Labshake search
Citations for World Precision Instruments :
151 - 200 of 505 citations for 6 Chloro 2 3 diphenylimidazo 1 2 b pyridazine since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2023Quote: ... 1-3% maintenance) and body temperature was maintained at 37.5°C using a temperature controller (ATC2000, World Precision Instruments). Animals were dosed with slow-release buprenorphine (0.1mg/kg ...
-
bioRxiv - Plant Biology 2023Quote: ... Borosilicate glass capillaries (1B150F-6, World Precision Instruments, Sarasota, USA) were used to make micropipettes with the use of a P-30 micropipette puller (Shutter Instrument Co. ...
-
bioRxiv - Neuroscience 2020Quote: Test compounds were dissolved in aCSF and locally puff-applied with a patch pipette (4–6 MΩ) at low pressure (∼1 psi) controlled by a Pneumatic Picopump (PV821, World Precision Instruments, USA) for 20 to 90s ...
-
bioRxiv - Neuroscience 2020Quote: ... with a 33-G beveled needle that was mounted into a motorized microinjector (Legato130, KD Scientific or UMP3T-2, WPI, Sarasota, FL, USA). Other surgical procedures and viral injection was as described previously (15).
-
bioRxiv - Neuroscience 2020Quote: ... at a rate of 0.2 μL/min with a glass micropipette connected to a Hamilton syringe controlled by stereotaxic syringe holder (SYS-Micro4, WPI, Sarasota, FL, USA). The needle was removed 10 min later ...
-
bioRxiv - Molecular Biology 2023Quote: The trans-epithelial electric resistance (TEER) was tracked using the EVOM voltohmmeter equipped with STX-2 chopstick electrodes (World Precision Instruments, Stevenage, UK) during wet (days −3 ...
-
bioRxiv - Neuroscience 2023Quote: ... fluoxetine was intracranially delivered with a volume of 58.7 nl/side over 2 min using a motorized single pressure syringe pump (World Precision Instruments, Sarasota, FL). After infusion ...
-
bioRxiv - Cancer Biology 2023Quote: ... a custom-made EEG adapter with attached wires (2 recording channels, one reference, each made from Teflon-coated silver (WPI, Sarasota, FL, USA) wire with ∼0.5mm tips exposed ...
-
bioRxiv - Bioengineering 2023Quote: ... Pupils were dilated and sub-retinal injections of 2 µL were performed using a Nanofil syringe with a 28-gauge blunt needle (World Precision Instruments, Inc.) under an operating microscope (Leica Microsystems ...
-
bioRxiv - Neuroscience 2020Quote: ... Current pulses were delivered via a constant current source (model 305-B, World Precision Instruments). A stimulus generator (A310 Accupulser ...
-
bioRxiv - Neuroscience 2023Quote: ... Recordings were performed with low resistance (1–3 MΩ) glass pipettes (ID: 0.68 mm, OD: 1.2 mm, WPI, Sarasota, FL) filled with aCSF under current-clamp mode with I=0 configuration ...
-
bioRxiv - Developmental Biology 2022Quote: ... glass capillaries (World Precision Instruments TW100-3) were pulled using a P-97 Flaming Brown needle puller (Sutter Instrument ...
-
bioRxiv - Neuroscience 2023Quote: ... Glass capillaries (WPI, cat. No. 1B100-3) coated with a drop of heparin (50U/ml ...
-
bioRxiv - Neuroscience 2023Quote: ... Using an UltraMicroPump 3 (World Precision Instruments), 5.5 μg of Rho-BR-EVs were injected into the lateral ventricle at a 1 μl/min rate ...
-
bioRxiv - Developmental Biology 2023Quote: ... glass capillaries (World Precision Instruments TW100-3) are pulled using a P-97 Flaming Brown needle puller (Sutter Instrument ...
-
bioRxiv - Cell Biology 2021Quote: ... Transendothelial electrical resistance (TER) was measured daily using an EVOM volt ohm meter equipped with STX-2 electrodes (World Precision Instruments, Sarasota, FL, USA) and electrical resistance calculated as previously described (Bartosova et al. ...
-
Validating Minimally Invasive Laser Doppler Flowmetry for Serial Bone Perfusion Measurements in MicebioRxiv - Bioengineering 2019Quote: ... was placed directly on the exposed bone surface (Fig. 2) and held in place using a micromanipulator (MM3-ALL, World Precision Instruments, Sarasota, FL) to reduce signal noise from probe movement ...
