Labshake search
Citations for World Precision Instruments :
51 - 100 of 237 citations for Dengue Virus Serotype 3 Envelope Protein HEK293 since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
Brainstem modulation of nociception by periaqueductal gray neurons expressing the mu-opioid receptorbioRxiv - Neuroscience 2022Quote: ... Virus was infused at a rate of 100 nL/min using a Hamilton syringe with a microsyringe pump (World Precision Instruments). Mice received 250-500 nL of virus ...
-
bioRxiv - Neuroscience 2023Quote: ... A total volume of 0,5 ul of the virus was injected at a controlled rate of 0.1 µl min−1 using a microinjector (WPI, Sarasota, USA) The pipette was slowly lowered to the target site and remained in place for another 5 min post-injection before being slowly withdrawn ...
-
bioRxiv - Cell Biology 2023Quote: ... A total of 0.5 μl of each virus per cochlea was delivered into the scala media using a glass micropipette (WPI, Sarasota, FL) held by a Nanoliter 2000 micromanipulator (WPI) ...
-
bioRxiv - Neuroscience 2024Quote: Virus was injected using a 34–35 G beveled needle in a 10ul NanoFil Sub-Microliter Injection syringe (World Precision Instruments) controlled by an injection pump (Harvard Apparatus) ...
-
bioRxiv - Neuroscience 2023Quote: ... was used to inject 250 nL of virus at a rate of 0.25 µL/min using a microsyringe pump (UMP3 UltraMicroPump, Micro4; World Precision Instruments), for coordinates see Table 1 ...
-
bioRxiv - Neuroscience 2020Quote: ... pipettes (World Precision Instruments, 1B150F-3) were pulled (Sutter ...
-
bioRxiv - Neuroscience 2021Quote: ... M3516)-filled glass pipette (WPI, TW100F-3) and delivered at rate 30 nl/min using a micro-infusion pump (Harvard Apparatus ...
-
bioRxiv - Neuroscience 2021Quote: ... was inserted in the dorsal horn to carefully deliver CAV virus at 2 nl/s with the aid of electronically controlled nanoinjector (Nanoliter 2010, WPI, FL, US). Three injections ...
-
bioRxiv - Neuroscience 2022Quote: ... For the injection of AAV-Syn-sDarken the virus was loaded into a microliter syringe (Hamilton) equipped with a NanoFil needle (NF35BV, World Precision Instruments). The syringe was lowered into the brain at four locations to inject virus into the PrL (AP +2.7 mm ...
-
bioRxiv - Neuroscience 2022Quote: ... A volume of 250 nl virus (100 nl/min) was injected at each location using a four-channel micro controller (SYS-Micro4, World Precision Instruments) and allowed to diffuse for 5 min before syringe was slowly removed ...
-
bioRxiv - Neuroscience 2021Quote: ... Virus was injected at a rate of 40 μl/min controlled via a microsyringe pump (UltraMicroPump3–4; World Precision Instruments, Sarasota, FL). Upon recovery ...
-
bioRxiv - Neuroscience 2021Quote: ... Approximately 1 µl (2 x 1010 GC/hemisphere) virus was dispensed using a NanoFil syringe with a 33G beveled needle (World Precision Instruments). The other hemisphere was injected in the same way ...
-
bioRxiv - Neuroscience 2022Quote: ... 300nL of AAV virus cocktail was injected bilaterally at a rate of 100nL/min controlled by a MicroSyringe Pump Controller (World Precision Instruments). Following injection ...
-
bioRxiv - Neuroscience 2023Quote: ... 20 nl of the Cre-dependent helper virus was injected to the HDB (bilateral, n = 2; unilateral, n = 1) using a Nanoliter 2010 microinjection pump (World Precision Instruments). The injection coordinates were defined by a stereotaxic atlas (Paxinos and Franklin ...
-
bioRxiv - Neuroscience 2023Quote: ... 1.2 µL of the virus solution was injected at a rate of 10 nL/s using a microinjection pump (either Neurostar NanoW or WPI NanoLiter 2010) with mineral oil (Sigma ...
