Labshake search
Citations for Harvard Apparatus :
201 - 250 of 273 citations for 6H Pyrido 4 3 b carbazole 9 methoxy 5 6 11 trimethyl since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2022Quote: Patch pipettes of 4-6 MΩ resistance were pulled from standard-wall borosilicate capillaries (G150F-4, 1.5 mm outer diameter, 0.86 inner diameter, Harvard Apparatus) with a P-1000 electrode puller (Sutter Instruments) ...
-
bioRxiv - Bioengineering 2023Quote: ... The cells were loaded into a 20 ml syringe and injected into the device at a flow rate of 2 ml/min for low-speed mode and 3 ml/min for high-speed mode using a syringe pump (PHD ULTRA Syringe Pumps, Harvard Apparatus, USA). To implement the recirculation strategy ...
-
bioRxiv - Neuroscience 2024Quote: ... EVs were delivered in multiple microinjections over 3 minutes using air pressure from a PLI-100A Pico-Injector (Harvard Apparatus, Cambridge, UK), and were allowed to diffuse during 4 minutes before the needle was withdrawn ...
-
bioRxiv - Neuroscience 2020Quote: ... 47.5 % O2 (0.6 l/ min) and 47.5 % N2O (0.4 l/ min) and maintained with 2 % isoflurane (Harvard Apparatus anesthetic vaporizer ...
-
bioRxiv - Neuroscience 2023Quote: ... CSF was sampled at 5 min intervals from cisterna magna with a glass capillary (30-0067, Harvard Apparatus pulled by a Brown Micropipette puller ...
-
bioRxiv - Neuroscience 2023Quote: ... CSF was sampled from cisterna magna at 5⍰min intervals with a glass capillary (30–0067, Harvard Apparatus pulled by a Brown Micropipette puller ...
-
bioRxiv - Microbiology 2020Quote: ... ~2 × 107 extracellular parasites were resuspended in 370 μL cytomix buffer were mixed with ~30 μL purified plasmid or amplicon DNA in a 4-mm gap BTX cuvette and electroporated using a BTX ECM 830 electroporator (Harvard Apparatus) using the following parameters ...
-
bioRxiv - Neuroscience 2022Quote: ... Patch recording electrodes (4-8 MΩ resistance) were pulled using a PC-10 puller (Narishige) from borosilicate glass capillaries (GC150F-10, Harvard Apparatus) and filled with a filtered voltage clamp intracellular solution containing (in mM) ...
-
bioRxiv - Neuroscience 2021Quote: ... Patch electrodes (4-7 MΩ resistance) were pulled using a PC-10 puller (Narishige) from borosilicate glass capillaries (GC150F10, Harvard Apparatus). Slices were transferred to a submerged recording chamber and continuously perfused with oxygenated ACSF (3 mL/min ...
-
bioRxiv - Neuroscience 2022Quote: ... a previously-prepared coverslip consisting of a 34 mm diameter round coverglass affixed beneath a 4 mm diameter round coverglass (Harvard Apparatus UK ...
-
bioRxiv - Neuroscience 2022Quote: We glued a pollen granule sold as nutritional supplement (Morga Bluetenpollen, Morga AG) to a 2-mm borosilicate glass tube (TG200-4, Harvard Apparatus) with Super RTV Silicone Transparent (Wuerth) ...
-
bioRxiv - Microbiology 2023Quote: ... ∼2 × 107 extracellular parasites were resuspended in 370 μL cytomix buffer were mixed with ∼30 μL purified plasmid or amplicon DNA in a 4-mm gap BTX cuvette and electroporated using a BTX ECM 830 electroporator (Harvard Apparatus) using the following parameters ...
-
bioRxiv - Neuroscience 2020Quote: ... Forceps-type electrodes (Nepagene) with 5 mm pads were used for electroporation using the ECM830 electroporation system (Harvard Apparatus). Embryos were collected and fixed at E15.5 ...
-
Biochemical alterations precede neurobehavioral deficits in a novel mouse model of Friedreich ataxiabioRxiv - Biochemistry 2021Quote: ... a mouse was placed in the center of the field and its movements were recorded during 5 min using Smart Video Tracking software (v2.5.21, Panlab Harvard Apparatus). The measured parameters were total distance travelled ...
-
bioRxiv - Neuroscience 2022Quote: ... -0.5 / DV: -4.8 (angled at 4.5° towards the midline) with a 28G cannula connected to a pump (Harvard Apparatus). Glass pipette or cannula was retracted after waiting for 10 minutes following the injection.
-
bioRxiv - Biophysics 2019Quote: ... followed by laser usage (5 sec) and 10 min recordings using the Small Animal Physiological Monitoring system (Harvard Apparatus). ECG signal was obtained with three limb leads ...
-
bioRxiv - Cell Biology 2023Quote: ... samples were acidified with 5% TFA and peptides were purified using C18 reverse-phase spin columns (Macrospin, Harvard Apparatus) according to the manufacturer’s instructions ...
