Labshake search
Citations for World Precision Instruments :
301 - 350 of 398 citations for 7 methylsulfanyl 4 oxo 1H quinoline 3 carboxylic acid since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2023Quote: ... Focal extracellular recordings from the axons of the antennal nerve were made with glass microelectrodes (1B100F–4, WPI Inc.) filled with 0.15 M sodium chloride and inserted at the scape-pedicel joint ...
-
bioRxiv - Physiology 2023Quote: ... The glass microelectrodes were fashioned from 1 mm borosilicate glass capillaries (1B100F-4, World Precision Instruments, Sarasota, FL, USA) pulled to a tip resistance of 5-7 MΩ in a Flaming-Brown P-1000 micropipette puller ...
-
bioRxiv - Neuroscience 2023Quote: ... Current clamp recordings were performed with pipettes pulled (Sutter P-97) using borosilicate capillary tubes (WPI Cat # 1B150F-4) with open tip resistances of 20 +/- 3 MΩ filled with internal solution containing the following (in mM) ...
-
bioRxiv - Cell Biology 2023Quote: ... +2.5 mm L/M and −3.0 mm D/V using pulled borosilicate glass micropipettes (WPI, Sarasota, FL, #1B100-4). Glass micropipettes were mounted to the stereotaxic frame via specialized connectors and attached ...
-
bioRxiv - Cell Biology 2024Quote: ... Resistance measurements were performed 4 days later in triplicate using an EVOM Epithelial Volt/ohm meter (World Precision Instruments). The values represent the average of three replicates minus the background resistance ...
-
bioRxiv - Neuroscience 2021Quote: ... was injected into PR at 0.5 µl/min using G33 needle (Hamilton) connected to a 10 µl micro-syringe controlled by a micro-pump (WPI, UltraMicroPump 3). AM cells were recorded both before and 30 min after injection.
-
bioRxiv - Neuroscience 2022Quote: Mice were anesthetized with 3% isoflurane (Aerrane, Henry Schein) for 2 min and then transferred to the stereotaxic apparatus (Model #502063, World Precision Instruments). Anesthesia was then lowered to 1-2% and monitored the same way as described above for IHKA injection ...
-
A novel neural stem cell-derived immunocompetent mouse model of glioblastoma for preclinical studiesbioRxiv - Cancer Biology 2020Quote: ... to the bregma and 3 mm deep at a flow of 0.2 μL/min using a 10-μL precision microsyringe (World Precision Instruments, Inc) with a 34G needle.
-
bioRxiv - Cell Biology 2021Quote: ... were resuspended in 2–3 mg/ml rat-tail collagen I in RM+ medium and seeded on 23-mm FluoroDish cell culture dishes (World Precision Instruments). The collagen with embedded cells was allowed to set at 37°C until collagen contraction was observed (∼30 min) ...
-
bioRxiv - Neuroscience 2020Quote: ... and temperature measurements with a digital thermometer (Fisher Traceable Type-K thermometer) with rodent rectal temperature probe (World Precision Instruments, RET-3). For experiments performed in a cold environment ...
-
bioRxiv - Cell Biology 2022Quote: Pre-warmed assay media (200 μl) was added to the apical surface of the cultures and TEER was measured using an EVOM-3 meter (World Precision Instruments).
-
bioRxiv - Pathology 2022Quote: ... The core body temperature was measured rectally with a Thermometer equipped with a RET-3 mouse rectal temperature probe (WPI, Sarasota, FL).
-
bioRxiv - Neuroscience 2020Quote: Electrical stimulation was applied through ACSF filled glass pipette (tip diameter 3–5 µm) connected to a linear stimulus isolator (A395, World Precision Instruments) was used to deliver monopolar electrical stimulation (10–90 µA ...
-
bioRxiv - Neuroscience 2020Quote: ... The reference and recording glass electrodes (thin-wall glass capillaries; OD, 1.0 mm; length, 76 mm; World Precision Instruments, cat. # TW100F-3) were pulled using a micropipette puller (Sutter Instrument ...
-
bioRxiv - Bioengineering 2020Quote: ... was injected to separate microfluidic channels in the fiber through tubing connected to a standard precision injection apparatus (100 nl/s, NanoFil Syringe and UMP-3 Syringe pump, World Precision Instruments) while the fiber probe was embedded in 0.6% agarose gel (see details of tubing connection in Multifunctional Neuro Probes Assembly).
-
bioRxiv - Neuroscience 2019Quote: ... Papaverine was locally ejected for ~1 s by 3 times using an air pressure of <15 psi in the pipette (PV830 Pneumatic PicoPump, World Precision Instruments). A red cloud (Alexa 594 ...
-
bioRxiv - Neuroscience 2021Quote: ... 1μL of virus was injected in the dorsal hippocampus and 1μl of virus in the ventral hippocampus (either AAV-miR-499 or AAV-Control) over 3 min via a microinjection pump (World Precision Instruments). The infusion cannula was left in place for an additional 3 min thereafter to allow diffusion ...
