bioRxiv - Immunology 2021Quote: ... First-strand cDNA were synthesized from total RNA using an iScript gDNA Clear cDNA synthesis Kit according to the manufacturer’s instruction (Bio-Rad, Hercules, CA, USA). Real-time PCR was performed using the StepOnePlus Real-time PCR system (Applied Biosystems ...
-
bioRxiv - Molecular Biology 2021Quote: ... Total AGT concentration in each sample was normalized by total protein concentrations measured using a DC™ protein assay kit (Bio-Rad 5000112).
-
bioRxiv - Biochemistry 2020Quote: ... Total RNA (1 µg) from each sample sets (n=3) was taken for cDNA preparation using iScript™ cDNA Synthesis Kit (Bio-Rad, USA). Real-Time qPCR was performed using PowerUp SYBR Green Master Mix (Thermo Fisher Scientific ...
-
bioRxiv - Neuroscience 2021Quote: ... was used from each sample for One-step reverse transcriptase quantitative polymerase chain reaction (RT-qPCR) using the iTaq™ Universal SYBR® Green One-Step kit (Bio-Rad) in the StepOnePlus™ Real Time PCR system (Applied Biosystems) ...
-
bioRxiv - Developmental Biology 2020Quote: ... Results were validated using qPCR experiments where mRNA was reverse transcribed into cDNA using the iScript cDNA synthesis kit (cat #1708891, Bio-Rad, Hercules, CA). SYBR Green based qPCR was performed on a CFX-Connect Real Time PCR Detection System (Bio-Rad ...
-
bioRxiv - Genetics 2019Quote: ... We measured total protein concentrations of cell lysates with the BCA protein assay kit (Pierce, Cat#23225) and diluted 40 μg of each protein with XT sample buffer (Bio-Rad, Cat#1610791) and XT reducing agent (Bio-Rad ...
-
bioRxiv - Cell Biology 2022Quote: ... RT-qPCR was performed by using a HiScript II one-step qRT-PCR SYBR green kit (Vazyme) on a CFX96 real-time PCR detection system (Bio-Rad Laboratories, Inc.). The following primers were used ...
-
bioRxiv - Immunology 2022Quote: ... and 1 μg of RNA was used as input for cDNA synthesis using the iScript cDNA synthesis kit (Bio-rad, cat. no. 1708890) or Superscript III (Invitrogen cat ...
-
bioRxiv - Neuroscience 2022Quote: ... A total of 0.2-1 µg of RNA was pre-treated with DNAse and used for cDNA synthesis using the iScript cDNA synthesis kit (Bio-Rad, Irvine, CA). Quantitative PCR (qPCR ...
-
bioRxiv - Neuroscience 2022Quote: ... Proteins were separated at 200V for 45 min and then transferred to a low-fluorescence PVDF membrane at 25V for 30 min using the Trans-Blot Turbo Transfer System and Kit (Bio-Rad, Cat. #1704275). Gels were activated by UV excitation using the Bio-Rad GelDoc XR+ System prior to transfer ...
-
bioRxiv - Pharmacology and Toxicology 2022Quote: ... Reverse transcription was performed with Onescript® cDNA synthesis kit (Abm, #G236) and qRT-PCR was undertaken using SsoAdvanced Universal SYBR® Green Supermix (Bio-Rad) and a CFX96TM Real-Time System device (Bio-Rad) ...
-
bioRxiv - Immunology 2022Quote: ... Both anti-IL-9 and the isotype antibody were purified from the culture supernatant of hybridoma cells using the Proteus protein purification spin kit (Bio-Rad, Hercules, CA). Anti-IL-13 is an IgG1 antibody (55 ...
-
bioRxiv - Neuroscience 2022Quote: ... First strand cDNA was prepared from 400 ng of total RNA and the complementary DNA strand was synthesized using iScript cDNA synthesis kit (Bio-Rad, #1708891, USA), according to the manufacturers protocol ...
-
bioRxiv - Plant Biology 2022Quote: ... 1 μg of total RNA was used as the template to synthesize cDNA using the iScript RT-PCR kit (Bio-Rad, Carlsbad, CA). qPCR was performed with the SYBR Green I nucleic acid gel stain (Sigma-Aldrich ...
-
bioRxiv - Neuroscience 2023Quote: ... and 5 U/mL aprotinin) and the protein concentrations in the lysates were determined using a BioRad protein assay kit (BioRad Laboratories, Hercules, CA). Protein samples were subjected to SDS-PAGE ...
-
bioRxiv - Evolutionary Biology 2023Quote: ... cervicornis sperm samples from 2015 were brought to a final concentration of 3 x 107 cells ml-1 after the addition of Cell Suspension Buffer and 2% agarose using the Bio-Rad CHEF Genomic DNA Plug Kits (Bio-Rad, Hercules, CA). Genomic DNA plugs were processed according to the manufacturer’s protocol and stored at 4 °C ...
