Labshake search
Citations for Bio-Rad :
651 - 700 of 763 citations for 3 3 Dimethyl 6 oxa 3 phosphoniabicyclo 3.1.0 hexane since 2020
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Cancer Biology 2024Quote: ... 1 x 10^6 cells were electroporated with RNPs in Gene Pulser electroporation buffer (#1652676, Bio-Rad, Hercules, CA) with electroporation enhancer (#1075915 ...
-
bioRxiv - Synthetic Biology 2024Quote: ... Imaging was performed using the Silver Stain setting on Image Gel 6 on Gel Doc EZ Imager (Bio-Rad). ImageJ software was used for band intensity quantification as described below.
-
bioRxiv - Biophysics 2021Quote: ... The uncoupled BG-GLA-NHS was removed by filtration on Micro Bio-Spin™ P-6 Gel Columns (Bio-Rad).
-
bioRxiv - Molecular Biology 2020Quote: ... approximately 250.000 cells were plated in a 6-well dish and transfected with a final concentration of 22.5 nM siRNA using siLentFect Lipid Reagent (Bio-Rad) accordingly to manufacturer’s protocol ...
-
bioRxiv - Biochemistry 2020Quote: ... MtCoaBC and MsCoaBC were exchanged into NH4OAc (500 mM, pH 7.0) solution using Micro Bio-Spin 6 chromatography columns (Bio-Rad). A sample volume of 2.5 μL was injected into a borosilicate emitter (Thermo Scientific ...
-
bioRxiv - Molecular Biology 2020Quote: DNA isolated from cells by phenol:chloroform isolation and ethanol precipitation was cleaned on Micro Bio-Spin P-6 SSC columns (Bio-Rad) according to manufacturer protocol ...
-
bioRxiv - Plant Biology 2020Quote: ... Captured elution fraction from the Strep-Tactin-affinity purification were loaded onto a anion exchange column (UNO Q-6, Biorad) with a flowrate of 4 ml/min ...
-
bioRxiv - Biochemistry 2021Quote: ... pH 5.3 (murine P-domains) or pH 7.3 (GII.4 Saga P-domain) at 4 °C via Micro Bio-Spin 6 columns (Bio-Rad) according to the manufacturer’s protocol ...
-
bioRxiv - Biochemistry 2020Quote: ... and CyaY were buffer exchanged into 200 mM ammonium acetate (pH = 7.5) using Micro Bio-Spin 6 Columns (Bio-Rad). Instrument parameters were tuned to maximize transmission but simultaneously preserve the native-like state of proteins as determined by ion mobility ...
-
bioRxiv - Neuroscience 2020Quote: ... IL-6) were quantified using a real-time PCR detection system and SsoAdvanced Universal SYBR Green Supermix kit (BIO-RAD). In brief ...
-
bioRxiv - Biophysics 2020Quote: ... Fractions containing protein were pooled and desalted to remove imidazole by gel filtration on a 50 mL BioScale P-6 column (BioRad) using resuspension buffer as the eluant.
-
bioRxiv - Biochemistry 2020Quote: ... the cleaved His6 tag was removed and the enzymes were buffer exchanged into 200 mM ammonium acetate (pH 7.5) using Micro Bio-Spin 6 columns (Bio-Rad). His6-affinity tagged HalA2 was likewise digested with thrombin to remove the His6 tag ...
-
bioRxiv - Cancer Biology 2022Quote: Proteins were resolved in 6-8-10 or 12% polyacrilammide gels and transferred to PVDF (Bio-Rad, Hercules, CA,USA) or nitrocellulose membranes (GE Heath Care ...
-
bioRxiv - Biochemistry 2022Quote: ... the enzymes were buffer exchanged into their respective reaction buffers above using a Micro Bio-Spin 6 size exclusion spin column (Biorad) to remove glycerol and other ion suppressing constituents ...
-
bioRxiv - Microbiology 2022Quote: ... Proteins were transferred to PVDF membrane at 4°C for 14.5 h at 30 V using the mini trans-blot module in transblot buffer (10 mM MES buffer pH 6 and 10% (v/v) methanol) according to the supplier’s instructions (Bio-Rad). The membrane was removed from the cassette ...
-
bioRxiv - Biophysics 2021Quote: ... and 2 times the critical micelle concentration (CMC) of various detergents (namely LDAO and C8E4) using a Biospin-6 column (BioRad) and introduced directly into the mass spectrometer using gold-coated capillary needles (prepared in-house) ...
-
bioRxiv - Cell Biology 2020Quote: ... gossypii proteins) or TBS (S. cerevisiae proteins) supplemented with 1 mM DTT using pre-equilibrated BioSpin-6 spin columns (BioRad) or ...