-
bioRxiv - Neuroscience 2020Quote: ... Field stimulations (10 Hz*60 s and 30 Hz*3 s) were performed with an A385 current isolator and a SYS-A310 accupulser signal generator (World Precision Instruments). Glycolysis was inhibited with 2-DG [5 mM ...
-
bioRxiv - Neuroscience 2020Quote: ... Extracellular field potentials from de CA1 pyramidal neurons were recorded using a borosilicate glass micropipette (1–3 MΩ; RRID:SCR_008593; World Precision Instruments, Sarasota, US) filled with aCSF positioned on the slice surface in the stratum radiatum of CA1 and connected to the headstage of an extracellular recording amplifier (NeuroLog System ...
-
bioRxiv - Neuroscience 2023Quote: ... Three circular glass coverslip (2 of 3 mm and one 4mm coverslips) was affixed with a clear silicone elastomer (Kwik-sil, World Precision Instruments). A custom 3D-printed stainless steel headpost was attached on the skull and the rest of exposed skull area and the edge of the cranial window were covered using a dental acrylic (C&B Metabond) ...
-
bioRxiv - Neuroscience 2023Quote: ... A connection cable (Plastics One, model 335–340/3) was used to connect the electrodes to a stimulus isolator (WPI, model A365) and the stimulator (AMPI ...
-
bioRxiv - Neuroscience 2023Quote: ... at a rate of 100 nL/minute through a 31-gauge gastight Hamilton syringe attached to a Micro4 Ultra Microsyringe Pump 3 (World Precision Instruments) with a 10 minute waiting period prior to the removal of the needle ...
-
bioRxiv - Neuroscience 2023Quote: ... Animals were injected into their foot with 3-5 µL of 10-5 M ELH using a 10 µL Nanofil syringe (World Precision Instruments) equipped with a 35-gauge needle ...
-
bioRxiv - Molecular Biology 2023Quote: ... The purified dsRNA was diluted to 2,000 ng/μL and 3 μg of dsRNA were injected with a Nanoliter (WPI, Sarasota, FL, USA) to the body cavity via the metapleuron under the wing ...
-
bioRxiv - Bioengineering 2023Quote: ... DV –4.5 mm) using a microinjection apparatus (10 µL Hamilton syringe #80308, UMP-3 syringe pump, and Micro4 controller; all from World Precision Instruments).
-
bioRxiv - Neuroscience 2021Quote: ... of 7 μm in diameter were aspirated into ethanol-cleaned glass capillaries (1.2 mm O.D., 0.68 mm I.D., 4 inches long; World Precision Instruments, FL, USA). The glass capillaries were then pulled using a P-2000 micropipette puller (Sutter Instruments ...
-
bioRxiv - Neuroscience 2019Quote: ... Recording pipettes were pulled on a PP-830 vertical puller (Narishige) from borosilicate glass pipettes (1B150F-4, World Precision Instruments). Patch pipettes were pulled to resistances of 5-7 MΩ for hair cells ...
-
bioRxiv - Neuroscience 2020Quote: ... Patch electrodes (2-4 MΩ) were pulled from borosilicate glass capillaries (1.5 mm OD, 1.12 mm ID; World Precision Instruments) on a Sutter P-97 puller (Sutter Instruments Company ...
-
bioRxiv - Neuroscience 2020Quote: ... Patch pipettes were pulled from borosilicate glass capillaries (1.0 mm outside diameter, 0.58 mm inside diameter, 1B100F-4, World Precision Instruments) using a P-1000 puller (Sutter Instruments) ...
-
bioRxiv - Neuroscience 2020Quote: Pipettes for OGB injections were pulled from borosilicate glass capillaries (1B150F-4, outer diameter 1.5 mm, inner diameter 0.84 mm, World Precision Instruments) using a micropipette puller (P-97 ...
-
bioRxiv - Neuroscience 2020Quote: ... Patch-clamp recording pipettes were fabricated from 1 mm inner diameter borosilicate glass capillaries (World Precision Instruments, item# 1B100F-4). Pipettes were pulled with a multistep horizontal puller (P-1000 ...
-
bioRxiv - Neuroscience 2019Quote: ... DiI crystals were manually placed just under the tissue surface using a pulled capillary glass (World Precision Instruments, 1B120F-4) using a dissecting microscope ...
-
bioRxiv - Cancer Biology 2022Quote: ... Borosilicate glass capillaries with a length of 4 inches and an OD of 1.0 mm (World Precision Instruments, FL, USA) were used for microinjection ...
-
bioRxiv - Molecular Biology 2022Quote: ... Patch recording pipettes (4-6 MΩ) were pulled from thin-walled borosilicate capillary glass (World Precision Instruments [WPI], Sarasota, FL) on a P-2000 laser electrode puller (Sutter Instrument ...
