Labshake search
Citations for World Precision Instruments :
201 - 250 of 797 citations for 9 10 Dihydro 4H benzo 4 5 cyclohepta 1 2 b thiophen 4 one since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2024Quote: ... controlled by a pulse generator (Master 9; World Precision Instruments, Sarasota, FL, USA).
-
bioRxiv - Neuroscience 2021Quote: ... The patch pipettes with a tip resistance of 4-6 MΩ were made of borosilicate glass (World Precision Instruments) with a Sutter pipette puller (P-97 ...
-
bioRxiv - Developmental Biology 2022Quote: ... It is connected to working solutions kept at 37 °C via a 4-channel peristaltic pump (WPI, PERIPRO-4LS). Lower GI tract was harvested and transferred to the organ bath with the Krebs buffer was flowing through ...
-
bioRxiv - Physiology 2019Quote: ... Hemolymph Na+ and K+ concentrations were measured using ion-selective borosilicate microelectrodes (TWI150-4, World Precision Instruments, Sarasota, USA). No interference from the FITC-dextran was found when measuring ions ...
-
bioRxiv - Neuroscience 2020Quote: ... The patch pipettes with a tip resistance of 4-6 MΩ were made of borosilicate glass (World Precision Instruments) with a Sutter pipette puller (P-97 ...
-
bioRxiv - Neuroscience 2020Quote: ... and anterior muscle cells were patched using fire-polished 4−6 MΩ resistant borosilicate pipettes (World Precision Instruments, USA). Membrane currents were recorded in the whole-cell configuration by HEKA EPC-9 patch clamp amplifier ...
-
bioRxiv - Neuroscience 2021Quote: ... DV -5.7) at a rate of 50 nl/minute using a microinjector-controlled syringe (micro-4, World Precision Instruments) and needle (Nanofil 33G beveled needle ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch pipettes were pulled from filament-containing borosilicate glass capillaries (TW150F-4; World Precision Instruments Inc., Sarasota, FL, USA) using a Flaming/Brown Micropipette Puller (Model P-97 ...
-
bioRxiv - Physiology 2022Quote: ... The onset of SD was measured electrophysiologically with glass microelectrodes: Filamented glass capillaries (1B100F-4, World Precision Instruments (WPI), Sarasota ...
-
bioRxiv - Physiology 2022Quote: ... The onset of SD was measured electrophysiologically with glass microelectrodes: Filamented glass capillaries (1B100F-4, World Precision Instruments (WPI), Sarasota ...
-
bioRxiv - Neuroscience 2023Quote: ... Focal extracellular recordings from the axons of the antennal nerve were made with glass microelectrodes (1B100F–4, WPI Inc.) filled with 0.15 M sodium chloride and inserted at the scape-pedicel joint ...
-
bioRxiv - Physiology 2023Quote: ... a pressure pipette (OD 3–4 μm) attached to a micropressure system (model 900A; World Precision Instruments, Sarasota, FL) was inserted into an early proximal segment ...
-
bioRxiv - Cell Biology 2024Quote: ... Resistance measurements were performed 4 days later in triplicate using an EVOM Epithelial Volt/ohm meter (World Precision Instruments). The values represent the average of three replicates minus the background resistance ...
-
bioRxiv - Neuroscience 2023Quote: ... Current clamp recordings were performed with pipettes pulled (Sutter P-97) using borosilicate capillary tubes (WPI Cat # 1B150F-4) with open tip resistances of 20 +/- 3 MΩ filled with internal solution containing the following (in mM) ...
-
bioRxiv - Cell Biology 2023Quote: ... +2.5 mm L/M and −3.0 mm D/V using pulled borosilicate glass micropipettes (WPI, Sarasota, FL, #1B100-4). Glass micropipettes were mounted to the stereotaxic frame via specialized connectors and attached ...
-
bioRxiv - Neuroscience 2021Quote: ... we used four individual samples (exceptions: SST RML 10 WPI: n = 3; PV NBH 10 WPI: n = 3; Astro RML 18 WPI: n = 2). RNA was converted to cDNA using the Transcriptor High Fidelity cDNA Synthesis Kit (Roche Aplied Science) ...
-
bioRxiv - Neuroscience 2021Quote: ... DV: −5.9 mm from Bregma) over 5 min using 10 μl Nanofil syringes (World Precision Instruments), with 33 gauge needles ...
-
bioRxiv - Neuroscience 2021Quote: ... of 7 μm in diameter were aspirated into ethanol-cleaned glass capillaries (1.2 mm O.D., 0.68 mm I.D., 4 inches long; World Precision Instruments, FL, USA). The glass capillaries were then pulled using a P-2000 micropipette puller (Sutter Instruments ...
