0.8x AMPure XP beads (Beckman Coulter). The pools were quantified and assessed with Qubit and Femto ...
-
bioRxiv - Biophysics 2024Quote: ... the gradient was centrifuged at 107,000xg for 16 hours at 4 °C (SW 40 rotor, Beckman Coulter). After centrifugation ...
-
bioRxiv - Genomics 2024Quote: ... the virus was ultra-centrifuged at 24,000 rpm at 4 C° for 2 h using SW32Ti (Beckman) and the virus pellets were resuspended in RPMI media with 10% FBS to result in a 20-fold concentrated virus and stored at −80 C°.
-
bioRxiv - Biochemistry 2024Quote: ... The gradients were run overnight at 4 ℃ in an SW 41 Ti swinging bucket rotor (Beckman Coulter) and subject to 5.45×1011 ω2t total centrifugal force (27,000 rpm ...
-
bioRxiv - Biochemistry 2024Quote: ... The crude membrane fraction was isolated by ultracentrifugation (100000g, 45 min, 4 °C, Beckman Coulter rotor Ti70). Membranes were resuspended in Buffer A at 5 mg/mL and stored at -80°C for later use.
-
bioRxiv - Systems Biology 2020Quote: ... and the resultant supernatant was ultracentrifuged at 100,000xg for 40 minutes at 4°C (rotor TLA 120.2; Beckman Coulter 343778 1 ml uncapped tubes).
-
bioRxiv - Physiology 2021Quote: ... sEV were further isolated from lEV-depleted supernatants following a 100,000 xg ultracentrifugation step for 1 hour at 4°C (rotor MLA-50, Beckman Coulter Optima MAX-XP Ultracentrifuge) and two washes in NaCl before resuspension in NaCl.
-
bioRxiv - Biophysics 2023Quote: ... Cell debris was removed by centrifugation at 20,000 rpm at 4°C for 1 h (Avanti® J-E centrifuge from Beckman Coulter, rotor: JLA 25.50). The supernatant was collected and loaded onto a pre-equilibrated 5 ml His-Trap FF crude column ...
-
bioRxiv - Biochemistry 2020Quote: ... Lysates were cleared by ultracentrifugation (25000 rpm for 30 min at 4°C using a Beckman Ti45 rotor). Supernatant was filtered (0.45 μm ...
-
bioRxiv - Biochemistry 2020Quote: ... Lysates were cleared by ultracentrifugation (40000 rpm for 30 min at 4°C in a Beckman Ti45 rotor). Supernatant was filtered (0.45 μm ...
-
bioRxiv - Biochemistry 2020Quote: ... Lysates were cleared by ultracentrifugation (40000 rpm for 30 min at 4°C in a Beckman Ti45 rotor). Supernatant was filtered (0.45 μm ...
-
bioRxiv - Cell Biology 2020Quote: ... and then centrifuged (300 g for 5 min at 4 °C) (Allegra X-30R Centrifuge, Beckman Coulter, USA) to obtain the myofiber-associated cell pellet ...
-
bioRxiv - Cell Biology 2020Quote: ... and then centrifuged (300 g for 5 min. at 4 °C) (Allegra X-30R Centrifuge, Beckman Coulter, USA) to obtain the myofiber-associated cell pellet ...
-
bioRxiv - Molecular Biology 2021Quote: ... RNA concentration of the cleared lysate was measured by nanodrop and 500 μg of this RNA was loaded onto the gradient and run for 2.5 hr at 220,000 g and 4°C in an SW41-rotor (Beckman). Gradients were then run at 850 μL/min in a density gradient fractionation system (Teledyne Isco) ...
-
bioRxiv - Molecular Biology 2021Quote: ... Gradients were centrifuged at 36000 RPM for 2 hours at 4°C in a SW41 rotor (Beckman Coulter) and then fractions were collected using a gradient collector (Teledyne ISCO gradient station ...
-
bioRxiv - Microbiology 2022Quote: ... for 3h at 4°C in a Beckman ultracentrifuge with the SW40ti rotor head (Beckman, Brea, California, USA) using open top polyallomer tubes (Seton Scientific ...
-
bioRxiv - Bioengineering 2021Quote: ... The resulting solution was centrifuged at 164,000 × g (30,000 rpm) for 4 h at 20°C (Optima XPN-80 Ultracentrifuge, Beckman) to remove any remaining nanotube aggregates.
