Labshake search
Citations for World Precision Instruments :
401 - 426 of 426 citations for Trans Dcca 100 Ug Ml In Acetonitrile D3 1 Carboxyl 13C2 99%;1 D 97% 97% Chemical Purity since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2022Quote: ... was injected at .12μL/min just below the dorsal CA1 pyramidal layer (−3.6 AP, 2.5 ML, 2.6 DV) via a 10uL Nanofil syringe (World Precision Instruments) mounted in a Quintessential Stereotaxic Injector (Stoelting ...
-
bioRxiv - Neuroscience 2022Quote: ... Bilateral burr holes were made at -2.2 mm (AP) and +/-1.3 (ML) using a 0.5mm drill to allow a 10uL nanofil syringe (World Precision Instruments) to be lowered to 2.0 mm (DV) ...
-
bioRxiv - Developmental Biology 2023Quote: ... Isolated brains were transferred to a drop of Fibrinogen dissolved in Schneider’s medium (101lmg/ml) on a 231lmm Glass bottom dish (WPI), which was then clotted by addition of Thrombin (1001lU/ml ...
-
bioRxiv - Neuroscience 2023Quote: ... by 2.5 mm (medial-lateral; ML) was made over the right SC using a high-speed surgical drill (OmniDrill35, WPI) with a 0.4 mm ball-tip carbide bur (Meisinger) ...
-
bioRxiv - Neuroscience 2023Quote: ... was injected at .12uL/min just below the dorsal CA1 pyramidal layer (−3.6 AP, 2.5 ML, 2.6 DV) via a 10uL Nanofil syringe (World Precision Instruments) mounted in a Quintessential Stereotaxic Injector (Stoelting ...
-
bioRxiv - Neuroscience 2019Quote: ... AAVs were injected into the somatosensory cortex (AP: −4.5, ML: +2.0) using a glass pipette and micropump (World Precision Instruments). AAVs were targeted to both layer V neurons (DV ...
-
bioRxiv - Neuroscience 2019Quote: ... 2 CaCl2.2H2O at a rate of 2 ml/min using a perfusion pump (PeriStar Pro; World Precision Instruments, Sarasota, FL). For current clamp recordings of intrinsic membrane properties and current-injected firing ...
-
bioRxiv - Neuroscience 2020Quote: ... Approximately 2.2μl of virus (1.12 × 1013 genomic counts per ml) was injected into the vitreous of each eye using a Nanofil 10μl syringe (World Precision Instruments) using 35-gauge bevelled needle using a surgical microscope (M620 F20 ...
-
bioRxiv - Neuroscience 2021Quote: ... +/−2.6mm ML, −4.5mm DV) using a 10μL syringe (nanofil, World Precision Instrument, USA) with NanoFil Needle (NF33BV-2, World Precision Instruments, USA) at a rate of 100nL/min (Micro4 pump ...
-
bioRxiv - Cell Biology 2021Quote: ... larvae were anesthetized with 0.2 mg/mL Tricaine in E3 and positioned dorsally against the side of grooves made by a mold (World Precision Instruments) in 1% low-melt agarose.
-
bioRxiv - Neuroscience 2022Quote: ... 500nl AAV9-hSyn-OT1.0 or AAV9-hSyn-OTmut viruses were delivered into the BNST (AP: −0.45 mm, ML: −0.9 mm, DV: −3.6 mm) through a glass capillary using nanoinjector (World Precision Instruments, Nanoliter 2000). After virus injection ...
-
bioRxiv - Physiology 2022Quote: ... and muscle relaxant (0.5 mg/ml) (Nimbex, Apsen) at 20 μl per minute via syringe pumps (AL-1000, World Precision Instruments). A slightly larger polyethylene tube (PP50 ...
-
bioRxiv - Neuroscience 2023Quote: ... and rAAV5-EF1α-DIO-ChR2(H134R)-EYFP (3.2 x 1012 VM/mL) were unilaterally administered into the right side of the VMH of mice using a UMP3 UltraMicroPump (WPI, US) with 10 µL NanoFil microsyringe (WPI ...
