bioRxiv - Cell Biology 2020Quote: Patch pipettes with a resistance of 4∼6 MΩ were made from borosilicate glass (World Precision Instruments) with a Sutter Instrument P-97 micropipette puller and filled with 1M NaCl solution ...
-
bioRxiv - Neuroscience 2020Quote: Patch clamp pipettes were pulled from borosilicate capillaries (1B120F-4, World Precision Instruments, Inc., Sarasota, FL, USA) with a horizontal puller (P-87 ...
-
bioRxiv - Neuroscience 2020Quote: ... patch pipettes with a resistance of 4∼6 MΩ were made from borosilicate glass (World Precision Instruments) with a PC-10 Narishige puller and filled with a pipette solution containing the following (in mM) ...
-
bioRxiv - Biophysics 2019Quote: ... An ACSF-filled glass pipette (opening diameter 10-30 µm, 1B120F-4, World Precision Instruments, Sarasota, FL) was used for Schaffer collateral nerve stimulations ...
-
bioRxiv - Pharmacology and Toxicology 2019Quote: ... Microinjection needles were created from glass capillary tubes (058 mm inner diameter; World Precision Instruments, 1B100F-4) using a pipette puller (Sutter instrument model p-30 ...
-
bioRxiv - Neuroscience 2022Quote: ... and controlled by a micromanipulator connected to a pneumatic picopump (4 psi, World Precision Instruments, SYS-PV820). Constant circulation of aCSF was maintained in the dish during the recording ...
-
Serotonergic Modulation of Spinal Circuitry Restores Motor Function after Chronic Spinal Cord InjurybioRxiv - Neuroscience 2023Quote: ... The junction was secured using 4-0 silk suture and liquid silicone (World Precision Instruments, Kwik-Sil). Note that an additional small incision was made above the cannula-implant site to expose the proximal (or silicone ...
-
bioRxiv - Neuroscience 2023Quote: Patch pipettes with 4.5-6.5 MΩ tip resistance were prepared from borosilicate glass capillaries (TW150F-4, WPI) using micropipette pullers (HEKA PIP 6 and MDI PMP102) ...
-
bioRxiv - Cell Biology 2023Quote: ... Microinjection was performed using borosilicate glass capillaries (4 inches, OD 1.0 mm, World Precision Instruments, FL, USA). 200-250 HeLa cells transfected with si-NC or si-METTL3 at a concentration of 25 nM were injected directly into the middle of the yolk sac of the larva ...
-
bioRxiv - Neuroscience 2023Quote: ... followed by AAV injections using a micro-syringe connected to a micropump (UltraMicroPump 4, WPI surgical instruments), which was lowered into the brain until it reached the DV coordinates (see below for details) ...
-
bioRxiv - Biochemistry 2023Quote: ... The samples were electrosprayed from gold-coated borosilicate glass capillaries Kwik-Fil 1B120F-4 (World Precision Instruments) prepared in-house essentially as described before (49 ...
-
bioRxiv - Developmental Biology 2024Quote: ... with needles pulled using a Model P-1000 Flaming Brown Micropipette Puller (World Precision Instruments, TW100F-4). Needles were cut to yield an injection volume of ∼1nL.
-
bioRxiv - Neuroscience 2021Quote: ... The recording glass electrode (thin-wall glass capillaries; OD, 1.0 mm; length, 76 mm; World Precision Instruments, cat. # TW100F-3) was pulled using a micropipette puller (Sutter Instrument ...
-
bioRxiv - Neuroscience 2020Quote: ... Viral suspensions were loaded in beveled glass capillaries (tip diameter: 15-30 µm) and injected with a micropump (UMP-3, WPI) at a rate of 20-30 nl/minute into the parenchyma ...
-
bioRxiv - Neuroscience 2023Quote: ... 30–120 nl of virus were injected at a rate of 3 nl/s at two depths (0.1 mm and 0.2 mm ventral/below pia) using a microsyringe pump (UMP-3, World Precision Instruments).
-
bioRxiv - Biophysics 2022Quote: ... WT and mutant rP2X2R mRNAs (concentration 50 - 3000 ng μl−1) were injected into the oocyte cytoplasm with a Nanoliter 2010 injector (World Precision Instruments). The volume of mRNA injected varied depending on the construct (10-50 nl) ...
-
bioRxiv - Neuroscience 2020Quote: ... In some experiments drugs (1 mM Glutamate or 100 μM ATP) were puffed for 250 ms just before the bleaching using Pneumatic PicoPump (World Precision Instruments). Imaging ...
