Labshake search
Citations for Diagenode :
1 - 50 of 68 citations for Streptavidin magnetic beads since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Plant Biology 2020Quote: ... magnetic beads (DiaMag protein A-coated magnetic beads: Diagenode) were incubated with each antibody overnight ...
-
bioRxiv - Genomics 2021Quote: ... Dynal Protein A magnetic beads (Diagenode) and ChIP-graded anti-myc antibody (ab9132 ...
-
bioRxiv - Microbiology 2023Quote: ... magnetic beads coated with DiaMag protein A (Diagenode), and antibodies against epitope tags (HA or MYC ...
-
bioRxiv - Genomics 2021Quote: ... After overnight incubation with DiaMag magnetic beads (Diagenode, Inc.) and antibodies ...
-
bioRxiv - Cancer Biology 2024Quote: Immunoprecipitation: Protein A/G-coated magnetic beads (protein A-coated beads (Diagenode, # C03010020-150) for rabbit antibody ...
-
bioRxiv - Developmental Biology 2022Quote: ... Sheared chromatin was thereafter immunoprecipitated with Protein A-coated magnetic beads (Diagenode) preincubated with 4.5 μg/IP MED1 antibody (Bethyl A300-793A ...
-
bioRxiv - Molecular Biology 2024Quote: ... The sheared chromatin was immunoprecipitated using the DiaMag protein A-coated magnetic beads (Diagenode) and 2 µg of anti-HvHsfA6a antibodies ...
-
bioRxiv - Cancer Biology 2024Quote: ... DNA was precipitated and purified with magnetic beads with the IPure v2 kit (Diagenode). Before sequencing ...
-
bioRxiv - Cell Biology 2023Quote: ... were used per ChIP and were bound to DiaMag protein G-coated magnetic beads (Diagenode, C03010021) overnight at 4°C with gentle rotation ...
-
bioRxiv - Cancer Biology 2021Quote: ... The DNA-protein-antibody complexes were captured by DiaMag protein A-coated magnetic beads (Diagenode; Cat#: C03010020) by incubating at 4 °C for 2 hours ...
-
bioRxiv - Cancer Biology 2021Quote: ... The DNA-protein-antibody complexes were captured by DiaMag protein A-coated magnetic beads (Diagenode; Cat#: C03010020) by incubating at 4 °C for 2 hours ...
-
bioRxiv - Microbiology 2023Quote: ... the different antibodies were previously incubated at 4°C with protein G-coated magnetic beads (DiaMag, Diagenode), protease inhibitor cocktail and 0.1% BSA ...
-
bioRxiv - Cell Biology 2024Quote: ... The DNA-protein-antibody complexes were captured by DiaMag protein A-coated magnetic beads (Diagenode; Cat#: C03010020) by incubating at 4°C for 2 h ...
-
bioRxiv - Neuroscience 2022Quote: ... Chromatin-protein complexes were immunoprecipitated with protein A/G magnetic beads and washed sequentially according to the manufacturer (Diagenode, C01010055). DNA fragments were then purified using IPure beads v2 (Diagenode ...
-
bioRxiv - Developmental Biology 2022Quote: ... Samples were centrifuged at 14000rpm for 15mins at 4 oC and precleared using with 4ml of Magnetic A Beads (Diagenode) at 4 oC for 1 hour ...
-
bioRxiv - Microbiology 2023Quote: ... 10 μg total RNA was incubated overnight at 4 °C with Dynabeads™ Protein G magnetic beads pre-bound with anti-Ψ (Diagenode) according to manufacturer’s instructions ...
-
bioRxiv - Neuroscience 2021Quote: ... equal volume of sheared chromatin was incubated overnight with 3 μg of antibody in iC1b buffer with protease inhibitors and BSA and washed DiaMag Protein A-coated magnetic beads (Diagenode Cat# C03010020-220) on a tube rotator at 4°C overnight ...
-
bioRxiv - Cancer Biology 2022Quote: ... RNA extraction beads (Diagenode) in a Diagenode Bioruptor Plus sonicator ...
-
bioRxiv - Biochemistry 2023Quote: ... Unblocked protein A beads (Diagenode, C03020003) were used to pulldown the antibody-protein complexes ...
-
bioRxiv - Molecular Biology 2021Quote: ... with 437.5 mg sonication beads (Diagenode, C03070001) for 6 cycles (1 min on/1 min off ...
-
bioRxiv - Synthetic Biology 2021Quote: ... with 437.5 mg sonication beads (Diagenode, C03070001) for 6 cycles on a Bioruptor Pico sonicator ...
-
bioRxiv - Neuroscience 2023Quote: ... and protein extraction beads (Diagenode, NJ, USA) according to the manufacturer instructions ...
-
bioRxiv - Cancer Biology 2024Quote: ... protein G-coated beads (Diagenode, # C03010021-150) for mouse antibody ...
-
bioRxiv - Neuroscience 2022Quote: ... A modified protocol for on-beads digest (sonication for 10*30s in a Bioruptor sonicator in presence of 50 mg Protein Extraction beads, C20000021, Diagenode) was used for tissue samples followed by a 3.5h digestion step ...
-
bioRxiv - Cancer Biology 2022Quote: ... homogenization was performed using protein extraction beads (Diagenode) and sonication in the lysis buffer followed by centrifugation to remove solid remains (Diagenode Bioruptor Plus sonicator manufacturer’s protocol for protein extraction from tissue fragments) ...
