bioRxiv - Plant Biology 2020Quote: ... All samples were transferred to Nitrocellulose membrane with the Trans-Blot Turbo RTA transfer kit (BIO-RAD Cat.#170-4270). The chemiluminescent signal was detected with Immobilon Western Chemiluminescent HRP Substrate (Millipore ...
-
bioRxiv - Evolutionary Biology 2020Quote: ... the membrane was washed three times with TBST and detection was performed with the Clarity™ ECL kit (Bio-Rad) according to the manufacturer’s instructions and visualized with a CCD camera of the Odyssey Fc imaging system (Li-COR Biosciences ...
-
bioRxiv - Cell Biology 2021Quote: ... The membrane was developed by using ECL prime western blotting detection kit (Amersham) and images were captured using Versadoc (Biorad).
-
bioRxiv - Cancer Biology 2022Quote: Protein separations were transferred onto a nitrocellulose membrane using the Trans-blot Turbo RTA transfer kit (Bio-rad, #170-4270) according to manufacturer’s protocol ...
-
bioRxiv - Neuroscience 2021Quote: ... Proteins were transferred onto a nitrocellulose membrane using Trans-Blot® Turbo™ RTA Midi Nitrocellulose Transfer Kit (Bio-Rad) in the Trans-Blot® Turbo™ Transfer System (Bio-Rad) ...
-
bioRxiv - Plant Biology 2021Quote: ... proteins from SDS-PAGE gels were transferred onto nitrocellulose membranes using the Transblot Turbo RTA Midi Transfer kit (BioRad, USA). Mouse anti-α-tubulin antibody (Sigma-Aldrich ...
-
bioRxiv - Biochemistry 2021Quote: ... Proteins were then transferred to PVDF membranes using Trans-Blot Turbo RTA Mini 0.45 mM LF PVDF Transfer Kit (Bio-Rad), and blotted with anti-HA antibody ...
-
bioRxiv - Synthetic Biology 2021Quote: ... Protein transfer to the PVDF membrane was performed following manufacturer’s instructions for the membrane kit (Trans-Blot Turbo Midi 0.2 μm PVDF, 1704157, BioRad, Hercules, CA) and the transfer apparatus (Trans-Blot® Turbo™ Transfer System ...
-
bioRxiv - Pathology 2023Quote: ... Proteins were resolved on 4-15% SDS-PAGE gels and transferred to nitrocellulose membrane (Trans-Blot Turbo RTA transfer kit, #1704271, Biorad). Membranes were blocked for 1h at room temperature in 5%BSA-TBS-T (TBS-0.1%Tween 20 ...
-
bioRxiv - Pathology 2023Quote: ... Proteins were resolved on 4-15% SDS-PAGE gels and transferred to nitrocellulose membrane (Trans-Blot Turbo RTA transfer kit, #1704271, Biorad). Membranes were blocked for 1h at room temperature in 5% BSA-TBS-T (TBS-0.1%Tween 20 ...
-
bioRxiv - Cancer Biology 2023Quote: ... transferred to nitrocellulose membranes using semi-dry transfer apparatus and Tans-Blot Turbo RTA Midi Nitrocellulose Transfer kit (Bio-Rad). The membranes were then blocked with 3% milk in TBST ...
-
bioRxiv - Microbiology 2023Quote: ... Separated proteins were then transferred to a nitrocellulose membrane using a Trans-Blot Turbo RTA Mini 0.2 μm Nitrocellulose Transfer Kit and Trans-Blot Turbo system (Bio-Rad). The membrane was cut to separate the regions above and below approximately 70 kDa ...
-
bioRxiv - Cancer Biology 2024Quote: ... Proteins were transferred to a PVDF membrane using the Bio-Rad Turbo Transblot System and transfer kit (Bio-Rad Laboratories) and fixed in methanol prior to blocking in 5% non-fat milk in TNT buffer (50 mM Tris pH 8.0 ...
-
bioRxiv - Cell Biology 2023Quote: ... All gels were transferred to PVDF membranes using Trans-Blot Turbo RTA Mini LF PVDF Transfer Kits (Bio-Rad, 1704274).