-
bioRxiv - Biochemistry 2023Quote: ... the injection of 1 µl of 2.5e12 GC/ml AAV9 in PBS was delivered at 125 nl/min using a micropump-controlled syringe (NanoFil, World Precision Instruments). After the injection completed ...
-
bioRxiv - Neuroscience 2024Quote: ... were injected bilaterally into the NAc core (AP: +1.6; ML: ±1.8; DV: -6.8) (Paxinos & Watson, 1986) using a micro-injection pump (World Precision Instruments, Sarasota, FL) after a 2-min wait period once syringe tips reached the region of interest ...
-
bioRxiv - Cell Biology 2021Quote: ... were resuspended in 2–3 mg/ml rat-tail collagen I in RM+ medium and seeded on 23-mm FluoroDish cell culture dishes (World Precision Instruments). The collagen with embedded cells was allowed to set at 37°C until collagen contraction was observed (∼30 min) ...
-
bioRxiv - Neuroscience 2021Quote: ... ± 1.3 mm ML relative to Bregma) which was subsequently protected by a customized synthetic window filled with Kwik-Cast sealant (World Precision Instruments). After recovery from anesthesia ...
-
bioRxiv - Neuroscience 2021Quote: ... 40 nl of one of the viral vectors listed above at a titer of 2*1012 particles/ml was injected per site (PMd, amv dlPAG) using a 10 μl nanofil syringe (World Precision Instruments) at 0.08 μl/min ...
-
bioRxiv - Neuroscience 2023Quote: ... The spout was connected by tubing to a 10 ml syringe filled with water and secured in a single-syringe infusion pump (AL-1000, World Precision Instruments). The pump was located outside of the box ...
-
bioRxiv - Physiology 2023Quote: ... Excess adipose tissue was manually cleaned from the muscles and tendons were tied with a braided silk thread and mounted in a 15 mL stimulation chamber between a force transducer and an adjustable holder (World Precision Instruments). Muscles were submerged in a Tyrode solution containing (in mmol/L) ...
-
bioRxiv - Neuroscience 2022Quote: ... diluted to 3.9 ×1012 vg/ml) were injected into the striatum using a Hamilton syringe infusion pump (World Precision Instruments, Sarasota, Florida, USA) at a perfusion speed of 200 nl/min.
-
bioRxiv - Neuroscience 2020Quote: ... conjugated with Alexa Fluor-555 (1 mg/ml) was injected into the vitreous of the right eye of Tbr2TauGFP/+ mice using a 35-gauge NanoFil system (World Precision Instruments, Sarasota, FL). Two days after CTB injection ...
-
bioRxiv - Physiology 2021Quote: The mixed sample was then transferred to a 5 mL syringe and perfused using an Aladdin AL-1000 syringe pump (World precision instruments, United Kingdom) through the ibidi slide ...
-
bioRxiv - Neuroscience 2023Quote: ... AAV8-CAG-Nuc-flox(mCherry)-EGFP (150 nl at 3.12E+12 vg/mL) was then injected at a rate of 30 nl/min using a micro syringe pump (World Precision Instruments, SYS-MICRO4). The needle was then withdrawn after staying in the same position for 5 min ...
-
bioRxiv - Neuroscience 2023Quote: ... or hemoglobin constituted in aCSF at a 150 mg/mL concentration was injected at a rate of 8000 nL/min using a micro-infusion pump (World Precision Instruments, Sarasota, FL) to create the aCSF control and IVH-PHH conditions respectively ...
-
bioRxiv - Neuroscience 2023Quote: ... covered with cells was placed between two plates and an oscillatory pressure-driven fluid flow was propelled through it using 5 mL syringes (Terumo®) mounted on a programmable double syringe pump (AL-4000; World Precision Instruments®, Hertfordshire, UK). The flow rates of 22.45 mL/min and 4.49 mL/min at 0.5 Hz were used to obtain a shear stress magnitude of 0.1 and 0.5 Pa ...