Labshake search
Citations for Diagenode :
101 - 150 of 506 citations for Glutathione Colorimetric Detection Kit 200 High Cuvettes since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Plant Biology 2021Quote: ... Extracted chromatin was sonicated to ∼200-500 bp at 4℃ using a Bioruptor (Diagenode). For immunoprecipitation ...
-
bioRxiv - Developmental Biology 2019Quote: ... Chromatin was sheared to average size of 500bp using a Bioruptor (Diagenode UCD-200). FOXP1 (Abcam # ab16645) ...
-
bioRxiv - Neuroscience 2021Quote: ... sonicated for 3×5 minutes in a 4°C Bioruptor ultrasonicator (UCD-200, Diagenode), vortexed ...
-
bioRxiv - Genetics 2022Quote: ... per 10 ml of solution and lysed by sonication in Bioruptor (UCD-200, Diagenode) with the following settings ...
-
bioRxiv - Cancer Biology 2023Quote: ... The tissues were homogenized using a Bioruptor standard water bath sonicator (Diagenode, UCD-200) with the following settings ...
-
bioRxiv - Microbiology 2024Quote: ... The DNA was sheared into ∼200 bp fragments by ultra-sonication (Bioruptor Plus Diagenode). Fragmented DNA samples were prepared for Illumina sequencing using the NEBNext Ultra I DNA Library Prep Kit for Illumina according to manufacturer’s instructions with the following modifications ...
-
bioRxiv - Genomics 2020Quote: ... followed by sonication at high power for 10 cycles of 30s ON/OFF (Bioruptor Plus; Diagenode). Lysates were clarified by centrifugation at 10,000g for 15min ...
-
bioRxiv - Genomics 2019Quote: ... 20 µg high molecular weight genomic DNA was sheared using the Megaruptor instrument (Diagenode, Liege, Belgium) to 40kb and this was used as input into the SMRTbell library preparation ...
-
bioRxiv - Cell Biology 2022Quote: ... The lysates were sonicated (30 s/30 s, 10 cycles, high performance) by Bioruptor (Diagenode; B01020001), followed by centrifugation at 21000xg for 20 min at 20°C ...
-
bioRxiv - Molecular Biology 2023Quote: ... for 20 cycles (30 sec on/30 sec off, high-intensity) in a Bioruptor NextGen (Diagenode). Chromatin and DNA samples were processed in DNA LoBind tubes from here on (Eppendorf #2023-04-28 ...
-
bioRxiv - Genetics 2019Quote: ... and re-suspended in 200 μl of Tris–EDTA and sonicated with a Bioruptor (Diagenode) to obtain 100–500 bp long fragments ...
-
bioRxiv - Cancer Biology 2020Quote: ... Sonication of crosslinked chromatin was performed using a Bioruptor® UCD-200™Sonicator (Diagenode) with optimized cycles for each cell type ...
-
bioRxiv - Genetics 2020Quote: ... Sonication of the samples 200-700 bps smear was accomplished using a Bioruptor sonicator (Diagenode), for a total of 45 minutes sonication at full power and sonication cycles of 30”ON/30”OFF ...
-
bioRxiv - Plant Biology 2020Quote: ... Cross-linked chromatin was sonicated using a water bath Bioruptor UCD-200 (Diagenode, Liège, Belgium) (15s on/15s off pulses ...
-
bioRxiv - Evolutionary Biology 2019Quote: ... 200 ng of gDNA was briefly sonicated using a Bioruptor sonication device (Diagenode, Liege, Belgium), end-repaired and size-selected on beads to retain fragments of size around 550 bp ...
-
bioRxiv - Genomics 2021Quote: ... Samples were sonicated to an average size of 200 bp using a Bioruptor Pico (Diagenode) and NEBNext Multiplex reagents and sequencing adapters were used to prepare sequencing libraries following the Illumina NEBNext DNA library prep kit instructions (New England Biolabs) ...
-
bioRxiv - Biochemistry 2022Quote: ... and subsequently disrupted by 2 × 20” high intensity sonication cycles at 4°C in a BioRuptor (Diagenode). Protein concentration was determined using the Micro BCA™ protein assay kit according to manufacturer’s instructions (Thermo Scientific) ...
