Labshake search
Citations for Harvard Apparatus :
1 - 50 of 113 citations for Mouse DTW Domain Containing Protein 2 DTWD2 ELISA Kit since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2023Quote: Mice were sacrificed 24 or 72 h after tMCAO and brains were removed and cut into three 2 mm-thick slices (mouse brain slice matrix; Harvard Apparatus). For determination of infarct volume ...
-
bioRxiv - Neuroscience 2020Quote: ... brains were quickly removed and cut into four 2-mm thick coronal sections using a mouse brain slice matrix (Harvard Apparatus, Spain). Sections were stained for 15 min at room temperature with 2% 2,3,5-triphenyltetrazolium chloride (TTC ...
-
bioRxiv - Biochemistry 2019Quote: ... and brains were quickly removed and cut into 2-mm thick coronal sections using a mouse brain slice matrix (Harvard Apparatus, USA). The brain sections were then stained with 2% 2 ...
-
bioRxiv - Cell Biology 2019Quote: ... together with the trachea and the heart were excised from the thorax in one piece and transferred to a 37 °C temperature-equilibrated housing chamber of the perfused mouse lung model (IPL-2, Hugo Sachs Elektronik/Harvard Apparatus (March-Hugstetten, Germany)) ...
-
bioRxiv - Neuroscience 2019Quote: ... and anaesthetised with isoflurane (2% for induction, 1 - 2% for surgery, 1% for electrophysiology in 1.2% O2, Harvard Apparatus, UK). To maintain clear airways and avoid tracheal secretions ...
-
bioRxiv - Neuroscience 2019Quote: ... and anaesthetised with isoflurane (2% for induction, 1 – 2% for surgery, 1% for electrophysiology in 1.2% O2, Harvard Apparatus, UK). A vaporizer controlled the isoflurane concentration and a scavenger retrieved superfluous anaesthetic ...
-
bioRxiv - Bioengineering 2020Quote: ... This mixture was then transferred into a 2-mm gap length 96-well electroporation plate (HT-P96-2, Harvard Apparatus) and electroporated in a Gene Pulser XCell (Biorad ...
-
bioRxiv - Molecular Biology 2020Quote: ... in mice anesthetized with isoflurane (1.5 – 2% for induction and 1 – 2 % for maintenance of anesthesia; Isotec 100 Series Isoflurane Vaporizer; Harvard Apparatus). Mouse core body temperature (monitored by a rectal probe) ...
-
bioRxiv - Molecular Biology 2022Quote: ... in mice anesthetized with isoflurane (2% for induction and 2 % for maintenance of anesthesia; Isotec 100 Series Isoflurane Vaporizer; Harvard Apparatus). AF was defined as the occurrence of rapid and fragmented atrial electrograms with irregular AV-nodal conduction and ventricular rhythm for at least 1 second ...
-
bioRxiv - Immunology 2022Quote: ... sutured and attached to a MiniVent mouse ventilator (Harvard Apparatus). Mice were ventilated with a tidal volume of 10 μl of compressed air (21% O2 ...
-
bioRxiv - Molecular Biology 2023Quote: ... intubated and ventilated with a mouse ventilator (Harvard Apparatus, MA). Following sternotomy ...
-
bioRxiv - Neuroscience 2023Quote: ... the mouse was moved to a heat pad (Harvard Apparatus) on the stereotaxic frame ...
-
bioRxiv - Animal Behavior and Cognition 2019Quote: ... and the home cage containing the pups was placed in a warming box (Harvard Apparatus) set at 33° C for at least 10 minutes prior to the start of recording ...
-
bioRxiv - Molecular Biology 2020Quote: ... 2-5 MΩ borosilicate glass electrodes (GC150-10F, Harvard Apparatus) filled with aCSF were placed into the stratum radiatum of a GFP positive region of CA1 and a bipolar stimulating electrode (CBAPB50 ...
-
bioRxiv - Neuroscience 2020Quote: ... mice were anesthetized with isoflurane (2% in oxygen, Harvard Apparatus) and positioned onto a small animal physiological monitoring System (ST2 75-1500 ...
