Labshake search
Citations for Harvard Apparatus :
51 - 100 of 260 citations for 6 Quinoxalinecarboxamide 1 2 3 4 tetrahydro 3 oxo 9CI since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2024Quote: ... Recording pipettes were pulled to a tip resistance of 4–6 MΩ (Narishige PC-10) from borosilicate glass (GC150F, 1.5 mm, Harvard Apparatus, UK). For all the recordings except I-V relationship recordings ...
-
bioRxiv - Developmental Biology 2019Quote: ... 8-cell stage snail2::egfp embryos were injected in a single dorsal-animal blastomere with 1.5 ng MO 13-3 using a PLI-100A microinjector (Harvard Apparatus), and Alexa Fluor 555 dextran (Invitrogen ...
-
bioRxiv - Neuroscience 2020Quote: ... Micropipettes were prepared (tip resistance between 3 and 7 MΩ) from borosilicate glass capillaries (outer diameter 1.2 mm, inner diameter 0.69 mm) (Harvard Apparatus Ltd) using a horizontal puller (Sutter) ...
-
bioRxiv - Biophysics 2019Quote: ... Embryos used to analyze intercalation were transferred to a 3% ficoll solution in 1X MBS and were injected (Harvard Apparatus) with approximately 1ng mRNA encoding a membrane tagged GFP (mem-GFP [63] ...
-
bioRxiv - Physiology 2023Quote: ... We analyzed parameters such as total distance traveled in video recordings using SMART 3 software (Panlab Harvard Apparatus, Barcelona, Spain).
-
bioRxiv - Neuroscience 2023Quote: ... Micropipettes were prepared (tip resistance between 3 and 7 MΩ) from borosilicate glass capillaries (outer diameter 1.2 mm, inner diameter 0.69 mm, Harvard Apparatus Ltd) using a horizontal puller (Sutter) ...
-
bioRxiv - Neuroscience 2019Quote: ... and anaesthetised with isoflurane (2% for induction, 1 - 2% for surgery, 1% for electrophysiology in 1.2% O2, Harvard Apparatus, UK). To maintain clear airways and avoid tracheal secretions ...
-
bioRxiv - Neuroscience 2019Quote: ... and anaesthetised with isoflurane (2% for induction, 1 – 2% for surgery, 1% for electrophysiology in 1.2% O2, Harvard Apparatus, UK). A vaporizer controlled the isoflurane concentration and a scavenger retrieved superfluous anaesthetic ...
-
bioRxiv - Neuroscience 2022Quote: ... mechanically ventilated (2-4 mL tidal volume; VentElite Small Animal Ventilator, Harvard Apparatus, Holliston, MA, USA), and bilaterally vagotomized to prevent mechanosensory feedback from ventilation ...
-
bioRxiv - Neuroscience 2021Quote: ... Recording electrodes with impedance of 3-5 MΩ were pulled from borosilicate glass capillaries (Harvard Apparatus, Kent, UK; 1.5 mm OD) using a micropipette electrode puller (DMZ Universal Puller) ...
-
bioRxiv - Neuroscience 2022Quote: ... were delivered five times at 950-ms intervals by using 3-mm tweezer-type electrodes and an electroporator (BTX ECM 830, Harvard Apparatus). Embryos were returned to their dam and allowed to develop until they were harvested for analysis.
-
bioRxiv - Neuroscience 2020Quote: ... Retro AAV viral construct was injected (3 x 200 nl) via glass syringe (30-50 um diameter) using a syringe pump (Pump 11 Elite, Harvard Apparatus) bilaterally in IC ...
-
bioRxiv - Neuroscience 2021Quote: An optical window (made from two 3 mm glass coverslips and a 5 mm glass coverslip (Harvard Apparatus, Holliston, MA, USA) sealed with optical adhesive (Norland ...
-
bioRxiv - Neuroscience 2020Quote: ... were targeted under oblique infra-red illumination based on somatic morphology and patch clamped using 2-6 MΩ boroscillicate glass electrodes (GC150-10F, Harvard Apparatus) filled with potassium gluconate internal for current-clamp experiments (in mM ...
-
bioRxiv - Bioengineering 2023Quote: ... The cells were loaded into a 20 ml syringe and injected into the device at a flow rate of 2 ml/min for low-speed mode and 3 ml/min for high-speed mode using a syringe pump (PHD ULTRA Syringe Pumps, Harvard Apparatus, USA). To implement the recirculation strategy ...
