Labshake search
Citations for World Precision Instruments :
251 - 300 of 768 citations for 6H Dipyrido 3 2 b 2' 3' e 1 4 diazepin 6 one 11 ethyl 5 11 dihydro 8 2 hydroxyethyl 5 methyl since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2021Quote: ... Extracellular recordings from the tail were made with borosillicate pipettes (TW150-3, World Precision Instruments) pulled by a vertical puller (PC-10 ...
-
bioRxiv - Biophysics 2020Quote: Pipettes were pulled from borosilicate glass capillaries (TW150F-3; World Precision Instruments, Sarasota, FL, USA) and polished with a microforge (MF-900 ...
-
bioRxiv - Neuroscience 2021Quote: ... Spinal neurons were bulk-loaded for about 3 min using picospritzer (PV820, WPI, Sarasota, USA) by applying 900 ms pulses of 15-25 psi to the pipette to pressure-eject the dye at 3 or more sites approximately 200 μm apart from each other ...
-
bioRxiv - Neuroscience 2019Quote: ... and using thin wall glass pipettes (1.5-3 MΩ, World Precision Instruments, Sarasota, FL, USA) filled with internal solution containing the following in mM ...
-
bioRxiv - Biophysics 2020Quote: ... Patch pipettes were pulled from borosilicate glass tubes (TW150F-3; World Precision Instruments, Berlin, Germany) to give a resistance of about 3 MΩ ...
-
bioRxiv - Bioengineering 2021Quote: ... access ports were opened using a 3-mm biopsy punch (ref. 504649, World Precision Instruments).
-
bioRxiv - Neuroscience 2023Quote: ... gas-tight Hamilton syringe controlled by a Micro4 Ultra Microsyringe Pump 3 (World Precision Instruments) into the nucleus accumbens core (AP ...
-
bioRxiv - Neuroscience 2023Quote: ... gas-tight Hamilton syringe controlled by a Micro4 Ultra Microsyringe Pump 3 (World Precision Instruments). The needle was left in place for 10 minutes following the infusion to allow for diffusion of the virus from the injection site ...
-
bioRxiv - Neuroscience 2024Quote: ... The patch pipettes (2.5 – 3.5 MΩ) were fabricated from borosilicate glass tubes (WPI, 1B150F-3) using a horizontal puller ...
-
bioRxiv - Biophysics 2021Quote: ... The tip of the pipette was cut to an opening diameter between 1~ 5 μm and bent to ~40° using a microforge (DMF1000, WPI).
-
bioRxiv - Neuroscience 2024Quote: ... AAV viral vectors mixed with FastGreen for visualization (ratio 1:5) were injected using a PicoSpritzer (Cat. num. PV820, WPI) through pulled (P-30 puller ...
-
bioRxiv - Animal Behavior and Cognition 2022Quote: ... We accomplished this by having Varroa feed on pupae in which 3 μl of 1×107 DAPI microspheres in PBS buffer was injected (31 gauge needle, Micro4 microsyringe pump controller (World Precision Instruments, Sarasota, FL). A second group of pupae which served as a control were injected with PBS ...
-
bioRxiv - Physiology 2021Quote: ... juncea leaves with 100 nL ultra pure water containing 100 ng of dsIMPI or each 100 ng of dsPaGTR5/6/7/8 using a Nanoliter 2010 Injector (World Precision Instruments). A subset of the dsRNA-injected beetles were fed with detached leaves of Arabidopsis plants in plastic containers with moistened tissue for gene expression analysis (n = 6 replicates ...
-
bioRxiv - Neuroscience 2020Quote: ... 500 mM sucrose was applied directly on the dendritic field of the patched neurons at a puff pressure of 6–8 psi using a PV-820 Pneumatic Picopump system (World Precision Instruments). Receptor-mediated synaptic responses were pharmacologically isolated by applying drug combinations of 50 µM picrotoxin ...
-
bioRxiv - Cell Biology 2020Quote: Patch pipettes with a resistance of 4∼6 MΩ were made from borosilicate glass (World Precision Instruments) with a Sutter Instrument P-97 micropipette puller and filled with 1M NaCl solution ...
-
bioRxiv - Neuroscience 2020Quote: ... patch pipettes with a resistance of 4∼6 MΩ were made from borosilicate glass (World Precision Instruments) with a PC-10 Narishige puller and filled with a pipette solution containing the following (in mM) ...
-
bioRxiv - Cell Biology 2021Quote: ... Transendothelial electrical resistance (TER) was measured daily using an EVOM volt ohm meter equipped with STX-2 electrodes (World Precision Instruments, Sarasota, FL, USA) and electrical resistance calculated as previously described (Bartosova et al. ...
