Labshake search
Citations for World Precision Instruments :
51 - 100 of 299 citations for 6 tert Butylchromone 6 tert Butyl 4H chromene 4 one since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2022Quote: ... Oocytes were injected with 38.6 nL of Bgl-FaNaC encoding RNA at a concentration of 20 ng/uL using a Nanoliter 2000 microinjector (World Precision Instruments). Maximum expression levels were observed 6 days following injection.
-
bioRxiv - Cell Biology 2023Quote: ... from day 1 to day 6 of subculture of BMEC onto Transwells® using an EVOM2 Voltohmmeter/STX2 electrodes (World Precision Instruments). The STX2 electrode was positioned within the well and the resistance (Ω ...
-
bioRxiv - Neuroscience 2023Quote: ... The virus solution (0.4-0.6 µL) was injected at a rate of 2 nL/s with a microinjection pump (either Neurostar NanoW or WPI NanoLiter 2010). The pipette was slowly withdrawn at least 10 minutes after the completion of the injection ...
-
bioRxiv - Pharmacology and Toxicology 2019Quote: Micropipettes with a tip resistance of 3–6 MΩ were prepared from 1.2/0.69-mm OD/ID borosilicate glass capillaries (World Precision Instruments, GC-120F-10) using a pipette puller (Sutter Instruments ...
-
bioRxiv - Neuroscience 2020Quote: ... individual 7 µm diameter carbon fibres (Goodfellow Cambridge Limited, Cambridge, UK) were bundled and introduced into a pulled double borosilicate capillary (WPI, ref. TST150-6”) with ≃ 200 µm tip diameter and electrical impedance of 40-65 kΩ ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch pipettes (3-6 MΩ) were pulled from standard borosilicate glass pipettes (thin-wall borosilicate tubes with filaments, World Precision Instruments, Sarasota, FL, USA) using a vertical puller (PC-10 ...
-
bioRxiv - Microbiology 2021Quote: ... cRNA was micro-injected into stage 5 or 6 oocytes using a Micro4TM micro-syringe pump controller and A203XVY nanoliter injector (World Precision Instruments, Sarasota, FLA, U.S.A.). Oocytes were maintained in oocyte Ringer’s buffer with added gentamycin (50 μg/ml ...
-
bioRxiv - Physiology 2021Quote: Pronuclei of one-cell stage embryos were collected from superovulated donor females (B6/SJL strain) and microinjected with CRISPR/Cas9 constructs using micromanipulators and injection needles (World Precision Instruments, filament #1B100-6). Injected embryos were implanted into pseudopregnant recipient females according to NIH guidelines ...
-
bioRxiv - Neuroscience 2020Quote: Patch pipettes (3-6 MΩ resistance) were pulled from standard borosilicate glass pipettes (thin-wall borosilicate tubes with filaments, World Precision Instruments, Sarasota, FL, USA) using a vertical puller (PC-10 ...
-
bioRxiv - Neuroscience 2022Quote: Patch pipettes (3-6 MΩ resistance) were pulled from standard borosilicate glass pipettes (thin-wall borosilicate tubes with filaments, World Precision Instruments, Sarasota, FL, USA) using a vertical puller (PC-10 ...
-
bioRxiv - Neuroscience 2021Quote: Patch pipettes (3-6 MΩ resistance) were pulled from standard borosilicate glass pipettes (thin-wall borosilicate tubes with filaments, World Precision Instruments, Sarasota, FL, USA) using a vertical puller (PC-10 ...
-
bioRxiv - Neuroscience 2020Quote: ... We introduced one bipolar stimulating electrode (WPI, ref. TM53CCNON) in the perforant pathway (from bregma ...
-
bioRxiv - Biophysics 2022Quote: ... one end of the silver wires (diameter – 125 μm, WPI, USA) was melted over a fire flame to create a ball end ...
-
bioRxiv - Genomics 2023Quote: ... Embryos at the one-cell stage were injected (WPI Pneumatic PicoPump) with 1 nL of injection mix ...
