Labshake search
Citations for Macherey-Nagel GmbH :
1 - 50 of 63 citations for Adenovirus Type 5 Particles Wild type since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Developmental Biology 2023Quote: ... Total RNA was extracted from wild-type worms using the Nucleospin RNA® kit (Macherey-Nagel – 740955) or Trizol Reagent™ (Ambion® ...
-
bioRxiv - Developmental Biology 2020Quote: ... DNA from a male wild type blood sample (2 ml) was purified with the NucleoBand®HMW DNA Kit (Macherey-Nagel). To eliminate fragments below 40 kb the Short Read Elimination Kit XL (Circulomics ...
-
bioRxiv - Cell Biology 2021Quote: ... flanking Cas9 targeted site was amplified from genomic DNA extracted from wild type MCF10A cells (NucleoSpin tissue extraction kit, Macherey-Nagel), Puro-T2A were amplified from the custom-made plasmid MXS Puro bGHpA using primers containing T2A sequence ...
-
bioRxiv - Developmental Biology 2024Quote: ... PCR products were run on gel electrophoresis before gel extraction of bands of interest (with sizes corresponding to either a wild-type allele or a deleted allele) (Nucleospin gel and PCR clean-up, Macherey-Nagel Cat# 740609.50). Fragments were cloned into blunt-end TOPO vector (Invitrogen Cat# 45024) ...
-
bioRxiv - Microbiology 2023Quote: ... The filters were then individually placed into 5 mL Type A Bead-Tubes (ref. 740799.50, Macherey-Nagel), added with 1,200 µL MWA1 lysis buffer and stored at - 80°C until nucleic acids extraction as specified in the corresponding section below.
-
bioRxiv - Microbiology 2023Quote: ... slight adaptations were made from manufacturer’s instructions: half MCE filters were placed into individual 5 mL Type A Bead-Tubes (ref. 740799.50, Macherey-Nagel) and added with 1,200 µL MWA1 lysis buffer ...
-
bioRxiv - Microbiology 2022Quote: ... Filter pieces were transferred into MN Bead Tubes Type A (Macherey-Nagel) containing 800 μl of buffer RLT Plus that were pre-chilled at −80°C for 10 minutes ...
-
bioRxiv - Bioengineering 2019Quote: ... filtered over a 0.45 μm filter (type PA-45/25, Macherey-Nagel, Germany), and diluted with Milli-Q water to reach the desired concentration range for quantification between 1 and 100 mg L−1 ...
-
bioRxiv - Bioengineering 2019Quote: ... filtered over a 0.22 µm filter (type PA-45/25, Macherey-Nagel, Germany) and diluted with Milli-Q water to reach the desired concentration range for quantification between 1 and 100 mg L−1 ...
-
bioRxiv - Bioengineering 2021Quote: ... followed by filtration over a 0.45 μm filter (type PA-45/25, Macherey-Nagel, Germany) to remove all solids ...
-
bioRxiv - Developmental Biology 2023Quote: ... elegans animals were transferred to 2 ml MN Bead Tubes Type A (Macherey-Nagel, Düren, Germany) and lysed using a Precellys Bead Beating system with an additional Cryolys cooling module (Bertin Instruments ...
-
bioRxiv - Molecular Biology 2021Quote: ... total RNA was extracted from mESCs and MEFs (3 biological replicates of WT and Atxn7l3−/− for each cell types) using the NucleoSpin RNA isolation kit (Macherey-Nagel), according to manufacturer’s instructions ...
-
bioRxiv - Microbiology 2019Quote: ... compounds were separated by reverse-phase chromatography using Ultra Performance Liquid chromatography (UPLC IClass, Waters) using a Nucleodur C18ec column (2.0 mm × 150 mm, 5 μm particle size, Macherey-Nagel). Elution was achieved by increasing the acetonitrile/water (milliQ filtrated on 0.22 μm ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... The drug concentration in samples was measured with high-performance liquid chromatography (HPLC) using a reverse phase C18 Nucleosil 100-5 (4.0 × 250 mm; 5.0 μm particle size, Macherey-Nagel, Germany) column and mobile phase consisting of MeOH/water (90/10 v/v ...
-
bioRxiv - Plant Biology 2021Quote: ... 1 μL of sample was injected onto an RP18 column (4 × 50 mm, 2.7 μm particle size, Nucleoshell, Macherey-Nagel) with a flow rate of 0.25 mL min−1 ...