-
bioRxiv - Neuroscience 2022Quote: ... five 40-V pulses of 50-ms duration at 1-s intervals were delivered across the embryonic head using 3-mm-diameter electrodes (Harvard apparatus, cat# 45-0487) connected to a square wave electroporator (Harvard apparatus ...
-
bioRxiv - Neuroscience 2021Quote: ... Whole cell and cell attached recordings of layer five neurons within neocortex were made using 4–7 MΩ pipettes (GC150F-10, Harvard apparatus, Kent) pulled using micropipette puller (Model-P87 ...
-
bioRxiv - Neuroscience 2023Quote: In preparation of electrophysiological recording experiments, rats were anesthetized (isoflurane, 4% induction, 1.5% maintenance) shaved and mounted on a stereotaxic device (Harvard Apparatus, Holliston, Massachusetts). Heart rate and blood oxygenation were continuously monitored using a Nonin 8600 series pulse oximeter (Nonin Inc. ...
-
bioRxiv - Microbiology 2021Quote: ... the system was flushed for 5 minutes at a flow rate of 30ml/h by Jensen’s medium using a syringe pump (Harvard Apparatus). Then the medium flow was stopped and 1ml of a diluted bacteria culture (OD600nm ∼ 0.01 ...
-
bioRxiv - Neuroscience 2022Quote: ... Electroporations were made by delivering 5 pulses of 35 V using a pair of gold tweezers (Genepaddles-542, Harvard Apparatus) connected to an ECM 830 electroporator (BTX Harvard Apparatus).
-
bioRxiv - Neuroscience 2021Quote: ... The animals were intraperitoneally (i.p.) injected with 5 mg/kg D-amphetamine and connected to a rotameter (LE 902, PanLab, Harvard Apparatus) coupled to a LE 3806 Multicounter (PanLab ...
-
bioRxiv - Neuroscience 2022Quote: ... 47.5 % O2 (0.6 l/ min) and 47.5 % N2O (0.4 l/ min) and maintained with 2 % isoflurane (Harvard Apparatus anesthetic vaporizer). A standard craniotomy (27 ...
-
bioRxiv - Neuroscience 2023Quote: ... Animals were placed onto a rod facing forwards on the apparatus (Accelerating RotaRod for 5 mice LE8200, Harvard Apparatus Canada). The motor was then started on acceleration mode from 4-40 rpm over 5 min ...
-
bioRxiv - Neuroscience 2023Quote: ... 10µl of CSF tracer was injected at a rate of 2µl/min for 5 minutes using a syringe pump (Harvard Apparatus). All experiments were conducted by the same operator ...
-
bioRxiv - Physiology 2023Quote: ... mice were given a constant rate infusion of dobutamine (0.625 mg/ml in normal saline containing 5% dextrose) via the tail vein using an infusion syringe pump (Harvard Apparatus). The first infusion was at the low dose of 10 μg/kg/min ...
-
bioRxiv - Neuroscience 2024Quote: ... CTAP was infused through an injector cannula coupled to a 5 µL Hamilton syringe using a microinfusion pump (Harvard Apparatus) at a continuous rate of 150 nL min-1 to a total volume of 0.5 µL per hemisphere ...
-
bioRxiv - Neuroscience 2021Quote: Mice were anesthetized using 4% isoflurane and placed in a stereotaxic frame (Kopf Instruments, Model 900) equipped with a digital micromanipulator (Harvard Apparatus, Holliston, MA). Anesthesia was maintained with 0.5-2% isoflurane and/or a cocktail of ketamine/xylazine (100/7 mg/kg i.p.) ...
-
bioRxiv - Cell Biology 2020Quote: ... with 5-mm pads and electroporated with five 50-ms pulses of 45 V using the ECM830 electroporation system (Harvard Apparatus). The uterine horns were then placed back into the abdominal cavity to continue normal brain development ...
-
bioRxiv - Neuroscience 2020Quote: ... 2 × 109 genome copies (gc) of AAV2/5 GfaABC1D-mito7-GCaMP6f was injected in a 2 μL volume using a syringe pump (Harvard Apparatus). The injection pipette was left in place for ~10 min after injection and then gradually withdrawn ...
-
bioRxiv - Neuroscience 2021Quote: ... Whole-cell current-clamp recordings were made from pyramidal cells in area CA1 of the hippocampus using patch pipettes (5– MΩ) manufactured from thick-walled glass (Harvard Apparatus). Pyramidal cells were identified by their position in the slice ...
-
bioRxiv - Neuroscience 2019Quote: ... Briefly, mice were anaesthetised with isoflurane (5% induction, 1.5-2% maintenance) and secured in a stereotaxic frame (Harvard Apparatus, Massachusetts, U.S.A). A small craniotomy was performed and up to 700nL of the viral sample was injected using a picospritzer (PV820 ...
-
bioRxiv - Neuroscience 2020Quote: ... and a 33-gauge bilateral injector (cut length 5 mm; Plastic One) attached to a syringe pump (PHD ULTRA; Harvard Apparatus) was lowered into the guide cannula previously implanted over the MFB (depth −4.8 mm from brain surface) ...
