Labshake search
Citations for World Precision Instruments :
351 - 400 of 679 citations for 6 Methyl 3 4 dihydro 2H pyrido 3 2 b 1 4 oxazine since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2024Quote: ... dorsoventral from the brain surface [DV] 1.9 mm) at a speed of 50 nL/min using a UMP3 pump regulated by Micro-4 (World Precision Instruments). For the optogenetic silencing experiments (Figure 1H–N) ...
-
bioRxiv - Cell Biology 2023Quote: ... thin wall glass capillaries (1 mm outer diameter, 0.78 mm inner diameter; World Precision Instruments, TW100F-6) were pulled using a P-97 micropipette puller (Sutter Instruments ...
-
Clemizole and Trazodone are Effective Antiseizure Treatments in a Zebrafish Model of STXBP1 DisorderbioRxiv - Neuroscience 2022Quote: ... gap-free local field potential recordings (LFP; 60 min duration) were obtained from optic tectum using a single glass microelectrode (WPI glass #TW150 F-3) filled with 2 mM NaCl internal solution (~1 μm tip diameter ...
-
bioRxiv - Neuroscience 2020Quote: ... Whole cell voltage and current-clamp recordings were performed at 32–34 °C with electrodes (3–5MΩ) pulled from borosilicate glass (World Precision Instruments, Sarasota, FL) filled with intracellular solution of the following composition (in mM) ...
-
bioRxiv - Neuroscience 2021Quote: ... gap-free local field potential recordings (LFP; 15 min duration) were obtained from optic tectum using a single glass microelectrode (WPI glass #TW150 F-3); ~ 1 μm tip diameter ...
-
bioRxiv - Bioengineering 2021Quote: ... New Jersey) and custom 3D-printed components was assembled around the animal to support a 3-axis micromanipulator (502600, World Precision Instruments, Sarasota, FL) and linear actuator (M-235.5DD ...
-
bioRxiv - Neuroscience 2023Quote: ... A circular piece of the skull (3 mm in diameter) centered over the injection was carefully cut out using a sharp drill (Ideal micro drill, World Precision Instruments, Berlin, Germany). The dura was removed with forceps and mild vacuum suction was used to slowly remove the cortex within the craniotomy ...
-
bioRxiv - Animal Behavior and Cognition 2024Quote: ... at least 3 days before the day of injection and the craniotomies were covered with silicone elastomer (Kwik-Cast, World Precision Instruments, FL, USA). Before injection ...
-
bioRxiv - Cancer Biology 2019Quote: Melanoma cells were injected into the circulation of 2dpf larvae with a microinjection apparatus and needles were pulled from capillaries (TW100-4, World precision instruments). Transplanted larvae were kept overnight at 28ºC in embryo media ...
-
bioRxiv - Neuroscience 2021Quote: ... 200 nl of 1:1 mixture of AAV5 CAG-FLEx-TCb and AAV8 CAG-FLEx-RG was injected into the PVH at a speed of 50 nl/min using a UMP3 pump regulated by Micro-4 (World Precision Instruments). For local circuit mapping (Fig ...
-
bioRxiv - Neuroscience 2019Quote: ... TdTomato-expressing (Vglut3lineage) dissociated DRG neurons and HEK cells were performed with patch pipettes pulled from standard borosilicate glass (1B150F-4, World Precision Instruments) with a P-97 puller (Sutter Instruments) ...
-
bioRxiv - Neuroscience 2021Quote: ... Virus was injected at a rate of 40 μl/min controlled via a microsyringe pump (UltraMicroPump3–4; World Precision Instruments, Sarasota, FL). Upon recovery ...
-
Prelimbic proBDNF facilitates memory destabilization by regulation of neuronal function in juvenilesbioRxiv - Neuroscience 2022Quote: ... which was arrayed into a 4×8 matrix using 25-μm-diameter tungsten wires (California Fine Wires) in a 35-gauge silica tube (World Precision Instruments). A cannula was attached to a silica tube ...
-
bioRxiv - Neuroscience 2022Quote: ... 0.5-inch-long needle attached to a 5 µl Hamilton syringe was mounted to the stereotaxic frame and controlled using a Micro 4 Microsyringe Pump (World Precision Instruments) to infuse 0.5 µl AAV2/PHP.eB-hGfaABC1D-DIO-hTDP43-WT (1.2 × 1013 particles/µl) ...
-
bioRxiv - Neuroscience 2022Quote: Pipettes for patch clamping were prepared freshly on the day of electrophysiology experiments from filamented glass capillaries (1B150F-4, World Precision Instruments) using a horizontal pipette puller (P1000 ...
-
bioRxiv - Neuroscience 2023Quote: ... A total of 250 nL AAV was dispensed at each cortical layer through a glass-capillary-attached Hamilton syringe at a rate of 40 nL/min using a UltraMicroPump-4 system (World Precision Instruments). To image UDP in hippocampus ...