-
bioRxiv - Neuroscience 2022Quote: In vivo intracellular recordings of cortical cells were performed in the primary visual cortex (area 1. 17) using sharp Glass electrodes pulled from 1.5-mm-thick borosilicate capillaries (World Precision Instruments Inc.). Electrodes were filled with a 2M potassium methyl sulfate (pH ranging from 7.2 to 7.4) ...
-
bioRxiv - Neuroscience 2020Quote: ... intracranial pressure (ICP) was monitored via the ventricle cannulation connected to a transducer and a pressure monitor (BP-1, World Precision Instruments). ICP was acquired at 1 kHz ...
-
bioRxiv - Physiology 2020Quote: ... The electrodes were insulated by a 3μm kapton sheath (electrode OD 0.356mm) exposing a tip of length 5mm and tip diameter of 1-2μm (World Precision instruments, ref TM33B20KT). They were placed either in the endocardial surface ...
-
bioRxiv - Pharmacology and Toxicology 2022Quote: ... Compounds were superfused to the neuron using a syringe pump (New Era Pump Systems Inc, USA) loaded with 1 mL syringe connected to a 50 cm MicroFil 28G (World Precision Instruments) at 2 μL/min allowing rapid solution exchanges.
-
bioRxiv - Molecular Biology 2022Quote: ... Action potentials were caused by passing a 1 ms current pulse through platinum-iridium electrodes from an isolated current stimulator (World Precision Instruments). Neurons were perfused in saline-based Tyrode’s buffer consisting of 119 mM NaCl ...
-
bioRxiv - Developmental Biology 2020Quote: ... Fertilized eggs were collected after timed matings of adult zebrafish and injected at the 1-cell stage using a Picopump (World Precision Instruments). Embryos were injected with concentrations ranging from 0.15 – 0.5 mM in a volume of 1 nl.
-
bioRxiv - Neuroscience 2019Quote: ... the cranial window contained two ~1 mm diameter holes pre-drilled and filled with a silicone elastomer (Kwik-Sil, World Precision Instruments). A custom 3D-printed headpost was placed around the cranial window and affixed to the skull using C&B Metabond dental cement (Parkell) ...
-
bioRxiv - Neuroscience 2019Quote: ... Two catheters were inserted: the first into the left femoral artery to monitor arterial blood pressure (Pressure Monitor BP-1, World Precision Instruments) and inject compounds ...
-
bioRxiv - Neuroscience 2023Quote: Nanopipettes were fabricated from quartz capillaries with filament (o.d. 1 mm, i.d. 0.5 mm, 10 cm length, World Precision Instruments QF100-50-10). The capillaries were transformed into nanopipettes using a laser puller (P2000 ...
-
bioRxiv - Neuroscience 2022Quote: ... then mounted lateral-side up on a thin layer of 1% low-melt agarose in a tissue culture dish with a cover-glass bottom (FluoroDish; World Precision Instruments) and covered in EMT media ...
-
bioRxiv - Cell Biology 2023Quote: ... from day 1 to day 6 of subculture of BMEC onto Transwells® using an EVOM2 Voltohmmeter/STX2 electrodes (World Precision Instruments). The STX2 electrode was positioned within the well and the resistance (Ω ...
-
bioRxiv - Neuroscience 2023Quote: ... The whiskers contralateral to the recording hemisphere were bundled using Vaseline and a custom stimulator (1 mm aperture attached to a pneumatic picopump; World Precision Instruments) was positioned ∼5 mm from the whisker bundle ...
-
bioRxiv - Neuroscience 2023Quote: ... at a volume of 250 nL per injection at a rate of 100 nL min-1 using a motorized injector (World Precision Instruments) and glass syringe (Hamilton) ...
-
bioRxiv - Neuroscience 2024Quote: ... 50-100 nL of AAV virus with fast green was injected at a rate of 50 nL min−1 using a Microinject system (World Precision Instruments). Three weeks after injection ...
-
bioRxiv - Neuroscience 2021Quote: ... DV: −5.9 mm from Bregma) over 5 min using 10 μl Nanofil syringes (World Precision Instruments), with 33 gauge needles ...
-
bioRxiv - Neuroscience 2021Quote: ... over a 5-min period at each depth using a UMP3 microsyringe pump (World Precision Instruments). The X-Y coordinates for the injection site was usually 0.5 mm lateral to the midline and 2.0 mm rostral to bregma ...
