Labshake search
Citations for World Precision Instruments :
351 - 400 of 585 citations for 6H Dibenzo a g quinolizinium 5 8 13 13a tetrahydro 2 9 dihydroxy 3 10 dimethoxy 7 methyl 7S 13aS since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2023Quote: ... gap-free LFP recordings (15 minute duration) were obtained from the optic tectum using a single-glass microelectrode (WPI glass #TW150 F-3) with approximately 1 μM tip diameter backfilled with 2 mM NaCl internal solution as described previously 29,37–40 ...
-
bioRxiv - Neuroscience 2020Quote: ... Fisher Scientific) for 10 minutes using a peristaltic pump (5.5 ml/min; PeriStar Pro, WPI). Brains were post-fixated in paraformaldehyde with 30% sucrose for 1 h and then transferred to 30% sucrose in PBS for 18 h at 4°C ...
-
bioRxiv - Neuroscience 2020Quote: ... was infused (Pump 11 Elite Nanomite, Harvard Apparatus, using a 10 uL WPI Nanofil syringe) in 6 specular sites bilaterally ...
-
bioRxiv - Zoology 2020Quote: ... A recording electrode was maneuvered with a MPM-10 Piezo Translator (World Precision Instruments, USA) to the base of the sensillum to make a firm contact with the wall pore (wp ...
-
bioRxiv - Neuroscience 2020Quote: We used filamented borosilicate glass capillaries (OD 1.5mm, ID 0.86 mm, 10 cm length; WPI) and pulled patch pipettes from them using a Narishige PC-10 vertical puller ...
-
bioRxiv - Neuroscience 2023Quote: ... Viral injections were accomplished using a microinjection needle coupled with a 10 µl microsyringe (WPI). The virus was delivered at a controlled rate of 0.03 µl/min via a microsyringe pump (WPI) ...
-
bioRxiv - Biophysics 2022Quote: ... A micropipette was filled with fluorescently labeled protein using a MicroFil flexible needle (MF34G-5, World Precision Instruments, UK). The micropipettes were introduced in each side of the chamber and placed in the middle using micromanipulators ...
-
bioRxiv - Genetics 2023Quote: ... We performed the vector or vehicle (PBS with 0.001% PF68) delivery with an injection rate of 5 nL/s controlled by Nanoliter Microinjection Controller (WPI). The RWM niche was sealed with a small plug of muscle quickly after the injection ...
-
bioRxiv - Animal Behavior and Cognition 2022Quote: ... We accomplished this by having Varroa feed on pupae in which 3 μl of 1×107 DAPI microspheres in PBS buffer was injected (31 gauge needle, Micro4 microsyringe pump controller (World Precision Instruments, Sarasota, FL). A second group of pupae which served as a control were injected with PBS ...
-
Clemizole and Trazodone are Effective Antiseizure Treatments in a Zebrafish Model of STXBP1 DisorderbioRxiv - Neuroscience 2022Quote: ... gap-free local field potential recordings (LFP; 60 min duration) were obtained from optic tectum using a single glass microelectrode (WPI glass #TW150 F-3) filled with 2 mM NaCl internal solution (~1 μm tip diameter ...
-
bioRxiv - Neuroscience 2020Quote: ... Whole cell voltage and current-clamp recordings were performed at 32–34 °C with electrodes (3–5MΩ) pulled from borosilicate glass (World Precision Instruments, Sarasota, FL) filled with intracellular solution of the following composition (in mM) ...
-
bioRxiv - Neuroscience 2021Quote: ... gap-free local field potential recordings (LFP; 15 min duration) were obtained from optic tectum using a single glass microelectrode (WPI glass #TW150 F-3); ~ 1 μm tip diameter ...
-
bioRxiv - Bioengineering 2021Quote: ... New Jersey) and custom 3D-printed components was assembled around the animal to support a 3-axis micromanipulator (502600, World Precision Instruments, Sarasota, FL) and linear actuator (M-235.5DD ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch pipettes (3-6 MΩ) were pulled from standard borosilicate glass pipettes (thin-wall borosilicate tubes with filaments, World Precision Instruments, Sarasota, FL, USA) using a vertical puller (PC-10 ...
-
bioRxiv - Neuroscience 2023Quote: ... A circular piece of the skull (3 mm in diameter) centered over the injection was carefully cut out using a sharp drill (Ideal micro drill, World Precision Instruments, Berlin, Germany). The dura was removed with forceps and mild vacuum suction was used to slowly remove the cortex within the craniotomy ...
