Labshake search
Citations for World Precision Instruments :
1 - 50 of 204 citations for Recombinant Mouse Scavenger Receptor Class B Member 1 His tagged since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2020Quote: ... Glutamate receptor mediated synaptic responses (EPSCs and EPSPs) were evoked with A360 constant-current stimulus isolator (World Precision Instruments, Sarasota, FL, USA) and with stimulation electrodes pulled from borosilicate glass filled with aCSF placed in SLM in the presence 50μM picrotoxin ...
-
bioRxiv - Biophysics 2024Quote: ... oocytes were injected with 2 ng (rat NMDA receptors) or 10 ng (Trichoplax AKDF19383) RNA in 40 nl water using a Nanoliter2010 injector and glass micropipettes (World Precision Instruments). Non-canonical amino acid mutant NMDA receptor channels were expressed by co-injecting oocytes with amber stop codon mutant GluN1(1a ...
-
bioRxiv - Systems Biology 2022Quote: ... 1 mm coronal slices collected using an acrylic brain matrix for mouse (World Precision Instruments) and the primary somatosensory cortex from three slices per brain (Fig ...
-
bioRxiv - Neuroscience 2021Quote: ... 1 mm coronal slices collected using an acrylic brain matrix for mouse (World Precision Instruments) and the regions of interest microdissected under a stereo microscope with a cooled platform ...
-
bioRxiv - Neuroscience 2020Quote: ... Current pulses were delivered via a constant current source (model 305-B, World Precision Instruments). A stimulus generator (A310 Accupulser ...
-
bioRxiv - Neuroscience 2020Quote: ... Row B barrels were injected with viral vectors (40 nl/barrel) using a nanoliter injector (Nanoliter 2010, WPI) ended with a glass capillary backfilled with paraffin oil (catalog ...
-
bioRxiv - Neuroscience 2021Quote: ... The electrode was fixed to the skull using dental cement (C&B Metabond) and surrounding skin was sealed using GLUture (WPI Inc.). Mice were monitored for 7 days post-surgery to ensure proper recovery.
-
bioRxiv - Biophysics 2019Quote: ... 50 pulses, 40 Hz) was generated by a pulse generator (B&K Precision Corporation, Yorba Linda, CA) through an isolator (World Precision Instruments, Sarasota, FL) to induce intrinsic optical signal changes.
-
bioRxiv - Neuroscience 2023Quote: ... Mouse was kept on a heating pad (WPI ATC2000) to maintain stable body temperature at 37 °C and its eyes were kept moist using ophthalmic eye ointment ...
-
bioRxiv - Developmental Biology 2019Quote: Time-pregnant mouse females were anesthetized with a classic small animal anesthesia (isoflurane) system (WPI, USA). In utero electroporation was performed as described in García-Frigola et al ...
-
bioRxiv - Pathology 2021Quote: ... body temperatures were measured using a thermocouple thermometer and mouse rectal probe (World Precision Instruments, RET-3). Blood glucose measurements were obtained with 2uL of tail vein blood analyzed with a Bayer CONTOUR Blood Glucose Monitor and Test Strips ...
-
bioRxiv - Molecular Biology 2024Quote: ... 1 mm (WPI). The collected brain samples were stored in individual tubes at -20 °C until further analysis.
-
bioRxiv - Neuroscience 2020Quote: ... the mouse was either perfused for histology or its skull was protected with Kwik-Cast (World Precision Instruments) for the next experiment ...
-
bioRxiv - Neuroscience 2019Quote: ... D/V=4 and 10uM epoxomicin in 1% DMSO or 1%DMSO alone as a control were infused unilaterally using a micro-pump (UMP3-1, WPI, Berlin ...
-
bioRxiv - Pathology 2022Quote: ... The core body temperature was measured rectally with a Thermometer equipped with a RET-3 mouse rectal temperature probe (WPI, Sarasota, FL).