-
bioRxiv - Immunology 2019Quote: ... then transection of the tail was performed with a microscalpel (5 mm depth; World Precision Instruments). Neutrophil or macrophage chemotaxis were evaluated by assessing the number of cells at wound sites (the region posterior to the circulatory loop ...
-
bioRxiv - Neuroscience 2022Quote: ... The micropipettes filled with the internal solution using MicroFil Flexible Needle (MF28G67-5, World Precision Instruments) were secured on a patch-clamp headstage (CV-7B ...
-
bioRxiv - Neuroscience 2019Quote: ... and muscle cells were patched using fire-polished 4-6 MΩ resistant borosilicate pipettes (World Precision Instruments, USA). Membrane currents were recorded in the whole-cell configuration by a Digidata 1440A and a MultiClamp 700A amplifier ...
-
bioRxiv - Pharmacology and Toxicology 2021Quote: Microinjection needles were prepared from glass capillary tubes (0.58 mm inner diameter; World Precision Instruments, FL; 1B100F-4) using a pipette puller (Sutter instrument model p-30 ...
-
bioRxiv - Microbiology 2020Quote: Fly injections were carried out with microinjection needles produced from borosilicate glass capillaries (World Precision Instruments TW100-4) and a needle puller (Model PC-10 ...
-
bioRxiv - Neuroscience 2022Quote: ... A micro-holding device62 was used to keep in the same coordinate the borosilicate capillary (1B150F-4, WPI) containing the LFP electrode and the optic fibre ...
-
bioRxiv - Neuroscience 2022Quote: ... Recording pipettes (resistance of 4-6 MΩ) were pulled from thick-walled borosilicate glass capillaries (World Precision Instruments) and filled with high chloride internal solution (in mM ...
-
bioRxiv - Neuroscience 2023Quote: ... Anterior body wall muscle cells were patched using 4-6 MΩ resistant borosilicate pipettes (World Precision Instruments, USA), which were pulled by micropipette puller P-1000 (Sutter) ...
-
bioRxiv - Neuroscience 2024Quote: ... Neurons were harvested using a thin wall glass capillary tube (4 inch, OD 1.0 MM, World Precision Instruments) into EBSS in a non-stick Eppendorf tube and kept on ice until dissociation.
-
bioRxiv - Neuroscience 2023Quote: ... and DVB soma were patched using 15-20 MΩ-resistant borosilicate pipettes (1B100F-4, World Precision Instruments, USA). Pipettes were pulled by micropipette puller P-1000 (Sutter ...
-
bioRxiv - Physiology 2022Quote: ... pulled from glass tubes (1.12 mm inner / 2 mm outer diameter, World Precision Instruments) and bent at 30 ° to allow near-parallel alignment of the fibres with the bottom of the experimental chamber ...
-
bioRxiv - Neuroscience 2023Quote: ... Bilateral infusions were achieved using a 35-gauge needle (World Precision Instruments NF35BV-2) and a 10 μL Hamilton Syringe (World Precision Instrument NANOFIL) ...
-
bioRxiv - Genetics 2020Quote: ... Glass needles for zebrafish eggs injections were prepared from glass capillary tubes with filament (ø1 mm × 90 mm) (WPI #1B100F-3) using a NARISHIGE dual-stage micropipette puller PC-10 machine ...
-
bioRxiv - Biophysics 2020Quote: ... were collected by centrifugation for 3 min at 180 RCF and seeded onto glass bottom dishes (fluorodish; #FD35100, WPI, FL, USA) in CO2-independent medium (#18045-054 ...
-
bioRxiv - Neuroscience 2020Quote: ... Germany) and Pulse 8.11 software as described previously.3 Patch pipettes were pulled from borosilicate glass tubing (World Precision Instruments, Germany). The signals were filtered using an eight-pole Bessel filter built into the EPC-9 amplifier and digitized at a frequency ≥ filter cut-off frequency (VR-10B ...
-
bioRxiv - Neuroscience 2022Quote: ... The tip of the pipette was cut to an opening diameter of ∼3 μm and bent to ∼40° using a microforge (WPI, DMF1000). Tethers were pulled with a 4 µm diameter polystyrene bead (Spherotech #DIGP-40-2 ...
-
bioRxiv - Neuroscience 2022Quote: ... We sealed the craniotomy with silicone gel (Dow DOWSIL 3-4680, sometimes called “artificial dura”) and a silicone sealant (WPI KwikCast). We also implanted a stainless steel pin elsewhere on the dorsal surface of the skull ...