Labshake search
Citations for World Precision Instruments :
151 - 200 of 651 citations for 8 5 6 7 DIHYDRO 2 4 DIPHENYL 5H 1 BENZOPYRAN 8 YL 2 4 PENTADIENYLIDENE 5 6 7 8 TETRAHYDRO 2 4 DIPHENYL 1 BENZOPYRYLIUM TETRAFLUOROBORATE since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2021Quote: ... was assembled prior to injections into the cortex under microscopic control using a microinjection system (UMP3-1, SYS-Micro 4; World Precision Instruments). To increase optogenetic responses after one year ...
-
bioRxiv - Cell Biology 2022Quote: ... IVT reticulocyte lysate was backloaded into a needle pulled from a 1 mm glass capillary tube (TW 100F-4, World Precision Instruments) using a P-87 Micropipette Puller (Sutter Instrument) ...
-
bioRxiv - Microbiology 2019Quote: ... About 20.000 or 150.000 cells were seeded in 8-well chamber slides (see above) or 3.5 mm glass bottom dishes (FluoroDish, WPI, Berlin, Germany), respectively ...
-
bioRxiv - Neuroscience 2024Quote: ... or 1 × 16 trains of 50 APs at 50 Hz (interspaced by 0.5 s) were initiated by a Master-8 (AMPI) and a stimulus generator (A-385, World Precision Instruments) delivering 1 ms pulses of 30 mA ...
-
bioRxiv - Neuroscience 2019Quote: ... 2 CaCl2.2H2O at a rate of 2 ml/min using a perfusion pump (PeriStar Pro; World Precision Instruments, Sarasota, FL). For current clamp recordings of intrinsic membrane properties and current-injected firing ...
-
bioRxiv - Cell Biology 2023Quote: ... thin wall glass capillaries (1 mm outer diameter, 0.78 mm inner diameter; World Precision Instruments, TW100F-6) were pulled using a P-97 micropipette puller (Sutter Instruments ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch pipettes (1.5 – 2 MΩ) (World Precision Instruments) were made using a pipette puller (Narishige ...
-
bioRxiv - Microbiology 2021Quote: ... cRNA was micro-injected into stage 5 or 6 oocytes using a Micro4TM micro-syringe pump controller and A203XVY nanoliter injector (World Precision Instruments, Sarasota, FLA, U.S.A.). Oocytes were maintained in oocyte Ringer’s buffer with added gentamycin (50 μg/ml ...
-
bioRxiv - Neuroscience 2020Quote: ... were delivered to the slice and triggered by a Master 8 pulse generator (AMPI) via a concentric bipolar electrode (WPI, see above). The slice received a single pulse or 10 pulses at 100 Hz ...
-
bioRxiv - Neuroscience 2023Quote: ... was injected bilaterally into the CA3 of 8-12-week-old mice at a rate of 25 nl per min using Microsyringe Pump (World Precision Instruments) as described previously [24] ...
-
bioRxiv - Developmental Biology 2021Quote: ... thin wall glass capillary needles with filament (World Precision Instruments #TW150F-4) were pulled with program 4 “Pro-Nuclear Injection” (Heat ...
-
bioRxiv - Neuroscience 2020Quote: ... Borosilicate capillaries for VTA/SNC (1B150F-4, World Precision Instruments, Friedberg, Germany) and ITC injections (marked 1 to 5 μl ...
-
bioRxiv - Neuroscience 2022Quote: ... Patch pipettes were pulled from borosilicate glass (PG10150-4, World Precision Instruments) and filled with intrapipette solution (35 mM K-gluconate ...
-
bioRxiv - Biophysics 2022Quote: ... a PDMS block with a 4 mm punched (504651 World Precision Instruments) through hole was bonded on a cleaned coverslip ...
-
bioRxiv - Neuroscience 2019Quote: ... and controlled by a microinfusion pump (World Precision Instruments LLC, UltraMicroPump3-4). The syringe was left in place for an additional 10 minutes following injection to facilitate viral spread ...
-
bioRxiv - Cancer Biology 2020Quote: ... thin wall glass capillary needles with filament (World Precision Instruments #TW150F-4) were pulled with program 4 “Pro-Nuclear Injection” (Heat ...