-
bioRxiv - Neuroscience 2021Quote: Eight- to 10-week-old mice were anesthetized with IP ketamine/Xylazine (100mg/kg; 10mg/kg) and placed in a mouse stereotaxic frame (World Precision Instruments, 502600) over a warm heating pad ...
-
bioRxiv - Neuroscience 2019Quote: ... A bipolar tungsten electrode (1 MΩ, WPI) was positioned in the Schaffer collaterals emanating from the CA3 region of the hippocampus ...
-
bioRxiv - Neuroscience 2024Quote: ... we applied 1-s pressure pulses (0.4-0.6 psi) every 2 s for 1 min by a microinjector (PV850, World Precision Instruments). In some experiments ...
-
bioRxiv - Neuroscience 2020Quote: ... Tungsten macroelectrodes (<1 MΩ World Precision Instruments, USA) were used to record the local field potential and the evoked potential in the PeF (coordinates from Bregma ...
-
bioRxiv - Neuroscience 2021Quote: ... Tungsten macroelectrodes (<1 MΩ World Precision Instruments, USA) were used to record the local field potential and the evoked potential in the PeF (coordinates from Bregma ...
-
bioRxiv - Neuroscience 2020Quote: ... and 2 μl of the mixed viruses (1.0-1.3 × 1013 particles/μl) were injected into each side of the mouse striatum using a Hamilton syringe and a syringe infusion pump (World Precision Instruments, Inc., Sarasota, Florida, USA). Small holes were drilled in the skull ...
-
bioRxiv - Developmental Biology 2019Quote: ... They were then dechorinated and embedded laterally in 1% low gelling agarose in a 1-inch glass bottom cell culture dish (Fluordish, World Precision instruments). Real-time imaging was conducted at 28°C using a Nikon C2+ confocal microscope and a 20x (0.95NA ...
-
bioRxiv - Neuroscience 2022Quote: ... APs were evoked with platinum-iridium electrodes generating 1 ms pulses of 10 V cm-1 field potentials via a current stimulus isolator (A385, World Precision Instruments). For physin-GCaMP and vGpH ...
-
bioRxiv - Biochemistry 2023Quote: ... were evoked with platinum-iridium electrodes generating 1 msec pulses of an electric field of 10 V cm−1 via a current stimulus isolator (A385, World Precision Instruments). Laser power at the back aperture was ∼0.32 mW for 637 nm and ∼0.52 mW for 488 nm ...
-
bioRxiv - Neuroscience 2020Quote: ... 1 mm inner diameter borosilicate glass (WPI, 1B100F-4) was pulled with a multistep horizontal puller (P-1000 ...
-
bioRxiv - Neuroscience 2019Quote: ... blood pressure (pressure monitor BP-1; World Precision Instruments) and end expiratory CO2 (Capnograph type 340 ...
-
bioRxiv - Neuroscience 2021Quote: ... A Micro-1 microsyringe pump controller (World Precision Instruments) was used to inject 1.5 μl of virus at a constant rate over 10 minutes ...
-
bioRxiv - Neuroscience 2024Quote: ... and ultra-micro pomp (UMP3T-1, World Precision Instruments) at a flow rate of 10 nl/s ...
-
bioRxiv - Neuroscience 2019Quote: ... 100-150 nl of virus was injected at 1 nl/s with a microinjection syringe pump (UMP3T-1, World Precision Instruments, Sarasota, FL). Following injection ...
-
bioRxiv - Neuroscience 2020Quote: ... A 3 mm round cover glass (#1, World Precision Instruments) was placed over the exposed ...
-
bioRxiv - Neuroscience 2019Quote: ... and blood pressure (Pressure Monitor BP-1; World Precision Instruments). Arterial blood gases were repeatedly measured (PO2 ...
-
bioRxiv - Neuroscience 2019Quote: ... A 3 mm glass coverslip (#1 thickness, World Precision Instruments) was glued onto the tube to seal the end that was inserted into the craniotomy ...
