bioRxiv - Neuroscience 2020Quote: ... Glass injection pipettes (World Precision Instruments, 1B100-4) were pulled using a Sutter P-2000 laser puller and beveled using a Narishige EG-45 grinder ...
-
bioRxiv - Physiology 2020Quote: ... A thinly pulled glass electrode (IB200F-4, WPI) back-billed with 500 mmol L-1 KCl was used as a reference ...
-
bioRxiv - Microbiology 2020Quote: ... and LabTrax 4-Channel Data Acquisition system (WPI). Finally ...
-
bioRxiv - Biophysics 2019Quote: Borosilicate capillary glasses (1B150F−4, World Precision Instruments) were pulled in a horizontal pipette puller (Sutter Instruments) ...
-
bioRxiv - Neuroscience 2023Quote: ... from borosilicate glass (1B200-4, WPI, Sarasota, FL). Pipettes for somatic recording had an impedance of 5-6 MΩ ...
-
bioRxiv - Genomics 2022Quote: ... Standard Glass Capillaries (1B100-4, World Precision Instruments) using a P-2000 needle puller (Sutter instruments) ...
-
bioRxiv - Neuroscience 2020Quote: Test compounds were dissolved in aCSF and locally puff-applied with a patch pipette (4–6 MΩ) at low pressure (∼1 psi) controlled by a Pneumatic Picopump (PV821, World Precision Instruments, USA) for 20 to 90s ...
-
bioRxiv - Neuroscience 2023Quote: ... Glass pipettes with a resistance of 2-4 MΩ were pulled from borosilicate glass capillaries (World Precision Instruments, Cat# TW150-4) using a PC-10 pipette puller (Narishige) ...
-
bioRxiv - Physiology 2020Quote: ... glass capillaries (TW-150-4, World Precision Instruments (WPI), Sarasota ...
-
bioRxiv - Neuroscience 2021Quote: ... Glass capillaries (TW100F-4, World Precision Instruments, Sarasota, FL) were pulled to desired shape using a Sutter Inst ...
-
bioRxiv - Neuroscience 2022Quote: ... using a microinjector pump (UltraMicroPump3-4, World Precision Instruments). The needle was lowered over 1 min and remained in place for 1 min before infusion ...
-
bioRxiv - Neuroscience 2022Quote: ... Recordings: Patch pipettes (4-6 MΩ; World Precision Instruments) were pulled on a P-1000 puller (Sutter Instruments ...
-
bioRxiv - Neuroscience 2024Quote: ... Recording electrodes (WPI; 4–6 MΩ open tip resistance) were filled with an internal solution consisting of (in mM) ...
-
bioRxiv - Neuroscience 2024Quote: ... Injections were performed with microinjector-controlled (micro-4, WPI) syringe (nanofil syringe and Nanofil 33G BVLD Needle ...
-
bioRxiv - Neuroscience 2021Quote: ... Recording pipettes were pulled from glass capillaries (1B150F-4, WPI) to have a ∼20 μm opening ...
-
bioRxiv - Cell Biology 2021Quote: ... A glass micropipette (#1B100-4, World Precision Instruments, Sarasota, USA) was forged to a diameter smaller than the average protoplast radius (∼2.5 µm) ...
-
bioRxiv - Physiology 2020Quote: ... Briefly, glass capillaries (TW-150-4, World Precision Instruments (WPI), Sarasota ...
-
bioRxiv - Cancer Biology 2019Quote: ... with needles pulled from capillaries (TW100-4, World precision instruments, with a tip clipped off and polished of inner diameter at the tip 40-45μm ...
-
bioRxiv - Neuroscience 2021Quote: ... Pulled glass capillaries were used for microinjection (WPI, TW100F-4). Rather than use the ‘inject’ function on the Femtojet ...
-
bioRxiv - Neuroscience 2019Quote: ... Electrodes were pulled from borosilicate glass capillaries (WPI, 1B100F-4) with a Flaming/Brown micropipette puller (Sutter Instruments Co. ...
-
bioRxiv - Pharmacology and Toxicology 2021Quote: ... Fire-polished borosilicate (1B150F-4, World Precision Instruments, FL, USA) patch pipettes were used with resistance of 1-3 MΩ ...
-
bioRxiv - Physiology 2021Quote: ... Non-filamented glass capillaries (1B100-4, World Precision Instruments, USA) were immersed into 99.9 % methanol for five minutes and dried out at room temperature ...
-
bioRxiv - Neuroscience 2020Quote: ... DV -0.4 cm) using a microinjector-controlled (micro-4, WPI) seringe (nanofil seringe and Nanofil 33G BVLD Needle ...
-
bioRxiv - Neuroscience 2021Quote: ... Viruses were injected using a glass micropipette (WPI, 1B120F-4) filled with mineral oil attached to Nanoliter Injector with SMARTouch Controller (WPI ...
-
bioRxiv - Neuroscience 2023Quote: ... Micropipettes pulled from borosilicate glass (1B150F-4, World Precision Instruments) were filled with internal solution containing (in mM) ...
-
bioRxiv - Neuroscience 2023Quote: ... and micro-syringe pump controller (Micro 4; WPI, Sarasota, FL). After each injection ...
-
bioRxiv - Biophysics 2023Quote: ... Borosilicate patch pipettes (1BF120F-4, World Precision Instruments, Sarasota, FL) were pulled on P-2000 (Sutter Instruments ...
