Labshake search
Citations for World Precision Instruments :
1 - 50 of 442 citations for Mouse Anti Canine Distemper Virus Surface Envelope Antibody 5 4 since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2021Quote: ... AAV virus was injected with a glass pipette using an infusion pump (Micro 4, WPI, USA). Viruses were injected bilaterally into target brain areas using the following coordinates ...
-
bioRxiv - Neuroscience 2022Quote: AAV virus was infused via an infusion cannula (33G, PlasticsOne Inc., C315IS-4/SPC) connected to a microinfusion pump (World Precision Instruments LLC, UltraMicroPump3–4), through the implanted infusion cannula ...
-
bioRxiv - Neuroscience 2022Quote: AAV virus was infused via an infusion cannula (33G, PlasticsOne Inc., C315IS-4/SPC) connected to a microinfusion pump (World Precision Instruments LLC, UltraMicroPump3–4), through the implanted cannula ...
-
bioRxiv - Neuroscience 2019Quote: ... DiI crystals were manually placed just under the tissue surface using a pulled capillary glass (World Precision Instruments, 1B120F-4) using a dissecting microscope ...
-
bioRxiv - Neuroscience 2021Quote: ... Virus was injected at a rate of 40 μl/min controlled via a microsyringe pump (UltraMicroPump3–4; World Precision Instruments, Sarasota, FL). Upon recovery ...
-
bioRxiv - Neuroscience 2019Quote: ... recording electrodes (2-5 MΩ; borosilicate glass capillaries (WPI #1B150F-4) pulled on a horizontal puller from Sutter Instruments (model P-97) ...
-
bioRxiv - Neuroscience 2021Quote: For GBA quantification (n=5 for 4 WPI, n=3 for 8 WPI), the surface function of the Imaris software was used to select only GFP-positive cells by appropriately adjusting the number of voxels as well as the intensity of the GFP channel in the threshold tab ...
-
bioRxiv - Neuroscience 2021Quote: For GBA quantification (n=5 for 4 WPI, n=3 for 8 WPI), the surface function of the Imaris software was used to select only GFP-positive cells by appropriately adjusting the number of voxels as well as the intensity of the GFP channel in the threshold tab ...
-
bioRxiv - Neuroscience 2021Quote: ... The surface was covered by silicon elastomer (Kwik-Sil, WPI) to protect the craniotomy until the recording ...
-
bioRxiv - Neuroscience 2020Quote: ... Surface of the corpus callosum was protected with QuickSil (WPI) then the cannula with the window was implanted and fixed to the heaplate of the animal.
-
bioRxiv - Neuroscience 2022Quote: ... Virus was injected using a microsyringe pump (World Precision Instruments); >5 minutes elapsed before the pipette was moved from the ventral injection site to the more dorsal injection site ...
-
bioRxiv - Genetics 2022Quote: ... and filled with a Microfil 28 needle (MF28G67-5 4; World Precision Instruments, Inc.). The chorion of Sciara is very thin and does not need to be removed for injection ...
-
bioRxiv - Neuroscience 2021Quote: ... was used to infuse virus with Micro4 Controller (World Precision Instruments). Virus was infused at 50 nL/min ...
-
bioRxiv - Neuroscience 2021Quote: ... was used to infuse virus with Micro4 Controller (World Precision Instruments), injecting at coordinates relative to bregma/skull (mm) ...
-
bioRxiv - Neuroscience 2020Quote: ... The virus was injected using with an injector (Nanoliter 2010, WPI) in the thalamus or cortex through a small skull incision.
-
bioRxiv - Neuroscience 2020Quote: ... The virus was injected using a syringe pump (World Precision Instruments) at a rate of 0.1 µl/min and left in place for 10 minutes after injection to allow viral particle diffusion before the needle removal ...
-
bioRxiv - Neuroscience 2021Quote: ... Virus was injected using a microsyringe pump controller (World Precision Instruments); >2 minutes elapsed before the pipette was moved from the ventral injection site to the more dorsal injection site ...
-
bioRxiv - Neuroscience 2021Quote: ... was used to infuse virus with Micro4 Controller (World Precision Instruments). Virus was infused at 50-100 nL/min ...
-
bioRxiv - Neuroscience 2020Quote: ... Electrodes with a resistance of 4-5 MΩ were pulled from borosilicate capillaries (WPI, USA) in a horizontal puller (P1000 ...
-
bioRxiv - Neuroscience 2023Quote: ... Borosilicate glass pipettes were used with a resistance of 3-5 MΩ (1B150F-4; WPI). Patch clamp recordings were acquired and filtered at 10 kHz with the internal Bessel filter using a Multiclamp 700B (Molecular Devices ...
-
bioRxiv - Neuroscience 2023Quote: ... Skull surface was covered with Kwik-Sil (World Precision Instruments, Sarasota, FL).
-
bioRxiv - Neuroscience 2024Quote: ... exposed brain surface around the implant was covered by Kwik-Cast (WPI) and was then fixed on skull with dental adhesive resin cement (Super-Bond ...
-
bioRxiv - Physiology 2021Quote: ... Reference electrodes (5-10 megaohms) were pulled using filamented capillaries (1B100F-4, World Precision Instruments, USA) and back-filled with 1 M KCl ...
-
bioRxiv - Neuroscience 2020Quote: ... 4~5 MΩ for whole-cell recording) were pulled from borosilicate capillary glass (World Precision Instruments) with a Stutter P-97 horizontal puller ...