-
bioRxiv - Bioengineering 2024Quote: ... Protein separations were transferred onto a nitrocellulose membrane using the Trans-blot Turbo RTA transfer kit (Bio-rad, #170-4270) according to the manufacturer’s protocol ...
-
bioRxiv - Microbiology 2023Quote: ... Proteins were transferred to PVDF membranes using a Trans-Blot Turbo RTA Mini 0.2 µm PVDF Transfer Kit (Bio-Rad) according to the manufacturer’s instructions ...
-
bioRxiv - Biophysics 2023Quote: ... proteins were transferred to PVDF membranes using a Trans-Blot Turbo RTA Mini 0.2 μm PVDF Transfer Kit (Bio-Rad) according to the manufacturer’s instructions ...
-
bioRxiv - Developmental Biology 2023Quote: ... Membrane strips were finally washed 6x for 3mins in 1X TBST before being developed with the ECL Clarity Kit (BioRad) and imaged on ChemiDoc Imaging system (BioRad) ...
-
bioRxiv - Genomics 2022Quote: ... After incubation with HRP-coupled secondary antibody diluted in saturation buffer (1 h, room temperature), membranes were revelated using ECL kit (Pierce, 34076) on Chemidoc XRS+ imager (Biorad). Images were processed and analyzed using ImageJ software ...
-
bioRxiv - Cancer Biology 2024Quote: ... were transferred to a 0.45μM nitrocellulose membrane (Trans-Blot Turbo RTA Transfer kit nitrocellulose midi #1704271) using Trans-Blot Turbo Transfer System (Bio-Rad #1704150 ...
-
bioRxiv - Molecular Biology 2024Quote: ... The protein was then transferred to a nitrocellulose membrane using the Trans-Blot Turbo Transfer kit (Bio-Rad, 170-4270) with standard transfer settings (25V ...
-
bioRxiv - Molecular Biology 2024Quote: ... The washed membrane was detected using the Clarity Western ECL kit following manufacturer protocol and imaged using a ChemiDoc XRS+ apparatus (BioRad). Pixel density for each dot was quantified using the volume tool in ImageLabTM software (BioRad).
-
bioRxiv - Molecular Biology 2024Quote: ... Boston, USA) diluted 1:10,000 (16, 17, 73) on a nitrocellulose membrane using the Bio-Dot Microfiltration kit (Bio-Rad). Bound antibodies were detected with a peroxidase-conjugated Goat anti-rabbit immunoglobulin G (IgG ...
-
bioRxiv - Microbiology 2020Quote: ... Protein concentrations were determined with the Quick Start™ Bradford Protein Assay kit (Bio-Rad Laboratories, Hercules, CA) using a concentration series of bovine serum albumin solution as standards.
-
bioRxiv - Immunology 2021Quote: ... The supernatant was collected and protein concentration quantified using a Bio-Rad protein assay kit (BioRad Laboratories, USA) and later stored at -80°C until use.
-
bioRxiv - Microbiology 2020Quote: ... quantitative real-time RT-PCR assays were performed using the iTaq SYBR Green One-Step Kit (Bio-Rad) on the LightCycler 480 system (Roche ...
-
bioRxiv - Biophysics 2021Quote: ... The total protein per sample was determined via the BCA protein assay standards kit (Biorad, Cat# 500-0006) and used to correct for varying protein content within the cell supernatant ...
-
bioRxiv - Microbiology 2022Quote: ... The supernatant protein concentrations were determined using the Coomassie brilliant blue G-250 Protein Assay kit (Bio-Rad), with BSA serving as the standard ...
-
bioRxiv - Pathology 2021Quote: Cytokine levels were measured in blood serum samples by using the Bio-Plex Pro assay kit (Bio-Rad) according to manufacturer’s instructions ...
-
bioRxiv - Microbiology 2021Quote: ... quantitative real-time RT-PCR assays were performed using the iTaq SYBR Green One-Step Kit (Bio-Rad) on the LightCycler 480 system (Roche ...
-
bioRxiv - Cell Biology 2022Quote: ... Protein concentration was then determined by using a DC™ Protein Assay Reagent kit (Cat. 5000122, Bio-RAD). Samples were then normalized with the Cell Lysis Buffer based on the protein concentration ...