-
bioRxiv - Molecular Biology 2022Quote: ... Patch recording pipettes (4-6 MΩ) were pulled from thin-walled borosilicate capillary glass (World Precision Instruments [WPI], Sarasota, FL) on a P-2000 laser electrode puller (Sutter Instrument ...
-
bioRxiv - Neuroscience 2023Quote: ... of 7[µm in diameter were aspirated into ethanol-cleaned glass capillaries (1.2[mm O.D., 0.68[mm I.D., 4 inches long; World Precision Instruments, FL, USA). The glass capillaries were then pulled using a P-2000 micropipette puller (Sutter Instruments ...
-
bioRxiv - Neuroscience 2023Quote: ... was used to create a micropipette (tip diameter 30-50 µm) from a micro glass tube (1.0-mm diameter; TW100F-4; WPI, USA). The pulled micropipette was then beveled using a micro grinder (EG-402 ...
-
bioRxiv - Neuroscience 2023Quote: Whole-cell patch-clamp recordings were obtained using patch pipettes pulled from borosilicate glass capillaries (1B120F-4, World Precision Instruments). Pipette tip resistances were ∼4-10 MΩ for amacrine cell recordings in the ganglion cell layer ...
-
bioRxiv - Bioengineering 2022Quote: ... The needle was allowed to sit in place for approximately 5 min and 3-5 μL of viral vector was injected using a microsyringe pump (World Precision Instruments, UMP3) and pump controller (World Precision Instruments ...
-
bioRxiv - Pharmacology and Toxicology 2019Quote: Micropipettes with a tip resistance of 3–6 MΩ were prepared from 1.2/0.69-mm OD/ID borosilicate glass capillaries (World Precision Instruments, GC-120F-10) using a pipette puller (Sutter Instruments ...
-
bioRxiv - Neuroscience 2019Quote: ... filled with normal ACSF) using a DAM-80 amplifier (low filter, 1 Hz; high pass filter, 3 KHz; World Precision Instruments, Sarasota, FL). Mossy fiber-mediated fEPSP were evoked by weak electrical stimulations performed via a bipolar NiCh electrode (NI-0.7F ...
-
bioRxiv - Neuroscience 2023Quote: ... Viral Injections were unilaterally or bilaterally delivered using a syringe (65458-01, Hamilton, USA) controlled by an ultra-micropump (UMP-3, World Precision Instruments, USA) at a rate of 0.1 µl/min (total volume of 0.6 µl for slice imaging and 0.4 µl for fiber photometry) ...
-
bioRxiv - Cancer Biology 2023Quote: ... and the cells were injected at the position 2 mm to the right lateral bregma and 3 mm deep with a flow of 0.2 μL/min utilizing a 10 μL precision micro syringe (World Precision Instruments, Florida, USA) with a 34-gauge needle ...
-
bioRxiv - Neuroscience 2023Quote: ... gap-free LFP recordings (15 minute duration) were obtained from the optic tectum using a single-glass microelectrode (WPI glass #TW150 F-3) with approximately 1 μM tip diameter backfilled with 2 mM NaCl internal solution as described previously 29,37–40 ...
-
bioRxiv - Neuroscience 2020Quote: ... Viral construct were administered in 4 injections within GPe using a UMP3 microsyringe pump injector (World Precision Instruments, Sarasota, FL, USA) with 100µl Hamilton syringe ...
-
bioRxiv - Neuroscience 2022Quote: ... Patch pipettes with a resistance of 4–6 MΩ were pulled from borosilicate glass capillaries (1.5 mm outer diameter, 0.86 mm internal diameter, World Precision Instruments, USA) using a micropipette puller (PC-10 ...
-
bioRxiv - Neuroscience 2019Quote: ... Recording patch pipettes were pulled with a PC-10 vertical electrode puller (Narishige) from 1.5 mm outer and 1 mm inner diameter patch clamp glass capillaries without filament (WPI, #PG52151-4). Pipette resistance with Ca2+ current recording solutions was ∼3.5 MΩ for pupal and adult MN5 ...
-
bioRxiv - Immunology 2020Quote: 1.5 mm outer diameter and 1.12 mm inner diameter borosilicate glass capillaries were purchased from World Precision Instruments (WPI# TW150-4). We optimized fabrication procedures to obtain micropipettes with 2 μm diameter tips ...
-
bioRxiv - Neuroscience 2022Quote: Single-unit recordings of Purkinje neurons and cerebellar nuclei neurons were performed using borosilicate glass electrodes (1B100F-4, World Precision Instruments) with 1-to 2-μm tips ...
-
bioRxiv - Biophysics 2023Quote: ... using a Sutter P-97 puller and heat-polished to final resistances between 0.5 and 4 MΩ using a MF-200 microforge (World Precision Instruments). 90% series resistance (Rs ...