-
bioRxiv - Genomics 2024Quote: ... with 650 mg of beads (Diagenode Cat #C03070001). After sonication ...
-
bioRxiv - Molecular Biology 2024Quote: ... Magnetic immunoprecipitation and tagmentation were realized on an automated pipetting system (Diagenode SX-8G IP-Star Compact) The optimal number of amplification cycles determination step is also included in the Diagenode protocol.
-
bioRxiv - Neuroscience 2020Quote: ... using a glass bead sonicator (Diagenode, Denville, NJ, USA). Tubes were centrifuged and the protein extract was aliquoted for multiplex analysis ...
-
bioRxiv - Molecular Biology 2023Quote: ... using 350 mg/mL of sonication beads (Diagenode, C03070001) for 40 cycles of 30 s ON ...
-
bioRxiv - Cancer Biology 2023Quote: ... incubated in RNA Extracol with RNA extraction beads (Diagenode), sonicated using Bioruptor Plus (Diagenode) ...
-
bioRxiv - Neuroscience 2023Quote: ... in presence of 50 mg Protein Extraction beads (C20000021, Diagenode); samples were trypsin digested for 2 h 30 min ...
-
bioRxiv - Cell Biology 2024Quote: ... and samples were sonicated using sonication beads (Diagenode; Cat #C01020031) and the Bioruptor Pico Sonicator (Diagenode ...
-
bioRxiv - Molecular Biology 2024Quote: ... in the presence of sonication beads (Diagenode, Cat. No. C03070001). Every 10 cycles tubes were vortexed.
-
bioRxiv - Neuroscience 2022Quote: ... DNA fragments were then purified using IPure beads v2 (Diagenode, C01010055). Input (non-immunoprecipitated chromatin ...
-
bioRxiv - Cell Biology 2021Quote: ... and samples were purified using the iPure v2 bead kit (Diagenode). Libraries were constructed using the MicroPlex Library Preparation Kit v2 (Diagenode ...
-
bioRxiv - Immunology 2024Quote: ... Beads were blocked with 1 µL of antibody (α-H3K27ac, Diagenode, C15410196 ...
-
bioRxiv - Genetics 2023Quote: ... coupled to 30µL beads was added to 400µL soluble chromatin (Diagenode H3K9me3 antibody was used in Figure 2E only ...
-
bioRxiv - Neuroscience 2024Quote: ... 50mg of Diagenode Protein Extraction Beads (Diagenode C20000021, Denville, NJ, USA) were loaded into 0.5 mL Axygen Maxymum Recovery tubes (Axygen #PCR-05-L-C ...
-
bioRxiv - Genomics 2020Quote: ... The sheared chromatin derived from one million cells was subjected to magnetic immunoprecipitation and tagmentation using an SX-8G IP-STAR® Compact Automated System (Diagenode) with the anti-GATA6 antibody (D61E4 ...
-
bioRxiv - Microbiology 2020Quote: ... Beads were discarded and 1 µg of anti-CTCF antibody (Diagenode #C15410210) or isotype matched negative control were added to the chromatin ...
-
bioRxiv - Cancer Biology 2020Quote: ... followed by immunoprecipation of immunocomplexes with protein-A agarose beads (Diagenode; C03020002) previously blocked with 0.5% BSA for 1 hr at 4°C ...
-
bioRxiv - Plant Biology 2022Quote: ... The bead-bound chromatin was purified by using iPure kit v2 (Diagenode) following the manual and quantified using QubitTM dsDNA HS Assay kit (Invitrogen) ...
-
bioRxiv - Molecular Biology 2023Quote: ... Antibody-bound chromatin was then coupled to protein A beads (Diagenode, C03020002) for three hours at 4° C ...
-
bioRxiv - Genetics 2024Quote: ... and beads were resuspended in 50uL loaded pA-Tn5 adapter complex (Diagenode C01070001-T30 ...
-
bioRxiv - Cancer Biology 2024Quote: ... and 150 mM NaCl) prior to sonication using beads in a Bioruptor (Diagenode) for 20 cycles of 15 seconds on and 30 seconds off ...
-
bioRxiv - Cancer Biology 2020Quote: ... The chromatin was precleared with beads and immunoprecipitated with Tal1antibody (Diagenode, cat no: C15200012) overnight at 4°C ...
-
bioRxiv - Immunology 2020Quote: 1.5 ml Bioruptor Microtubes were filled with 250 mg of Protein Extraction Beads (Diagenode) and filled with RIPA buffer (supplemented with protease and phosphatase inhibitors) ...
-
bioRxiv - Molecular Biology 2022Quote: ... Chromatin was sheared in Bioruptor® Pico 15 mL tubes with 300 µL beads (Diagenode C30010017) by 25 cycles of 30 sec on and 30 sec off using a Bioruptor® (Diagenode B01060010) ...
-
bioRxiv - Cancer Biology 2020Quote: ... SP3 beads (36, 37) were added and the tissues were sonicated in a Bioruptor Pico (Diagenode) for 10 cycles (30 seconds ON ...
-
bioRxiv - Immunology 2024Quote: ... Beads were blocked with 1 µL of antibody (α-H3K27ac, Diagenode, C15410196; α-H3K4me3, Diagenode, C15410003) in antibody binding buffer for 3-4h at 4°C with rotation ...