Labshake search
Citations for Bio-Rad :
401 - 450 of 558 citations for 8 6 AMINOHEXYL AMINOADENOSINE5 TRIPHOS PHATE LITH since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2020Quote: ... 0.14 M NaCl (PBS) followed by removal of the reductant using a Micro Bio-Spin 6 column (Bio-Rad). Columns were washed and pre-equilibrated with 20 mM phosphate buffer pH 7.4 containing 0.1 mM diethylenetriamine-penta-acetic acid (DTPA ...
-
bioRxiv - Biochemistry 2021Quote: ... individual proteins were buffer exchanged into 200 mM ammonium acetate pH 8.0 either by SEC or using Biospin-6 (BioRad) columns and introduced directly into the mass spectrometer using gold-coated capillary needles (prepared in-house) ...
-
bioRxiv - Biochemistry 2020Quote: ... His-tagged protein was detected using a mouse anti-6×His IgG conjugated to horseradish peroxidase (MCA1396P; Bio-Rad), and the blot was developed using Pierce™ ECL Western Blotting Substrate (Thermo Fisher Scientific).
-
bioRxiv - Biochemistry 2020Quote: ... The annealed doubly nicked DNA duplex was then buffer-exchanged in Hepes 20 mM pH 7.5 with a BioSpin 6 column (BioRad).
-
bioRxiv - Biophysics 2022Quote: ... The protein-dye conjugate was purified by 3 rounds of size exclusion chromatography (Bio-Spin 6 column, BioRad, CA) and then aliquoted in 5 μL portions and stored at -80C until required.
-
bioRxiv - Microbiology 2022Quote: All proteins were buffer exchanged into 0.2 M ammonium acetate using Bio-Spin P-6 Size Exclu-sion Spin Columns (BioRad) as previously described47 ...
-
bioRxiv - Genetics 2022Quote: ... PMOs were buffer exchanged into 25 mM ammonium bicarbonate buffer pH 7.5 using Biospin 6 (Bio-rad, Hercules, California) columns according to the manufacturer’s protocol and then spinning through an 0.22 µm cellulose acetate centrifugal spin filter ...
-
bioRxiv - Neuroscience 2019Quote: ... Neurons were biolistically transfected after 5-6 days in vitro using a Helios Gene Gun (120 psi; Bio-Rad) with pLenti-hSyn-eNpHR3.0-EYFP (eNpHR3.0 fused to EYFP and driven by the human synapsin I promoter ...
-
bioRxiv - Genetics 2019Quote: ... 10 mM L-serine) to a UapA concentration of 20 μM using Micro Bio-Spin 6 columns (Bio-Rad). UapA was loaded into gold coated capillaries and the protein sprayed into a Synapt G2-Si (Waters ...
-
bioRxiv - Neuroscience 2019Quote: ... and each qPCR reaction was performed with 6 ng cDNA and Bio-Rad IQ SYBR Green Supermix (Bio-Rad CFX384 Touch Real Time PCR Detection System ...
-
bioRxiv - Biochemistry 2019Quote: ... The annealed doubly nicked DNA duplex was then buffer-exchanged in Hepes 20 mM pH 8.0 with a BioSpin 6 column (BioRad).
-
bioRxiv - Evolutionary Biology 2020Quote: ... The Chlorella DNA was extracted by isolating the Chlorella and then using a standard 6% Chelex100 resin (Bio-Rad) extraction method ...
-
bioRxiv - Biochemistry 2019Quote: ... Buffer exchange or removal of excess NTPs and abortive products were performed by gel filtration (BioRad Micro-Spin 6), if necessary.
-
bioRxiv - Biophysics 2019Quote: ... Gel precursor solutions were prepared with 6% v/v acrylamide and 0.2% v/v bisacrylamide (30% acrylamide/bisacrylamide stock 29:1, BioRad), 2 mM LAP photoinitiator (Sigma ...
-
bioRxiv - Microbiology 2021Quote: ... pH 7.4) in D2O using Micro Bio-Spin® Columns with Bio-Gel® P-6 (Bio-Rad Laboratories). Protein (final concentration 20 µM ...
-
bioRxiv - Immunology 2020Quote: ... Mono-Mac-6 effector cells previously stimulated with recombinant human IFN-ɣ (Bio-Rad, Hercules, CA, USA; cat. PHP050) at 0.2 µg ml-1 for 3h at 37 °C ...
-
bioRxiv - Immunology 2022Quote: ... Excess free Texas Red or TAMRA were removed with Bio-spin 6 kDa size exclusion columns (Bio-Rad Laboratories) equilibrated with PBS according to manufacturer’s instructions ...
