Labshake search
Citations for World Precision Instruments :
201 - 250 of 419 citations for 6 Chloro N 5 ethoxy 1H pyrazol 3 yl 3 nitropyridin 2 amine since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2023Quote: ... cells were patched using 4-6 MΩ-resistant borosilicate pipettes (1B100F-4, World Precision Instruments, USA). Pipettes were pulled by micropipette puller P-1000 (Sutter ...
-
bioRxiv - Bioengineering 2023Quote: ... Using 2 syringe pumps (WPI, AL-1000), an interstitial flow was created by applying different flow rates (Q1=334 μl min-1 and Q2=10 μl min-1 ...
-
bioRxiv - Neuroscience 2023Quote: ... with 35G bevelled needles (WPI, NF35BV-2) was filled ...
-
bioRxiv - Cell Biology 2020Quote: Patch pipettes with a resistance of 4∼6 MΩ were made from borosilicate glass (World Precision Instruments) with a Sutter Instrument P-97 micropipette puller and filled with 1M NaCl solution ...
-
bioRxiv - Neuroscience 2020Quote: ... patch pipettes with a resistance of 4∼6 MΩ were made from borosilicate glass (World Precision Instruments) with a PC-10 Narishige puller and filled with a pipette solution containing the following (in mM) ...
-
bioRxiv - Cell Biology 2023Quote: ... thin wall glass capillaries (1 mm outer diameter, 0.78 mm inner diameter; World Precision Instruments, TW100F-6) were pulled using a P-97 micropipette puller (Sutter Instruments ...
-
bioRxiv - Neuroscience 2020Quote: ... Infusions were delivered via 2 μl syringe (Hamilton, Neuros) controlled by a microsyringe pump (World Precision Instruments, UMP3-2). Infusion rate was ~0.11 μl/min ...
-
bioRxiv - Neuroscience 2020Quote: ... Infusions were delivered via 2 μl syringe (Hamilton, Neuros) controlled by a microsyringe pump (World Precision Instruments, UMP3-2). Infusion rate was ~0.11 μl/min ...
-
bioRxiv - Neuroscience 2019Quote: ... and muscle cells were patched using fire-polished 4-6 MΩ resistant borosilicate pipettes (World Precision Instruments, USA). Membrane currents were recorded in the whole-cell configuration by a Digidata 1440A and a MultiClamp 700A amplifier ...
-
bioRxiv - Cell Biology 2020Quote: ... Trans-epithelial electrical resistance (TEER) was measured using an EVOM2 and ENDOHM 6 mm chamber (World Precision Instruments).
-
bioRxiv - Neuroscience 2022Quote: ... Recording pipettes (resistance of 4-6 MΩ) were pulled from thick-walled borosilicate glass capillaries (World Precision Instruments) and filled with high chloride internal solution (in mM ...
-
bioRxiv - Neuroscience 2023Quote: ... Anterior body wall muscle cells were patched using 4-6 MΩ resistant borosilicate pipettes (World Precision Instruments, USA), which were pulled by micropipette puller P-1000 (Sutter) ...
-
bioRxiv - Neuroscience 2019Quote: ... 2 CaCl2.2H2O at a rate of 2 ml/min using a perfusion pump (PeriStar Pro; World Precision Instruments, Sarasota, FL). For current clamp recordings of intrinsic membrane properties and current-injected firing ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch pipettes (1.5 – 2 MΩ) (World Precision Instruments) were made using a pipette puller (Narishige ...
-
bioRxiv - Immunology 2020Quote: Micropipettes were filled with PBS using MicroFil (WPI #MF28G-5) and syringe ...
-
bioRxiv - Neuroscience 2021Quote: ... The patch pipettes with a tip resistance of 4-6 MΩ were made of borosilicate glass (World Precision Instruments) with a Sutter pipette puller (P-97 ...
-
bioRxiv - Neuroscience 2020Quote: ... The patch pipettes with a tip resistance of 4-6 MΩ were made of borosilicate glass (World Precision Instruments) with a Sutter pipette puller (P-97 ...
-
bioRxiv - Neuroscience 2020Quote: ... and anterior muscle cells were patched using fire-polished 4−6 MΩ resistant borosilicate pipettes (World Precision Instruments, USA). Membrane currents were recorded in the whole-cell configuration by HEKA EPC-9 patch clamp amplifier ...