-
bioRxiv - Plant Biology 2021Quote: ... Chromatographic separation was conducted on a reversed-phase C18 column (Gravity, 50 × 2.1 mm, 1.8-µm particle size, Macherey-Nagel GmbH, Germany) using a MeOH:H2O (both supplemented with 0.1% acetic acid ...
-
bioRxiv - Biochemistry 2023Quote: ... 2 μL sample volume was injected into a Nucleodur HILIC column (250 mm * 2 mm, 3 μm particle size, Macherey-Nagel). Metabolites were eluted at 20 °C with an acetonitrile gradient (90% (v/v ...
-
bioRxiv - Microbiology 2023Quote: ... Chromatographic separations were carried out on a reversed-phase C18 column (50×2.1 mm, 1.8-µm particle size; Macherey-Nagel GmbH, Dueren, Germany) using a CH3OH:H2O (both supplemented with 0.1% acetic acid ...
-
bioRxiv - Physiology 2022Quote: ... Japan) equipped with an analytical CN-RP column (NUCLEODUR 100-5, CN-RP, 150 × 4.6, 5 µm column; Macherey-Nagel GmbH & Co. KG, Düren, Germany) and a UV-diode-array detector ...
-
bioRxiv - Biochemistry 2021Quote: ... with an EC 250/4 NUCLEODUR 100-5 C18 ec column (Macherey-Nagel) with a general gradient of 10% to 90% ACN in H2O ...
-
bioRxiv - Plant Biology 2020Quote: ... Nucleosil 100-5 N(CH3)2 column (Macherey-Nagel GmbH & Co, Düren, Germany) and eluted isocratically with 100% methanol containing 0.01% acetic acid at a flow rate of 1 ml min-1 ...
-
bioRxiv - Molecular Biology 2023Quote: ... The reaction mixture was diluted 5-fold with the NTC buffer (Macherey-Nagel), and the reverse transcription products were purified using a NucleoSpin Gel and PCR Clean-up kit (Macherey-Nagel) ...
-
1H NMR chemical exchange techniques reveal local and global effects of oxidized cytosine derivativesbioRxiv - Biophysics 2021Quote: ... As stationary phase Nucleodur columns (250/10 mm, C18ec, 5 μm) from Macherey-Nagel were used ...
-
bioRxiv - Immunology 2022Quote: ... BEAS-2B and MRC-5 using NucleoSpin® Viral RNA Isolation kit (Macherey-Nagel). One-Step RT-PCR SuperScript™ III Platinum™ Kit (Life Technologies ...
-
bioRxiv - Molecular Biology 2021Quote: ... The cleared lysate was loaded onto a 5 mL Ni-NTA column (Macherey-Nagel). After washing with a buffer consisting of 20 mM Tris pH 8.0 ...
-
bioRxiv - Microbiology 2021Quote: ... followed by rapid filtration through membrane filters (MN gf-5 0.4 μm; Macherey-Nagel). The filters were dissolved in 5 ml of scintillation fluid (MP Biomedicals) ...
-
bioRxiv - Plant Biology 2023Quote: ... thaliana 5-days-old seedlings was isolated using NucleoSpinTM RNA Plant Kit (Macherey-Nagel) according to the manufacturer’s instructions ...
-
bioRxiv - Microbiology 2023Quote: ... VII-1-1 and IX-5-2 (Genomic DNA extraction kit, Macherey-Nagel, Hoerdt) by using the primers listed in Table S4 ...
-
bioRxiv - Biochemistry 2021Quote: ... with a VP 250/10 NUCLEODUR 100-5 C18 ec column (Macherey-Nagel, Düren, Germany) running a general gradient of 10% to 70% acetonitrile (ACN ...
-
bioRxiv - Cell Biology 2022Quote: ... and EBs at day 5 using the NucleoSpin RNA Plus Kit (Macherey-Nagel, Düren, Germany) and quantified with a NanoDrop ND-2000 spectrophotometer (Thermo Scientific ...
-
bioRxiv - Plant Biology 2022Quote: ... with the difference that a Nucleodur 100-5 NH2 125x4 mm column (Macherey-Nagel, #760730.40) and an eluent consisting of 8.5% acetonitrile and 25mM formic acid pH 4 were used (18) ...
-
bioRxiv - Developmental Biology 2024Quote: ... the cleared lysate was loaded onto a 5 mL Protino GST/4B column (Macherey-Nagel) and washed with 10 column volumes of lysis buffer ...
-
bioRxiv - Molecular Biology 2021Quote: Genomic DNA was isolated from 5 Mio HeLa cells using the NucleoSpin tissue kit (Macherey-Nagel) according to the manufacturers protocol.