-
bioRxiv - Neuroscience 2024Quote: ... 50-100 nL of AAV virus with fast green was injected at a rate of 50 nL min−1 using a Microinject system (World Precision Instruments). Three weeks after injection ...
-
bioRxiv - Neuroscience 2024Quote: ... A total of 250 nL of virus solution was injected at a rate of 50 nL/min using a micro pump and Micro4 controller (World Precision Instruments).
-
bioRxiv - Developmental Biology 2022Quote: ... glass capillaries (World Precision Instruments TW100-3) were pulled using a P-97 Flaming Brown needle puller (Sutter Instrument ...
-
bioRxiv - Neuroscience 2023Quote: ... Glass capillaries (WPI, cat. No. 1B100-3) coated with a drop of heparin (50U/ml ...
-
bioRxiv - Neuroscience 2023Quote: ... Using an UltraMicroPump 3 (World Precision Instruments), 5.5 μg of Rho-BR-EVs were injected into the lateral ventricle at a 1 μl/min rate ...
-
bioRxiv - Developmental Biology 2023Quote: ... glass capillaries (World Precision Instruments TW100-3) are pulled using a P-97 Flaming Brown needle puller (Sutter Instrument ...
-
bioRxiv - Neuroscience 2021Quote: ... Dorsal laminectomy was performed to expose the lumbar spinal cord prior to virus injection using a pulled borosilicate glass pipette (World Precision Instruments, Inc.) and a micro syringe pump injector (Smart Touch) ...
-
bioRxiv - Neuroscience 2019Quote: ... was inserted into the brain and the virus was injected at a rate of 25 nl/min using Microsyringe Pump (World Precision Instruments, Micro4). After infusion ...
-
bioRxiv - Neuroscience 2019Quote: ... 100-150 nl of virus was injected at 1 nl/s with a microinjection syringe pump (UMP3T-1, World Precision Instruments, Sarasota, FL). Following injection ...
-
bioRxiv - Neuroscience 2020Quote: ... Virus was infused at a rate of 25 nl/min with a micropump and controller (World Precision Instruments, UMP3 pump and Micro4 controller) for a total of 250 nl (DMH ...
-
bioRxiv - Neuroscience 2020Quote: ... Virus was delivered at a rate of 100 nl/min for up to 150-200 nl using an UltraMicroPump (World Precision Instruments, Sarasota, FL). Medial prefrontal cortex (mPFC ...
-
bioRxiv - Neuroscience 2020Quote: ... through a micropipette (World Precision Instruments, TW150-3) and applying gentle mechanical force ...
-
bioRxiv - Physiology 2020Quote: ... and audible baseline monitor (model ABM-3, WPI) as previously described27 ...
-
bioRxiv - Cancer Biology 2023Quote: ... Filamented glass needles (TW100F-3, World Precision Instruments) pulled with a P-97 Flaming/Brown micropipette puller (Sutter Instrument ...
-
bioRxiv - Neuroscience 2019Quote: ... A single injection of 1 µl virus was conducted at a speed of 100 nl/min using a nanoliter injector (Nanoliter2010, World Precision Instruments, Sarasota, FL, USA), controlled by a microsyringe pump controller (Micro4 pump ...
-
bioRxiv - Neuroscience 2022Quote: AAV virus was infused via an infusion cannula (33G, PlasticsOne Inc., C315IS-4/SPC) connected to a microinfusion pump (World Precision Instruments LLC, UltraMicroPump3–4), through the implanted infusion cannula ...
-
bioRxiv - Neuroscience 2022Quote: AAV virus was infused via an infusion cannula (33G, PlasticsOne Inc., C315IS-4/SPC) connected to a microinfusion pump (World Precision Instruments LLC, UltraMicroPump3–4), through the implanted cannula ...
-
bioRxiv - Neuroscience 2020Quote: ... A craniotomy was made over the right visual cortex (3 to 4.5 mm in diameter) and viruses were injected with a micropump (UMP-3, World Precision Instruments) at a rate of 2 nl/s ...