-
bioRxiv - Neuroscience 2020Quote: ... ASV infusion was carried out at 0.125 μl/min using an injection cannula extending out of PE50 tubing attached to a 5 μl Hamilton syringe (Hamilton) using a PHD 2000 Infusion Pump (Harvard Apparatus). After injection ...
-
bioRxiv - Developmental Biology 2019Quote: ... Cerebral organoids were subsequently electroporated with 5 pulses applied at 80V for 50ms each at intervals of 500ms (ECM830, Harvard Apparatus). Following electroporation ...
-
bioRxiv - Neuroscience 2021Quote: ... 350 nl at 700 nm depth and 350 nl at 400 nm depth) using a Hamilton syringe (5 μl, 32-gauge) and an infuse/withdrawal pump (Harvard Apparatus). pAAV-CamKiia-eNpHR3.0-EYFP was a gift from Karl Deisseroth (Addgene viral prep #26971-AAV1 ...
-
bioRxiv - Neuroscience 2020Quote: ... Briefly, mice were anaesthetised with isoflurane (5% induction, 1.5-2% maintenance) and secured in a stereotaxic frame (Harvard Apparatus, Massachusetts, U.S.A). Two small craniotomies were performed and up to 700 nL of viral sample was injected using a picospritzer (PV820 ...
-
bioRxiv - Neuroscience 2022Quote: ... Larvae were injected in the left brain hemisphere with 5 nl of nKTP solution using pulled borosilicate glass microcapillary (GC100F-15, Harvard Apparatus) pipettes under a stereomicroscope (MZ10F ...
-
bioRxiv - Neuroscience 2023Quote: ... Whole-cell current-clamp recordings were made from pyramidal cells in area CA1 of the hippocampus using patch pipettes (5–10 MΩ) manufactured from thick-walled glass (Harvard Apparatus). Pyramidal cells were identified by their position in the slice ...
-
bioRxiv - Neuroscience 2023Quote: ... Current clamp and voltage clamp recordings were performed with pipettes (5- to 7-MΩ resistance) prepared from borosilicate glass (BF150-86-10; Harvard Apparatus) using a DMZ pipette puller (Zeitz) ...
-
bioRxiv - Neuroscience 2023Quote: ... Volumes for bilateral HPC infusions were 200 nl/hemisphere (rate = 5 μL/min) via a 33-gauge injector and microsyringe attached to an infusion pump (Harvard Apparatus). Injectors were left in place for 20 s after infusions ...
-
bioRxiv - Neuroscience 2023Quote: ... The bowel was removed and placed in warmed (37°C), oxygenated (95% O2, 5% CO2) Krebs-Ringers solution in a horizontal organ bath (Hugo Sachs Elektronik, Harvard Apparatus)35 ...
-
bioRxiv - Neuroscience 2023Quote: ... which was attached to a 5 μL Hamilton syringe (Hamilton, Reno, NV) that was placed in an infusion pump (CMA syringe pump 4004; Harvard apparatus). We infused rimonabant (2 µg/µL ...
-
bioRxiv - Neuroscience 2023Quote: ... Embryos were electroporated at E15.5 by applying electric pulses (50V; 50ms on/950ms off/5 pulses) with an electric stimulator (BTX Electroporator ECM 830 (Harvard Apparatus)) using round electrodes (CUY650P5 ...
-
bioRxiv - Bioengineering 2023Quote: ... The micropipette holder was connected to a 5 ml syringe which was pre-filled with PBS and mounted on a syringe pump (PHD 2000, Harvard Apparatus). The glass tube was inserted into the brain tissue to the targeted coordinates ...
-
bioRxiv - Biophysics 2024Quote: ... we kept the flow at a rate of 5 ml/min in both source and sink channels with a syringe pump (Pump-22; Harvard Apparatus). The potassium ions could diffuse from the source channel to the sink channel and form a linear gradient in the observing channel ...
-
bioRxiv - Microbiology 2022Quote: ... Mice were injected with 0.5 μL of sterile 0.9% NaCl or 2 × 108 CFU/mL M.tb through the brain cannula (over 5 min) using the syringe pump (Harvard Apparatus, Holliston, Massachusetts). Mice in the i.v ...
-
bioRxiv - Neuroscience 2020Quote: ... Pressure transducers were connected to a signal conditioner module (EVO-SD-5/FPI-LS-10, FISO Technologies Inc., Harvard Apparatus, Quebec, Canada) and data were continually recorded using the Evolution software (FISO Technologies Inc. ...
-
bioRxiv - Immunology 2022Quote: Mice were anesthetized using an induction chamber with an atmosphere saturated with 5% Isoflurane (Cristália®, São Paulo, Brazil) in oxygen (Isoflurane Anesthesia Vaporizer System; Harvard Apparatus, MA, USA). Using a 300 µL 30 G syringe (BD Ultra-FineTM) ...