Labshake search
Citations for World Precision Instruments :
351 - 400 of 481 citations for 6 N CARBETHOXY 3 CHLORO 7 8 DIHYDRO 5H PYRIDO 4 3 C PYRIDAZINE since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Biophysics 2023Quote: ... with resistances of 2-3.5 MΩ (Cat. #TW150F-4, World Precision Instruments, Sarasota, FL, USA). Voltage commands were applied with a MultiClamp 700B amplifier (Axon Instruments ...
-
bioRxiv - Neuroscience 2024Quote: Patch electrodes were created from 4in thin wall borosilicate glass (TW150F-4, World Precision Instruments) and pulled with a Narishige Model PC-10 were filled with the following (in mM ...
-
bioRxiv - Neuroscience 2020Quote: ... individual 7 µm diameter carbon fibres (Goodfellow Cambridge Limited, Cambridge, UK) were bundled and introduced into a pulled double borosilicate capillary (WPI, ref. TST150-6”) with ≃ 200 µm tip diameter and electrical impedance of 40-65 kΩ ...
-
bioRxiv - Neuroscience 2023Quote: ... Body temperature was maintained at 36 °C with a feedback-regulated heating pad (ATC 1000, WPI, Germany).
-
bioRxiv - Neuroscience 2023Quote: ... and body temperature was maintained at 37°C using a feedback-controlled warming device (World Precision Instruments, Animal Temperature Controller ...
-
bioRxiv - Neuroscience 2024Quote: ... The temperature of aCSF was kept at 30-34 °C by an in-line solution heater (WPI). A monopolar glass stimulation electrode ...
-
bioRxiv - Neuroscience 2022Quote: ... +2.2 mm ML from bregma) using a MicroSyringe Pump Controller Micro 4 (World Precision Instruments, WPI) at a rate of 30 nl/min ...
-
bioRxiv - Neuroscience 2022Quote: ... +2.2 mm ML from bregma) using a MicroSyringe Pump Controller Micro 4 (World Precision Instruments, WPI) at a rate of 30 nl/min ...
-
bioRxiv - Neuroscience 2020Quote: Pipettes for patch clamp recordings were pulled from borosilicate thin glass capillaries (TW150-4, WPI, USA) and filled with a filtered intracellular solution with the following composition (mM) ...
-
bioRxiv - Neuroscience 2020Quote: ... (4) conduction velocity – A 2.0 MΩ Parylene-coated tungsten metal stimulating electrode (TM33B20, World Precision Instruments) was positioned within the RF of interest ...
-
bioRxiv - Cell Biology 2021Quote: ... the patch pipettes were pulled from borosilicate glass capillary tubes (World Precision Instruments, Cat# TW150-4) using a PC-10 pipette puller (Narishige) ...
-
bioRxiv - Neuroscience 2022Quote: Pipettes filled with 4% LY PBS solution were mounted on a microelectrode holder (WPI, PE MEH710), which was fixed on a 3-D adjustable micromanipulor (Scientifica ...
-
bioRxiv - Physiology 2019Quote: ... Filamented borosilicate glass capillaries (1 mm diameter; 1B100-F-4, World Precision Instruments, Sarasota, Florida, USA) were pulled to low tip resistance (5-7 MΩ ...
-
bioRxiv - Physiology 2021Quote: ... Reference electrodes (5-10 megaohms) were pulled using filamented capillaries (1B100F-4, World Precision Instruments, USA) and back-filled with 1 M KCl ...
-
bioRxiv - Neuroscience 2020Quote: ... 4~5 MΩ for whole-cell recording) were pulled from borosilicate capillary glass (World Precision Instruments) with a Stutter P-97 horizontal puller ...
-
bioRxiv - Neuroscience 2021Quote: ... AAV virus was injected with a glass pipette using an infusion pump (Micro 4, WPI, USA). Viruses were injected bilaterally into target brain areas using the following coordinates ...
-
bioRxiv - Neuroscience 2022Quote: ... Glass recording electrodes (outer diameter 1.5 mm, inner diameter 0.84 mm, World Precision Instruments 1B150F-4) were pulled using a vertical puller (Narishige ...
