Labshake search
Citations for World Precision Instruments :
351 - 400 of 736 citations for 8 Chloro 1 2 3 4 tetrahydro 1 4 methylphenyl sulfonyl 5H 1 benzazepin 5 one since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2023Quote: ... using a glass micropipette and a micro infusion pump (1 μl at 0.2 μl/min; Micro4, WPI).
-
bioRxiv - Cell Biology 2023Quote: ... thin wall glass capillaries (1 mm outer diameter, 0.78 mm inner diameter; World Precision Instruments, TW100F-6) were pulled using a P-97 micropipette puller (Sutter Instruments ...
-
bioRxiv - Biophysics 2022Quote: ... one end of the silver wires (diameter – 125 μm, WPI, USA) was melted over a fire flame to create a ball end ...
-
bioRxiv - Genomics 2023Quote: ... Embryos at the one-cell stage were injected (WPI Pneumatic PicoPump) with 1 nL of injection mix ...
-
bioRxiv - Bioengineering 2021Quote: ... Electrochemical characterizations were performed in a three-electrode configuration, using a thick (2-mm diameter, ~5 mm2) Pt wire (WPI, 99.99%) as counter electrode (CE ...
-
bioRxiv - Neuroscience 2020Quote: ... The craniotomy was sealed with agarose (1.5–2%, dissolved in artificial cerebrospinal fluid) and a 5 mm glass coverslip (World Precision Instruments) was placed over it ...
-
bioRxiv - Biochemistry 2021Quote: ... Proteins were subject to nano-electrospray ionization (nESI) in positive ion mode (at ∼2 kV) with a pulled nanospray tip (World Precision Instruments 1B100-3) prepared as detailed in (48) ...
-
bioRxiv - Neuroscience 2023Quote: ... and 26-gauge needle (Hamilton) at a flow rate of 100 nl/min driven by a microsyringe pump controller (World Precision Instruments, model Micro 4). The syringe needle was left in place for 10 min and was completely withdrawn 17 min after viral delivery ...
-
bioRxiv - Neuroscience 2023Quote: ... Recording pipettes (10-15 MΩ) were pulled from borosilicate capillary glass (BF150-86-10, Sutter Instruments, Novato, USA or 1B150F-4, World Precision Instruments, Sarasota, USA) in a horizontal pipette puller (P-1000 Micropipette puller ...
-
bioRxiv - Genetics 2023Quote: ... 0.5nl of the mixtures were directly injected into the yolk of freshly layed zygotes using a glass capillary needle [TW120-4) (Kwik-Fil, World Precision Instruments, Inc., Hertfordshire, UK)] with the help of a pedal controlled microinjector (PV820 Pneumatic PicoPump ...
-
bioRxiv - Neuroscience 2020Quote: ... Solution of 1% PhAc was delivered into the LC through a pneumatic pump (PV-820, World Precision Instruments). In this technique ...
-
bioRxiv - Neuroscience 2020Quote: ... Two small burr holes were drilled to allow for a 1 μL NanoFil syringe needle (World Precision Instruments) to be lowered into the desired part of the brain ...
-
bioRxiv - Neuroscience 2022Quote: ... 1 mM at a rate of 100 nl/min using a microinjection pump (UltraMicroPump III, World Precision Instruments) through an injection cannula attached to the photometry fiber (Doric Lenses ...
-
bioRxiv - Neuroscience 2020Quote: Evoked postsynaptic currents were induced by brief (1 ms) unipolar current pulses (0.1–0.9 mA) from an external stimulator (A365, WPI) using a stimulating electrode (CBAEC75 ...
-
bioRxiv - Microbiology 2020Quote: ... they were sectioned into 1-mm-thick slices using a stainless steel tissue matrix (World Precision Instruments, UK). Tissue slices were then mounted in 3D-printed imaging containers as described before [50] ...
-
bioRxiv - Developmental Biology 2019Quote: ... embryos were embedded in 1% low-melting point agarose on Fluoro-Dish glass bottom dishes (World Precision Instruments) and whole mount confocal imaging was performed with a LSM 510 confocal microscope (Zeiss ...
-
bioRxiv - Neuroscience 2021Quote: ... and slowly pressure injected (100 nl min-1) using a 10 ml Hamilton syringe (nanofil; WPI, Sarasota, FL), a 33 gauge beveled needle ...
-
bioRxiv - Pharmacology and Toxicology 2022Quote: ... and amputated at the posterior edge of the notochord with a 1 mm sapphire blade (World Precision Instruments) on 2% agarose-coated dishes under a Nikon SMZ1500 stereomicroscope ...
