Labshake search
Citations for World Precision Instruments :
301 - 350 of 615 citations for 7 HYDROXY 5 METHYL 1 3 4 TRIAZAINDOLIZINE since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2020Quote: Patch clamp pipettes were pulled from borosilicate capillaries (1B120F-4, World Precision Instruments, Inc., Sarasota, FL, USA) with a horizontal puller (P-87 ...
-
bioRxiv - Neuroscience 2020Quote: ... patch pipettes with a resistance of 4∼6 MΩ were made from borosilicate glass (World Precision Instruments) with a PC-10 Narishige puller and filled with a pipette solution containing the following (in mM) ...
-
bioRxiv - Biophysics 2019Quote: ... An ACSF-filled glass pipette (opening diameter 10-30 µm, 1B120F-4, World Precision Instruments, Sarasota, FL) was used for Schaffer collateral nerve stimulations ...
-
bioRxiv - Pharmacology and Toxicology 2019Quote: ... Microinjection needles were created from glass capillary tubes (058 mm inner diameter; World Precision Instruments, 1B100F-4) using a pipette puller (Sutter instrument model p-30 ...
-
bioRxiv - Neuroscience 2023Quote: ... Recording pipettes with resistances of 2-4 MΩ were pulled from borosilicate glass capillaries (World Precision Instruments). The pipette tip was filled with gramicidin-free KCl solution (140 mM KCl and 10 mM HEPES ...
-
bioRxiv - Neuroscience 2022Quote: ... and controlled by a micromanipulator connected to a pneumatic picopump (4 psi, World Precision Instruments, SYS-PV820). Constant circulation of aCSF was maintained in the dish during the recording ...
-
Serotonergic Modulation of Spinal Circuitry Restores Motor Function after Chronic Spinal Cord InjurybioRxiv - Neuroscience 2023Quote: ... The junction was secured using 4-0 silk suture and liquid silicone (World Precision Instruments, Kwik-Sil). Note that an additional small incision was made above the cannula-implant site to expose the proximal (or silicone ...
-
bioRxiv - Neuroscience 2023Quote: Patch pipettes with 4.5-6.5 MΩ tip resistance were prepared from borosilicate glass capillaries (TW150F-4, WPI) using micropipette pullers (HEKA PIP 6 and MDI PMP102) ...
-
bioRxiv - Cell Biology 2023Quote: ... Microinjection was performed using borosilicate glass capillaries (4 inches, OD 1.0 mm, World Precision Instruments, FL, USA). 200-250 HeLa cells transfected with si-NC or si-METTL3 at a concentration of 25 nM were injected directly into the middle of the yolk sac of the larva ...
-
bioRxiv - Neuroscience 2023Quote: ... followed by AAV injections using a micro-syringe connected to a micropump (UltraMicroPump 4, WPI surgical instruments), which was lowered into the brain until it reached the DV coordinates (see below for details) ...
-
bioRxiv - Biochemistry 2023Quote: ... The samples were electrosprayed from gold-coated borosilicate glass capillaries Kwik-Fil 1B120F-4 (World Precision Instruments) prepared in-house essentially as described before (49 ...
-
bioRxiv - Developmental Biology 2024Quote: ... with needles pulled using a Model P-1000 Flaming Brown Micropipette Puller (World Precision Instruments, TW100F-4). Needles were cut to yield an injection volume of ∼1nL.
-
Treatment with furosemide indirectly increases inhibitory transmission in the developing hippocampusbioRxiv - Neuroscience 2023Quote: ... Recording pipetes with resistances of 2-4 MΩ were pulled from borosilicate glass capillaries (World Precision Instruments). The pipete tip was filled with gramicidin-free KCl solution (140 mM KCl and 10 mM HEPES ...
-
bioRxiv - Neuroscience 2021Quote: ... The recording glass electrode (thin-wall glass capillaries; OD, 1.0 mm; length, 76 mm; World Precision Instruments, cat. # TW100F-3) was pulled using a micropipette puller (Sutter Instrument ...
-
bioRxiv - Neuroscience 2020Quote: ... Viral suspensions were loaded in beveled glass capillaries (tip diameter: 15-30 µm) and injected with a micropump (UMP-3, WPI) at a rate of 20-30 nl/minute into the parenchyma ...
-
bioRxiv - Neuroscience 2023Quote: ... 30–120 nl of virus were injected at a rate of 3 nl/s at two depths (0.1 mm and 0.2 mm ventral/below pia) using a microsyringe pump (UMP-3, World Precision Instruments).