-
bioRxiv - Neuroscience 2022Quote: ... a subgroup of mice (6 NaCl, 9 KA) were implanted with wire electrodes (platinum-iridum, teflon-insulated, Ø125μm, WPI) into the dentate gyrus (DG ...
-
bioRxiv - Biophysics 2020Quote: ... The resulting 1D channels of 5 μm height and 5 μm width were sealed in 35-mm glass bottomed cell culture dishes (World Precision Instruments, Sarasota, FL, USA) using plasma surface activation ...
-
bioRxiv - Biophysics 2019Quote: ... The resultant channels of 5 μm height and 5 μm width was attached in 35mm glass bottom cell culture dishes (World Precision Instruments, Sarasota, FL, USA) by plasma surface activation ...
-
bioRxiv - Biophysics 2019Quote: ... we used cyanoacrylate to rigidly attach the anterior phragma to a cantilever beam force transducer rated to 10 N with a resonance frequency of 300 Hz (FORT1000, World Precision Instruments, Sarasota, FL). The force transducer itself was mounted to a 3-axis micromanipulator ...
-
bioRxiv - Biophysics 2022Quote: ... The scutum mount was rigidly attached to a 10 N force transducer with a resonant frequency of 300 Hz (FORT1000, World Precision Instruments, Sarasota FL), and the posterior phragma mount was rigidly attached to the shaker head ...
-
bioRxiv - Neuroscience 2021Quote: ... a volume of 300 nL of AAV9-cFos-tTa + TRE-EYFP viral cocktail was bilaterally injected at 200 nL/min using a micro-infusion pump for each coordinate (2×300 nL for dDG and 2×300 nL for BLA) (UMP3; World Precision Instruments). After injection was complete ...
-
bioRxiv - Developmental Biology 2021Quote: ... The microelectrode and a reference electrode (WPI, DRIREF-2) were then mounted onto the micromanipulator (Narishige MO-202D ...
-
bioRxiv - Neuroscience 2023Quote: ... A 2 MΩ tungsten electrode (World Precision Instruments, TM33A20) driven by a Sutter manipulator was inserted into the depth of TG (around 5 - 6 mm below brain surface) ...
-
bioRxiv - Neuroscience 2023Quote: ... and 35G NanoFil beveled needle (WPI; Catalog# NF35BV-2). The volume of AAVs was 500-1000 nL at the rate 50-100 nL per minute ...
-
bioRxiv - Neuroscience 2023Quote: ... fit with a 36G beveled needle (NF36BV-2, WPI). A high-titre solution of viral vector (AAV9-syn-jGCaMP7f-WPRE ...
-
bioRxiv - Neuroscience 2023Quote: ... electrolytic lesions of 10 μA during 5 s(Stimulus Isolator, WPI) to identify electrode bundle tip location were performed prior to PFA perfusions ...
-
bioRxiv - Neuroscience 2023Quote: ... the 5-V trigger is sent to a picopump (WPI, PV830) connected to a 2-mm diameter plastic tube that terminates in a glass capillary to deliver pressurized air to the mouse whiskers.
-
bioRxiv - Neuroscience 2021Quote: ... ACSF or 6-OHDA solution were loaded to a 10 µl NanoFil syringe (World Precision Instruments Inc., Sarasota, FL, USA) with a 35G blunt needle ...
-
bioRxiv - Neuroscience 2021Quote: ... Stimulation pipettes were made from 1.50 OD/1.02 ID thick septum theta borosilicate glass capillaries (TST150-6; World Precision Instruments) using a P-97 micropipette puller and filled with ACSF ...
-
bioRxiv - Molecular Biology 2022Quote: ... Patch recording pipettes (4-6 MΩ) were pulled from thin-walled borosilicate capillary glass (World Precision Instruments [WPI], Sarasota, FL) on a P-2000 laser electrode puller (Sutter Instrument ...
-
bioRxiv - Molecular Biology 2022Quote: ... Patch recording pipettes (4-6 MΩ) were pulled from thin-walled borosilicate capillary glass (World Precision Instruments [WPI], Sarasota, FL) on a P-2000 laser electrode puller (Sutter Instrument ...