-
bioRxiv - Microbiology 2024Quote: ... one-step reverse transcription droplet digital PCR (RT-ddPCR) assays were performed with the One-step RT-ddPCR Advanced Kit for probes (Bio-Rad Laboratories Ltd.), using primers and probes targeting 2’,5’-oligoadenylate synthetase 1 (OAS1) ...
-
bioRxiv - Molecular Biology 2024Quote: The synthesis of cDNA was done from 100 ng RNA in 20 μl total reaction volume using iScript Reverse Transcription Supermix kit (Cat# 1708841, Bio-Rad, Hercules, USA), without any changes from themanufacturer’s instructions ...
-
bioRxiv - Cell Biology 2024Quote: Total protein lysates were prepared from the cells followed by protein quantification using the protein DC assay kit (Bio-Rad, Cat # 5000-001) as described previously (28) ...
-
bioRxiv - Pathology 2023Quote: Rabies virus N gene was amplified by real-time quantitative PCR using iTaq™ Universal SYBR® Green One-Step Kit (BIO-RAD). The primers are as follow ...
-
bioRxiv - Microbiology 2022Quote: ... and TNF-α was analyzed by using quantitative real-time PCR according to the Biorad iScript One-Step RT-PCR Kit in a CFX96 apparatus (Bio-Rad, Hercules, CA) with the following primers (F/R) ...
-
bioRxiv - Microbiology 2023Quote: ... RNA reverse transcription and PCR amplification were performed in a single reaction using the One-Step RT-ddPCR Advanced Kit for Probes (BioRad, Hercules, CA, USA) per the manufacturer’s instructions ...
-
bioRxiv - Cancer Biology 2023Quote: ... Protein concentration in cell lysates were measured using a RC DC Protein Assay Kit (cat. no. 50000119; Bio-Rad Laboratories, Hercules, CA, USA). Immunoblotting was carried out using standard procedures ...
-
bioRxiv - Physiology 2023Quote: One hundred nanograms of total RNA was reverse-transcribed (RT) and amplified using the iScript One-Step RT-PCR kit for probes (Bio-Rad, Hercules, CA). Real-time qPCR was performed with the Bio-Rad CFX96 sequence detection system using predesigned primer/probe sets against CPT1a ...
-
bioRxiv - Developmental Biology 2023Quote: Genomic DNA was extracted from a liver of an adult female ferret using the CHEF Mammalian Genomic DNA Plug Kit (BioRad, Cat. No. #1703591). In brief ...
-
bioRxiv - Cancer Biology 2023Quote: ... The resultant homogeneous single-cell suspensions were embedded in agarose and transferred into plug molds (Bio-Rad CHEF Mammalian Genomic DNA plug kit). Plugs were allowed to solidify at 4°C and were then incubated with Proteinase K (QIAGEN ...
-
bioRxiv - Immunology 2023Quote: ... Equal concentrations of RNA (measured by NanoDrop and 1 µg for the caecum tissue) were reverse transcribed to cDNA using the iScript™ cDNA Synthesis Kit (Bio-Rad, #1708891) and stored at −20°C ...
-
bioRxiv - Cell Biology 2022Quote: ... The purified RNA was quantified by NanoDrop and 1 µg of RNA for each sample was used to generate cDNA using the iScript cDNA synthesis kit (Biorad cat. no. 1708890). Real-time PCR was performed with PowerUp SYBR Green Master Mix (Applied Biosystems cat ...
-
bioRxiv - Cancer Biology 2023Quote: Messenger RNA expression was assessed with 150 to 500 ng of total RNA using iScript cDNA Synthesis Kit (Bio-Rad, Hercules, USA, #1708891) according to manufacturer’s instructions ...
-
bioRxiv - Genetics 2023Quote: ... SYBR qPCR Master Mix kit (Q711, Vazyme, Nanjing, China) and a Bio-Rad CFX96 real-time PCR detection system (Bio-Rad, Hercules, USA) were used for qRT-PCR ...
-
bioRxiv - Evolutionary Biology 2023Quote: ... cDNA synthesis was performed for 57 samples using 500 ng of RNA per sample and the iScript cDNA Synthesis Kit (Bio-Rad Laboratories, Inc.). qPCR primers for the abovementioned genes were designed as described in Ahi & Sefc ...
-
bioRxiv - Immunology 2023Quote: ... where absolute quantification was done by the QX200 Droplet Digital PCR System in combination with the 1-Step RT-ddPCR Advanced Kit for Probes (BioRad, Hercules, United States). The limit of detection was calculated to be 10 copies per reaction.
-
bioRxiv - Immunology 2023Quote: ... The supernatant was transferred to a new microcentrifuge tube and protein concentration was determined by using a DC protein assay kit (BioRad, Cat# 500-0116). Cell lysates (500-1000 μg ...