-
bioRxiv - Pathology 2023Quote: ... Heparin Sepharose 6 Fast Flow beads (Healthcare Life Sciences) were loaded into Bio-Spin® chromatography columns (Bio-Rad) and packed with 2 ml of equilibration buffer (0.15 M NaCl in 25 mM HEPES ...
-
bioRxiv - Genomics 2023Quote: ... Excess dye was removed using Micro Bio-Spin® Columns with Bio-Gel® P-6 (cat:7326221, BioRad) by centrifugation at 1000g ...
-
bioRxiv - Genetics 2023Quote: ... followed by purification and size selection on 1% agarose gel with .6 µg/mL ethidium bromide (BioRad Cat#1610433), selecting for the 7,961 bp band ...
-
bioRxiv - Synthetic Biology 2023Quote: ... The reactions were run at 125 V for 2.5 hours on a denaturing (6 M urea) 20% (w/v) polyacrylamide gel in 50 mM NaOAc pH 5.2 running buffer (using the Biorad Mini- PROTEAN tetra gel ...
-
bioRxiv - Microbiology 2023Quote: ... resuspended in 400 µL cold PBS and electroporated with 6 µg of RNA in 0.4-cm electroporation cuvettes (Biorad) with a 950 μF and 260 V pulse using Genepulser system (Biorad) ...
-
bioRxiv - Physiology 2024Quote: ... 6 μg of protein from each sample was loaded into a 4-20% Mini-PROTEAN® TGX gel (BioRad) and proteins were separated by size using electrophoresis ...
-
bioRxiv - Plant Biology 2023Quote: ... Samples containing 6 µg total protein were resolved using pre-cast SDS-PAGE Any KD™ gels (BIO-RAD), transferred to a polyvinylidene difluoride membrane (Immobilon-FL 0.45 µm ...
-
bioRxiv - Evolutionary Biology 2021Quote: ... Protein separation was done by 1D SDS-PAGE electrophoresis using commercial gels to ensure reproducibility (8–16% Criterion™ TGX™ Precast Midi Protein Gel, Bio-Rad). A sample of venom of ISm and ISy lines ...
-
bioRxiv - Neuroscience 2020Quote: ... Diabetes-associated markers and cytokine levels in the plasma were assessed using the Bio-Plex Pro Mouse Diabetes 8-Plex Assay (Cat# 171F7001M; Bio-Rad, Carlsbad, California) and the Bio-Plex Pro Mouse Cytokine 23-Plex Assay (Cat# M60009RDPD ...
-
bioRxiv - Cell Biology 2020Quote: ... Total protein (5–20 μg) was resolved onto 8–12% SDS-PAGE and blotted onto 0.2 μm pore size PVDF membranes (1620177, Bio-Rad, Hercules, CA, USA). Primary antibodies were incubated overnight at 4°C after blocking membranes for 1h ...
-
bioRxiv - Microbiology 2021Quote: All melt-MAMA PCRs were performed on a CFX96 Real-Time PCR Detection System using white hard shell 96-well PCR plates or 0.2 mL 8-tube PCR strips (Bio-Rad, Gladesville, NSW, Australia), and PCR results examined using the CFX Maestro v4.1.2433.1219 software (Bio-Rad) ...
-
bioRxiv - Microbiology 2021Quote: ... 40 μg of ΔORF3-E mNG RNA and 20 μg of N-gene RNA were electroporated into 8×106 Vero-ORF3-E cells using the Gene Pulser XCell electroporation system (Bio-Rad, Hercules, CA) at a setting of 270V and 950 μF with a single pulse ...
-
bioRxiv - Immunology 2020Quote: ... 30-50µg of protein per lane alongside a prestained molecular weight protein marker was separated on an 8% SDS PAGE gel prepared from SDS-PAGE kit (Beyotime, China) and electrotransferred to immunoblot PVDF membrane (BIO-RAD, CA, USA) for protein blotting ...
-
bioRxiv - Molecular Biology 2022Quote: ... chromatin samples were dissolved in SDS-containing loading buffer and the electrophoresis was carried out in 8-16% mini-protean TGX Bio-Rad gels (Cat. # 4561105, Bio-Rad, Hercules, CA) gradient acrylamide gels as described (Laemmli ...
-
bioRxiv - Immunology 2022Quote: ... Equal amount of total protein (25 μg/well) was resolved by electrophoresis on 8% Tris-Acrylamide gels and transferred onto 0.2 μm nitrocellulose membranes (Bio-Rad Laboratories, CA, US). Membranes were blocked for 1 h at room temperature in 5% skim milk diluted in Tris-buffered saline supplemented with 0.1% Tween 20 (TBST) ...