-
bioRxiv - Cell Biology 2021Quote: ... Morpholinos were loaded in a pulled borosilicate glass filament containing capillary (GC100F-15; Harvard Apparatus, Holliston). Injections of typically 1nL were performed at 1 cell stage embryos ...
-
bioRxiv - Neuroscience 2022Quote: ... DA neurons containing red retrobeads were recorded using borosilicate pipettes (3-4 MOhm, GC150TF, Harvard Apparatus) filled with internal solution (135 mM K-gluconate ...
-
bioRxiv - Synthetic Biology 2022Quote: ... all protein digests were desalted using C18 microspin columns (Harvard Apparatus, Holliston, USA) according to the manufacturer’s instructions.
-
bioRxiv - Microbiology 2024Quote: ... all protein digests were desalted using C18 microspin columns (Harvard Apparatus, Holliston, USA) according to the manufacturer’s instructions.
-
bioRxiv - Neuroscience 2022Quote: ... The mouse was placed on Harvard Small Animal Physiological Monitoring System (Harvard Apparatus) and was maintained on a body temperature at 370C and oxygen saturation > 90% in room air ...
-
bioRxiv - Bioengineering 2021Quote: ... Thy1-EGFP mice were anesthetized with isoflurane (2% in oxygen, Harvard Apparatus) while for functional astrocyte imaging mice were kept under low anesthesia (isoflurane 1-1.5% in oxygen) ...
-
bioRxiv - Physiology 2022Quote: ... Borosilicate glass pipettes (resistance: 2-5 MΩ.; GC150F-7.5, Harvard Apparatus, USA) were prepared with a P-97 horizontal micropipette puller (Sutter Instrument ...
-
bioRxiv - Neuroscience 2023Quote: ... typically using 30–40 nA currents (Neurophore BH-2 System, Harvard Apparatus). The duration of the drug ejection usually lasted 8–10 min and the recording protocols were extended until the effect of the drug had disappeared (60 to 90 minutes approx.) ...
-
bioRxiv - Neuroscience 2020Quote: ... Two millimetre thick tissue sections containing the LC and hippocampus were obtained using a brain matrix (Harvard Apparatus, #726233). A tissue punch was used to extract the LC and hippocampus regions which were snap frozen using liquid nitrogen until processed further according to manufacturer’s protocols.
-
bioRxiv - Neuroscience 2022Quote: Pipettes were pulled from standard-walled filament-containing borosilicate glass capillaries (Harvard Apparatus, 1.5 mm OD, 0.85 mm ID) using a vertical micropipette puller (PC-10 or PC-100 ...
-
bioRxiv - Immunology 2021Quote: ... the mouse head was shaved and held in a stereotactic skull holder (Harvard Apparatus). Calvarial bone marrow was exposed ...
-
bioRxiv - Biophysics 2022Quote: ... Currents were recorded using borosilicate microelectrodes (Harvard Apparatus, resistance of 0.3-2 MΩ), backfilled with 3 M KCl ...
-
bioRxiv - Biochemistry 2019Quote: ... for 2 days on 12 mm cover glass (64-0712, Harvard Apparatus, USA) coated with poly-D-lysine (ICN15017550) ...
-
bioRxiv - Microbiology 2022Quote: ... transferred to a disposable 2 mm gap cuvette (BTX Harvard Apparatus, Holliston, MA), and transfected using an Amaxa Biosystems Nucleofector II (Lonza ...
-
bioRxiv - Cell Biology 2022Quote: ... The chamber was mounted in a temperature-controlled microincubator (PDMI-2, Harvard Apparatus) on a TE2000 inverted microscope running Elements™ acquisition and analysis package (Nikon Inc ...
-
bioRxiv - Neuroscience 2023Quote: Fear conditioning tests were performed for 2 days (Panlab Harvard Apparatus, Barcelona, Spain). On the first day ...
-
bioRxiv - Neuroscience 2022Quote: ... The protein samples were loaded into in-house prepared gold-coated capillary needles (Harvard Apparatus) and were injected directly to the mass spectrometer ...
-
bioRxiv - Physiology 2023Quote: ... mice were given a constant rate infusion of dobutamine (0.625 mg/ml in normal saline containing 5% dextrose) via the tail vein using an infusion syringe pump (Harvard Apparatus). The first infusion was at the low dose of 10 μg/kg/min ...