-
bioRxiv - Immunology 2020Quote: 1.5 mm outer diameter and 1.12 mm inner diameter borosilicate glass capillaries were purchased from World Precision Instruments (WPI# TW150-4). We optimized fabrication procedures to obtain micropipettes with 2 μm diameter tips ...
-
bioRxiv - Neuroscience 2022Quote: ... filamented glass capillaries (4”, 1.0 mm outer diameter; World Precision Instruments, 1B100F-4) were pulled using a Sutter P-97 Flaming/Brown type micropipette puller using a custom program with the following parameters ...
-
bioRxiv - Neuroscience 2023Quote: ... Recording electrodes (resistance 1-4 MΩ) were pulled from borosilicate glass (WPI, 1B120F-4) with a micropipette puller (Sutter Instruments ...
-
bioRxiv - Animal Behavior and Cognition 2023Quote: ... Recording electrodes (resistance 1-4 MΩ) were pulled from borosilicate glass (WPI, 1B120F-4) with a micropipette puller (NARISHIGE ...
-
bioRxiv - Animal Behavior and Cognition 2024Quote: ... REcording electrodes (resistance 1-4 MΩ) were pulled from borosilicate glass (WPI, 1B120F-4) with a micropipette puller (Sutter Instruments ...
-
bioRxiv - Developmental Biology 2020Quote: ... Patch pipettes (1B150F-4, WPI) with a tip resistance of 5–8MΩ were filled with internal solution containing in mM ...
-
bioRxiv - Biochemistry 2019Quote: ... One day before transfection the cells were plated on 35 mm fluorodishes (World Precision Instruments) coated with 100 µg/mL poly-D-lysine (Sigma Aldrich ...
-
bioRxiv - Physiology 2022Quote: ... blood was sampled from the tail in borosilicate glass capillaries (1B100F-4 or 1B150F-4, WPI) and examined by a macroscope (Leica M205 FA ...
-
bioRxiv - Neuroscience 2022Quote: ... Borosilicate glass pipettes (WPI; 1B150F-4) were used to prepare patch electrodes (P-97 or P1000 ...
-
bioRxiv - Neuroscience 2020Quote: Borosilicate patch pipettes (1B150F-4, WPI), were pulled with a Flaming/Brown micropipette puller P-1000 (Sutter Instruments ...
-
bioRxiv - Neuroscience 2023Quote: ... Borosilicate patch pipettes (1B150F-4, WPI), were pulled with a Flaming/Brown micropipette puller P-1000 (Sutter Instruments ...
-
bioRxiv - Neuroscience 2023Quote: ... Blood was collected from the punctured site with borosilicate glass capillaries (1B100F-4 or 1B150F-4, WPI). Fluorescence of the blood samples was examined by a macroscope (Leica M205 FA ...
-
bioRxiv - Neuroscience 2023Quote: ... The Nanoject was attached to one of two micromanipulators (World Precision Instruments w/ Kantetec, Sarasota, FL), and the glass pipette was lowered to reach Field L ...
-
bioRxiv - Genetics 2023Quote: ... to pull 4-inch long thin wall filamented glass capillary tubes (TW100F-4, World Precision Instruments, Sarasota, FL) into injection needles using custom settings ...
-
bioRxiv - Developmental Biology 2021Quote: Glass capillaries (TW100F-4, World Precision Instruments) were pulled using a micropipette puller to obtain approximately 10μm diameter tubes ...
-
bioRxiv - Biophysics 2019Quote: ... borosilicate glass (#TW150F-4; WPI, Sarasota, FL), coated with Sylgard elastomer and fire polished to resistances of 2.5-7 Mn ...
-
bioRxiv - Bioengineering 2023Quote: ... 4 nl of the sample were delivered into the common cardinal vein using microcapillaries (TW100-4, World Precision Instruments), which were pulled using a Sutter P1000 needle puller.
-
bioRxiv - Neuroscience 2020Quote: ... Glass injection pipettes (World Precision Instruments, 1B100-4) were pulled using a Sutter P-2000 laser puller and beveled using a Narishige EG-45 grinder ...