-
bioRxiv - Neuroscience 2021Quote: ... DV: −5.9 mm from Bregma) over 5 min using 10 μl Nanofil syringes (World Precision Instruments), with 33 gauge needles ...
-
bioRxiv - Neuroscience 2021Quote: ... over a 5-min period at each depth using a UMP3 microsyringe pump (World Precision Instruments). The X-Y coordinates for the injection site was usually 0.5 mm lateral to the midline and 2.0 mm rostral to bregma ...
-
bioRxiv - Immunology 2019Quote: ... then transection of the tail was performed with a microscalpel (5 mm depth; World Precision Instruments). Neutrophil or macrophage chemotaxis were evaluated by assessing the number of cells at wound sites (the region posterior to the circulatory loop ...
-
bioRxiv - Neuroscience 2022Quote: ... The micropipettes filled with the internal solution using MicroFil Flexible Needle (MF28G67-5, World Precision Instruments) were secured on a patch-clamp headstage (CV-7B ...
-
bioRxiv - Neuroscience 2019Quote: ... and muscle cells were patched using fire-polished 4-6 MΩ resistant borosilicate pipettes (World Precision Instruments, USA). Membrane currents were recorded in the whole-cell configuration by a Digidata 1440A and a MultiClamp 700A amplifier ...
-
bioRxiv - Neuroscience 2022Quote: ... Patch electrodes (final resistance 2–4 MΩ) were pulled from borosilicate glass (World Precision Instruments, Sarasota, FL, USA). The intracellular solution contained (in mM) ...
-
bioRxiv - Pharmacology and Toxicology 2021Quote: Microinjection needles were prepared from glass capillary tubes (0.58 mm inner diameter; World Precision Instruments, FL; 1B100F-4) using a pipette puller (Sutter instrument model p-30 ...
-
bioRxiv - Microbiology 2020Quote: Fly injections were carried out with microinjection needles produced from borosilicate glass capillaries (World Precision Instruments TW100-4) and a needle puller (Model PC-10 ...
-
bioRxiv - Neuroscience 2022Quote: ... A micro-holding device62 was used to keep in the same coordinate the borosilicate capillary (1B150F-4, WPI) containing the LFP electrode and the optic fibre ...
-
bioRxiv - Neuroscience 2022Quote: ... Recording pipettes (resistance of 4-6 MΩ) were pulled from thick-walled borosilicate glass capillaries (World Precision Instruments) and filled with high chloride internal solution (in mM ...
-
bioRxiv - Neuroscience 2022Quote: ... Recording pipettes (resistance of 2-4 MΩ) were pulled from thick-walled borosilicate glass capillaries (World Precision Instruments). The pipette tip was filled with gramicidin-free KCl solution (140 mM KCl and 10 mM HEPES ...
-
bioRxiv - Neuroscience 2023Quote: ... Anterior body wall muscle cells were patched using 4-6 MΩ resistant borosilicate pipettes (World Precision Instruments, USA), which were pulled by micropipette puller P-1000 (Sutter) ...
-
bioRxiv - Neuroscience 2024Quote: ... Neurons were harvested using a thin wall glass capillary tube (4 inch, OD 1.0 MM, World Precision Instruments) into EBSS in a non-stick Eppendorf tube and kept on ice until dissociation.
-
bioRxiv - Neuroscience 2023Quote: ... and DVB soma were patched using 15-20 MΩ-resistant borosilicate pipettes (1B100F-4, World Precision Instruments, USA). Pipettes were pulled by micropipette puller P-1000 (Sutter ...
-
bioRxiv - Genetics 2020Quote: ... Glass needles for zebrafish eggs injections were prepared from glass capillary tubes with filament (ø1 mm × 90 mm) (WPI #1B100F-3) using a NARISHIGE dual-stage micropipette puller PC-10 machine ...
-
bioRxiv - Biophysics 2020Quote: ... were collected by centrifugation for 3 min at 180 RCF and seeded onto glass bottom dishes (fluorodish; #FD35100, WPI, FL, USA) in CO2-independent medium (#18045-054 ...
-
bioRxiv - Neuroscience 2020Quote: ... Germany) and Pulse 8.11 software as described previously.3 Patch pipettes were pulled from borosilicate glass tubing (World Precision Instruments, Germany). The signals were filtered using an eight-pole Bessel filter built into the EPC-9 amplifier and digitized at a frequency ≥ filter cut-off frequency (VR-10B ...