-
bioRxiv - Neuroscience 2020Quote: Extracellular single-unit recordings confined to superficial cerebellar cortical layers were obtained in the awake animal during the reaching task using either parylene-insulated tungsten microelectrodes (WPI, impedance 2-5 MΩ) or a 16 channel Vector Array microelectrode (Neuronexus ...
-
bioRxiv - Neuroscience 2021Quote: ... The pipette was filled from the back end with mineral oil and attached to a syringe needle mounted in a microinjection syringe pump (World Precision Instruments, UMP3T-2). Before injection ...
-
bioRxiv - Neuroscience 2022Quote: ... with a Gamry 600+ potentiostat (Gamry Instruments, Warminster, PA) (N=2 arrays) using previously published methods89.Silver ground and reference wires (AGT05100, World Precision Instruments, Sarasota, FL) were soldered to the PCB ...
-
bioRxiv - Neuroscience 2023Quote: ... the vagus nerve was mechanically stabilized on the micro-cuff electrode by applying a drop of 2-component silicone (Kwik-Sil, World Precision Instruments, Sarasota, FL) and then sectioned either caudal or rostral to the cuff ...
-
bioRxiv - Neuroscience 2023Quote: ... Infusions were made at a rate of 100 nL/min utilizing 29 Ga microinjection needles connected to FEP tubing secured to a 2 µl Hamilton syringe and a microinjection pump (UMP3, World Precision Instruments, Sarasota, FL). The infusion system was filled with distilled water and separated from the infused virus or drug by a small air bubble ...
-
bioRxiv - Neuroscience 2024Quote: ... the stock solution was further diluted to 0.6 mM with saline and 2 µl of the diluted solution was intracerebroventricularly administered after the control recording sessions using a NANOFIL micro-syringe (World Precision Instruments; FL, U.S.A.) and ultra-micro pomp (UMP3T-1 ...
-
bioRxiv - Cell Biology 2019Quote: ... loose chromosome was grabbed by the force pipette (WPI TW100F-6), moved from the bundle and grabbed with the pulling pipette on the other end ...
-
bioRxiv - Neuroscience 2019Quote: Field EPSPs (fEPSPs) were recorded as previously (19) in CA1 stratum radiatum with glass electrodes (1–3 MΩ; WPI, Saratosa, FL) filled with ASCF ...
-
bioRxiv - Microbiology 2022Quote: Consumption of O2 was measured using an ISO-OXY-2 O2 sensor attached to an APOLLO 4000 free radical analyzer (World Precision Instruments, Inc., Sarasota, FL) as described52 ...
-
bioRxiv - Neuroscience 2019Quote: ... The muscle temporalis was detached from the skull and a 4×2 mm craniotomy was performed using a dental drill (World Precision Instruments, Omnidrill3, tip #7), following the contour delimited rostral and ventrally by the squamosal suture ...
-
bioRxiv - Neuroscience 2022Quote: Whole cell patch clamp was performed on interneurons from the lumbar segments using 2–4 MΩ glass electrodes pulled from glass capillary tubes (Item #TW150F-4, World Precision Instruments, Sarasota, FL, USA) with a Flaming-Brown P-97 (Sutter Instrument Company ...
-
bioRxiv - Neuroscience 2023Quote: ... The space between the edges of the foil and the head capsule of the fly was sealed with 2-component silicon (Kwik-Sil™, World Precision Instruments, Sarasota, USA). A droplet of Ringer’s solution (NaCl ...
-
bioRxiv - Neuroscience 2023Quote: ... The virus (AAV1/2-OXTp-hM4Dgi-mCherry or AAV1/2-OXTp-Venus or AAV1/2-OXTp-mCherry) was loaded into a 20μl NanoFil syringe fitted with a 33gauge needle (cat no. NF33BL, World Precision Instruments Inc, Sarasota, FL, USA). A final volume of 270nl was injected into the PVH (A-P −1.7mm ...
-
bioRxiv - Biochemistry 2024Quote: ... Snails were injected using glass capillary needles (World Precision Instruments, 1B100F-6) pulled to an opening size of approximately 100 µm with a Model P-87 Sutter Instrument Micropipette Puller ...
-
bioRxiv - Neuroscience 2020Quote: ... through a micropipette (World Precision Instruments, TW150-3) and applying gentle mechanical force ...
-
bioRxiv - Physiology 2020Quote: ... and audible baseline monitor (model ABM-3, WPI) as previously described27 ...