-
bioRxiv - Neuroscience 2022Quote: ... Recording electrodes were prepared from borosilicate filaments (TW150-4, World Precision Instruments) on a P-97 Sutter Instrument micropipette puller and had a resistance of 3 – 6 MΩ ...
-
bioRxiv - Cell Biology 2024Quote: ... Injection was performed with glass capillary needles (World Precision Instruments, 1B100-4), pulled on a micropipette puller (Sutter Instrument ...
-
bioRxiv - Physiology 2024Quote: ... Glass capillaries for microelectrodes (TW150-4, World Precision Instruments, Sarasota, FL, USA) and reference electrodes (1B200F-4 ...
-
bioRxiv - Neuroscience 2024Quote: ... Patch pipettes (4-8MΩ) were made from borosilicate glass (World Precision Instruments) using a Sutter Instruments P-97 model puller.
-
bioRxiv - Neuroscience 2023Quote: ... 1010 gc AAV8 in 1-2 μl was stereotactically injected with 15 nl/sec using a microinjection system (Nanoliter 2010, WPI) at (X ...
-
bioRxiv - Neuroscience 2021Quote: ... a volume of 300 nL of AAV9-cFos-tTa + TRE-EYFP viral cocktail was bilaterally injected at 200 nL/min using a micro-infusion pump for each coordinate (2×300 nL for dDG and 2×300 nL for BLA) (UMP3; World Precision Instruments). After injection was complete ...
-
bioRxiv - Pharmacology and Toxicology 2021Quote: Freshly isolated PAs were cannulated with glass micropipettes (6 in, 1.2 mm OD; 1B120-6, World Precision Instruments) bathed with 37 °C PSS (PSS0Caplus 1.6 mM CaCl2 and without EDTA ...
-
bioRxiv - Developmental Biology 2021Quote: ... The microelectrode and a reference electrode (WPI, DRIREF-2) were then mounted onto the micromanipulator (Narishige MO-202D ...
-
bioRxiv - Neuroscience 2023Quote: ... A 2 MΩ tungsten electrode (World Precision Instruments, TM33A20) driven by a Sutter manipulator was inserted into the depth of TG (around 5 - 6 mm below brain surface) ...
-
bioRxiv - Neuroscience 2023Quote: ... and 35G NanoFil beveled needle (WPI; Catalog# NF35BV-2). The volume of AAVs was 500-1000 nL at the rate 50-100 nL per minute ...
-
bioRxiv - Neuroscience 2023Quote: ... fit with a 36G beveled needle (NF36BV-2, WPI). A high-titre solution of viral vector (AAV9-syn-jGCaMP7f-WPRE ...
-
bioRxiv - Neuroscience 2020Quote: ... Current-controlled stimulation was delivered by a Master-8 pulse stimulator (AMPI, Jerusalem, Israel) connected to a stimulus isolator (A365, WPI Inc, Sarasota, USA).To gauge cortico-striatal excitability ...
-
bioRxiv - Cell Biology 2020Quote: ... and stiff pulling pipette (WPI TW100-6) were used for stretching chromosomes ...
-
bioRxiv - Neuroscience 2023Quote: ... Injection micropipettes were pulled from glass capillary tubes (1B100F-4, World Precision Instruments) and backfilled with virus and then mineral oil and mounted on a Hamilton syringe ...
-
bioRxiv - Developmental Biology 2023Quote: ... Borosilicate glass capillaries (4 inches, OD 1.0 mm, World Precision Instruments, FL, USA) were used for injection ...
-
bioRxiv - Neuroscience 2023Quote: ... Recording electrodes were obtained from borosilicate glass filaments (TW150-4, World Precision Instruments) pulled on a P-97 Micropipette Puller (Sutter Instruments) ...
-
bioRxiv - Bioengineering 2023Quote: ... or saline (1xPBS) were loaded into pulled borosilicate glass micropipettes (WPI #1B100-4) that were ground to a 35° beveled tip with 150–250 μm inner diameter after formulation with sterile-filtered components ...