-
bioRxiv - Physiology 2023Quote: ... Patch pipettes were pulled (PC-10, Narashige) from borosilicate glass tubes (TW150F-4, World Precision Instruments) and heat polished at the tip using a microforge (MF-200 ...
-
bioRxiv - Neuroscience 2023Quote: ... mice were initially anesthetized with 4% isoflurane and fixed in a stereotaxic frame (#504926, WPI, Germany) at 2% isoflurane ...
-
bioRxiv - Plant Biology 2023Quote: ... The measured data were acquired by a Lab-Trax-4 device (World Precision Instruments, Sarasota, USA) working with LabScribe2 software ...
-
bioRxiv - Physiology 2023Quote: ... The final injection mix was loaded using a pulled capillary needle (1B100F-4, World Precision Instruments) and injected into the germline of N2 young adults ...
-
bioRxiv - Neuroscience 2023Quote: ... Whole-cell recordings from these cells were obtained with glass pipettes (World Precision Instruments 1B150F-4) filled with a solution containing (in mM ...
-
bioRxiv - Physiology 2024Quote: ... Ion-selective electrodes were fashioned from borosilicate glass (TW150-4; World Precision Instruments, Sarasota, FL, USA), pulled on a Flaming-Brown P-1000 micropipette puller (Sutter Instruments ...
-
bioRxiv - Neuroscience 2020Quote: ... A heating pad was used to maintain body temperature at 37 °C (ATC 1000, World Precision Instruments, Florida). Subsequently ...
-
bioRxiv - Neuroscience 2021Quote: ... 1.5% maintenance) and body temperature was maintained at 37.5°C using a temperature controller (ATC2000, World Precision Instruments). Animals were dosed with slow-release buprenorphine (0.1mg/kg ...
-
bioRxiv - Bioengineering 2020Quote: ... Recordings were performed in dim light at 32 °C with a sharp metal electrode (PTM23BO5KT, World Precision Instruments), amplified (Model 3000 ...
-
bioRxiv - Immunology 2024Quote: ... The serosa was kept at a temperature of 36 °C using an adjustable heater (WPI; Air-Therm SMT). For some animals control baseline recording was performed before adding the respective stimuli (M-CSF) ...
-
bioRxiv - Neuroscience 2024Quote: ... The body temperature was continuously monitored and maintained at 37°C using a heating pad (WPI, ATC-2000). A typical imaging session lasted 2-3 hours ...
-
bioRxiv - Microbiology 2021Quote: ... cRNA was micro-injected into stage 5 or 6 oocytes using a Micro4TM micro-syringe pump controller and A203XVY nanoliter injector (World Precision Instruments, Sarasota, FLA, U.S.A.). Oocytes were maintained in oocyte Ringer’s buffer with added gentamycin (50 μg/ml ...
-
bioRxiv - Physiology 2021Quote: Pronuclei of one-cell stage embryos were collected from superovulated donor females (B6/SJL strain) and microinjected with CRISPR/Cas9 constructs using micromanipulators and injection needles (World Precision Instruments, filament #1B100-6). Injected embryos were implanted into pseudopregnant recipient females according to NIH guidelines ...
-
bioRxiv - Neuroscience 2020Quote: Patch clamp pipettes were pulled from borosilicate capillaries (1B120F-4, World Precision Instruments, Inc., Sarasota, FL, USA) with a horizontal puller (P-87 ...
-
bioRxiv - Biophysics 2019Quote: ... An ACSF-filled glass pipette (opening diameter 10-30 µm, 1B120F-4, World Precision Instruments, Sarasota, FL) was used for Schaffer collateral nerve stimulations ...
-
bioRxiv - Pharmacology and Toxicology 2019Quote: ... Microinjection needles were created from glass capillary tubes (058 mm inner diameter; World Precision Instruments, 1B100F-4) using a pipette puller (Sutter instrument model p-30 ...
-
bioRxiv - Neuroscience 2023Quote: ... Recording pipettes with resistances of 2-4 MΩ were pulled from borosilicate glass capillaries (World Precision Instruments). The pipette tip was filled with gramicidin-free KCl solution (140 mM KCl and 10 mM HEPES ...
-
bioRxiv - Neuroscience 2022Quote: ... and controlled by a micromanipulator connected to a pneumatic picopump (4 psi, World Precision Instruments, SYS-PV820). Constant circulation of aCSF was maintained in the dish during the recording ...