-
bioRxiv - Synthetic Biology 2020Quote: ... the concentration of purified scCro was determined using the Quick Start™ Bradford Protein Assay Kit (Bio-Rad) and the sample was stored at -25 °C (Figure S3).
-
bioRxiv - Biochemistry 2020Quote: ... Purified proteins were supplemented in 50% glycerol and were quantified using the Bradford protein assay kit (Bio-Rad). Proteins were aliquoted and stored at −80°C until needed ...
-
bioRxiv - Cancer Biology 2020Quote: ... The quantity of protein extracted was measured with a DC protein assay kit (Bio-Rad, Hercules, CA, USA). 2-4 μg of protein were separated by western blot analysis as described previously.
-
bioRxiv - Immunology 2020Quote: ... The protein concentration was determined using Bio-Rad RC DC Protein Assay Kit (Bio-Rad No. 500-0119) according to manufacturer’s protocol ...
-
bioRxiv - Microbiology 2021Quote: ... a quantitative RT-PCR assay was conducted using an iTaq Universal SYBR Green one-step kit (Bio-Rad) on a QuantStudio 7 Flex Real-Time PCR Systems (Thermo fisher ...
-
bioRxiv - Neuroscience 2022Quote: ... After obtaining the brain and Neuro2A lysates we measure protein concentration (DC™ Protein Assay Kit II, Biorad) and samples were used in subsequent experiments.
-
bioRxiv - Molecular Biology 2023Quote: ... Total protein content of cell free BALF was determined using the DC Protein Assay Kit (Cat 5000111; BioRAD, Inc ...
-
bioRxiv - Cancer Biology 2023Quote: ... and protein concentrations determined using a Bio-Rad DC Protein assay kit (Bio-Rad, #500-0113, -0114, -0115). Protein concentrations were equalized with ddH2O ...
-
bioRxiv - Plant Biology 2023Quote: ... The supernatant was collected and protein content was measured with a commercially available assay kit (Bio-Rad, Inc.) using bovine serum albumin as a standard ...
-
bioRxiv - Molecular Biology 2023Quote: ... and protein concentration was determined using the DC Protein Assay Kit (500-0116, Bio-Rad, Hercules, CA, USA) following the manufacturer’s instructions ...
-
bioRxiv - Neuroscience 2022Quote: ... and the protein concentrations of the lysates were quantitated using a DC Protein Assay II Kit (BioRad, 5000112.). Protein A Dynabeads (ThermoFisher ...
-
bioRxiv - Neuroscience 2022Quote: ... and the protein concentration was measured using the Quick Start Bradford Protein Assay Kit 1 (Bio-Rad 5000201) in a Tecan Infinite F200 PRO spectrophotometer ...
-
bioRxiv - Neuroscience 2022Quote: ... Following measurement of the protein concentration using the Quick Start Bradford Protein Assay Kit 1 (Bio-Rad 5000201) in a Tecan Infinite F200 PRO spectrophotometer ...
-
bioRxiv - Pharmacology and Toxicology 2024Quote: ... the protein concentration of the supernatants was determined using a DC protein assay kit (Bio-Rad Laboratories, CA). Samples (10-15 μg total protein ...
-
bioRxiv - Cell Biology 2023Quote: ... the supernatant protein extract was collected and protein concentration was determined using DC Protein Assay Kit (Bio-Rad).
-
bioRxiv - Systems Biology 2024Quote: ... protein quantitation was performed using the Bio-Rad Protein assay kit II (Bio-Rad Laboratories, Hercules, United State) and peptide quantitation was performed using the Pierce™ Quantitative Peptide Assays & Standards (Thermo Fisher Scientific ...
-
bioRxiv - Neuroscience 2023Quote: Total protein concentration for each sample was determined using the DC Protein Assay kit (BioRad, Inc.; Hercules, CA) according to the manufacturer’s protocol ...
-
bioRxiv - Plant Biology 2022Quote: ... Protein concentration of the samples was measured using Bradford Protein Assay Kit (Bio-Rad Laboratories Inc., California, U.S.A.).
-
bioRxiv - Microbiology 2022Quote: ... Protein concentration was estimated by the Bradford assay using a commercial kit (Catalog no. 5000001; Bio-Rad, India). For the Western blot analysis ...