-
bioRxiv - Developmental Biology 2023Quote: ... Ventral longitudinal muscle 6 in abdominal segments 3 or 4 was impaled with two intracellular electrodes (1 mm outer diameter borosilicate capillaries; World Precision Instruments, 1B100F-4) of ∼15 MΩ resistance (3M KCl) ...
-
bioRxiv - Animal Behavior and Cognition 2024Quote: ... at least 3 days before the day of injection and the craniotomies were covered with silicone elastomer (Kwik-Cast, World Precision Instruments, FL, USA). Before injection ...
-
bioRxiv - Biophysics 2021Quote: ... The potential was measured using a Ag/AgCl mini-reference electrode (DRI-REF-2, World Precision Instruments) and a platinum working electrode (Scientific Glassblowing Service ...
-
bioRxiv - Neuroscience 2020Quote: ... a tungsten bipolar electrode (2-3μm-diameter tip) with resistance of 0.5 MΩ (TST33A05KT, World Precision Instruments) was inserted into layer 2/3 of Cg1/M2 ...
-
bioRxiv - Neuroscience 2021Quote: ... The caudal fin (2 mm of the end) was removed using dissecting scissors (WPI Inc., FL, USA) and placed into 1.5 ml collecting tubes ...
-
bioRxiv - Neuroscience 2021Quote: ... Animals were glued onto 2% agarose pads using Nexaband® veterinary glue (World Precision Instruments, Sarasota, Florida). Stimuli were applied by moving a capillary into the buffer close to the nose of the worm ...
-
bioRxiv - Bioengineering 2021Quote: ... TEER measurements were performed using an EVOM-2 and STX-100 electrodes (World Precision Instruments, Sarasota, FL). Monolayers with TEER > 1500 Ω cm2 were used for the permeability experiments ...
-
bioRxiv - Neuroscience 2022Quote: ... Recording glass pipettes with a tip of resistance of 1.5-2 MΩ (World Precision Instruments; Sarasota, FL) were filled with potassium-based intracellular solution (in mM) ...
-
bioRxiv - Neuroscience 2023Quote: ... Recording pipettes with resistances of 2-4 MΩ were pulled from borosilicate glass capillaries (World Precision Instruments). The pipette tip was filled with gramicidin-free KCl solution (140 mM KCl and 10 mM HEPES ...
-
bioRxiv - Neuroscience 2022Quote: ... The injection was performed with a blunt 33-gauge stainless steel needle (NF33BL-2, World Precision Instruments) and a 10 µL microinjection syringe (Nanofil ...
-
bioRxiv - Neuroscience 2023Quote: ... Viral vectors were infused using a microsyringe pump system (UMP3T-2; Nanofil with 33-Ga needles; WPI). A volume of 400 nL of the viral-containing medium was infused in each hemisphere at the target sites ...
-
bioRxiv - Physiology 2023Quote: ... The TEER was measured using STX-2 chopstick electrodes connected to an EVOM voltohmmeter (World Precision Instruments). 1 mg/ml 4 kDa fluorescein (FITC)-dextran was added to the apical (‘luminal’ ...
-
Treatment with furosemide indirectly increases inhibitory transmission in the developing hippocampusbioRxiv - Neuroscience 2023Quote: ... Recording pipetes with resistances of 2-4 MΩ were pulled from borosilicate glass capillaries (World Precision Instruments). The pipete tip was filled with gramicidin-free KCl solution (140 mM KCl and 10 mM HEPES ...
-
bioRxiv - Neuroscience 2021Quote: ... mice were anesthetized with isoflurane (induction, 5%; maintenance, 0.5 to 1.5%) and placed into a stereotaxic frame (World Precision Instruments). The body temperature was maintained at 36° C using a heating pad ...
-
bioRxiv - Microbiology 2019Quote: Zebrafish embryos staged at 24 hours post-fertilisation (hpf) were manually dechorionated using jeweller’s forceps (Dumont #5, World Precision Instruments), then infected at 28-30 hpf by caudal vein injection of Mm6 ...
-
bioRxiv - Biophysics 2020Quote: ... After punching a fluid port through the 5 mm thick Sylgard using 0.75 mm diameter biopsy punches (World Precision Instruments) the PDMS chip was bonded onto glass substrates using an 0.3 mbar ...
-
bioRxiv - Neuroscience 2022Quote: ... Pups were anesthetized under hypothermia and 5 pulses of 69 nL were injected into the V1 with a nanoliter injector (WPI). Four days later ...
-
bioRxiv - Biophysics 2021Quote: ... The tip of the pipette was cut to an opening diameter between 1~ 5 μm and bent to ~40° using a microforge (DMF1000, WPI).