-
Serotonergic Modulation of Spinal Circuitry Restores Motor Function after Chronic Spinal Cord InjurybioRxiv - Neuroscience 2023Quote: ... The junction was secured using 4-0 silk suture and liquid silicone (World Precision Instruments, Kwik-Sil). Note that an additional small incision was made above the cannula-implant site to expose the proximal (or silicone ...
-
bioRxiv - Neuroscience 2023Quote: Patch pipettes with 4.5-6.5 MΩ tip resistance were prepared from borosilicate glass capillaries (TW150F-4, WPI) using micropipette pullers (HEKA PIP 6 and MDI PMP102) ...
-
bioRxiv - Cell Biology 2023Quote: ... Microinjection was performed using borosilicate glass capillaries (4 inches, OD 1.0 mm, World Precision Instruments, FL, USA). 200-250 HeLa cells transfected with si-NC or si-METTL3 at a concentration of 25 nM were injected directly into the middle of the yolk sac of the larva ...
-
bioRxiv - Neuroscience 2023Quote: ... followed by AAV injections using a micro-syringe connected to a micropump (UltraMicroPump 4, WPI surgical instruments), which was lowered into the brain until it reached the DV coordinates (see below for details) ...
-
bioRxiv - Biochemistry 2023Quote: ... The samples were electrosprayed from gold-coated borosilicate glass capillaries Kwik-Fil 1B120F-4 (World Precision Instruments) prepared in-house essentially as described before (49 ...
-
bioRxiv - Developmental Biology 2024Quote: ... with needles pulled using a Model P-1000 Flaming Brown Micropipette Puller (World Precision Instruments, TW100F-4). Needles were cut to yield an injection volume of ∼1nL.
-
Treatment with furosemide indirectly increases inhibitory transmission in the developing hippocampusbioRxiv - Neuroscience 2023Quote: ... Recording pipetes with resistances of 2-4 MΩ were pulled from borosilicate glass capillaries (World Precision Instruments). The pipete tip was filled with gramicidin-free KCl solution (140 mM KCl and 10 mM HEPES ...
-
bioRxiv - Biophysics 2020Quote: ... Measurements start 15 minutes after treatment and cells are kept at 37 °C using a heater (World Precision Instruments) in a custom-built environmental chamber during all optical trapping experiments.
-
bioRxiv - Neuroscience 2019Quote: ... a single slice was transferred to a heated chamber (32 °C) and perfused with normal ACSF (2.5 ml min−1) using a peristaltic pump (WPI). Visualization of neurons in the pyramidal layer of hippocampal CA1 was performed with an upright microscope equipped for differential interference contrast (DIC ...
-
bioRxiv - Neuroscience 2020Quote: ... Core body temperature was maintained at 37–38 °C using a feedback-controlled heating pad (ATC2000, World Precision Instruments). The stimulated contralateral eye was kept lubricated by a thin layer of silicone oil ...
-
bioRxiv - Neuroscience 2022Quote: ... The body temperature was monitored and maintained at 37°C using a temperature controller (ATC-2000, World Precision Instruments). An incision was made along the midline to expose the skull after the head was fixed in a stereotaxic apparatus ...
-
bioRxiv - Neuroscience 2023Quote: ... 2A-C which used 10-60 μA) were generated by triggering a stimulus isolator (World Precision Instruments, Sarasota, Florida) and applied via fire-polished ...
-
bioRxiv - Immunology 2023Quote: ... Animals were placed on a temperature-controlled (37°C) heating pad (World Precision Instruments T-2000, Sarasota, FL, USA) during auditory testing inside a noise-cancelling chamber (Acoustic Systems ...
-
bioRxiv - Neuroscience 2022Quote: ... Patch electrodes (final resistance 2–4 MΩ) were pulled from borosilicate glass (World Precision Instruments, Sarasota, FL, USA). The intracellular solution contained (in mM) ...
-
bioRxiv - Neuroscience 2020Quote: ... The glass pipette consisted of 5 barrels in an H configuration (World Precision Instruments, catalogue no. 5B120F-4) with the tip broken to a diameter of 30–40 μm [37] ...