-
bioRxiv - Developmental Biology 2019Quote: ... DNA was crosslinked in formaldehyde and sonicated in a Bioruptor for 15 minutes at high power (Diagenode). Cells were resuspended in a total volume of 250 ml of Buffer A and Buffer B mix (half of the recommended volume for 0.5×106cells) ...
-
bioRxiv - Molecular Biology 2021Quote: ... then the sample was sonicated at a high intensity (3 × 5 min) using a Bioruptor sonicator (Diagenode). To obtain organoid-MPF cocultures ...
-
bioRxiv - Molecular Biology 2023Quote: ... and then sonicated for 5 min at high setting with 30sON/30sOFF in a Bioruptor sonicator (Diagenode) and centrifuged for 5 min at 19000g at 4°C ...
-
bioRxiv - Molecular Biology 2024Quote: ... The DNA was sheared by sonication (4x 7 cycles, 30s on / 30s off, power high; Bioruptor, Diagenode) at 4°C and lysates cleared by centrifugation at 16,100 x g at 4°C for 15 min ...
-
bioRxiv - Microbiology 2019Quote: ... tubes from the first step were sonicated in an ultrasonic water bath (Bioruptor UCD-200, Diagenode) for 15 cycles of 30 seconds on and 30 seconds off at full power ...
-
bioRxiv - Cancer Biology 2022Quote: ... 1% SDS and sonicated to obtain approximately 200–500 bp chromatin fragments using a Bioruptor (Diagenode). Chromatin fragments were precleared with salmon sperm DNA (Trevigen ...
-
bioRxiv - Developmental Biology 2019Quote: ... DNA was sheared into fragments ranging from 200 bp to 1000 bp using a sonicator (Diagenode Bioruptor Water Bath Sonicator ...
-
bioRxiv - Immunology 2019Quote: ... followed by sonication to fragment chromatin to an average size of 200–500bp (Bioruptor NGS, Diagenode). Protein-DNA complexes were immuno-precipitated using 3μg of H3K27ac antibody from the same lot for all ChIP experiments (Catalogue #39133 ...
-
bioRxiv - Molecular Biology 2021Quote: ... Lysates were sonicated on ice to yield 200-600 bp DNA fragments using a Bioruptor (Diagenode).
-
Rbx1 Cullin-Ring ligase E3 and Ube2m neddylation E2 differentially governs the fitness of Treg cellsbioRxiv - Immunology 2020Quote: ... and subsequently lysed by 5min boiling at 95°C and sonication (Bioruptor, model UCD-200, Diagenode) for 15min ...
-
bioRxiv - Cancer Biology 2022Quote: ... purified gDNA from M.CviPI-treated cells was fragmented by sonication with a UCD-200 Bioruptor (Diagenode) at high level for 25 sec in 100 μl molecular-grade H2O ...
-
bioRxiv - Cell Biology 2024Quote: ... and chromatin was sheared to a range of 200-500bp by using a Bioruptor instrument (Diagenode) with the following settings ...
-
bioRxiv - Genomics 2019Quote: ... High molecular weight DNA was sheared to ∼8kb using Covaris g-tubesTM (Woburn, MA) or a Megaruptor (Diagenode), followed by end-repair using the NEBNext EndRepair Module (New England Biolabs) ...
-
bioRxiv - Immunology 2020Quote: ... and sonicated for 7.5 min (1.5 mL tubes, high power, 30 s on/off cycle, Bioruptor plus, Diagenode). Lysates (20–30 μL ...
-
bioRxiv - Genomics 2023Quote: ... and sonicated for 6 cycles of 30s ON/30s OFF on high power using the Bioruptor Plus (Diagenode). Insoluble material was removed by centrifugation at >16,000g for 10 min at 4°C ...
-
bioRxiv - Cell Biology 2021Quote: ... Cells were sonicated for 30 cycles at high setting (30s on, 30s off) using a Bioruptor Pico sonicator (Diagenode) and centrifuged at 13000 rpm for 10 min ...
