Labshake search
Citations for Bio-Rad :
4551 - 4600 of 9281 citations for Nuclear Protein Extraction since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Immunology 2024Quote: ... All samples were loaded onto Criterion TGX stain-free protein gels (Biorad) for gel electrophoresis ...
-
bioRxiv - Immunology 2024Quote: ... 4–12% Criterion™ XT Bis-Tris Protein Gel (Bio-Rad, 3450125), NuPAGE™ MOPS SDS Running Buffer (Invitrogen ...
-
bioRxiv - Molecular Biology 2024Quote: ... 50 ul of SureBeads Protein G magnetic agarose beads (Bio-Rad, 1614023) were added ...
-
bioRxiv - Molecular Biology 2024Quote: ... Proteins were then electrotransferred onto pre-activated polyvinylidene difluoride membranes (Bio-Rad) for 2 hours on ice ...
-
bioRxiv - Microbiology 2024Quote: ... Proteins were separated on a 4–20% pre-cast polyacrylamide gel (Biorad) by SDS electrophoresis ...
-
bioRxiv - Molecular Biology 2024Quote: ... and protein bands were visualised using the Chemidoc imaging system (Bio-Rad). Primary antibodies used ...
-
bioRxiv - Biochemistry 2024Quote: ... separated proteins were transferred from the gel to nitrocellulose membranes (Bio-Rad), and the blots were blocked with Odyssey blocking buffer (LI-COR Biosciences ...
-
bioRxiv - Physiology 2024Quote: ... Equal amounts of protein were mixed with Laemmli sample buffer (Bio-Rad) and loaded onto a 4%–20% gradient SDS-polyacrylamide gel (Bio-Rad ...
-
bioRxiv - Genomics 2024Quote: ... Protein concentration was assessed with a Bradford assay (Biorad, Lunteren, The Netherlands). Each sample was loaded onto a 12% SDS-PAGE gel (Biorad) ...
-
bioRxiv - Cell Biology 2024Quote: ... the gel proteins were transferred to a 0.2 uM PVDF membrane (BioRad), at 300 mAmp constant by 2h with 20% methanol 0.1% SDS transfer buffer (Invitrogen) ...
-
bioRxiv - Cell Biology 2024Quote: ... Proteins were resolved on Criterion XT 12% Bis-Tris gels (BioRad 3450117) in XT MOPS Running buffer (BioRad 1610788) ...
-
Braf-mutant Schwann cells divert to a repair phenotype to induce congenital demyelinating neuropathybioRxiv - Developmental Biology 2024Quote: ... Protein concentration was quantified by the DCProtein assay II (Bio-Rad 5000112) using an EnSpire Multimode plate reader (PerkinElmer ...
-
bioRxiv - Immunology 2024Quote: ... protein stripes were transferred onto the polyvinylidene difluoride (PVDF) membranes (Bio-rad). Membranes were blocked in the blocking buffer (Beyotime Biotechnology) ...
-
bioRxiv - Cancer Biology 2024Quote: ... Proteins were detected through chemiluminescence (Clarity™ Western ECL Substrate; BioRad; #1705061) using Chemidoc™ Imaging System (BioRad ...
-
bioRxiv - Molecular Biology 2024Quote: ... for specific tardigrade proteins and anti-mouse Starbright 520 (12005867, Bio-Rad) for alpha-tubulin detection ...
-
bioRxiv - Microbiology 2024Quote: ... secreted proteins were separated on 4-15% gradient SDS-PAGE gels (BioRad), stained with GelCode Blue (Thermo ...
-
bioRxiv - Synthetic Biology 2021Quote: ... Protein concentration was determined using Bradford assay with bovine serum albumin (BSA; BioRad) as a standard.
-
bioRxiv - Cancer Biology 2021Quote: ... Protein concentration was determined using Bradford reagent (Bio-Rad Laboratories, Hercules, CA, USA). 30 μg of denatured proteins were separated by SDS-PAGE (Mini-PROTEAN TGX Gels 10% ...
-
bioRxiv - Neuroscience 2021Quote: ... Proteins were transferred to PVDF membranes (Trans-blot Turbo Transfer Pack, Bio-Rad) using the Trans-blot Turbo Transfer System (Bio-Rad ...
-
bioRxiv - Cancer Biology 2021Quote: ... then incubated with protein A/G magnetic beads (Bio-Rad SureBeads Cat# 1614023) for 1 hour ...
-
bioRxiv - Cancer Biology 2021Quote: ... The protein concentration was measured using the BioRad Reagent (BioRad, Hercules, CA, USA). Cultured cells were rinsed twice with ice-cold HBSS ...
-
bioRxiv - Molecular Biology 2020Quote: ... the protein concentration of the supernatant was measured using the Bradford assay (BioRad) and ~150 μg of proteins for each condition were subjected to digestion ...
-
bioRxiv - Molecular Biology 2020Quote: Proteins samples were run on 4–20% Criterion TGX pre-cast gels (Biorad) in SDS/Tris-glycine running buffer and transferred to PVDF membranes by semi-dry trans-Blot Turbo system (Biorad) ...
-
bioRxiv - Immunology 2021Quote: ... the protein was transferred to a nitrocellulose membrane of 0.45 µm (BioRad Laboratories) at 100 V ...
-
bioRxiv - Developmental Biology 2021Quote: ... The protein concentration was estimated using the Bradford assay (Bio-Rad, Quick StartTM); 70µg total protein per sample was reduced with tris-2-carboxyethyl phosphine (TCEP ...