-
bioRxiv - Physiology 2020Quote: ... A thinly pulled glass electrode (IB200F-4, WPI) back-billed with 500 mmol L-1 KCl was used as a reference ...
-
bioRxiv - Microbiology 2020Quote: ... and LabTrax 4-Channel Data Acquisition system (WPI). Finally ...
-
bioRxiv - Biophysics 2019Quote: Borosilicate capillary glasses (1B150F−4, World Precision Instruments) were pulled in a horizontal pipette puller (Sutter Instruments) ...
-
bioRxiv - Neuroscience 2023Quote: ... from borosilicate glass (1B200-4, WPI, Sarasota, FL). Pipettes for somatic recording had an impedance of 5-6 MΩ ...
-
bioRxiv - Genomics 2022Quote: ... Standard Glass Capillaries (1B100-4, World Precision Instruments) using a P-2000 needle puller (Sutter instruments) ...
-
bioRxiv - Cell Biology 2019Quote: Glass capillaries with an inner and outer diameter of 1 mm and 0.58 mm respectively (1B100-4 or 1B100F-4, World Precision Instruments) were used to create microneedles ...
-
Individual kinetochore-fibers locally dissipate force to maintain robust mammalian spindle structurebioRxiv - Cell Biology 2019Quote: Glass capillaries with an inner and outer diameter of 1 mm and 0.58 mm respectively (1B100-4 and 1B100F-4, World Precision Instruments) were used to create microneedles using a pipette puller (P-87 ...
-
bioRxiv - Neuroscience 2023Quote: ... Glass pipettes with a resistance of 2-4 MΩ were pulled from borosilicate glass capillaries (World Precision Instruments, Cat# TW150-4) using a PC-10 pipette puller (Narishige) ...
-
bioRxiv - Physiology 2019Quote: ... Ventilatory motor patterns were recorded from one of the abdominal nerve roots with a suction electrode (World Precision Instruments). The electrode was made from an unfilamented capillary tube 1 mm in diameter (World Precision Instruments ...
-
bioRxiv - Developmental Biology 2020Quote: ... One-cell-stage AB WT embryos were injected with gRNA and Ca9 mRNA with a Picopump (World Precision Instruments). Potential founders (F0 ...
-
bioRxiv - Neuroscience 2020Quote: ... 1 mm inner diameter borosilicate glass (WPI, 1B100F-4) was pulled with a multistep horizontal puller (P-1000 ...
-
bioRxiv - Physiology 2020Quote: ... glass capillaries (TW-150-4, World Precision Instruments (WPI), Sarasota ...
-
bioRxiv - Neuroscience 2021Quote: ... Glass capillaries (TW100F-4, World Precision Instruments, Sarasota, FL) were pulled to desired shape using a Sutter Inst ...
-
bioRxiv - Neuroscience 2022Quote: ... using a microinjector pump (UltraMicroPump3-4, World Precision Instruments). The needle was lowered over 1 min and remained in place for 1 min before infusion ...
-
bioRxiv - Neuroscience 2024Quote: ... Injections were performed with microinjector-controlled (micro-4, WPI) syringe (nanofil syringe and Nanofil 33G BVLD Needle ...
-
bioRxiv - Developmental Biology 2020Quote: ... A solution containing 25 ng/µL gRNA and 100 ng/µL Cas9 mRNA or 1000 ng/µL Cas9 protein (Toolgen) was injected into one-cell-stage embryos using a pneumatic microinjector (PV830, WPI). The insertion and/or deletion (indel ...
-
bioRxiv - Neuroscience 2022Quote: ... An incision was made over the eyelid of one eye and it was injected with CTB conjugated to Alexa-647 (Mol. Probes C34778) using a nanoliter injector (WPI). The animals were perfused with 4% PFA in PBS (0.01M ...
-
bioRxiv - Developmental Biology 2023Quote: ... A solution containing 25 ng/μL gRNA and 100 ng/μL Cas9 mRNA or 1000 ng/μL Cas9 protein (ToolGen Inc.) was injected into one-cell-stage embryos using a pneumatic microinjector (PV830, WPI). To establish the foxp1b mutant ...