-
bioRxiv - Neuroscience 2024Quote: ... EVs were delivered in multiple microinjections over 3 minutes using air pressure from a PLI-100A Pico-Injector (Harvard Apparatus, Cambridge, UK), and were allowed to diffuse during 4 minutes before the needle was withdrawn ...
-
bioRxiv - Molecular Biology 2020Quote: ... in mice anesthetized with isoflurane (1.5 – 2% for induction and 1 – 2 % for maintenance of anesthesia; Isotec 100 Series Isoflurane Vaporizer; Harvard Apparatus). Mouse core body temperature (monitored by a rectal probe) ...
-
bioRxiv - Neuroscience 2022Quote: We glued a pollen granule sold as nutritional supplement (Morga Bluetenpollen, Morga AG) to a 2-mm borosilicate glass tube (TG200-4, Harvard Apparatus) with Super RTV Silicone Transparent (Wuerth) ...
-
bioRxiv - Neuroscience 2019Quote: 2-month-old mice were trained on 3 consecutive days with at least 2 trials per day on an accelerating rotarod (4 rpm to 45 rpm over 5 mins, Harvard apparatus, UK). A training trial was considered successful when the mice stayed on the rod for at least 45 sec ...
-
bioRxiv - Physiology 2024Quote: ... All solutions continuously superfused the cultured cells with a gravitational-driven 6-channel perfusion system through a miniature manifold (MM-6; Harvard Apparatus) at a rate of ∼0.75 ml/min ...
-
bioRxiv - Microbiology 2021Quote: ... The unbound Fn was removed by a flow of PBS (6 ml hour-1) using a syringe pump (Harvard Apparatus, USA) for 15 minutes ...
-
bioRxiv - Neuroscience 2022Quote: ... was injected into V1 iontophoretically by pulses of positive DC-current (6 s on/off alterations, 6 μA, 10 min) using glass micropipettes (20 μm tip, Harvard apparatus, 30-0044). After the injection was completed ...
-
bioRxiv - Neuroscience 2022Quote: ... Tower Optical) bonded (Norland Optical Adhesive 61, Norland) to a 4 mm #1 round coverslip (Harvard Apparatus), glued in place first with tissue glue (VetBond ...
-
bioRxiv - Neuroscience 2022Quote: To measure the response of sDarken to exogenous serotonin 10 μM 5-HT was applied using a customized borosilicate glass pipette (Harvard Apparatus, ~ 2-4 μm diameter). To image the response of sDarken to endogenous serotonin release ...
-
bioRxiv - Neuroscience 2020Quote: ... mice were anesthetized with isoflurane (1-2%) and kept on a heating blanket (Harvard Apparatus). Lidocaine was used as a local analgesic and injected under the scalp at the start of surgery ...
-
bioRxiv - Neuroscience 2023Quote: ... A CSF tracer (6 µl) was infused at a constant rate of 1 µl/minute with a syringe pump (Harvard Apparatus, Holliston, MA, USA). During the experiment ...
-
bioRxiv - Neuroscience 2022Quote: ... of C57Bl/6 mice using a glass pipette attached to tubing and a 1 μl Hamilton syringe in a syringe pump (Harvard apparatus; rate: 100 μl/min). The injection pipette was slowly withdrawn 5 minutes after the end of the infusion ...
-
bioRxiv - Bioengineering 2021Quote: ... a flow rate of 2 µL min−1 was applied via a syringe pump (PhD Ultra, Harvard apparatus). A confluent monolayer was obtained in 36 h.
-
bioRxiv - Biophysics 2024Quote: ... a flow rate of 2 µL min−1 was applied via a syringe pump (PhD Ultra, Harvard apparatus). A confluent monolayer was obtained in 24 hours ...
-
bioRxiv - Developmental Biology 2023Quote: ... The left eye of E14.5 embryos was injected with 2 μg·μL-1 of DNA using an elongated glass capillary (Harvard apparatus) with different plasmid solutions ...
-
bioRxiv - Biophysics 2023Quote: ... Continuous phase oil was then perfused into the chip using a syringe pump in withdrawal mode at 4 µL min-1 (Pump 11 Elite, Harvard Apparatus, USA), which eventually resulted in droplets loading into the array ...
-
bioRxiv - Neuroscience 2020Quote: ... The microdialysis probes (6 kDa MW cut-off, CMA 11, Harvard Apparatus, Catalogue# CMA8309581) were calibrated with freshly made dopamine solutions (0 ...
-
bioRxiv - Neuroscience 2019Quote: ... Patch pipettes (5-6 MΩ) were pulled from borosilicate glass (GC150F-10, Harvard Apparatus) and filled with (in mM) ...