-
bioRxiv - Neuroscience 2023Quote: ... 0.1–0.5 mA) of axons in the stratum radiatum region using a platinum-iridium microelectrode (0.5 MΩ, WPI) positioned 100–300 μm from the recorded cell ...
-
bioRxiv - Neuroscience 2023Quote: Mice were anaesthetized with Avertin 500 mg kg-1 and placed into a stereotactic frame (World Precision Instruments). Bilateral craniotomies were performed using 0.5 mm diameter drill and the virus was injected using a 10 ml Hamilton microsyringe filled with mineral oil ...
-
bioRxiv - Neuroscience 2024Quote: ... Injections were performed at a rate of 50 nL min−1 using a Microinject system (World Precision Instruments) and the pipette was allowed to sit in the brain for 3 minutes post-injection ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... SM preparations were fixed between a stationary stainless steel hook and an isometric force transducer (AE 801, SensoNor A/S, Norten, Norway) coupled to an AD converter Lab-Trax 4/16 (World Precision Instruments, Inc., Sarasota, FL, USA). The data were continuously recorded using DataTrax2 (World Precision Instruments ...
-
Glyoxal Does Not Preserve Cellular Proteins as Accurately as PFA: A Microscopical Survey of EpitopesbioRxiv - Cell Biology 2019Quote: hUC-MSCs (1×105 cells/cm2) were plated onto glass-bottomed 35-mm Petri dishes (World Precision Instruments, USA) in complete medium (DMEM/HAM’s F12 + 10% FBS ...
-
bioRxiv - Neuroscience 2019Quote: ... a single slice was transferred to a heated chamber (32 °C) and perfused with normal ACSF (2.5 ml min−1) using a peristaltic pump (WPI). Visualization of neurons in the pyramidal layer of hippocampal CA1 was performed with an upright microscope equipped for differential interference contrast (DIC ...
-
bioRxiv - Cell Biology 2020Quote: Microelectrodes were pulled from thin-walled borosilicate glass capillary tubes (1 mm O.D., 0.75 mm I.D., World Precision Instruments) with a Brown-Flaming type micropipette puller (Sutter P-87 ...
-
bioRxiv - Cancer Biology 2021Quote: ... brains containing tumours were collected and dissected into 1 mm coronal sections using a brain matrix (WPI, RBMS-200C). The tumour bulk and invasive tumour front migrating into the striatum (margin ...
-
bioRxiv - Microbiology 2020Quote: Microinjections were performed using borosilicate glass microcapillary injection needles (Science Products, 1210332, 1 mm O.D. x 0.78 mm I.D.) and a PV830 Pneumatic PicoPump (World Precision Instruments). The 48 hpf embryos were manually dechorionated and anesthetized with 200 mg/l buffered tricaine (Sigma ...
-
bioRxiv - Neuroscience 2020Quote: ... and 0.70 nmol of muscimol in 0.3 μl of PBS (Ferraris et al., 2018) was delivered over 60s through a micropump (UltraMicroPump UMP3-1, WPI). The needle was left in place for 3 additional minutes to allow for adequate diffusion of the drug ...
-
bioRxiv - Neuroscience 2021Quote: ... The needle was raised to the injection site where it again remained for one min before injecting started using a flow rate of 70 nL.min−1 and controlled by a microinjection pump (Micro4; WPI). A total of 200 nL virus was injected ...
-
bioRxiv - Neuroscience 2023Quote: ... was loaded into a Hamilton syringe and injected at using a microinjection syringe pump (World Precision Instruments, UMP3T-1) at two AP locations (+1.1 mm and +0.8 mm anterior ...
-
bioRxiv - Neuroscience 2020Quote: ... pipettes (World Precision Instruments, 1B150F-3) were pulled (Sutter ...
-
bioRxiv - Neuroscience 2021Quote: ... M3516)-filled glass pipette (WPI, TW100F-3) and delivered at rate 30 nl/min using a micro-infusion pump (Harvard Apparatus ...
-
bioRxiv - Cancer Biology 2019Quote: CRISPR against vhl and AR was injected into the newly fertilized 1-cells stage embryos using microinjector (Pneumatic PicoPump WPI) at 100uM concentration at 1nl volume.
-
bioRxiv - Neuroscience 2022Quote: ... Square current pulses of 1 ms duration and an intensity of 0.1-10mA (World Precision Instruments Isostim A320, Sarasota, FL) were delivered either as single pulses at 0.1 Hz or as a train of pulses at 20 Hz ...