-
bioRxiv - Biochemistry 2023Quote: ... total RNA (1 µg) was taken from the cDNA preparation using iScript™ cDNA Synthesis Kit (#1708891, Bio-Rad Laboratories, Hercules, CA, USA). Prior to cDNA synthesis ...
-
bioRxiv - Cancer Biology 2023Quote: ... Isolation of total RNA was performed using the Aurum™ Total RNA Mini-Kit according to the manufacturer’s instructions (Bio-Rad, Hercules, CA). Total RNA concentration and quality were determined using a Nanodrop 1000 (ThermoFisher) ...
-
bioRxiv - Systems Biology 2023Quote: ... Japan) and quantitative PCR using a KOD SYBR qPCR kit (TOYOBO) with CFX96 Real-Time PCR System (Bio-Rad Laboratories, Hercules, CA, USA) according to the manufacturer’s protocol ...
-
bioRxiv - Synthetic Biology 2023Quote: ... The preparation of the genomic DNA plugs was carried out according to the CHEF genomic DNA plug kit (Bio-Rad, Hercules, CA, USA). The DNA templates of sgRNA-actF and sgRNA-actR were generated by overlap extension of sgRNA-actF/sgRNA-actR and guide RNA-F plus guide RNA-R ...
-
bioRxiv - Neuroscience 2023Quote: ... We performed the reverse transcription (RT) reaction with 200 ng/µl of total RNA with the iScript gDNA clear advanced kit (Bio-Rad 172-5035) and the real time qPCR was performed with the Sso Advanced SYBR Green® Supermix (Bio-Rad 172-5270 ...
-
bioRxiv - Microbiology 2023Quote: ... The fungal burden of each fungus ball was determined by measuring the galactomannan (GM) content in the supernatant [43] using the Platelia Aspergillus enzyme immunoassay kit (Bio-Rad, Hercules, CA) according to the manufacturer’s instructions.
-
bioRxiv - Cell Biology 2024Quote: ... 1 µg RNA was synthesized to cDNA by reverse-transcription using the iScript cDNA Synthesis Kit (Bio-Rad, Hercules, CA, USA; item # 1708891). Real-time PCR was performed in 10 µl reactions containing 5 µl SsoFast EvaGreen Supermix with Low ROX (Bio-Rad ...
-
bioRxiv - Pathology 2024Quote: ... Quantitative PCR was performed to quantify Lrp2 mRNA abundance in the kidney using SsoFast™ EvaGreen® Supermix kits (Cat # 172-5204; Bio-Rad) on a Bio-Rad CFX96 cycler ...
-
bioRxiv - Microbiology 2024Quote: ... followed by real-time RT-PCR targeting highly conserved regions of the IAV matrix (M) (10) using iTaq Universal Probes One-Step Kit (Bio-Rad, 1725141, USA) following the manufacturer’s instructions ...
-
bioRxiv - Microbiology 2024Quote: ... The anti-HBs concentrations of the DBS samples were then tested using the Monolisa Anti-HBs PLUS kit (Bio-Rad, Hercules, CA, USA) with a 2.00 mIU/mL lower limit of detection (LoD ...
-
bioRxiv - Immunology 2024Quote: ... and RNA was isolated by column purification (ZymoResearch R2050) and cDNA was synthesized using the iScript Reverse Transcriptase kit (Bio-Rad, Hercules, CA). qPCR was performed using SYBR green PCR master mix (Bio-Rad).
-
bioRxiv - Cell Biology 2024Quote: Reverse transcription for qPCR was either performed using gene-specific reverse priming with the iScript™ Select cDNA Synthesis Kit (Bio-Rad #1708897) or using NEB LunaScript RT SuperMix kit (NEB #E3010L) ...
-
bioRxiv - Microbiology 2024Quote: ... Non-diluted supernatant of tissue homogenate (50 μl) was applied to Bio-plex pro mouse cytokine & chemokine assay kit (Bio-Rad, #M60-009RDPD).
-
bioRxiv - Cell Biology 2020Quote: ... RNA template (1 μg) was prepared and reverse transcription reaction was performed with iScript Advanced cDNA Synthesis Kit (Bio-Rad Laboratories, Hercules, CA, USA) according to the procedure described in the product’s instruction manual ...
-
bioRxiv - Molecular Biology 2021Quote: Total protein was extracted from SSLs using 350 μL of RIPA buffer and was purified using the Ready Prep 2-D cleanup kit (Bio-Rad, Hercules, CA, USA); the protein concentration was measured using the BCA protein assay kit (Thermo Fisher Scientific) ...
-
bioRxiv - Bioengineering 2020Quote: ... Total RNA (410 ng) was reverse transcribed into cDNA using an iScript™ Synthesis Kit on a T100™ thermal cycler (BIO-RAD, USA) according to the manufacturer’s protocol ...
-