-
bioRxiv - Neuroscience 2020Quote: ... Patch pipettes were obtained from borosilicate glass microelectrodes (6-9 MΩ; Harvard Apparatus, UK), pulled through a PC-10 puller (Narishige ...
-
bioRxiv - Neuroscience 2021Quote: Mice were anesthetized with 1 - 2% Isoflurane and body temperature maintained at 37⁰C with heating pad and thermistor (Harvard Apparatus). To stimulate forelimb and hindlimb ...
-
bioRxiv - Neuroscience 2020Quote: ... under isoflurane anesthesia (1.5-2% + oxygen at 1 L/min) and body temperature maintained at 30°C throughout surgery (Harvard Apparatus, #50722F). Briefly ...
-
bioRxiv - Neuroscience 2024Quote: ... mice were anesthetized under isoflurane (1-2% in O2; Surgivet) and mounted in a stereotaxic apparatus (David Kopf Instruments) with a thermal blanket (Harvard Apparatus). Mice were given a subcutaneous injection of Marcaine or Lidocaine for local analgesia and an intraperitoneal injection of Ketoprofen to reduce inflammation ...
-
bioRxiv - Neuroscience 2021Quote: ... The stereotaxic system used was the same as for neonate injections of 6-OHDA (Harvard Apparatus), except that adult ear bars were used instead of the neonate head mold ...
-
bioRxiv - Neuroscience 2022Quote: ... Cells were pulsed once at 130V for 6 mS with the ECM 830 instrument (Harvard Apparatus). After electroporation ...
-
bioRxiv - Animal Behavior and Cognition 2023Quote: ... The drug was then infused with a syringe pump at a volume of 1 μl over a period of 2 min (Pump 11 Elite, Harvard Apparatus, Holliston, Massachusetts, USA). After the infusion ...
-
bioRxiv - Bioengineering 2020Quote: ... This mixture was then transferred into a 2-mm gap length 96-well electroporation plate (HT-P96-2, Harvard Apparatus) and electroporated in a Gene Pulser XCell (Biorad ...
-
bioRxiv - Molecular Biology 2022Quote: ... in mice anesthetized with isoflurane (2% for induction and 2 % for maintenance of anesthesia; Isotec 100 Series Isoflurane Vaporizer; Harvard Apparatus). AF was defined as the occurrence of rapid and fragmented atrial electrograms with irregular AV-nodal conduction and ventricular rhythm for at least 1 second ...
-
bioRxiv - Neuroscience 2021Quote: ... Patch pipettes with a resistance range of 5-6 MΩ were made from borosilicate glass capillaries (GC150T-10, Harvard Apparatus) using a vertical puller (PC-10 ...
-
bioRxiv - Neuroscience 2023Quote: ... These guide cannulas were then used to insert the microdialysis probes (6 kDa MW cut-off, CMA 7, Harvard Apparatus) into the target sites ...
-
bioRxiv - Cell Biology 2020Quote: ... Patch electrodes (≈4 MΩ) were pulled from borosilicate glass capillaries (GC150T, Harvard Apparatus) using a vertical micropipette puller (Narishige ...
-
bioRxiv - Molecular Biology 2020Quote: ... 2-5 MΩ borosilicate glass electrodes (GC150-10F, Harvard Apparatus) filled with aCSF were placed into the stratum radiatum of a GFP positive region of CA1 and a bipolar stimulating electrode (CBAPB50 ...
-
bioRxiv - Neuroscience 2020Quote: ... mice were anesthetized with isoflurane (2% in oxygen, Harvard Apparatus) and positioned onto a small animal physiological monitoring System (ST2 75-1500 ...
-
bioRxiv - Neuroscience 2021Quote: ... both sides of the embryo’s head were gently grabbed and a third electrode connected to the positive pole was placed slightly shifted below lambda to target the visual cortex and electroporated with 6 pulses at 30 V with a 1s delay using an Electro Square Porator (BTX Harvard Apparatus). After the procedure ...
-
bioRxiv - Biophysics 2020Quote: ... the solutions in the 10 ml syringe reservoirs were raised to a constant higher temperature using the SW-10/6 multi-syringe warmer alongside with the TC-324B controller (Warner instruments/Harvard Apparatus). The temperature of the solution ...
-
bioRxiv - Neuroscience 2024Quote: ... bubbled with 95% O2 – 5% CO2. Patch micropipettes (open tip resistance of approx. 6 MΩ) were pulled from borosilicate glass capillaries (Harvard Apparatus), using the Sutter Instruments P97 puller and filled with the solution containing (in mM) ...