-
bioRxiv - Neuroscience 2022Quote: ... 300 - 500 nl for thalamus) was pressure-injected in the targeted site with a UMP3-1 ultramicropump (WPI, Sarasota, FL) and glass pipettes (Wiretrol II ...
-
bioRxiv - Physiology 2022Quote: ... In each experiment we detected a principal whisker manually and then a plastic tube (1 mm tip diameter) connected to Pneumatic PicoPump (WPI) was fixed ~1 mm from the whisker for air puff stimulation ...
-
bioRxiv - Neuroscience 2020Quote: ... and the craniotomy was covered by ∼1% agarose dissolved in artificial cerebral spinal fluid (ACSF) and protected by a silicone elastomer (Kwik-Cast, WPI). The mouse was allowed to recover from the anesthesia in home cage for at least 1 hour ...
-
bioRxiv - Neuroscience 2020Quote: ... was lowered into GC (1.9-2.0 mm below the dura) and a microinjection syringe pump (UMP3T-1, World Precision Instruments) was used to inject a total of 200 nL virus at 1 nL/s ...
-
bioRxiv - Developmental Biology 2022Quote: ... gfi1b construct and mRNA transposase were co-injected to the single cell of WT(CD41:GFP) or gata2b-/-(CD41:GFP) zebrafish embryos at 1-cell stage using PV830 Pneumatic PicoPump (WPI). Embryos were anesthetized using 160 mg/L Tricaine (Sigma ...
-
bioRxiv - Neuroscience 2019Quote: ... 2×1000nl for mPFC-infusions) was infused either uni- or bilaterally into the target area using a micro-pump (UMP3-1, WPI, Berlin ...
-
bioRxiv - Pathology 2021Quote: ... FP were excised after topical application of 1% lidocaine using sterile curved spring micro-scissors (McPherson-Vannas, WPI, Sarasota, FL) Type # SR5603 (Roboz Surgical Instrument Co ...
-
bioRxiv - Bioengineering 2021Quote: ... of either 2% or 4% SDS solution was infused through the trachea using a programmable syringe pump (flow rate: 6.3 mL.s-1; AL-4000, World Precision Instruments) to generate a thin film of the detergent solution on the luminal surface of the trachea.49,51 To promote de-epithelization ...
-
bioRxiv - Bioengineering 2021Quote: ... Mice were anesthetized with 3.5 % isoflurane and 1 µl of AAV suspension was injected transsclerally into the vitreous using a 34G canula (WPI, USA). Animals were sacrificed under anesthesia by cervical dislocation 3 weeks after injection and eyes were harvested in 4 % paraformaldehyd for Immunohistochemistry or liquid nitrogen for quantitative reverse transcriptase-PCR.
-
bioRxiv - Microbiology 2022Quote: ... stereotaxic coordinates are shown in Table 1) using a Hamilton syringe connected to a pump (model: UltraMicroPump3; World Precision Instruments). The skin incision on the dorsal head was closed with sterile nylon suture and 2-4% topical chlorhexidine solution was be applied over the closed incision ...
-
bioRxiv - Neuroscience 2022Quote: ... and the femoral artery was cannulated to monitor mean arterial blood pressure (MABP; Pressure Monitor BP-1, World Precision Instruments) and for blood gasses sampling and delivery of fluorescent probes ...
-
Olfactory receptor neurons generate multiple response motifs, increasing coding space dimensionalitybioRxiv - Neuroscience 2022Quote: ... Odorized air (0.5L min-1) was delivered by injecting air with a pneumatic pump (Reliable Pneumatic PicoPump, World Precision Instruments) into the head space of a 100ml glass bottle containing odorant solutions diluted in mineral oil (JT Baker ...
-
bioRxiv - Cancer Biology 2022Quote: ... The Nanoject was mounted at a 25-degree angle relative to the skull surface at each location and actuated by a manual and 1-direction motorized micromanipulator (WPI) at speeds of 600 μm per min ...
-
bioRxiv - Biophysics 2023Quote: ... Virus suspensions were slowly injected (100 nl min−1) using a 34 G beveled needle (Nanofil syringe, World Precision Instruments). After injection ...
-
bioRxiv - Molecular Biology 2023Quote: ... Cardiomyocytes were plated with a density of 50.000 cells/ml on laminin-coated (1:100) fluorodishes (World Precision Instruments, USA) or culture plates ...
-
bioRxiv - Molecular Biology 2024Quote: ... the brain was immediately removed from the skull and sliced into 1 mm thick coronal brain slices with the help of the coronal brain matrix (WPI). The coronal sections were placed on cold saline-soaked filter paper on an ice bath ...