-
bioRxiv - Pharmacology and Toxicology 2019Quote: ... and recirculated at 1.5-2 ml/min (Reglo peristaltic pump, Harvard Apparatus, 73-2449) at RT ...
-
bioRxiv - Neuroscience 2024Quote: ... Open pipette resistances were 2-5 MΩ (borosilicate glass pipette; Harvard Apparatus #30-0057). Recordings were performed using a Multiclamp 700B amplifier (Molecular Devices) ...
-
bioRxiv - Physiology 2020Quote: ... Protein digests were separated from the beads and purified using a C18 spin column (Harvard Apparatus). The peptides were vacuum dried using a speedvac.
-
bioRxiv - Biophysics 2019Quote: ... The protein solution was delivered with the aid of a syringe pump (Harvard Apparatus, Holliston, MA) at 0.5 µL/min to the ion source of an LTQ mass spectrometer (Thermo Fisher Scientific ...
-
bioRxiv - Neuroscience 2022Quote: ... Protein digests were separated from the beads and purified using a C18 spin column (Harvard Apparatus). The peptides were vacuum dried using a speedvac ...
-
bioRxiv - Cell Biology 2023Quote: ... a 28-gauge insulin syringe needle was connected via polyethylene tubing (PE-10) to a syringe (containing glucose solution) placed on an infusion pump (Harvard Apparatus). At the start of the infusion ...
-
bioRxiv - Biophysics 2023Quote: ... the mouse body temperature was maintained at 37.5 °C with a temperature-controlled blanket (Harvard Apparatus) and the eyes were kept lubricated with eye ointment ...
-
bioRxiv - Neuroscience 2020Quote: ... mice were anesthetized with isoflurane (1-2%) and kept on a heating blanket (Harvard Apparatus). Lidocaine was used as a local analgesic and injected under the scalp at the start of surgery ...
-
bioRxiv - Neuroscience 2020Quote: ... a 2 mm section of split PE-20 polyethylene tubing (Harvard apparatus, Les Ulis, France) was placed around the right common branch of sciatic nerve in the cuff mice group ...
-
bioRxiv - Microbiology 2021Quote: ... 2 mM EGTA and 5 mM MgCl2) using a BTX ECM 630 machine (Harvard Apparatus). Electroporation was performed in a 2 mm cuvette at 1.100 V ...
-
bioRxiv - Neuroscience 2023Quote: ... point style 2) was placed into a pump (Harvard Apparatus Pump 11 Elite, Holliston, MA) and then connected to P50 tubing and a guide cannula (Plastics One ...
-
bioRxiv - Biochemistry 2019Quote: ... mBMDCs were plated 1.35×106 per well of a 12 well plate containing a single 18 mm round cover glass (64-0714, Harvard Apparatus, USA) coated with poly-D-lysine ...
-
Dual RNA-seq identifies proteins and pathways modulated during Clostridioides difficile colonisationbioRxiv - Microbiology 2023Quote: The Snapwell inserts containing the polarised cell layers were placed between the two half chambers of the VDC (Harvard Apparatus, Cambridge, UK) and sealed with the provided clamps ...
-
bioRxiv - Microbiology 2019Quote: The Snapwell inserts containing the polarized cell layer were placed between the two half chambers of the vertical diffusion chamber (Harvard Apparatus, Cambridge, UK) and sealed with the provided clamps ...
-
bioRxiv - Neuroscience 2020Quote: ... Agar slices containing ventral forebrain tissue were placed onto a positive genepaddles electrode (5×7mm; Harvard Apparatus Inc #45-0123; Holliston, MA, USA) from a BTX ECM 830 squarewave electroporation system under a stereo microscope ...
-
bioRxiv - Neuroscience 2022Quote: Mice were anesthetized with isoflurane (2%) and placed into a stereotaxic frame (Harvard Apparatus, Holliston, MA). Before the first incision the analgesic Buprenorphine (0.1 mg/kg ...
-
bioRxiv - Neuroscience 2022Quote: ... mechanically ventilated (2-4 mL tidal volume; VentElite Small Animal Ventilator, Harvard Apparatus, Holliston, MA, USA), and bilaterally vagotomized to prevent mechanosensory feedback from ventilation ...