-
bioRxiv - Neuroscience 2023Quote: ... and muscle cells were patched using fire-polished 4–6 MΩ resistant borosilicate pipettes (1B100F-4, World Precision Instruments, USA). Membrane currents were recorded in the whole-cell configuration by PULSE software with a HEKA EPC-9 amplifier (Germany) ...
-
bioRxiv - Bioengineering 2020Quote: ... 2×104 sGFP sender and 2×104 αGFP receiver cells were seeded into 35-mm FluoroDish Cell Culture Dishes (World Precision Instruments, FD35-100) and immediately imaged under a DeltaVision OMX (GE Healthcare ...
-
bioRxiv - Neuroscience 2019Quote: ... A Nanofil 33-gauge needle (World Precision Instruments, #NF33BV-2) was inserted into the brain and the virus was injected at a rate of 25 nl/min using Microsyringe Pump (World Precision Instruments ...
-
bioRxiv - Neuroscience 2022Quote: ... through a 33G beveled needle (World Precision Instruments, # NF33BV-2), controlled by a micro-syringe pump (World Precision Instruments ...
-
Social Regulation of Egg Size Plasticity in the Honey Bee is Mediated by Cytoskeleton Organizer Rho1bioRxiv - Evolutionary Biology 2022Quote: ... coupled with a 35G needle (NF35BV-2; World Precision Instruments). Injected queens were given time to recover and placed back into their original colonies ...
-
bioRxiv - Neuroscience 2021Quote: ... with a 33-gage beveled Nanofil needle (NF33BV-2, WPI). The syringe was mounted into a motorized microinjector (UMP3T-2 ...
-
bioRxiv - Neuroscience 2022Quote: ... and a microinjection syringe pump (UMP3T-2 World Precision Instruments). Animals received 250 µL of saline for post-surgery hydration.
-
bioRxiv - Neuroscience 2023Quote: ... a Nanofil 33-gauge needle (World Precision Instruments, #NF33BV-2) was slowly inserted into the CA1 region (AP ...
-
bioRxiv - Neuroscience 2023Quote: ... Females: scaled*0.95) using a 33g needle (NF33BV-2, WPI). During the same surgery ...
-
bioRxiv - Neuroscience 2022Quote: ... Patch pipettes with a resistance of 4–6 MΩ were pulled from borosilicate glass capillaries (1.5 mm outer diameter, 0.86 mm internal diameter, World Precision Instruments, USA) using a micropipette puller (PC-10 ...
-
bioRxiv - Neuroscience 2022Quote: ... 400 nl of BDA were injected at a rate of 80 nl/min and a depth of 0.7 mm into each of 6 injection sites with a microinjector (WPI, Nanoliter 2010) using the fine glass pipets ...
-
bioRxiv - Cell Biology 2022Quote: ... Lipids were hydrated for 15 min with buffer (PBS) and SMTs were generated by injecting PBS into the chamber using an Aladdin Single-Syringe Pump (World Precision Instruments, model n°. AL-1000) at a flow rate of 1,5 mL/min for 5 min ...
-
bioRxiv - Cell Biology 2024Quote: ... Lipids were hydrated for 15 min with buffer (PBS) and SMTs were generated by injecting PBS into the chamber using an Aladdin Single-Syringe Pump (World Precision Instruments, model n°. AL-1000) at a flow rate of 1,5 mL/min for 5 min ...
-
bioRxiv - Physiology 2021Quote: ... juncea leaves with 100 nL ultra pure water containing 100 ng of dsIMPI or each 100 ng of dsPaGTR5/6/7/8 using a Nanoliter 2010 Injector (World Precision Instruments). A subset of the dsRNA-injected beetles were fed with detached leaves of Arabidopsis plants in plastic containers with moistened tissue for gene expression analysis (n = 6 replicates ...
-
bioRxiv - Neuroscience 2020Quote: ... 500 mM sucrose was applied directly on the dendritic field of the patched neurons at a puff pressure of 6–8 psi using a PV-820 Pneumatic Picopump system (World Precision Instruments). Receptor-mediated synaptic responses were pharmacologically isolated by applying drug combinations of 50 µM picrotoxin ...
-
bioRxiv - Neuroscience 2022Quote: ... Oocytes were injected with 38.6 nL of Bgl-FaNaC encoding RNA at a concentration of 20 ng/uL using a Nanoliter 2000 microinjector (World Precision Instruments). Maximum expression levels were observed 6 days following injection.