Labshake search
Citations for World Precision Instruments :
401 - 417 of 417 citations for 8 Benzyloxy 5 R 2 bromo 1 hydroxyethyl 1H quinolinone since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Physiology 2023Quote: ... see below) was measured using an Apollo 1000 Free Radical analyser with an ISO-NOPF100 NO microsensor (1 mm) (World Precision Instruments, USA). The sensor was calibrated with S-nitroso-N-Acetyl-D,L-Penicillamine (Toronto Research ...
-
bioRxiv - Neuroscience 2023Quote: ... to a cut segmental nerve and stimulated with a 1 ms suprathreshold stimulus at 0.5 Hz by an A365 stimulus isolator (World Precision Instruments, Sarasota, FL). Only muscle cells with a resting potential more negative than –60mV mV were used for analysis ...
-
bioRxiv - Developmental Biology 2023Quote: ... The following day embryos were washed five times in 1x PBS-Tween and mounted in 1% low-melting point agarose in glass-bottom cell tissue culture dish (Fluorodish, World Precision Instruments, USA).
-
bioRxiv - Neuroscience 2024Quote: ... mice were submitted to stereotaxic surgery and AAV vectors were injected with the help of a microsyringe (0.25 mL Hamilton syringe with a 30-gauge beveled needle) attached to a pump (UMP3-1, World Precision Instruments, FL, USA). Where specified ...
-
bioRxiv - Animal Behavior and Cognition 2022Quote: ... We accomplished this by having Varroa feed on pupae in which 3 μl of 1×107 DAPI microspheres in PBS buffer was injected (31 gauge needle, Micro4 microsyringe pump controller (World Precision Instruments, Sarasota, FL). A second group of pupae which served as a control were injected with PBS ...
-
bioRxiv - Cell Biology 2022Quote: ... A block was then covered with an evenly spread layer of uncured PDMS (mixed at the base to cross-linking agent ratio of 10:1 (w/w)) and pressed against a No.1.5 glass-bottom dish (FD35-100, WPI Inc., Sarasota County, FL, USA). The dish with the negative mold was cured at 60°C for 2 hours to form the micropost topology on the glass surface.
-
bioRxiv - Neuroscience 2019Quote: ... filled with 1 M HRP in 1 M NaCl and a resistance of 7 to 10 MΩ (measured with Ωmega-Tip Z, World Precision Instruments Inc., USA). The electrode was mounted on a piezo drive (Inchworm controller 8200 ...
-
bioRxiv - Neuroscience 2023Quote: ... The right femoral artery was cannulated for continuous recording of mean arterial blood pressure (MAP) and heart rate (fH) using a BP-1 system (WPI Inc., Sarasota, FL, USA) and for monitoring of arterial blood pH ...
-
bioRxiv - Developmental Biology 2023Quote: ... Ventral longitudinal muscle 6 in abdominal segments 3 or 4 was impaled with two intracellular electrodes (1 mm outer diameter borosilicate capillaries; World Precision Instruments, 1B100F-4) of ∼15 MΩ resistance (3M KCl) ...
-
bioRxiv - Neuroscience 2023Quote: ... 15nm Aurovist (0.1 mg/μL) or 1x PBS was then continuously infused into the lateral cerebral ventricle using a syringe pump (World Precision Instruments, Sarasota, FL) via a Hamilton syringe (Hamilton Company ...
-
bioRxiv - Neuroscience 2023Quote: ... ERG records were amplified and band-pass filtered (1-1000 Hz, without notch filtering) using a DAM50 data acquisition board (World Precision Instruments, Aston, UK). A PowerLab system (AD Instruments ...
-
bioRxiv - Neuroscience 2019Quote: ... A single injection of 1 µl virus was conducted at a speed of 100 nl/min using a nanoliter injector (Nanoliter2010, World Precision Instruments, Sarasota, FL, USA), controlled by a microsyringe pump controller (Micro4 pump ...
-
bioRxiv - Neuroscience 2021Quote: ... We monitored ICP via the cisterna magna cannula connected to a transducer attached to a pressure monitor (BP-1, World Precision Instruments Inc., Sarasota, FL). In another set of experiments ...
-
bioRxiv - Bioengineering 2022Quote: ... The PDMS block was then removed from the mold and access ports were cored with a 1-mm biopsy punch (World Precision Instruments, Sarasota, FL, USA).
-
bioRxiv - Neuroscience 2020Quote: The CVs of single fibres were determined by evoking a local action potential with a platinum iridium electrode (1 MΩ; World Precision Instruments Germany GmbH, Berlin, Germany). The electrical impulse was conducted nearly instantaneously through the solution whereas the triggered action potential conducted by the fibre was delayed depending on the fibre type and the distance of the fibre’s receptive field from the electrode ...
-
bioRxiv - Pharmacology and Toxicology 2022Quote: ... 1 for the amount of cRNA used for expression of the indicated P2XR) using a Nanoliter 2000 injector (World Precision Instruments, Sarasota, United States of America) as described previously (Hausmann et al. ...
-
bioRxiv - Biophysics 2021Quote: ... ruIs57[unc-119(+) pie-1::GFP::tubulin]) young adult hermaphrodites using needles pulled from borosilicate glass capillaries (World Precision Instruments,1.0 mm OD, 0.58 mm ID, with filament) with a P-87 micropipette puller (Sutter Instrument) ...