Labshake search
Citations for Bio-Rad :
101 - 150 of 10000+ citations for Glutathione Colorimetric Detection Kit 4 Plate since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biochemistry 2022Quote: Enhanced chemiluminescence (ECL) detection was performed using reagents from Biorad (Clarity Western ECL kit) and revealed using ChemiDocMPSystem (BioRad ...
-
bioRxiv - Pathology 2020Quote: ... The blots were developed using ECL immunochemical detection kit (Bio-Rad, Richmond, CA, USA) and densitometric analysis was conducted to quantify the Western blot immunoreactivity with a scanner and ImageQuant software (Amersham Biosciences ...
-
bioRxiv - Microbiology 2020Quote: ... the protein signals were detected using the ECL detection kit (Bio-Rad, California, USA). Blots were analyzed using Quantity One software (Bio-Rad ...
-
bioRxiv - Microbiology 2021Quote: ... the membrane was visualized using the ECL Western Blotting Detection Kit (Bio-Rad, USA).
-
bioRxiv - Microbiology 2021Quote: ... The autoradiography signals were visualized using ECL advance Western blotting detection kit (BioRad, USA).
-
bioRxiv - Neuroscience 2022Quote: ... Chemiluminescence detection was performed using Immun-Star WesternC Kit (Bio-Rad, Hercules, CA, USA), and the net intensities of each signal were quantified using ChemiDoc Imaging Systems (Bio-Rad).
-
bioRxiv - Biochemistry 2022Quote: ... The qPCR reactions were carried out in a 96-well plate in CFX96 Real-time PCR Detection System (Bio-Rad). The primers were listed in Table 1 ...
-
bioRxiv - Animal Behavior and Cognition 2021Quote: ... We ran samples in duplicate for each gene on the same 384-well plate using a CFX384 Touch Real-time PCR detection system (BioRad). We validated all primers for this study by running a 10-fold serial dilution to determine amplification efficiencies (average ...
-
bioRxiv - Bioengineering 2022Quote: Plate RT-PCR assays were performed with the same temperature conditions on a CFX96 Real-Time PCR Detection System (BioRad) or an Applied Biosystems QuantStudio 3 (ThermoFisher ...
-
bioRxiv - Microbiology 2023Quote: ... PCR plates were then sealed and amplification was carried out with the CFX96 Touch Real-Time PCR Detection System thermocycler (BioRad) following a thermal program of continuous 65°C with fluorescence read every 30 s for 180 cycles ...
-
bioRxiv - Immunology 2020Quote: ... and 5 mM glutathione (EMD) in a Gene Pulser Xcell (Bio-Rad Laboratories), with the following settings ...
-
bioRxiv - Cell Biology 2023Quote: ... Signal detection was performed by an enhanced chemiluminescence detection reagent (Bio-Rad). Approximate molecular masses were determined by comparison with the migration of prestained protein standards (Bio-Rad) ...
-
bioRxiv - Developmental Biology 2021Quote: ... The amount of total protein was measured with Lowry colorimetric assay (DC, Bio-Rad) for fat bodies and Bradford standard assay (Bio-Rad 500-0006 ...
-
bioRxiv - Systems Biology 2022Quote: ... Total protein concentrations were determined using a detergent-compatible colorimetric protein assay (DCA, BioRad).
-
bioRxiv - Neuroscience 2021Quote: ... Samples were analyzed in triplicate using a 384 well plate and captured in real-time using a PCR detection system (BioRad CFX384).
-
bioRxiv - Biochemistry 2021Quote: Fragment screening was carried out in a 96-well PCR plate using a CFX Connect Real-time PCR Detection System (Bio-Rad) for DSF ...
-
bioRxiv - Cancer Biology 2020Quote: ... Amplification reactions were performed in duplicate using 96 well-plates using a CFX96 Touch Real-time PCR Detection System (Bio-Rad).
-
bioRxiv - Cancer Biology 2021Quote: ... qPCR reactions were set up in triplicate in a 384-well plate and run on the CFX384 Touch Real-Time PCR Detection System (Bio-Rad). Each reaction contained 5μL of PerfeCTa SYBR Green FastMix (Quantabio ...