-
bioRxiv - Microbiology 2020Quote: ... and were sonicated for 20 cycles of 30 sec ON/30 sec OFF (setting high, BioruptorTM Next Gen, Diagenode) to shear DNA to fragments of 100-600 bps ...
-
bioRxiv - Molecular Biology 2019Quote: ... Samples were sonicated 12 times (30 sec on, 30 sec off) at the high intensity in a Bioruptor (Diagenode) device ...
-
bioRxiv - Molecular Biology 2023Quote: ... High Molecular Weight Genomic DNA (5 µg) was sheared with the 40 kb program using a Diagenode Megaruptor (Diagenode) to generate DNA fragments of approximately 30 kb ...
-
bioRxiv - Molecular Biology 2024Quote: ... Cells were sonicated (settings: 3 – 4 x 30 sec on /30 sec off, 4°C, power high; Bioruptor, Diagenode) and lysates were cleared by centrifugation at 16,000 x g at 4°C for 15 min ...
-
bioRxiv - Cancer Biology 2024Quote: ... Chromatin samples were sheared using a sonicator set at “high” with 30 s pulse on/off cycles (Diagenode Bioruptor). Pulse cycles were optimised (9-15 cycles ...
-
bioRxiv - Genetics 2024Quote: ... Cells were lysed by sonication for 15 cycles (high, 30 seconds on, 30 seconds off) using Bioruptor Plus (Diagenode). After a 15-minute incubation on ice and centrifugation (21,000 ✕ g ...
-
bioRxiv - Cancer Biology 2019Quote: ... and subsequently lysed by boiling for 5 min at 95°Cand sonication (Bioruptor, model ACD-200, Diagenode) for 15 min at level 5 (30 sec ON ...
-
bioRxiv - Developmental Biology 2021Quote: 5×105 fixed nuclei were sonicated to a 200-500bp length with the Bioruptor Pico sonicator (Diagenode). H3K27Ac ChIP was (Diagenode C15410174 ...
-
bioRxiv - Plant Biology 2021Quote: ... anti-GT1 (1:75) and anti-YSPTSPS repeat S2Pho (RNA Pol II, B1 subunit; 1:200, Diagenode). The samples were washed for 8h at 4°C with gentle agitation with PBS (0.2% v/v Tween-20 ...
-
bioRxiv - Developmental Biology 2019Quote: ... the amplified cDNA (2 μg per sample) was fragmented to 200 bp using a Bioruptor Sonicator (Diagenode), and barcode ligation and end repair were performed using the Ovation Rapid DR Library System (NuGEN) ...
-
bioRxiv - Plant Biology 2019Quote: ... The extracts were sonicated in 15 ml tubes in an ice bath using Bioruptor UCD-200 (Diagenode) on high setting ...
-
bioRxiv - Molecular Biology 2021Quote: ... DNA from this lysate was sheared to 300 bp fragments using a BioRuptor UCD-200 sonicator (Diagenode). Cell debris were removed by high-speed centrifugation and DNA from the supernatant was isolated by ethanol precipitation and resuspension in TE buffer ...
-
bioRxiv - Plant Biology 2022Quote: ... Cells were ruptured by 5 × 15 sec sonication in an ice bath in Bioruptor UCD-200 (Diagenode) at medium intensity with 2 min breaks on ice ...
-
bioRxiv - Plant Biology 2022Quote: ... The suspensions were sonicated for 20min with the Bioruptor® Sonication System (Diagenode, catalog No. UCD-200) using a 30sec high and 30sec break setting ...
-
bioRxiv - Molecular Biology 2023Quote: ... Chromatin from 10 million cells was sonicated to between 200-600 bp using a Bioruptor Plus (Diagenode). 100µL of Dynabeads Protein G (Invitrogen ...
-
bioRxiv - Genomics 2023Quote: ... Lysates were moved to 15ml polystyrene conical tubes (Falcon) and sonicated in a Biorupter UCD-200 (Diagenode) on high for 30 seconds on and 30 seconds off for 4 sets of 5 cycles ...
-
bioRxiv - Cancer Biology 2023Quote: ... and samples were sonicated to an average DNA length of 200–400 bp with a bioruptor (Diagenode). After sonication ...