-
Validating Minimally Invasive Laser Doppler Flowmetry for Serial Bone Perfusion Measurements in MicebioRxiv - Bioengineering 2019Quote: ... was placed directly on the exposed bone surface (Fig. 2) and held in place using a micromanipulator (MM3-ALL, World Precision Instruments, Sarasota, FL) to reduce signal noise from probe movement ...
-
bioRxiv - Neuroscience 2021Quote: ... The pipette was filled from the back end with mineral oil and attached to a syringe needle mounted in a microinjection syringe pump (World Precision Instruments, UMP3T-2). Before injection ...
-
bioRxiv - Neuroscience 2022Quote: ... with a Gamry 600+ potentiostat (Gamry Instruments, Warminster, PA) (N=2 arrays) using previously published methods89.Silver ground and reference wires (AGT05100, World Precision Instruments, Sarasota, FL) were soldered to the PCB ...
-
bioRxiv - Neuroscience 2023Quote: ... the vagus nerve was mechanically stabilized on the micro-cuff electrode by applying a drop of 2-component silicone (Kwik-Sil, World Precision Instruments, Sarasota, FL) and then sectioned either caudal or rostral to the cuff ...
-
bioRxiv - Neuroscience 2023Quote: ... Infusions were made at a rate of 100 nL/min utilizing 29 Ga microinjection needles connected to FEP tubing secured to a 2 µl Hamilton syringe and a microinjection pump (UMP3, World Precision Instruments, Sarasota, FL). The infusion system was filled with distilled water and separated from the infused virus or drug by a small air bubble ...
-
bioRxiv - Neuroscience 2024Quote: ... the stock solution was further diluted to 0.6 mM with saline and 2 µl of the diluted solution was intracerebroventricularly administered after the control recording sessions using a NANOFIL micro-syringe (World Precision Instruments; FL, U.S.A.) and ultra-micro pomp (UMP3T-1 ...
-
bioRxiv - Systems Biology 2021Quote: ... 1 mM beta-glycerol phosphate and 5 mM of sodium orthovanadate) using a syringe pump (Aladdin AL-1000, World precision instruments). Livers and right kidneys were quickly removed and snap frozen in liquid nitrogen ...
-
bioRxiv - Bioengineering 2021Quote: ... The culture medium in the trachea lumen and within the chamber was refreshed via a syringe pump (flow rate: 5 mL.h-1; volume: 10 mL; AL-4000, World Precision Instruments) and a programmable pump (flow rate ...
-
bioRxiv - Bioengineering 2021Quote: ... the culture medium within the inner space of the trachea was replaced with the fresh medium once a day using a programmable syringe pump (flow rate: 5 mL.h-1; volume: 10 mL; AL-4000, World Precision Instruments) and the removed culture medium was collected in a waste reservoir ...
-
bioRxiv - Neuroscience 2023Quote: Intracortical injections were made at multiple sites (∼5-9 sites per cranial window, spaced 0.5-1 mm apart) using a microinjector (NanoFil, World Precision Instruments) fit with a 36G beveled needle (NF36BV-2 ...
-
bioRxiv - Neuroscience 2020Quote: ... The pulses repeated at 3 Hz for 10 s) by using a stimulus isolator (A365, WPI). The stimulation duration and frequency were triggered directly through the MRI scanner which controlled by Master-9 A.M.P.I system (Jerusalem ...
-
bioRxiv - Developmental Biology 2021Quote: ... Cells were patched using fire-polished 3–7 MΩ resistant borosilicate pipettes (World Precision Instruments, USA) and membrane currents and voltages were recorded in the whole-cell conFIGuration by a Digidata 1440A and a MultiClamp 700A amplifier ...
-
bioRxiv - Neuroscience 2023Quote: ... was then injected through a thin glass pipette with a micropump (UMP-3, World Precision Instruments). After injection ...
-
bioRxiv - Microbiology 2022Quote: Consumption of O2 was measured using an ISO-OXY-2 O2 sensor attached to an APOLLO 4000 free radical analyzer (World Precision Instruments, Inc., Sarasota, FL) as described52 ...
-
bioRxiv - Neuroscience 2023Quote: ... The space between the edges of the foil and the head capsule of the fly was sealed with 2-component silicon (Kwik-Sil™, World Precision Instruments, Sarasota, USA). A droplet of Ringer’s solution (NaCl ...
-
bioRxiv - Neuroscience 2023Quote: ... The virus (AAV1/2-OXTp-hM4Dgi-mCherry or AAV1/2-OXTp-Venus or AAV1/2-OXTp-mCherry) was loaded into a 20μl NanoFil syringe fitted with a 33gauge needle (cat no. NF33BL, World Precision Instruments Inc, Sarasota, FL, USA). A final volume of 270nl was injected into the PVH (A-P −1.7mm ...