-
bioRxiv - Systems Biology 2021Quote: ... and 6 μl for slow growing mutants with lower OD600) on Stain-Free gels (4-20%, CAT # 4568096, Bio-Rad, Tris/Glycine SDS Buffer (CAT # 161-0732 ...
-
bioRxiv - Microbiology 2021Quote: ... for 60 min at 37°C followed by purification on a Micro-Bio Spin P-6 Gel Column (Bio-Rad). 1 pmol of 5’-end-radiolabeled primer was used for each extension reaction ...
-
bioRxiv - Biochemistry 2021Quote: APRT2-Ntag and APRT2-Ctag were buffer exchanged into a volatile buffer (200 mM ammonium acetate, pH 7.4) using a Micro Bio-Spin 6 device (Bio-Rad). Samples were loaded into pulled glass capillaries prepared in house ...
-
bioRxiv - Immunology 2021Quote: ... before buffer exchange into 500 mM ammonium acetate solution (pH 7.5) using a Micro Bio-Spin 6 column (Bio-Rad).
-
bioRxiv - Biochemistry 2023Quote: ... CsgA and CsgAslowgo samples were buffer-exchanged into MS-compatible buffer (150 mM Ethylene diamine diacetate pH 6.3, 10mM TMAO) using Micro Biospin 6 desalting columns (Bio-Rad) to a final protein concentration of 3-5 μM ...
-
bioRxiv - Plant Biology 2023Quote: ... The binding reaction was resolved on a 6% polyacrylamide gel in 0.5X TBE (pH 8.0) buffer and was semi-dry blotted (Transblot, BIO-RAD, USA) onto a positively charged nylon membrane (BrightStar ...
-
bioRxiv - Molecular Biology 2024Quote: ... The binding reaction was resolved on a 6% polyacrylamide gel in 0.5X TBE buffer (pH 8.0) and was semi-dry blotted (Transblot, BIO-RAD, USA) onto a positively charged nylon membrane (BrightStar ...
-
bioRxiv - Cell Biology 2023Quote: ... For each sample 20 μg of K562 cell extracts were loaded on 6-18% hand-casted acrylamide SDS-PAGE gradient gel (40% Acrylamide/bis-Acrylamide solution, BioRad). After separation by electrophoretic run ...
-
bioRxiv - Biochemistry 2022Quote: ... were exchanged from size exclusion buffer into 2 M ammonium acetate pH 7.4 via a single-pass through a Bio-Spin P-6 column (Bio-Rad). Buffer-exchanged protein was loaded into gold-coated glass capillaries (1.0 mm OD/0.75 mm inner diameter with filament) ...
-
bioRxiv - Biochemistry 2023Quote: ... The oligomeric state of CsoSCA-MBP was determined from the Superose 6 Increase chromatogram and a calibration standard (Bio-Rad). Molecular weight of standard was as follows ...
-
bioRxiv - Cancer Biology 2024Quote: As previously described,(6) we used the Bio-Plex Pro Human Chemokine 40-plex Panel (Bio-Rad Laboratories, Hercules, California) on a Luminex 200 System to measure plasma cytokines ...
-
bioRxiv - Biochemistry 2024Quote: AcrAS was buffer exchanged into a volatile solution (100 mM ammonium acetate, pH 6.0) using a centrifugal exchange device (Micro Bio-Spin 6, Bio-Rad) according to manufacturer’s instructions native MS experiments were performed on a Synapt G2-Si mass spectrometer (Waters) ...
-
bioRxiv - Biochemistry 2024Quote: ... The gels were run at 6 W/gel and followed by Cy3 visualization using the Molecular Imager PharosFX system (BioRad).
-
bioRxiv - Biochemistry 2024Quote: Purified membrane proteins were buffer exchanged into 200 mM ammonium acetate (pH 7.4 at room temperature adjusted with ammonium hydroxide) supplemented with 2x CMC of the desired detergent using a centrifugal desalting column (Micro Bio-Spin 6 columns, BioRad). For the AmtB-GlnK complex ...
-
bioRxiv - Molecular Biology 2024Quote: ... 200 mM ammonium acetate at the desired pH using a centrifugal buffer exchange device (Micro Bio-Spin 6, Bio-Rad). Stock solutions of lipids were prepared from chloroform/methanol solution by evaporating aliquots of known volume in a SpeedVac ...
-
bioRxiv - Biochemistry 2024Quote: ... Purified GroEL and GroES were first buffer-exchanged into RNC low-salt buffer using Micro Bio-Spin 6 Columns (Biorad) to remove any traces of Tris-HCl ...