-
bioRxiv - Neuroscience 2021Quote: ... A long tempered small tip (2 — 3 μm in diameter) patch pipette (∼3 MΩ; borosilicate glass, WPI, GBF 150-86-10) was used to pressure inject the dye into the extracellular space at 4 — 6 psi for 14 minutes ...
-
bioRxiv - Neuroscience 2020Quote: ... a craniotomy was made over the right visual cortex (3 to 4.5 mm in diameter) and viruses were injected with a micropump (UMP-3, World Precision Instruments) at a rate of 2 nl/s ...
-
bioRxiv - Neuroscience 2019Quote: ... Electrophysiological recordings were performed at room temperature (25 °C) with glass pipettes with open tip resistance of 3-6 MΩ (TW150F-3, World Precision Instruments, & 100µL calibrated pipettes #534332-921,VWR International) ...
-
bioRxiv - Neuroscience 2021Quote: ... we used four individual samples (exceptions: SST RML 10 WPI: n = 3; PV NBH 10 WPI: n = 3; Astro RML 18 WPI: n = 2). RNA was converted to cDNA using the Transcriptor High Fidelity cDNA Synthesis Kit (Roche Aplied Science) ...
-
bioRxiv - Bioengineering 2023Quote: ... Using a microinjection pump (UMP-3; World Precision Instruments), 0.2⨉106 D425-GL cells were injected in a volume of 3 μL at 30 nL/s ...
-
bioRxiv - Biophysics 2023Quote: ... Thin-wall capillaries (TW150F-3, World Precision Instruments, Germany) were pulled with a DMZ-universal puller (Zeitz ...
-
bioRxiv - Neuroscience 2021Quote: ... we used four individual samples (exceptions: SST RML 10 WPI: n = 3; PV NBH 10 WPI: n = 3; Astro RML 18 WPI: n = 2). RNA was converted to cDNA using the Transcriptor High Fidelity cDNA Synthesis Kit (Roche Aplied Science) ...
-
bioRxiv - Neuroscience 2020Quote: ... A 3 mm round cover glass (#1, World Precision Instruments) was placed over the exposed ...
-
bioRxiv - Neuroscience 2019Quote: ... A 3 mm glass coverslip (#1 thickness, World Precision Instruments) was glued onto the tube to seal the end that was inserted into the craniotomy ...
-
bioRxiv - Neuroscience 2022Quote: ... A 3 mm glass coverslip (#1 thickness, World Precision Instruments) was glued onto the tube to seal the end that was inserted into the craniotomy ...
-
bioRxiv - Bioengineering 2021Quote: ... Pulled glass capillaries (TW120-3, World Precision Instruments, Sarasota, FL) were made using a glass puller and filament (P-97 and FB315B ...
-
bioRxiv - Neuroscience 2021Quote: ... The implanted GRIN lens was secured using 3 M Vetbond (WPI) on the skull ...
-
bioRxiv - Neuroscience 2021Quote: ... Glass pipettes (3-4 MΩ resistance, World Precision Instruments (Sarasota, FL)) were filled with an intracellular solution containing the following ...
-
bioRxiv - Neuroscience 2021Quote: ... A borosilicate glass capillary (1B100F-3; World Precision Instruments, Sarasota, FL) was filled with 10% sucrose water and embedded into a cotton plug ...
-
bioRxiv - Neuroscience 2021Quote: ... Two sharp borosilicate glass (1B100F-3; World Precision Instruments, Sarasota, FL) electrodes were prepared using an electrode puller (P-2000 ...
-
bioRxiv - Neuroscience 2021Quote: ... A borosilicate glass capillary (1B100F-3; World Precision Instruments, Sarasota, FL) was filled with 10% sucrose water and embedded into a cotton plug ...
-
bioRxiv - Neuroscience 2022Quote: ... A 3×5 mm2 craniotomy was drilled (Omnidrill35, World Precision Instruments) over an area covering the monocular and binocular primary visual (V1m and V1b ...