-
bioRxiv - Immunology 2020Quote: ... Real-time PCRs were performed in 96-well plates using the PrecisionPLUS qPCR Mater Mix (Primer Design) and the CFX96 Touch Real-Time PCR Detection System (BIO-RAD). The Affymetrix Human Transcriptome Array 2.0 (HTA2 ...
-
bioRxiv - Neuroscience 2019Quote: ... Reactions were run in triplicate on 96-well plates using a CFX96 Touch™ Real-Time PCR Detection System (Bio-Rad). Cycling conditions for qPCR reactions were as follows ...
-
bioRxiv - Microbiology 2021Quote: ... PCRs were performed on a CFX96 Touch Real-Time PCR Detection System using white Hard Shell 96-well PCR plates and Microseal ‘C’ Adhesive seals (Bio-Rad) or 0.2 mL white 8-tube PCR strips and optical caps (Bio-Rad) ...
-
bioRxiv - Microbiology 2022Quote: ... Reactions were 10 μL and conducted in 384-well plates using an annealing temperature of 60°C on a CFX384 Touch Real-Time PCR Detection System (Bio-Rad).
-
bioRxiv - Molecular Biology 2022Quote: ... All targets were amplified on the same 384well plate in one qPCR run on a CFX384 Touch Real-Time PCR Detection System (Bio-Rad), using three technical replicates per sample ...
-
bioRxiv - Cell Biology 2022Quote: ... PCR was carried out in 96-tube plates using the MyiQ Single Color Real-Time PCR Detection System and software (Bio-Rad). All reactions were done in triplicate with negative controls ...
-
bioRxiv - Microbiology 2023Quote: ... PCR was performed in a 96-well standard (0.2mL) plate on a CFX96 Real-Time PCR Detection System (Bio-Rad Laboratories). Expression patterns were revealed using the delta-delta Ct method with SmsR1491 or SmsR847 as the normalization gene.
-
bioRxiv - Plant Biology 2023Quote: RT-qPCR was performed in 96-well plates using the CFX96 real-time PCR detection system (Bio-Rad, Hercules, CA, USA). Six biological replicates were used from each treatment and each qPCR run used three technical replicates of each sample (i.e. ...
-
bioRxiv - Plant Biology 2023Quote: ... were pipetted in a 96 well plate and qPCR was performed with two technical duplicates with the CFX96 TouchTM Real-Time PCR Detection System (Bio-Rad). qPCR data were analyzed ...
-
bioRxiv - Bioengineering 2019Quote: ... Chemiluminescent detection of the HRP-conjugates was performed with the ‘Clarity Western ECL’ kit (Biorad), using ChemiDoc XRS system (Biorad ...
-
bioRxiv - Microbiology 2021Quote: ... the membrane was visualized using the ECL Western Blotting Detection Kit (Bio-Rad, United States).
-
bioRxiv - Cancer Biology 2020Quote: ... The antigen/antibody target signals were detected using an enhanced chemiluminescent detection kit (ECL-BioRad) and chemoluminescent detection using BioRad VersaDoc molecular imager and Software ...
-
bioRxiv - Microbiology 2023Quote: ... Signals were detected using enhanced chemiluminescence detection kits Clarity and Clarity Max ECL (Bio-Rad) followed by quantitation of bands intensities using the ImageJ software (National Institutes of Health ...
-
bioRxiv - Physiology 2024Quote: ... Enhanced chemiluminescence was performed with the ECL Western-Blot detection kit (Bio-Rad, California, USA) and videoacquisition (ChemiDoc™ XRS+ System ...
-
bioRxiv - Cell Biology 2024Quote: ... ECL detection was performed using the Clarity Western ECL Substrate kit from Biorad (170-5061) and chemiluminescence imaging was completed with an Amersham™ ImageQuant 800 Fluor ...
-
bioRxiv - Neuroscience 2021Quote: ... for detection by Biorad ChemiDoc MP camera (Bio-Rad Laboratories ...