-
bioRxiv - Cancer Biology 2023Quote: ... Filamented glass needles (TW100F-3, World Precision Instruments) pulled with a P-97 Flaming/Brown micropipette puller (Sutter Instrument ...
-
bioRxiv - Neuroscience 2019Quote: ... Papaverine was locally ejected for ~1 s by 3 times using an air pressure of <15 psi in the pipette (PV830 Pneumatic PicoPump, World Precision Instruments). A red cloud (Alexa 594 ...
-
bioRxiv - Neuroscience 2020Quote: ... Extracellular field potentials from de CA1 pyramidal neurons were recorded using a borosilicate glass micropipette (1–3 MΩ; RRID:SCR_008593; World Precision Instruments, Sarasota, US) filled with aCSF positioned on the slice surface in the stratum radiatum of CA1 and connected to the headstage of an extracellular recording amplifier (NeuroLog System ...
-
bioRxiv - Biophysics 2021Quote: ... to block or enhance a specific pathway the ear surface was gently cleaned and dried and a 4 µl solution containing a selected drug (Table 2) diluted in a PBS was microinjected in the earlobe skin using a 10 µl NANOFIL syringe (World Precision Instruments Inc., Sarasota, FL, USA) equipped with a gauge 33 needle ...
-
bioRxiv - Neuroscience 2020Quote: ... A craniotomy was made over the right visual cortex (3 to 4.5 mm in diameter) and viruses were injected with a micropump (UMP-3, World Precision Instruments) at a rate of 2 nl/s ...
-
bioRxiv - Neuroscience 2020Quote: ... a craniotomy was made over the right visual cortex (3 to 4.5 mm in diameter) and viruses were injected with a micropump (UMP-3, World Precision Instruments) at a rate of 2 nl/s ...
-
bioRxiv - Neuroscience 2020Quote: ... Row B barrels were injected with viral vectors (40 nl/barrel) using a nanoliter injector (Nanoliter 2010, WPI) ended with a glass capillary backfilled with paraffin oil (catalog ...
-
bioRxiv - Neuroscience 2019Quote: ... filled with normal ACSF) using a DAM-80 amplifier (low filter, 1 Hz; high pass filter, 3 KHz; World Precision Instruments, Sarasota, FL). Mossy fiber-mediated fEPSP were evoked by weak electrical stimulations performed via a bipolar NiCh electrode (NI-0.7F ...
-
bioRxiv - Neuroscience 2022Quote: ... between two custom-made suction electrodes (1.5 mm, #1B150-6, World Precision Instruments) and kept superfused with artificial cerebrospinal fluid (aCSF) ...
-
bioRxiv - Neuroscience 2023Quote: ... These were pulled from TW150F-6 micropipettes (World Precision Instruments Inc., Sarasota, FL) on a horizontal Flaming/Brown micropipette puller (Model P-87 ...
-
bioRxiv - Biophysics 2023Quote: ... Thin-wall capillaries (TW150F-3, World Precision Instruments, Germany) were pulled with a DMZ-universal puller (Zeitz ...
-
bioRxiv - Bioengineering 2023Quote: ... Using a microinjection pump (UMP-3; World Precision Instruments), 0.2⨉106 D425-GL cells were injected in a volume of 3 μL at 30 nL/s ...
-
bioRxiv - Animal Behavior and Cognition 2022Quote: ... We accomplished this by having Varroa feed on pupae in which 3 μl of 1×107 DAPI microspheres in PBS buffer was injected (31 gauge needle, Micro4 microsyringe pump controller (World Precision Instruments, Sarasota, FL). A second group of pupae which served as a control were injected with PBS ...
-
bioRxiv - Neuroscience 2023Quote: ... Recording electrodes of 4-6 MΩ were pulled from borosilicate glass (WPI 1B150F-4) with a vertical puller (Narishige P-10) ...
-
bioRxiv - Bioengineering 2021Quote: ... Pulled glass capillaries (TW120-3, World Precision Instruments, Sarasota, FL) were made using a glass puller and filament (P-97 and FB315B ...
-
bioRxiv - Biophysics 2020Quote: ... Recording pipettes were fabricated from the TW150-6 borosilicate glass capillaries (World Precision Instruments Inc.) using the pp830 vertical puller (Narishige International) ...
-
bioRxiv - Neuroscience 2021Quote: ... 4-6 MOhm pipettes were prepared from borosilicate glass capillaries (PG10165-4, World Precision Instruments) in a vertical puller (PIP 6 ...