-
bioRxiv - Cancer Biology 2024Quote: Protein lysates were generated by sonicating and boiling 1*10^6 cells in 100ul of 2X Laemmli Buffer (Bio-Rad) with BME ...
-
bioRxiv - Biochemistry 2024Quote: ... The reaction products were resolved in a 15% UREA-PAGE gel and the 6-FAM signal from the RNA visualized in a ChemiDoc gel imager (BioRad).
-
bioRxiv - Genetics 2024Quote: ... was added to the reactions and the products were separated on 6% polyacrylamide gels (ratio acrylamide:bisacrylamide 19:1, Bio-Rad) in TAE (40mM Tris ...
-
bioRxiv - Molecular Biology 2020Quote: ... The deamination reaction was then carried out by incubating in a thermal cycler for four cycles of 5 minutes at 70°C followed by 1 hour at 60°C and then desalted with Micro Bio-spin 6 chromatography columns (Bio-Rad). RNA was desulphonated by adding an equal volume of 1 M Tris (pH 9.0 ...
-
bioRxiv - Molecular Biology 2020Quote: ... IB analysis was performed after 6-7.5% SDS-PAGE or 4-20% Mini-PROTEAN TGX Precast Protein Gels (BioRad, Hercules, CA), with overnight incubation with a 1:1000 dilution of primary antibody and followed by a 1:5000 dilution of horseradish peroxidase-conjugated anti-rabbit or anti-mouse antibody (Jackson ImmunoResearch ...
-
bioRxiv - Bioengineering 2020Quote: ... Equal volumes of 10 mg/L (GT)15- or (GT)6-Cy5-SWCNTs and 160 mg/L protein were added to a 96-well PCR plate (Bio-Rad) to a total volume of 50 μL ...
-
bioRxiv - Biophysics 2021Quote: ... beads were washed with wash buffer 6-8 times in poly-prep chromatography columns (cat. no. 7311550, BIO-RAD laboratories Inc). Protein was eluted using Ni-NTA elution buffer (50□mM NaPi pH 7.6 ...
-
bioRxiv - Cancer Biology 2020Quote: ... Samples (20 µg/lane) were electrophoresed on a 6–12% SDS polyacrylamide gel in a Mini-PROTEAN Tetra Cell (Bio-Rad) and subsequently transferred to a nitrocellulose membrane (Sartorius AG ...
-
bioRxiv - Cell Biology 2021Quote: ... as previously described 58 and a custom Bio-Rad 6-plex based on the Human Inflammation Panel 1 (BioRad, Cat# 171AL001M). For both assays ...
-
bioRxiv - Cell Biology 2021Quote: ... inside an anaerobic glove-box and the excess DTT was completely removed via a Bio-Gel P-6 DG gel-desalting column (Bio-Rad) in thoroughly de-oxygenated MOPS buffer (20 mM ...
-
bioRxiv - Biophysics 2021Quote: ... DIV15-30 neurons were transfected 2-6 days before imaging via biolistic gene transfer (160 psi, Helios gene gun, Bio-Rad), as described in a detailed video protocol (Woods and Zito 2008) ...
-
bioRxiv - Biochemistry 2022Quote: ... and purified by vertical gel electrophoresis on a 6% (60:1 Acrylamide/Bisacrylamide) native gel column using a 491 Prep Cell (Bio-rad) run at 10W and 4°C ...
-
bioRxiv - Pharmacology and Toxicology 2020Quote: ... were then generated using the piggyBac transposon system as described.12 Protein expression was induced with doxycycline and secreted fusion protein was separated from expression media using IgG Sepharose 6 Fast Flow resin (GE-Healthcare) in a 10 mL Poly-Prep chromatography column (Bio-Rad). Resin was washed with 50 column volumes of wash buffer (10 mM Tris pH 7.5 ...
-
bioRxiv - Immunology 2020Quote: ... The concentrations of mouse and human IL-6 and TNF-α were determined by a multiplex Bio-Plex assay (Bio-Rad) according to the manufacturer’s instructions ...
-
bioRxiv - Microbiology 2021Quote: ... cells were infected with SINV at an MOI of 2 and pictures were taken 6 hours post-infection using ZOE fluorescent cell imager (Bio-Rad). Proteins were collected with lysis buffer (50 mM Tris-HCl pH 7.5 ...
-
bioRxiv - Biochemistry 2021Quote: ... was incubated at 55°C for 2 h and then purified by 6% non-denaturing PAGE using a Prep Cell apparatus (Bio-Rad).
-
bioRxiv - Microbiology 2020Quote: ... Membranes were dried out at RT and then exposed to a phosphoscreen cassette (GE) for 6 days for further scanning in a phosphoimager analyzer (Bio-Rad).