-
bioRxiv - Biophysics 2019Quote: ... an excess amount of chloride cocktail (2-3 times the final volume of the liquid membrane) was delivered as close as possible to the micro-pipette tip using a 34G microneedle (Quickfil 34G-5, WPI, for which the polyimide coating was stripped from the end) ...
-
bioRxiv - Neuroscience 2022Quote: ... electrolytic lesions were obtained by passing positive and negative current (20-25 uA) on each electrode contact for 5 s with a stimulus isolator (A365RC, WPI) while the animal was under isofluorane-induced anesthesia ...
-
bioRxiv - Neuroscience 2024Quote: ... transfected slices were then transferred to the microscope chamber perfused with carbogen (95% O2 / 5% CO2)-bubbled recording aCSF maintained at approximately 30 - 34 °C by an in-line solution heater (WPI). The aCSF contained (in mM) ...
-
bioRxiv - Neuroscience 2024Quote: ... AAV viral vectors mixed with FastGreen for visualization (ratio 1:5) were injected using a PicoSpritzer (Cat. num. PV820, WPI) through pulled (P-30 puller ...
-
bioRxiv - Neuroscience 2023Quote: ... Cells expressing YFP and with a soma diameter <25 µm were targeted for whole cell recording using pipettes (∼5 MΩ resistance) pulled from borosilicate glass (WPI).
-
bioRxiv - Neuroscience 2019Quote: ... cone tipped 5μl stainless steel injector (SGE Analytical Science, Australia) over 3 min using an infusion pump (UMP3 with SYS4 Micro-controller, World Precision Instruments, Inc., FL, USA). The needle was left in place for 7 min to allow for diffusion and reduce spread up the infusion tract ...
-
bioRxiv - Neuroscience 2020Quote: Patch pipettes (3-6 MΩ resistance) were pulled from standard borosilicate glass pipettes (thin-wall borosilicate tubes with filaments, World Precision Instruments, Sarasota, FL, USA) using a vertical puller (PC-10 ...
-
bioRxiv - Neuroscience 2022Quote: Patch pipettes (3-6 MΩ resistance) were pulled from standard borosilicate glass pipettes (thin-wall borosilicate tubes with filaments, World Precision Instruments, Sarasota, FL, USA) using a vertical puller (PC-10 ...
-
bioRxiv - Neuroscience 2021Quote: Patch pipettes (3-6 MΩ resistance) were pulled from standard borosilicate glass pipettes (thin-wall borosilicate tubes with filaments, World Precision Instruments, Sarasota, FL, USA) using a vertical puller (PC-10 ...
-
bioRxiv - Neuroscience 2020Quote: ... cone tipped 5μl stainless steel injector (SGE Analytical Science, Australia) over 3 min using an infusion pump (UMP3 with SYS4 Micro-controller, World Precision Instruments, Inc., FL, USA). The needle was left in place for 7 min to allow for diffusion of and reduce spread up the infusion tract ...
-
bioRxiv - Pharmacology and Toxicology 2022Quote: Whole cell current- and voltage-clamp recordings were performed with pipettes (3-7MΩ when filled with intracellular solution) made from borosilicate glass capillaries (World Precision Instruments, Hitchin, Herts, UK) pulled on a P-97 Flaming/Brown micropipette puller (Sutter ...
-
bioRxiv - Neuroscience 2021Quote: ... A 10-µl Hamilton syringe connected to an UltraMicroPump and SYS-Mico4 controller (WPI, Sarasota, FL) was used to deliver 0.7 µl of AAV5-hSyn-hChR2(H134R)-eYFP (University of North Carolina vector core) ...
-
bioRxiv - Neuroscience 2021Quote: ... via a 10 μl Nanofil syringe and 33GA beveled needle (World Precision Instruments, Sarasota, FL, USA) at an infusion rate of 150 nL/min ...
-
bioRxiv - Genomics 2019Quote: ... and 10 mM HEPES) was used in conjunction with borosilicate glass patch pipettes (World Precision Instruments) with a resistance in the range of 2–6 MΩ ...
-
bioRxiv - Neuroscience 2020Quote: ... We injected mice with a beveled 33G needle attached to a 10 µL syringe (Nanofil, WPI) for delivery of 200 nL of viral reagent at a rate of 40 nL/min ...
-
bioRxiv - Physiology 2023Quote: ... Patch pipettes were pulled (PC-10, Narashige) from borosilicate glass tubes (TW150F-4, World Precision Instruments) and heat polished at the tip using a microforge (MF-200 ...
-
bioRxiv - Neuroscience 2023Quote: ... Viruses were loaded into a 10 µl 33G NanoFil syringe (World Precision Instruments, Sarasota, FL, USA) and 0.350 μl of the virus was injected into the VTA (A-P -5.6mm ...