-
bioRxiv - Biochemistry 2024Quote: ... SSC was separated on a 250 x 3 mm 5 µm Nucleodur HTec C18 (Macherey-Nagel) column ...
-
bioRxiv - Immunology 2020Quote: Genomic DNA was extracted from 5×106 B16F10 tumor cell lines using NucleoSpin® Tissue (MACHEREY-NAGEL), according to manufacturer instructions ...
-
bioRxiv - Genetics 2021Quote: Genomic DNA from 5 males was extracted using the NucleoSpin Tissue XS kit (Macherey-Nagel, ref #740 901). To amplify the Rsp satDNA region ...
-
bioRxiv - Plant Biology 2021Quote: ... dissolved and fractionated by RP-HPLC using a Nucleodur 100-5 C18ec 125×4.6 mm column (Macherey-Nagel). The ABA-containing fraction was collected ...
-
bioRxiv - Molecular Biology 2023Quote: ... 0.5 mM PMSF and purified by immobilized metal affinity chromatography using a 5 ml nickel column (Macherey-Nagel). The protein was eluted from the nickel column with solubilization buffer supplemented with 500 mM imidazole ...
-
bioRxiv - Synthetic Biology 2023Quote: ... preparative HPLC was employed using a reversed-phase C18 column (Macherey-Nagel VP 250/21 Nucleodur 100-5) with a mobile phase solvent A (Water + 0.05% vol/vol trifluoroacetic acid (TFA)) ...
-
bioRxiv - Microbiology 2022Quote: ... For Clr purification the initial purification was conducted using a 5 mL Protino™ Ni-NTA Column (Macherey-Nagel). Size-exclusion chromatography over a 16/600 Superdex 200 column (GE ...
-
bioRxiv - Plant Biology 2022Quote: Total RNA was extracted from roots of plants 5 days after germination using RNA protein purification kit (Macherey-Nagel). Next generation sequencing (NGS ...
-
bioRxiv - Genetics 2019Quote: Total RNA from pools of 5 oocytes were extracted using the Nucleospin RNA XS kit according to the manufacturer’s protocol (Macherey-Nagel) and including a DNase1 treatment ...
-
bioRxiv - Molecular Biology 2022Quote: Total RNA was isolated from around 5×105 to 1×106 cells using the NucleoSpin RNA Plus (MACHEREY-NAGEL, 740984.50) or Quick-RNA Miniprep Kit (Zymo Research ...
-
bioRxiv - Systems Biology 2023Quote: ... cDNA was generated by isolating RNA from 5×106 HEK293T cells with the Nucleospin RNA isolation Mini kit (Macherey-Nagel)according to the manufacturer’s instructions ...
-
bioRxiv - Plant Biology 2024Quote: ... Samples (80 µL) were separated on a NUCLEOSIL® C18 column (EC 250/4, 300-5, MACHEREY-NAGEL GmbH, Germany) in a LaChrome Elite HPLC equipped with an L-2130 pump module ...
-
bioRxiv - Molecular Biology 2019Quote: ... Cells were collected 5 days after transfection and the cell’s genomic DNA was prepared using NucleoSpin Tissue (MACHEREY-NAGEL & Co. KG).
-
bioRxiv - Developmental Biology 2021Quote: ... and the reverse primer 5’AACCCAGGTAATGAACACAGTTTCTAT. PCR products were run on a gel (supplemental Fig. 2B) and bands were gel purified (Macherey-Nagel), inserted in a pCR-bluntII-Topo vector (Invitrogen ...
-
bioRxiv - Microbiology 2022Quote: ACE and its metabolites ANSA and acetoacetate were quantified by HPLC with an UV/VIS detector employing a Nucleosil 100-5 C18 HD column (240/3 mm, Macherey-Nagel) and an eluent at 0.5 ml min−1 containing 100 mM NaH2PO4 and 10 mM tetrabutylammoniumhydrogensulfate ...
-
bioRxiv - Plant Biology 2022Quote: ... Plasmids were extracted from positive colonies using 5 mL liquid cultures with the NucleoSpin Plasmid Purification kit (Macherey-Nagel; Ref.: 11932392) and sequenced (GATC ...
-
bioRxiv - Plant Biology 2022Quote: Total RNA was extracted from roots of 5 days old seedlings (both controls and treated with NaCl) using the NucleoSpin RNA Plus (Macherey-Nagel). Reverse-transcription was performed using using the SuperScript III First-Strand VILO cDNA Synthesis Kit (ThermoFisher Scientific) ...