-
bioRxiv - Bioengineering 2020Quote: ... larger vesicles were depleted by centrifugation for 30 minutes at 10,000xg at 4°C (SW28 rotor, Beckman Coulter). In the final step ...
-
bioRxiv - Biochemistry 2020Quote: ... 300mM NaCl (pH 7.0) was performed at 4 ⁰C on an Optima XL-A Analytical Ultracentrifuge (Beckman Coulter). Equilibrium radial distributions at 10,000 and 15,000 RPM of Sfh5 at concentrations of 10 ...
-
bioRxiv - Plant Biology 2021Quote: ... The supernatant was transferred into new centrifuge tubes and centrifuged at 40,000g (P40) or 100,000g (P100) for one hour (4°C, TLA100.3, Optima TLX Ultracentrifuge; Beckman Coulter) to pellet EVs and other particles as noted in figure legends ...
-
bioRxiv - Biochemistry 2020Quote: ... Beckman CoulterTM at 150.000 g for 120 minutes at 4°C with a TLA-55 Rotor (Beckman CoulterTM) to pellet EVs ...
-
bioRxiv - Microbiology 2020Quote: ... Then 4 ml of the adjusted lipoprotein was layered under 8 ml of 0.9% NaCl and centrifuged at 49,000 rpm for 4 hours at 10°C (NVTi 65 rotor; Beckman). The HDL (lower band ...
-
bioRxiv - Microbiology 2020Quote: ... Purification was done by ultracentrifugation for 2 h at 154,000xg at 4°C in a SW41 rotor (Beckman) using a two-step sucrose gradient (20%/50% w/v in HNE) ...
-
bioRxiv - Biochemistry 2021Quote: ... and separated by ultracentrifugation in a TLA120.2 rotor (Beckman Coulter; 1.5 h at 278,000 x g, 4°C).
-
bioRxiv - Cell Biology 2020Quote: ... and cell size and cell density were measured using the Multisizer 4 Coulter Counter (Beckman-Coulter, Mississauga, ON) or collected for whole cell lysis at time points indicated in the figures ...
-
bioRxiv - Biophysics 2021Quote: ... Cellular debris was removed by centrifugation at 18k rpm for 60 min at 4 °C (Beckman JA-20). The lysate was incubated with 5mL of washed and packed GST resin (GE Healthcare ...
-
bioRxiv - Biophysics 2020Quote: ... and then sonicated and ultracentrifuged (440,000 g, 35 min, 4°C; MLA80 rotor, Beckman Optima™ MAX-TL). The supernatant was applied to a Ni-NTA column (Machery-Nagel ...
-
bioRxiv - Cell Biology 2020Quote: ... pellets obtained by ultracentrifugation (100,000 x g in Ti45 Beckman Coulter rotor for 70 min. at 4 ° C) were washed and resuspended in 1.25 ml buffer [0.25 M sucrose ...
-
Targeted attenuation of elevated histone marks at SNCA alleviates α-synuclein in Parkinson’s diseasebioRxiv - Neuroscience 2020Quote: ... The samples were then centrifuged at 107,163.6 X g for 2.5 hours at 4°C in an ultracentrifuge (XPN 100, Beckman Coulter). After centrifugation ...
-
bioRxiv - Plant Biology 2020Quote: ... and 100 μg/ml cycloheximide) and centrifuged for 1.5 h at 50,000 rpm at 4 °C in a SW55 Ti rotor (Beckman). RNA labeling was performed according to Zoschke et al ...
-
bioRxiv - Zoology 2021Quote: ... then held at 4°C) at manufacturer-recommended enzyme concentrations and used AMPure XP beads (Beckman Coulter, #A63881) at a 1.5X ratio to retain only DNA from the digestion ...
-
bioRxiv - Genetics 2022Quote: ... were then spun at 19,000rpm/90 minutes/4°C using an ultracentrifuge and a SW28 hanging rota (Beckman). All supernatant was removed and each viral pellet was resuspended with 300 µl of 1% Bovine Serum Albumin (Tocris Bioscience ...
-
bioRxiv - Cell Biology 2020Quote: ... Bacteria were spun down at 6000 rpm at 4 °֯C for 30 min in JLA8.1 rotor (Beckman Coulter) in Beckman Avanti J-26S ...