-
bioRxiv - Neuroscience 2022Quote: ... The surface of the lens was covered with kwik-sil (World Precision Instruments) to prevent damage prior to baseplate surgery ...
-
bioRxiv - Neuroscience 2022Quote: ... The cortical surface was covered with Kwik-Sil (World Precision Instruments, Sarasota, FL) and mice were allowed to recover.
-
bioRxiv - Neuroscience 2021Quote: ... The exposed skull surface was then covered with silicone elastomer (Kwik-Cast, WPI) and a thin layer of dental cement ...
-
bioRxiv - Neuroscience 2022Quote: ... Skull surface was covered with silicone (Kwik-Sil; WPI Surgical Instruments, Sarasota, FL), covering the ground wires while ensuring some slack to avoid snapping of the wires ...
-
bioRxiv - Neuroscience 2023Quote: ... the surface of the brain was covered in Kwik-Sil (World Precision Instruments). There was a 10 sec waiting period between injections ...
-
bioRxiv - Neuroscience 2023Quote: ... the surface was covered with biocompatible sealants (Kwik-Sil and Kwik-Cast, WPI). The following day ...
-
bioRxiv - Neuroscience 2019Quote: ... virus was injected bilaterally using a 10 μl nanofil syringe (World Precision Instruments) fitted with a 33-gauge beveled needle ...
-
bioRxiv - Neuroscience 2023Quote: ... 0.3μl of the virus was injected by a 10μl microinjector (World Precision Instruments). The craniotomy hole was plugged by bone wax and the skin was sutured ...
-
bioRxiv - Neuroscience 2022Quote: ... Virus was withdrawn into the 10 uL syringe (World Precision Instruments, Sarasota, USA) and 1uL of the diluted virus was injected into the bulb using 35 gage metal needle (World Precision Instruments) ...
-
bioRxiv - Neuroscience 2023Quote: Virus injections were made using a microinjection pump (World Precision Instruments; MICRO-2T) and pulled glass electrodes (Drummond Scientific Company ...
-
bioRxiv - Neuroscience 2023Quote: ... the exposed brain surface was sealed with biocompatible adhesive (World Precision Instruments, KWIK-CAST). Birds were allowed to recover for at least one week before any data collection ...
-
bioRxiv - Neuroscience 2023Quote: ... the surface of the brain was covered by Kwik-Seal (World Precision Instruments, USA) and the electrode and its plug embedded by dental cement (Tetric EvoFlow ...
-
bioRxiv - Neuroscience 2020Quote: ... The glass pipette consisted of 5 barrels in an H configuration (World Precision Instruments, catalogue no. 5B120F-4) with the tip broken to a diameter of 30–40 μm [37] ...
-
bioRxiv - Neuroscience 2023Quote: ... Mice were anesthetized using 4% isoflurane (Piramal) in 100% O2 for 3 to 5 min (World Precision Instruments, Small Animal Anesthesia System ...
-
bioRxiv - Neuroscience 2019Quote: ... delivering virus at a rate of 35nl per min with a controller (Micro4; WPI). The glass injection pipette was left in place for 10 min postinjection ...
-
bioRxiv - Neuroscience 2022Quote: ... 0.5 μL of the virus was injected using an automated pump (World Precision Instruments) and a 10 μL microsyringe (Hamilton Co. ...
-
bioRxiv - Neuroscience 2024Quote: ... Virus injection was done with a 10 μL Hamilton syringe (nanofil, WPI, Sarasota, FL) and a 33-gauge beveled needle ...
-
bioRxiv - Neuroscience 2023Quote: ... Drug was perfused to the cortical surface through an infusion pump (Micro4, World Precision Instruments) at a rate of 0.5 μL/min (2 μL volume in total) ...
-
bioRxiv - Neuroscience 2021Quote: ... and was then backfilled with virus using a syringe driver (AL-1000, World Precision Instruments). To monitor progress of the injection ...
-
bioRxiv - Bioengineering 2020Quote: ... The micropipette was then frontloaded with virus or cells using a controller (WPI, Sys-Micro4). In general ...
-
bioRxiv - Neuroscience 2023Quote: ... Virus was then injected into the targeted region using a 33 gauge beveled needle (WPI) and a 10 μL Hamilton syringe controlled by an injection pump (WPI) ...
-
bioRxiv - Neuroscience 2023Quote: ... Virus was injected into the target area using a pulled-glass capillary (World Precision Instruments) and a pressure injector (Micro4 controller ...
-
bioRxiv - Neuroscience 2024Quote: ... Virus was injected into the PMv bilaterally using a pulled glass capillary (World Precision Instruments) by nanolitre pressure injection at a flow rate of 50 nL per min (Micro4 controller ...
-
bioRxiv - Bioengineering 2020Quote: ... the exposed surface of the brain was sealed with Kwik-Sil (World Precision Instruments, Sarasota, FL)23 ...
-
bioRxiv - Neuroscience 2021Quote: ... dorsal-ventral (DV): 4.2 mm from brain surface) using a nanoinjector (World Precision Instruments, Nanoliter 2000). For bilateral recording ...
-
bioRxiv - Neuroscience 2023Quote: ... the brain surface around the pipette was sealed with a silicone adhesive (Kwikcast, World Precision Instruments). This prevented the surface from drying out and injected liquid from leaking out of the brain ...