-
bioRxiv - Neuroscience 2019Quote: ... and muscle cells were patched using fire-polished 4-6 MΩ resistant borosilicate pipettes (World Precision Instruments, USA). Membrane currents were recorded in the whole-cell configuration by a Digidata 1440A and a MultiClamp 700A amplifier ...
-
bioRxiv - Neuroscience 2022Quote: ... Recording pipettes (resistance of 4-6 MΩ) were pulled from thick-walled borosilicate glass capillaries (World Precision Instruments) and filled with high chloride internal solution (in mM ...
-
bioRxiv - Neuroscience 2023Quote: ... Anterior body wall muscle cells were patched using 4-6 MΩ resistant borosilicate pipettes (World Precision Instruments, USA), which were pulled by micropipette puller P-1000 (Sutter) ...
-
bioRxiv - Neuroscience 2022Quote: ... They were filled with a 1 M KCl solution using a MicroFil non-metallic syringe needle (MF 34G-5, World Precision Instruments); a few recordings were done with 3 M KCl (no particular change was noticed).
-
bioRxiv - Biophysics 2023Quote: ... using a Sutter P-97 puller and heat-polished to final resistances between 1 and 5 MΩ using a MF-200 microforge (World Precision Instruments). An agar bridge (1M KCl ...
-
bioRxiv - Neuroscience 2019Quote: ... was connected to a pneumatic injector (3–20 PSI, 10–90 s; Pneumatic Pump; World Precision Instruments). This set-up was used to load the somatosensory cortex with the Ca2+-sensitive dye Oregon Green Bapta (OGB-AM ...
-
bioRxiv - Neuroscience 2022Quote: ... which was positioned over the peroneal nerve using a 3-axis micromanipulator (KITE-R, World Precision Instruments). The micromanipulator was secured to an optical breadboard (MB1218 ...
-
bioRxiv - Pathology 2021Quote: ... body temperatures were measured using a thermocouple thermometer and mouse rectal probe (World Precision Instruments, RET-3). Blood glucose measurements were obtained with 2uL of tail vein blood analyzed with a Bayer CONTOUR Blood Glucose Monitor and Test Strips ...
-
bioRxiv - Neuroscience 2023Quote: ... 400nl of virus was delivered to 3 locations respectively by a microinjection system (Nanoliter 2010, WPI Ltd) through a craniotomy (<1 mm2) ...
-
bioRxiv - Neuroscience 2023Quote: ... mice were anesthetized with 3% isoflurane (Henry Schein) and transferred to a stereotaxic apparatus (World Precision Instruments). One burr hole was drilled above the left hippocampus (−2 mm anterior-posterior [A-P] to Bregma ...
-
bioRxiv - Genetics 2022Quote: ... The recording electrodes were HEPES-buffered extracellular saline-filled glass micropipettes (type 1B100F-3, World Precision Instruments) pulled with a Sutter P-87 micropipette puller ...
-
bioRxiv - Neuroscience 2023Quote: ... was injected at each site through a glass pipette and microsyringe pump (UMP-3, World Precision Instruments). After allowing at least ten minutes for viral diffusion ...
-
bioRxiv - Biophysics 2021Quote: ... to block or enhance a specific pathway the ear surface was gently cleaned and dried and a 4 µl solution containing a selected drug (Table 2) diluted in a PBS was microinjected in the earlobe skin using a 10 µl NANOFIL syringe (World Precision Instruments Inc., Sarasota, FL, USA) equipped with a gauge 33 needle ...
-
bioRxiv - Neuroscience 2023Quote: ... Recording electrodes (resistance 1-4 MΩ) were pulled from borosilicate glass (WPI, 1B120F-4) with a micropipette puller (Sutter Instruments ...
-
bioRxiv - Animal Behavior and Cognition 2023Quote: ... Recording electrodes (resistance 1-4 MΩ) were pulled from borosilicate glass (WPI, 1B120F-4) with a micropipette puller (NARISHIGE ...
-
bioRxiv - Animal Behavior and Cognition 2024Quote: ... REcording electrodes (resistance 1-4 MΩ) were pulled from borosilicate glass (WPI, 1B120F-4) with a micropipette puller (Sutter Instruments ...
-
bioRxiv - Neuroscience 2021Quote: ... The patch pipettes with a tip resistance of 4-6 MΩ were made of borosilicate glass (World Precision Instruments) with a Sutter pipette puller (P-97 ...