-
bioRxiv - Neuroscience 2022Quote: ... chemiluminescent detection reagents (BioRad) were used according to company instructions ...
-
bioRxiv - Microbiology 2021Quote: ... Plates were then blocked with a 4% (w/v) solution of dried milk powder (BioRad) in TBS with 0.05% (v/v ...
-
bioRxiv - Microbiology 2023Quote: ... Plates were then blocked with 150 μl of 4% w/v nonfat milk (Bio-Rad) for 1 h ...
-
Osh6 requires Ist2 for localization to the ER-PM contacts and efficient phosphatidylserine transportbioRxiv - Cell Biology 2020Quote: ... 1.5 μl for bound franction for GFP detection) were loaded on SDS–PAGE (4-20% Mini-PROTEAN TGX Stain-Free, Bio-Rad) and analyzed by Western blot.
-
bioRxiv - Developmental Biology 2020Quote: ... excess antibody subsequently removed by a further 4 washes in TBSTw for 5 minutes before detection with ECL Western blotting reagent (Bio-Rad) following manufacturer’s instructions ...
-
bioRxiv - Cell Biology 2021Quote: ... The concentration of purified proteins was determined by colorimetric assay (Bio-Rad DC Protein Assay) and verified by electrophoresis alongside of BSA standards with Coomassie staining.
-
bioRxiv - Systems Biology 2021Quote: ... Protein concentrations of the Hgb-reduced samples were measured by Bradford colorimetric assay (Bio-Rad) prior to biochemical fractionation.
-
bioRxiv - Cell Biology 2022Quote: ... The absorbance of colorimetric product formazan was recorded using a microplate reader (Bio-Rad, Switzerland) at 490 nm with a reference wavelength of 630 nm ...
-
bioRxiv - Evolutionary Biology 2022Quote: ... Protein concentrations in supernatants were estimated using the DC colorimetric protein assay (Bio-Rad Laboratories) with a standard curve derived using differing concentrations of BSA ...
-
bioRxiv - Cell Biology 2023Quote: Protein concentration was assayed by using a colorimetric Bradford assay (Bio-Rad, Hercules, CA, USA). Western blotting was performed essentially as previously described (Spencer et al. ...
-
bioRxiv - Microbiology 2020Quote: ... The membranes were visualized using the chemiluminescence detection kit Clarity ECL Western Blotting Substrates (Bio-Rad) in an Alliance Q9 Advanced machine (Uvitec).
-
bioRxiv - Microbiology 2023Quote: ... Bands were detected using the enhanced chemiluminescence detection kits Clarity and Clarity Max ECL (Bio-Rad).
-
bioRxiv - Microbiology 2020Quote: ... Single cells were sorted into 16 × 24 matrices onto URISelect™ 4 agar plates (Bio-Rad) prepared in Nunc™ OmniTray™ Single-Well Plates (Thermo Scientific) ...
-
Checkpoint adaptation in repair-deficient cells drives aneuploidy and resistance to genotoxic agentsbioRxiv - Cell Biology 2019Quote: ... using 7.5 % polyacrylamide gels for Rad53 detection or a gradient of 4-15 % polyacrylamide for all other proteins in Mini-PROTEAN® electrophoresis chambers (Bio-Rad). Proteins were transferred to 0.45 µm pore size nitrocellulose membranes (GE Healthcare ...
-
bioRxiv - Physiology 2024Quote: ... were used for real-time PCR with gene-specific primers (Supplementary Table 4) and Tbp as a housekeeping gene on a CFX96™ Real-Time PCR Detection System (Bio-Rad).
-
bioRxiv - Microbiology 2021Quote: All melt-MAMA PCRs were performed on a CFX96 Real-Time PCR Detection System using white hard shell 96-well PCR plates or 0.2 mL 8-tube PCR strips (Bio-Rad, Gladesville, NSW, Australia), and PCR results examined using the CFX Maestro v4.1.2433.1219 software (Bio-Rad) ...