-
bioRxiv - Neuroscience 2019Quote: ... Recording pipettes were pulled on a PP-830 vertical puller (Narishige) from borosilicate glass pipettes (1B150F-4, World Precision Instruments). Patch pipettes were pulled to resistances of 5-7 MΩ for hair cells ...
-
bioRxiv - Neuroscience 2020Quote: ... Patch pipettes were pulled from borosilicate glass capillaries (1.0 mm outside diameter, 0.58 mm inside diameter, 1B100F-4, World Precision Instruments) using a P-1000 puller (Sutter Instruments) ...
-
bioRxiv - Neuroscience 2020Quote: Pipettes for OGB injections were pulled from borosilicate glass capillaries (1B150F-4, outer diameter 1.5 mm, inner diameter 0.84 mm, World Precision Instruments) using a micropipette puller (P-97 ...
-
bioRxiv - Neuroscience 2019Quote: ... DiI crystals were manually placed just under the tissue surface using a pulled capillary glass (World Precision Instruments, 1B120F-4) using a dissecting microscope ...
-
bioRxiv - Cancer Biology 2022Quote: ... Borosilicate glass capillaries with a length of 4 inches and an OD of 1.0 mm (World Precision Instruments, FL, USA) were used for microinjection ...
-
bioRxiv - Molecular Biology 2022Quote: ... Patch recording pipettes (4-6 MΩ) were pulled from thin-walled borosilicate capillary glass (World Precision Instruments [WPI], Sarasota, FL) on a P-2000 laser electrode puller (Sutter Instrument ...
-
bioRxiv - Molecular Biology 2022Quote: ... Patch recording pipettes (4-6 MΩ) were pulled from thin-walled borosilicate capillary glass (World Precision Instruments [WPI], Sarasota, FL) on a P-2000 laser electrode puller (Sutter Instrument ...
-
bioRxiv - Neuroscience 2023Quote: ... of 7[µm in diameter were aspirated into ethanol-cleaned glass capillaries (1.2[mm O.D., 0.68[mm I.D., 4 inches long; World Precision Instruments, FL, USA). The glass capillaries were then pulled using a P-2000 micropipette puller (Sutter Instruments ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch pipettes were pulled to resistances of ∼3 MΩ from thin-walled glass capillaries (World Precision Instruments, Cat# 1B120F-4). Importantly ...
-
bioRxiv - Neuroscience 2023Quote: ... was used to create a micropipette (tip diameter 30-50 µm) from a micro glass tube (1.0-mm diameter; TW100F-4; WPI, USA). The pulled micropipette was then beveled using a micro grinder (EG-402 ...
-
bioRxiv - Neuroscience 2023Quote: Whole-cell patch-clamp recordings were obtained using patch pipettes pulled from borosilicate glass capillaries (1B120F-4, World Precision Instruments). Pipette tip resistances were ∼4-10 MΩ for amacrine cell recordings in the ganglion cell layer ...
-
bioRxiv - Neuroscience 2021Quote: ... we used four individual samples (exceptions: SST RML 10 WPI: n = 3; PV NBH 10 WPI: n = 3; Astro RML 18 WPI: n = 2). RNA was converted to cDNA using the Transcriptor High Fidelity cDNA Synthesis Kit (Roche Aplied Science) ...
-
bioRxiv - Neuroscience 2020Quote: ... Viral construct were administered in 4 injections within GPe using a UMP3 microsyringe pump injector (World Precision Instruments, Sarasota, FL, USA) with 100µl Hamilton syringe ...
-
bioRxiv - Neuroscience 2022Quote: ... Patch pipettes with a resistance of 4–6 MΩ were pulled from borosilicate glass capillaries (1.5 mm outer diameter, 0.86 mm internal diameter, World Precision Instruments, USA) using a micropipette puller (PC-10 ...
-
bioRxiv - Neuroscience 2019Quote: Single-unit recordings in 3 awake Pcp2-Cre-Ai27D mice were performed using borosilicate glass electrodes (1B100F-4, World Precision Instruments) with 1- to 2-μm tips and 3 to 12 MΩ impedance ...
-
bioRxiv - Immunology 2020Quote: 1.5 mm outer diameter and 1.12 mm inner diameter borosilicate glass capillaries were purchased from World Precision Instruments (WPI# TW150-4). We optimized fabrication procedures to obtain micropipettes with 2 μm diameter tips ...