-
bioRxiv - Neuroscience 2023Quote: ... Recording electrodes were pulled from glass capillaries (WPI, TW100F-4) to have a 15-30 μm opening and filled with artificial fish water (AFW ...
-
bioRxiv - Animal Behavior and Cognition 2023Quote: ... from a borosilicate glass capillary (1B150F-4, World Precision Instruments) and backfilled with 1 mM copper sulfate (MilliporeSigma) ...
-
bioRxiv - Genetics 2023Quote: ... and borosilicate glass microcapillaries (World Precision Instruments, cat.no.1b100-4), prepared using a micropipette puller device (Sutter
-
bioRxiv - Neuroscience 2024Quote: Borosilicate capillary glass (World Precision Instruments, Cat. No. 1B150F-4) was pulled into a fine tip and then beveled to an angled point ...
-
bioRxiv - Neuroscience 2022Quote: AAV virus was infused via an infusion cannula (33G, PlasticsOne Inc., C315IS-4/SPC) connected to a microinfusion pump (World Precision Instruments LLC, UltraMicroPump3–4), through the implanted infusion cannula ...
-
bioRxiv - Neuroscience 2019Quote: ... was injected through the virus/drug infusion cannula at 100nL/min through an internal infusion cannula (33G, PlasticsOne Inc., C315IS-4/SPC) connected to a microinfusion pump (World Precision Instruments LLC, UltraMicroPump3-4), one week after the window implantation surgery ...
-
bioRxiv - Neuroscience 2022Quote: AAV virus was infused via an infusion cannula (33G, PlasticsOne Inc., C315IS-4/SPC) connected to a microinfusion pump (World Precision Instruments LLC, UltraMicroPump3–4), through the implanted cannula ...
-
bioRxiv - Neuroscience 2022Quote: Whole cell patch clamp was performed on interneurons from the lumbar segments using 2–4 MΩ glass electrodes pulled from glass capillary tubes (Item #TW150F-4, World Precision Instruments, Sarasota, FL, USA) with a Flaming-Brown P-97 (Sutter Instrument Company ...
-
bioRxiv - Neuroscience 2020Quote: ... and a micro-syringe pump controller (Micro 4; WPI, Sarasota, FL). After each injection ...
-
bioRxiv - Neuroscience 2021Quote: ... Glass pipettes (3-4 MΩ resistance, World Precision Instruments (Sarasota, FL)) were filled with an intracellular solution containing the following ...
-
bioRxiv - Neuroscience 2021Quote: ... A 4 mm round #1.5 cover glass (World Precision Instruments, Inc.) was placed over the exposed brain with artificial cerebrospinal fluid filling the void ...
-
bioRxiv - Biophysics 2019Quote: ... Larger biopsy punches (4 mm diameter, World Precision Instruments, Hitchin, UK) were used to cut the outlet reservoir ...
-
bioRxiv - Neuroscience 2021Quote: ... The patch electrodes (3-4 MΩ, World Precision Instruments; 1B150F-3) were filled with intracellular solution containing ...
-
bioRxiv - Neuroscience 2019Quote: ... recording electrodes (2-5 MΩ; borosilicate glass capillaries (WPI #1B150F-4) pulled on a horizontal puller from Sutter Instruments (model P-97) ...
-
bioRxiv - Developmental Biology 2022Quote: ... M-152 micromanipulators (Narishige) and 1B100f-4 capillaries (World Precision Instruments) shaped with P-1000 micropipette puller (Sutter Instrument Company).
-
bioRxiv - Neuroscience 2022Quote: ... Borosilicate glass capillaries (WPI 1B100-4, 1.0 mm o.d. × 0.58 i.d.) were employed to pull very fine pipette with a long needle tip (needle tip size 1-2 μm and needle tip angle ~10°) ...
-
bioRxiv - Pharmacology and Toxicology 2019Quote: ... Injection needles were pulled from borosilicate capillary tubes (TW100F-4, WPI) using a vertical pipette puller (Model P-30 ...
-
bioRxiv - Pharmacology and Toxicology 2021Quote: ... Injection needles were pulled from borosilicate capillary tubes (TW100F-4, WPI) using a vertical pipette puller (Model P-30 ...
-
bioRxiv - Neuroscience 2021Quote: ... and a micro-syringe pump controller (Micro 4; WPI, Sarasota, FL). After each injection ...
-
bioRxiv - Physiology 2024Quote: ... and reference electrodes (1B200F-4, World Precision Instruments, Sarasota, FL, USA) were prepared using a Sutter P-97 Flaming Brown pipette puller (Sutter Instruments ...
-
bioRxiv - Neuroscience 2024Quote: ... and a micro-syringe pump controller (Micro 4; WPI, Sarasota, FL) using slow injection speed (100 nl/min) ...
-
bioRxiv - Developmental Biology 2021Quote: ... thin wall glass capillary needles with filament (World Precision Instruments #TW150F-4) were pulled with program 4 “Pro-Nuclear Injection” (Heat ...
-
bioRxiv - Neuroscience 2020Quote: ... Borosilicate capillaries for VTA/SNC (1B150F-4, World Precision Instruments, Friedberg, Germany) and ITC injections (marked 1 to 5 μl ...