-
bioRxiv - Neuroscience 2023Quote: ... Recording pipettes were fabricated from borosilicate glass capillaries (TW150F-4, World Precision Instruments) using a P-97 Flaming/Brown micropipette puller (Sutter Instruments) ...
-
bioRxiv - Neuroscience 2023Quote: ... Recording pipettes were fabricated from borosilicate glass capillaries (TW150F-4, World Precision Instruments) using a P-97 Flaming/Brown micropipette puller (Sutter Instruments) ...
-
bioRxiv - Cancer Biology 2024Quote: ... Concentrated cell suspension was loaded into a microcapillary (World Precision Instruments, TW100-4) connected to a FemtoJet 4x (Eppendorf) ...
-
bioRxiv - Neuroscience 2019Quote: ... filled with 1 M HRP in 1 M NaCl and a resistance of 7 to 10 MΩ (measured with Ωmega-Tip Z, World Precision Instruments Inc., USA). The electrode was mounted on a piezo drive (Inchworm controller 8200 ...
-
bioRxiv - Bioengineering 2020Quote: ... 2×104 sGFP sender and 2×104 αGFP receiver cells were seeded into 35-mm FluoroDish Cell Culture Dishes (World Precision Instruments, FD35-100) and immediately imaged under a DeltaVision OMX (GE Healthcare ...
-
bioRxiv - Neuroscience 2019Quote: ... A Nanofil 33-gauge needle (World Precision Instruments, #NF33BV-2) was inserted into the brain and the virus was injected at a rate of 25 nl/min using Microsyringe Pump (World Precision Instruments ...
-
bioRxiv - Neuroscience 2022Quote: ... through a 33G beveled needle (World Precision Instruments, # NF33BV-2), controlled by a micro-syringe pump (World Precision Instruments ...
-
Social Regulation of Egg Size Plasticity in the Honey Bee is Mediated by Cytoskeleton Organizer Rho1bioRxiv - Evolutionary Biology 2022Quote: ... coupled with a 35G needle (NF35BV-2; World Precision Instruments). Injected queens were given time to recover and placed back into their original colonies ...
-
bioRxiv - Neuroscience 2021Quote: ... with a 33-gage beveled Nanofil needle (NF33BV-2, WPI). The syringe was mounted into a motorized microinjector (UMP3T-2 ...
-
bioRxiv - Neuroscience 2022Quote: ... and a microinjection syringe pump (UMP3T-2 World Precision Instruments). Animals received 250 µL of saline for post-surgery hydration.
-
bioRxiv - Neuroscience 2023Quote: ... a Nanofil 33-gauge needle (World Precision Instruments, #NF33BV-2) was slowly inserted into the CA1 region (AP ...
-
bioRxiv - Neuroscience 2023Quote: ... Females: scaled*0.95) using a 33g needle (NF33BV-2, WPI). During the same surgery ...
-
bioRxiv - Genetics 2020Quote: ... phenol red was injected into the yolk of 1- to 2-cell-stage embryos with a Pneumatic PicoPump pv280 (World Precision Instruments). After injection ...
-
bioRxiv - Neuroscience 2021Quote: ... Approximately 1 µl (2 x 1010 GC/hemisphere) virus was dispensed using a NanoFil syringe with a 33G beveled needle (World Precision Instruments). The other hemisphere was injected in the same way ...
-
bioRxiv - Neuroscience 2023Quote: ... 20 nl of the Cre-dependent helper virus was injected to the HDB (bilateral, n = 2; unilateral, n = 1) using a Nanoliter 2010 microinjection pump (World Precision Instruments). The injection coordinates were defined by a stereotaxic atlas (Paxinos and Franklin ...
-
bioRxiv - Cell Biology 2024Quote: ... and injected with 3 μl of AAV9-hSyn-iCre (titer 1 x 1013 to 2 x 1014) into the right lateral ventricle using a nanoliter injector (World Precision Instruments; Micro4 MicroSyringe Pump Controller connected with Nanoliter 2000 ...
-
bioRxiv - Cell Biology 2020Quote: An easily bent force pipette (WPI TW100F-6), and stiff pulling pipette (WPI TW100-6 ...