-
bioRxiv - Neuroscience 2022Quote: Single-unit recordings of Purkinje neurons and cerebellar nuclei neurons were performed using borosilicate glass electrodes (1B100F-4, World Precision Instruments) with 1-to 2-μm tips ...
-
bioRxiv - Biophysics 2023Quote: ... using a Sutter P-97 puller and heat-polished to final resistances between 0.5 and 4 MΩ using a MF-200 microforge (World Precision Instruments). 90% series resistance (Rs ...
-
bioRxiv - Neuroscience 2024Quote: ... dorsoventral from the brain surface [DV] 1.9 mm) at a speed of 50 nL/min using a UMP3 pump regulated by Micro-4 (World Precision Instruments). For the optogenetic silencing experiments (Figure 1H–N) ...
-
bioRxiv - Neuroscience 2020Quote: ... We introduced one bipolar stimulating electrode (WPI, ref. TM53CCNON) in the perforant pathway (from bregma ...
-
bioRxiv - Neuroscience 2020Quote: Somatic whole cell patch clamp recordings of visually identified CA1 principal cells were performed after 16-23 DIV with microelectrodes (3-8 MΩ) prepared from borosilicate glass capillaries (1B150F-4 World Precision Instruments) using a Sutter P-1000 puller ...
-
bioRxiv - Cancer Biology 2019Quote: Melanoma cells were injected into the circulation of 2dpf larvae with a microinjection apparatus and needles were pulled from capillaries (TW100-4, World precision instruments). Transplanted larvae were kept overnight at 28ºC in embryo media ...
-
bioRxiv - Neuroscience 2020Quote: ... The administration speed was held constant at 800 nL/min by an injection pump (World Precision Instruments, Inc., UMP 3-4, USA), and the time interval between each injection path was 5 min (43) ...
-
bioRxiv - Neuroscience 2021Quote: ... 200 nl of 1:1 mixture of AAV5 CAG-FLEx-TCb and AAV8 CAG-FLEx-RG was injected into the PVH at a speed of 50 nl/min using a UMP3 pump regulated by Micro-4 (World Precision Instruments). For local circuit mapping (Fig ...
-
bioRxiv - Neuroscience 2019Quote: ... TdTomato-expressing (Vglut3lineage) dissociated DRG neurons and HEK cells were performed with patch pipettes pulled from standard borosilicate glass (1B150F-4, World Precision Instruments) with a P-97 puller (Sutter Instruments) ...
-
bioRxiv - Neuroscience 2021Quote: ... Virus was injected at a rate of 40 μl/min controlled via a microsyringe pump (UltraMicroPump3–4; World Precision Instruments, Sarasota, FL). Upon recovery ...
-
Prelimbic proBDNF facilitates memory destabilization by regulation of neuronal function in juvenilesbioRxiv - Neuroscience 2022Quote: ... which was arrayed into a 4×8 matrix using 25-μm-diameter tungsten wires (California Fine Wires) in a 35-gauge silica tube (World Precision Instruments). A cannula was attached to a silica tube ...
-
bioRxiv - Neuroscience 2022Quote: Pipettes for patch clamping were prepared freshly on the day of electrophysiology experiments from filamented glass capillaries (1B150F-4, World Precision Instruments) using a horizontal pipette puller (P1000 ...
-
bioRxiv - Neuroscience 2023Quote: ... A total of 250 nL AAV was dispensed at each cortical layer through a glass-capillary-attached Hamilton syringe at a rate of 40 nL/min using a UltraMicroPump-4 system (World Precision Instruments). To image UDP in hippocampus ...
-
bioRxiv - Molecular Biology 2024Quote: ... PRV-CAG-EGFP (BrainVTA, Cat. P03001) was injected into unilateral inguinal WAT (4 × 200 nL) using a 36-gauge beveled needle (WPI, Cat. NF36BV). After the injection ...
-
bioRxiv - Neuroscience 2023Quote: ... 250 nL of either AAV8 hSyn-DIO-hM3Dq-mCherry or AAV5 hSyn-DIO-mCherry was bilaterally injected into the PVH at a speed of 50 nL/min using a UMP3 pump regulated by Micro-4 (World Precision Instruments). The coordinates for injection into the supraoptic nucleus were as follows ...
-
bioRxiv - Neuroscience 2023Quote: ... 250 nL of either AAV serotype 9 OTp-mCherry was bilaterally injected into the PVH and the supraoptic nucleus at a speed of 50 nL/min using a UMP3 pump regulated by Micro-4 (World Precision Instruments).