-
bioRxiv - Neuroscience 2020Quote: ... Recording pipettes were fabricated from 1-mm borosilicate glass (WPI), with tip resistances of 6–8 MΩ ...
-
bioRxiv - Neuroscience 2022Quote: ... A 3 mm glass coverslip (#1 thickness, World Precision Instruments) was glued onto the tube to seal the end that was inserted into the craniotomy ...
-
bioRxiv - Neuroscience 2022Quote: ... using a microinjection syringe pump (UMP3T-1, World Precision Instruments). The pipette tip was left in place for 10min after each infusion before being slowly retracted ...
-
bioRxiv - Neuroscience 2021Quote: ... Extracellular recordings were obtained using tungsten electrodes (TM31C40KT, 4-MΩ impedance at 1 kHz or TM31A50KT, 5-MΩ impedance at 1 kHz; World Precision Instruments Inc., Sarasota FL, USA). All recordings were pre-amplified in the DC mode ...
-
bioRxiv - Neuroscience 2021Quote: ... which was mounted on a MicroSyringe Pump (UMP3-1, World Precision Instruments) and controlled by a SYSMicro4 Controller (World Precision Instruments) ...
-
bioRxiv - Neuroscience 2024Quote: ... Patch-clamp recordings were performed using 1 mm diameter glass micropipettes (WPI) pulled (Sutter P1000 ...
-
bioRxiv - Neuroscience 2019Quote: A glass micropipette (1–3 MΩ impedance; 2-μm tip; World Precision Instruments) was connected to a pneumatic injector (3–20 PSI ...
-
bioRxiv - Neuroscience 2019Quote: Electrodes were prepared daily by the following procedure: 1) borosilicate glass capillaries (WPI) pulled on a Narishige PC-10 puller (∼5 megaohms ...
-
bioRxiv - Neuroscience 2020Quote: ... covered with ∼1% agarose and protected with a silicone elastomer (Kwik-Cast, WPI). After the experiments ...
-
bioRxiv - Neuroscience 2021Quote: ... A 30-gauge Hamilton syringe coupled to a UMP3T-1 pump (WPI, USA) was used to inject 4 µl of Aβo or Aβsc (infusion rate = 0.5 µl/min ...
-
bioRxiv - Neuroscience 2022Quote: ... A 3 mm round cover glass (#1, World Precision Instruments, Sarasota, FL, USA) was placed over the exposed ...
-
bioRxiv - Neuroscience 2022Quote: ... controlled by a microsyringe pump with SMARTouch Controller (UMP3T-1, World Precision Instruments) over ten minutes ...
-
bioRxiv - Neuroscience 2023Quote: ... Isoflurane (1-2%) mixed with oxygen was delivered through a nose cone (WPI). Buprenex® (buprenorphine ...
-
bioRxiv - Neuroscience 2023Quote: ... 1 ms electric pulse generated by a stimulus isolator (World Precision Instruments, A365) was delivered onto the unit’s receptive field by a concentric bipolar electrode (World Precision Instruments ...
-
bioRxiv - Neuroscience 2024Quote: ... the recording electrodes (made of borosilicate glass capillary drawn, 1 MΩ, PG10165, WPI) were placed in the stratum radiatum of the dorsal CA1 area of the hippocampus ...
-
bioRxiv - Physiology 2020Quote: ... 1 μM peptide solution was infused with a syringe pump (World Precision Instruments, LLC.) into the buffer ...
-
bioRxiv - Physiology 2019Quote: Extracellular microelectrodes were made from filamented capillary tubes (1 mm diameter; World Precision Instruments) pulled to a tip resistance of approximately 5-7 mΩ ...
-
bioRxiv - Neuroscience 2021Quote: ... the craniotomy and the Ag/AgCl ground pellet (1 × 2.5 mm, World Precision Instruments) were then submerged in a 2 % agarose (in saline ...