-
bioRxiv - Neuroscience 2023Quote: ... 250 nL of either AAV serotype 9 OTp-mCherry was bilaterally injected into the PVH and the supraoptic nucleus at a speed of 50 nL/min using a UMP3 pump regulated by Micro-4 (World Precision Instruments).
-
bioRxiv - Neuroscience 2023Quote: ... 250 nL of either AAV8 hSyn-DIO-hM3Dq-mCherry or AAV5 hSyn-DIO-mCherry was bilaterally injected into the PVH at a speed of 50 nL/min using a UMP3 pump regulated by Micro-4 (World Precision Instruments). The coordinates for injection into the supraoptic nucleus were as follows ...
-
bioRxiv - Molecular Biology 2024Quote: ... PRV-CAG-EGFP (BrainVTA, Cat. P03001) was injected into unilateral inguinal WAT (4 × 200 nL) using a 36-gauge beveled needle (WPI, Cat. NF36BV). After the injection ...
-
bioRxiv - Neuroscience 2019Quote: ... cone tipped 5μl stainless steel injector (SGE Analytical Science, Australia) over 3 min using an infusion pump (UMP3 with SYS4 Micro-controller, World Precision Instruments, Inc., FL, USA). The needle was left in place for 7 min to allow for diffusion and reduce spread up the infusion tract ...
-
bioRxiv - Neuroscience 2020Quote: ... cone tipped 5μl stainless steel injector (SGE Analytical Science, Australia) over 3 min using an infusion pump (UMP3 with SYS4 Micro-controller, World Precision Instruments, Inc., FL, USA). The needle was left in place for 7 min to allow for diffusion of and reduce spread up the infusion tract ...
-
bioRxiv - Pharmacology and Toxicology 2022Quote: Whole cell current- and voltage-clamp recordings were performed with pipettes (3-7MΩ when filled with intracellular solution) made from borosilicate glass capillaries (World Precision Instruments, Hitchin, Herts, UK) pulled on a P-97 Flaming/Brown micropipette puller (Sutter ...
-
bioRxiv - Pharmacology and Toxicology 2021Quote: Freshly isolated PAs were cannulated with glass micropipettes (6 in, 1.2 mm OD; 1B120-6, World Precision Instruments) bathed with 37 °C PSS (PSS0Caplus 1.6 mM CaCl2 and without EDTA ...
-
bioRxiv - Cell Biology 2020Quote: ... and stiff pulling pipette (WPI TW100-6) were used for stretching chromosomes ...
-
bioRxiv - Biophysics 2020Quote: ... The signal from the force transducer was amplified using Transbridge TBM4M and digitized using Lab-Trax-4 data acquisition hardware (WPI, Sarasota, FL, USA). Three phases could be distinguished on force curves recorded using LabScribe v3 (iWorks ...
-
bioRxiv - Microbiology 2020Quote: The permeability of the differentiated epithelial layer (after 4 weeks of differentiation) was determined by measuring the TEER using an epithelial volt-ohm meter (EVOM2, World Precision Instruments, Inc.). The EVOM2 was calibrated according to the manufacturer’s instructions ...
-
bioRxiv - Neuroscience 2023Quote: ... The virus was injected via a pulled needle of a borosilicate glass capillary (ID: 0.68mm, OD: 1.2mm; Kwik-fill, World Precision Instruments Inc., # 1B150F-4) that was angled at 50° to the slice using a stereotactic micromanipulator (SM-11 ...
-
bioRxiv - Neuroscience 2023Quote: ... Triturations were carried out using two sequential bore diameters (∼300μm and ∼150μm) of fire-polished glass capillaries (World Precision Instruments; Sarasota, FL, Item No. TW100-3). A total of six triturations were used for female mice and twelve triturations for male mice ...
-
bioRxiv - Cell Biology 2021Quote: ... and grown with daily media changes until the transepithelial resistance reached 400 ohm/cm2 (4–5 days) measured with an EVOM electrometer (World Precision Instruments, Sarasota, FL).
-
bioRxiv - Neuroscience 2022Quote: ... A standard micropipette injection protocol was used to make all injections into the brain or spinal cord using pulled borosilicate glass micropipettes (WPI, Sarasota, FL, #1B100-4) that were ground to a 35° beveled tip with 150–250 μm inner diameter ...
-
bioRxiv - Bioengineering 2020Quote: MC3T3-E1 Subclone 4 (ATCC® CRL-2593™) preosteoblastic cells were cultured on duplicate samples of tissue-cultured polystyrene (Fluorodish, World Precision Instruments) and commercially available argon-treated BC (CoArBC) ...