-
bioRxiv - Neuroscience 2022Quote: ... The tip of the pipette was cut to an opening diameter of ∼3 μm and bent to ∼40° using a microforge (WPI, DMF1000). Tethers were pulled with a 4 µm diameter polystyrene bead (Spherotech #DIGP-40-2 ...
-
bioRxiv - Neuroscience 2022Quote: ... We sealed the craniotomy with silicone gel (Dow DOWSIL 3-4680, sometimes called “artificial dura”) and a silicone sealant (WPI KwikCast). We also implanted a stainless steel pin elsewhere on the dorsal surface of the skull ...
-
bioRxiv - Developmental Biology 2024Quote: Erythrocytes were isolated from 3-dpf zebrafish embryos (wild-type and miR-144Δ/Δ) by dissecting their tail using sapphire blade (WPI) and collecting cells in the bleeding buffer (1X PBS containing 2% PBS and 5 mM EDTA) ...
-
bioRxiv - Neuroscience 2023Quote: ... mice were injected in layer 5 of the visual cortex using a microinjection pump (WPI Ltd., USA), 5□µl Hamilton syringe (Esslab Ltd. ...
-
bioRxiv - Neuroscience 2021Quote: ... The patch pipettes with a tip resistance of 4-6 MΩ were made of borosilicate glass (World Precision Instruments) with a Sutter pipette puller (P-97 ...
-
bioRxiv - Developmental Biology 2022Quote: ... It is connected to working solutions kept at 37 °C via a 4-channel peristaltic pump (WPI, PERIPRO-4LS). Lower GI tract was harvested and transferred to the organ bath with the Krebs buffer was flowing through ...
-
bioRxiv - Physiology 2019Quote: ... Hemolymph Na+ and K+ concentrations were measured using ion-selective borosilicate microelectrodes (TWI150-4, World Precision Instruments, Sarasota, USA). No interference from the FITC-dextran was found when measuring ions ...
-
bioRxiv - Neuroscience 2020Quote: ... The patch pipettes with a tip resistance of 4-6 MΩ were made of borosilicate glass (World Precision Instruments) with a Sutter pipette puller (P-97 ...
-
bioRxiv - Neuroscience 2020Quote: ... and anterior muscle cells were patched using fire-polished 4−6 MΩ resistant borosilicate pipettes (World Precision Instruments, USA). Membrane currents were recorded in the whole-cell configuration by HEKA EPC-9 patch clamp amplifier ...
-
bioRxiv - Neuroscience 2021Quote: ... DV -5.7) at a rate of 50 nl/minute using a microinjector-controlled syringe (micro-4, World Precision Instruments) and needle (Nanofil 33G beveled needle ...
-
bioRxiv - Neuroscience 2022Quote: ... D/V = −4) using 10 μl NanoFil syringes equipped with 33 gauge beveled NanoFil needles (World Precision Instruments, Inc.) at a volume of 0.7 μl and a rate of 0.1 μl per minute ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch pipettes were pulled from filament-containing borosilicate glass capillaries (TW150F-4; World Precision Instruments Inc., Sarasota, FL, USA) using a Flaming/Brown Micropipette Puller (Model P-97 ...
-
bioRxiv - Physiology 2022Quote: ... The onset of SD was measured electrophysiologically with glass microelectrodes: Filamented glass capillaries (1B100F-4, World Precision Instruments (WPI), Sarasota ...
-
bioRxiv - Physiology 2022Quote: ... The onset of SD was measured electrophysiologically with glass microelectrodes: Filamented glass capillaries (1B100F-4, World Precision Instruments (WPI), Sarasota ...
-
bioRxiv - Neuroscience 2023Quote: ... Focal extracellular recordings from the axons of the antennal nerve were made with glass microelectrodes (1B100F–4, WPI Inc.) filled with 0.15 M sodium chloride and inserted at the scape-pedicel joint ...
-
bioRxiv - Neuroscience 2023Quote: ... Current clamp recordings were performed with pipettes pulled (Sutter P-97) using borosilicate capillary tubes (WPI Cat # 1B150F-4) with open tip resistances of 20 +/- 3 MΩ filled with internal solution containing the following (in mM) ...
-
bioRxiv - Cell Biology 2023Quote: ... +2.5 mm L/M and −3.0 mm D/V using pulled borosilicate glass micropipettes (WPI, Sarasota, FL, #1B100-4). Glass micropipettes were mounted to the stereotaxic frame via specialized connectors and attached ...