-
bioRxiv - Microbiology 2023Quote: Serum samples collected from mice were tested in duplicate in a multiplex immunoassay using magnetic beads (Mouse Th1-Th2 8-plex Bio-Rad, Hercules, CA) using the Luminex MAGPIX® system) ...
-
bioRxiv - Biochemistry 2023Quote: ... plates were stained with primuline (0.05% in acetone/water, 8/2; v/v) and photographed under long-wave UV light (Biorad ChemiDoc XRS Imaging System).
-
bioRxiv - Microbiology 2023Quote: ... for the selected clinical isolates using the indicated concentrations of antibiotics via an alamar blue reduction assay completed as described but without shaking.8 After 3 days of incubation with the alamar blue reagent (BioRad, Hercules, CA, USA), the MIC was identified as the lowest concentration of drug that inhibited the reagent color change as determined visually.
-
bioRxiv - Cancer Biology 2024Quote: ... Serum hormones were quantified on a Luminex MAGPIX platform using the Bio-Plex Pro Mouse Diabetes 8-Plex and Adiponectin Assays (Bio-Rad, Hercules, CA) and the IGF-1 mouse Luminex Discovery Assay (R&D Systems ...
-
bioRxiv - Biophysics 2021Quote: ... The uncoupled BG-GLA-NHS was removed by filtration on Micro Bio-Spin™ P-6 Gel Columns (Bio-Rad).
-
bioRxiv - Molecular Biology 2020Quote: ... approximately 250.000 cells were plated in a 6-well dish and transfected with a final concentration of 22.5 nM siRNA using siLentFect Lipid Reagent (Bio-Rad) accordingly to manufacturer’s protocol ...
-
bioRxiv - Biochemistry 2020Quote: ... MtCoaBC and MsCoaBC were exchanged into NH4OAc (500 mM, pH 7.0) solution using Micro Bio-Spin 6 chromatography columns (Bio-Rad). A sample volume of 2.5 μL was injected into a borosilicate emitter (Thermo Scientific ...
-
bioRxiv - Microbiology 2019Quote: ... YpdA and YpdAC14A proteins were pre-reduced with 10 mM DTT followed by DTT removal with Micro Biospin 6 columns (Biorad). For the biochemical activity assays of the specific BSSB reductase activity ...
-
bioRxiv - Biophysics 2019Quote: ... We then removed excess dye by four subsequent spins of the solution over Micro Bio-Spin 6 Columns (Bio-Rad) at 700 g for 2 min ...
-
bioRxiv - Molecular Biology 2019Quote: ... EtOH precipitation was performed and DNA was additionally cleaned up on Micro Bio-Spin 6 chromatography columns in SSC (BioRad) as purity was essential for oxidation of hmC ...
-
bioRxiv - Molecular Biology 2020Quote: DNA isolated from cells by phenol:chloroform isolation and ethanol precipitation was cleaned on Micro Bio-Spin P-6 SSC columns (Bio-Rad) according to manufacturer protocol ...
-
bioRxiv - Molecular Biology 2019Quote: ... Samples were boiled at 95 °C for 10 mins with 6×SDS sample buffer before loading onto 4–20% Tris-glycine gels (BioRad). Resolved proteins were transferred to nitrocellulose membranes using the Trans-Blot® Turbo system (BioRad ...
-
bioRxiv - Biochemistry 2019Quote: ... The spin-labeled protein was further concentrated and free label was removed using Micro BioSpin 6 Chromatography Columns (Bio-rad) pre-equilibrated with buffer C.
-
bioRxiv - Plant Biology 2020Quote: ... Captured elution fraction from the Strep-Tactin-affinity purification were loaded onto a anion exchange column (UNO Q-6, Biorad) with a flowrate of 4 ml/min ...
-
bioRxiv - Biochemistry 2021Quote: ... pH 5.3 (murine P-domains) or pH 7.3 (GII.4 Saga P-domain) at 4 °C via Micro Bio-Spin 6 columns (Bio-Rad) according to the manufacturer’s protocol ...
-
bioRxiv - Biochemistry 2020Quote: ... and CyaY were buffer exchanged into 200 mM ammonium acetate (pH = 7.5) using Micro Bio-Spin 6 Columns (Bio-Rad). Instrument parameters were tuned to maximize transmission but simultaneously preserve the native-like state of proteins as determined by ion mobility ...
-
bioRxiv - Neuroscience 2020Quote: ... IL-6) were quantified using a real-time PCR detection system and SsoAdvanced Universal SYBR Green Supermix kit (BIO-RAD). In brief ...
-
bioRxiv - Biophysics 2020Quote: ... Fractions containing protein were pooled and desalted to remove imidazole by gel filtration on a 50 mL BioScale P-6 column (BioRad) using resuspension buffer as the eluant.