-
bioRxiv - Genetics 2019Quote: ... repair templates and nuclease-free water were added to the mixtures and loaded into pulled injection needles (1B100F-4, World Precision Instruments, Sarasota, FL). Individual injected P0 animals were transferred to new 6 cm NGM plates approximately 18 hours after injections ...
-
bioRxiv - Biophysics 2023Quote: ... A standard micropipette injection protocol was used to make all injections into the brain using pulled borosilicate glass micropipettes (WPI, Sarasota, FL, #1B100-4) that were ground to a 35° beveled tip with 150–250 μm inner diameter ...
-
bioRxiv - Cell Biology 2020Quote: An easily bent force pipette (WPI TW100F-6), and stiff pulling pipette (WPI TW100-6 ...
-
bioRxiv - Neuroscience 2023Quote: ... and 26-gauge needle (Hamilton) at a flow rate of 100 nl/min driven by a microsyringe pump controller (World Precision Instruments, model Micro 4). The syringe needle was left in place for 10 min and was completely withdrawn 17 min after viral delivery ...
-
bioRxiv - Neuroscience 2023Quote: ... Recording pipettes (10-15 MΩ) were pulled from borosilicate capillary glass (BF150-86-10, Sutter Instruments, Novato, USA or 1B150F-4, World Precision Instruments, Sarasota, USA) in a horizontal pipette puller (P-1000 Micropipette puller ...
-
bioRxiv - Genetics 2023Quote: ... 0.5nl of the mixtures were directly injected into the yolk of freshly layed zygotes using a glass capillary needle [TW120-4) (Kwik-Fil, World Precision Instruments, Inc., Hertfordshire, UK)] with the help of a pedal controlled microinjector (PV820 Pneumatic PicoPump ...
-
bioRxiv - Neuroscience 2023Quote: ... Isoflurane (1-2%) mixed with oxygen was delivered through a nose cone (WPI). Buprenex® (buprenorphine ...
-
bioRxiv - Pharmacology and Toxicology 2023Quote: ... SM preparations were fixed between a stationary stainless steel hook and an isometric force transducer (AE 801, SensoNor A/S, Norten, Norway) coupled to an AD converter Lab-Trax 4/16 (World Precision Instruments, Inc., Sarasota, FL, USA). The data were continuously recorded using DataTrax2 (World Precision Instruments ...
-
bioRxiv - Neuroscience 2024Quote: ... we applied 1-s pressure pulses (0.4-0.6 psi) every 2 s for 1 min by a microinjector (PV850, World Precision Instruments). In some experiments ...
-
bioRxiv - Pharmacology and Toxicology 2021Quote: ... The vessels were repositioned to display all branches without overlap using a glass capillary (6 in, 1.2 mm OD; 1B120-6, World Precision Instruments, Sarasota, FL) thinned with a micropipette puller (Narishige ...
-
bioRxiv - Cell Biology 2023Quote: ... from day 1 to day 6 of subculture of BMEC onto Transwells® using an EVOM2 Voltohmmeter/STX2 electrodes (World Precision Instruments). The STX2 electrode was positioned within the well and the resistance (Ω ...
-
bioRxiv - Plant Biology 2023Quote: ... Borosilicate glass capillaries (1B150F-6, World Precision Instruments, Sarasota, USA) were used to make micropipettes with the use of a P-30 micropipette puller (Shutter Instrument Co. ...
-
bioRxiv - Neuroscience 2020Quote: ... Current pulses were delivered via a constant current source (model 305-B, World Precision Instruments). A stimulus generator (A310 Accupulser ...
-
bioRxiv - Cell Biology 2019Quote: ... loose chromosome was grabbed by the force pipette (WPI TW100F-6), moved from the bundle and grabbed with the pulling pipette on the other end ...
-
bioRxiv - Biochemistry 2024Quote: ... Snails were injected using glass capillary needles (World Precision Instruments, 1B100F-6) pulled to an opening size of approximately 100 µm with a Model P-87 Sutter Instrument Micropipette Puller ...
-
bioRxiv - Neuroscience 2020Quote: ... Row B barrels were injected with viral vectors (40 nl/barrel) using a nanoliter injector (Nanoliter 2010, WPI) ended with a glass capillary backfilled with paraffin oil (catalog ...
-
bioRxiv - Neuroscience 2022Quote: ... between two custom-made suction electrodes (1.5 mm, #1B150-6, World Precision Instruments) and kept superfused with artificial cerebrospinal fluid (aCSF) ...
-
bioRxiv - Neuroscience 2023Quote: ... These were pulled from TW150F-6 micropipettes (World Precision Instruments Inc., Sarasota, FL) on a horizontal Flaming/Brown micropipette puller (Model P-87 ...
-
bioRxiv - Neuroscience 2023Quote: ... 1010 gc AAV8 in 1-2 μl was stereotactically injected with 15 nl/sec using a microinjection system (Nanoliter 2010, WPI) at (X ...