-
bioRxiv - Cell Biology 2020Quote: ... total proteins were separated and transferred into polyvinylidene fluoride (PVDF) membranes (Bio-Rad). After the block ...
-
bioRxiv - Cell Biology 2020Quote: For protein transfer a Trans-Blot Turbo Transfer System (Bio-Rad Laboratories, USA) was used ...
-
bioRxiv - Cell Biology 2019Quote: ... The 6XHis-TEV-Ypk1 fusion protein was coupled to Affigel 10 (Bio-Rad) to create an affinity column for purification of the antibody.
-
bioRxiv - Cell Biology 2019Quote: Protein samples were resolved on 4-20 % SDS-gradient gels (BioRad, Hercules, CA), then transferred to PVDF-FL membrane (Millipore Burlington ...
-
bioRxiv - Cell Biology 2019Quote: ... Quantification of protein expression was performed using the Image lab Software (Bio-Rad). Data were normalized with reference to the densitometry analysis of GAPDH.
-
bioRxiv - Cell Biology 2020Quote: Protein samples were resolved on 10% Criterion Tris-HCl precast gels (Biorad, #3450011) or in the case of the phosphorylated species of Arpp19 and ENSA on a 10% Tris-HCl SDS-PAGE supplemented with 10 μM Phos-tag reagent (NARD Institute ...
-
bioRxiv - Immunology 2021Quote: ... The proteins were separated by 10% Tris-HCl gel(Bio-Rad, CA, USA) and transferred to the polyvinylidene fluoride (PVDF ...
-
bioRxiv - Genetics 2021Quote: ... equal amounts of total protein (35μg) were combined with Laemmli sample buffer (BioRad) and denatured for 5 min at 95°C.
-
bioRxiv - Microbiology 2021Quote: ... proteins were transferred onto nitrocellulose membranes using Trans-Blot Turbo Transfer (Bio-Rad). Membranes were immunoblotted with custom-made anti-VgrG1 antibodies 31 at 1:1000 dilution ...
-
bioRxiv - Genetics 2020Quote: ... proteins were eluted in SDS sample buffer with 10% 2-Mercaptoethanol (Bio-Rad), separated on SDS-PAGE ...
-
bioRxiv - Neuroscience 2021Quote: ... Concentrated protein samples (10-20μg) were separated on 7.5% or 4-15% (BioRad) SDS-PAGE gels ...
-
bioRxiv - Evolutionary Biology 2020Quote: ... Total protein was resolved by Mini-PROTEAN GTX polyacrylamide gel electrophoresis (Bio-rad). Proteins were detected using anti-HA (Covance cat# MMS-101P ...
-
bioRxiv - Microbiology 2021Quote: ... Protein melt was performed using a CFX Connect Real-Time System (Bio-Rad) ramping from 20–95°C over 2 h ...
-
bioRxiv - Immunology 2021Quote: ... Densitometric quantification of detected protein bands was done with Quantity one software (Biorad).
-
bioRxiv - Microbiology 2021Quote: ... We determined the protein concentrations of thawed samples by Bradford assay (Bio-Rad) of 5 µl aliquots ...
-
bioRxiv - Developmental Biology 2020Quote: ... Proteins were separated by 14% SDS-PAGE and transferred to PVDF membranes (Biorad). Following blocking in 5% Milk (Sigma ...
-
bioRxiv - Developmental Biology 2020Quote: ... Proteins were transferred onto PVDF membranes (TransBlot Turbo Mini PVDF Transfer Packs, BIORAD) using a Trans-Blot Turbo Transfer System (BIORAD) ...
-
bioRxiv - Biochemistry 2022Quote: ... Protein concentration was quantified using the QuickStart Bradford 1X Dye Reagent (Biorad, 5000205). 150 μL of nanobody-coupled beads were washed in 1 mL of PBS for 5 minutes ...
-
bioRxiv - Biochemistry 2022Quote: ... The protein was run alongside Precision plus Kaleidoscope prestained standards (Bio-Rad #1610375) for 100 minutes at 100 V (Invitrogen mini gel talk A25977) ...
-
bioRxiv - Biochemistry 2022Quote: ... All proteins were purified on NGC chromatography systems (Bio-Rad Laboratories, Hercules CA) using immobilized metal affinity chromatography (IMAC ...
-
bioRxiv - Neuroscience 2021Quote: ... Protein samples (20 µg) were then mixed with 2x Laemmli buffer (Bio-Rad) before being loaded onto 10% tris-glycine gels and separated for 1 h at 150 V by SDS-PAGE ...
-
bioRxiv - Molecular Biology 2020Quote: ... 10 µg of protein from each sample was denaturated in Laemmli buffer (BioRad) containing 7% β-mercaptoethanol ...
-
bioRxiv - Neuroscience 2020Quote: Twenty microgram protein was loaded into AnykD Mini-PROTEAN gel (#4569035, BIO-RAD). After blocking ...
-
bioRxiv - Molecular Biology 2020Quote: ... The protein bands were transferred to a nitrocellulose membrane (Bio-Rad, CA, USA), blocked in 3% BSA in PBS for 1 hours and then incubated with primary antibody (anti-AGO2 antibody (1:1000) ...
-
bioRxiv - Molecular Biology 2020Quote: ... proteins were resolved in a 4-15% Mini-PROTEAN TGX Precast Gels (BioRad), and transferred to a PVDF membrane using Trans-Blot Turbo Mini PVDF Transfer Packs (BioRad ...