-
bioRxiv - Cell Biology 2020Quote: ... and spun at 3,300 (2,647 rcf) rpm at 4 °C for 40 min using JS 5.3 rotor (Beckman Coulter) in Beckman Avanti J-26S ...
-
bioRxiv - Cell Biology 2020Quote: ... the cleared supernatant was ultracentrifuged at 47,000 g for 2 hours at 4 °C using the JA25.50 rotor (Beckman). The virus was resuspended overnight in 180 μL D10 medium at 4 °C ...
-
bioRxiv - Cell Biology 2020Quote: ... and then centrifuged (300 g for 5 min. at 4 °C) (Allegra X-30R Centrifuge, Beckman Coulter, USA) to obtain the myofiber-associated cell pellet ...
-
bioRxiv - Biochemistry 2020Quote: ... 4 °C) using a TLA-55 rotor in an Optima MAX-XP tabletop ultracentrifuge (Beckman Coulter Life Sciences). EDC (ThermoFischer Scientific ...
-
bioRxiv - Biochemistry 2021Quote: ... 2 mM Mg(OAc)2 and 150 mM KCl) and centrifuged at 116,000 xg for 5 h at 4°C in a TL100.3 rotor (Beckman). The ribosome pellet was resuspended by orbital shaking (1 h at 4°C ...
-
bioRxiv - Biochemistry 2021Quote: ... were pelleted by ultracentrifugation (80,000 rpm, 4°C, 20 min with a TLA 100.1 rotor in a Beckman Optima TLX Ultracentrifuge ...
-
bioRxiv - Biochemistry 2021Quote: ... were pelleted by ultracentrifugation (80,000 rpm, 4°C, 20 min with a TLA 100.1 rotor in a Beckman Optima TLX Ultracentrifuge; Beckman Coulter Life Sciences ...
-
bioRxiv - Cancer Biology 2020Quote: ... Cells were incubated overnight at 4°C prior to analysis on a Gallios cytometer (Beckman Coulter Life Sciences) using Kaluza 2.1 analysis software (Beckman Coulter).
-
bioRxiv - Biochemistry 2021Quote: ... and then centrifuging at 30,000 x g for 25 min at 4 °C in a JA 25.50 rotor (Beckman). GsI-IIC RT and other cellular proteins were then precipitated from the supernatant with 60% saturating ammonium sulfate ...
-
bioRxiv - Cell Biology 2021Quote: ... supernatants were spun for 70 minutes at 200,000 × g and 4°C in an XPN-80 ultracentrifuge equipped with a Type 50.4 Ti rotor (Beckman Coulter ...
-
bioRxiv - Genetics 2021Quote: ... from pooled wells) were fixed using 4% paraformaldehyde (PFA) and analyzed for GFP fluorescence by CytoFLEX (Beckman-Coulter) to determine the percentage of infected cells ...
-
bioRxiv - Cell Biology 2021Quote: ... 4 °C for 2 h in an Optima L-100XP ultracentrifuge (with SW 55 Ti rotor, Beckman Coulter). Fractionation was done manually by collecting every 200 μl volume from the top till the bottom of each centrifuge tube ...
-
bioRxiv - Microbiology 2022Quote: ... The supernatant fractions were collected and centrifuged at 75,600 x g for 90 min at 4 °C (Beckman JA25.50 rotor ...
-
bioRxiv - Molecular Biology 2022Quote: ... The elutions were combined and centrifuged at 186,000 x g at 4 °C for 1.5 h in a (TLA-120.1) rotor (Beckman Coulter). Supernatant was discarded and the pellet was resuspended in the RNC buffer at a concentration of ~200 nM ...
-
bioRxiv - Biochemistry 2022Quote: ... Membrane contamination was removed by centrifugation 100,000 x g 1.25 hours 4°C in an NVT65.2 rotor (Beckman Coulter). The clarified supernatant was concentrated to 50 µl by ultrafiltration (Sartorius Vivaspin Turbo ...
-
Dynamic states of eIF6 and SDS variants modulate interactions with uL14 of the 60S ribosomal subunitbioRxiv - Biochemistry 2022Quote: ... Gradients were centrifuged at 49,100g for 16 to 17 hrs at 4°C in an SW32Ti rotor (Beckman). Gradients were fractionated using a Brandel (UV ...