Labshake search
Citations for World Precision Instruments :
351 - 400 of 590 citations for 6 Bromo 3 4 dihydro 2H 1 benzothiin 4 one since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Neuroscience 2019Quote: ... and using thin wall glass pipettes (1.5-3 MΩ, World Precision Instruments, Sarasota, FL, USA) filled with internal solution containing the following in mM ...
-
bioRxiv - Biophysics 2020Quote: ... Patch pipettes were pulled from borosilicate glass tubes (TW150F-3; World Precision Instruments, Berlin, Germany) to give a resistance of about 3 MΩ ...
-
bioRxiv - Bioengineering 2021Quote: ... access ports were opened using a 3-mm biopsy punch (ref. 504649, World Precision Instruments).
-
bioRxiv - Neuroscience 2022Quote: ... Patch pipettes with a resistance between 3-5 MΩ were pulled from borosilicate glass (WPI) with a Sutter-87 puller (Sutter) ...
-
bioRxiv - Neuroscience 2023Quote: ... gas-tight Hamilton syringe controlled by a Micro4 Ultra Microsyringe Pump 3 (World Precision Instruments) into the nucleus accumbens core (AP ...
-
bioRxiv - Neuroscience 2023Quote: ... gas-tight Hamilton syringe controlled by a Micro4 Ultra Microsyringe Pump 3 (World Precision Instruments). The needle was left in place for 10 minutes following the infusion to allow for diffusion of the virus from the injection site ...
-
bioRxiv - Neuroscience 2024Quote: ... The patch pipettes (2.5 – 3.5 MΩ) were fabricated from borosilicate glass tubes (WPI, 1B150F-3) using a horizontal puller ...
-
bioRxiv - Neuroscience 2022Quote: ... 400 nl of BDA were injected at a rate of 80 nl/min and a depth of 0.7 mm into each of 6 injection sites with a microinjector (WPI, Nanoliter 2010) using the fine glass pipets ...
-
bioRxiv - Neuroscience 2020Quote: ... The pulses repeated at 3 Hz for 10 s) by using a stimulus isolator (A365, WPI). The stimulation duration and frequency were triggered directly through the MRI scanner which controlled by Master-9 A.M.P.I system (Jerusalem ...
-
bioRxiv - Developmental Biology 2021Quote: ... Cells were patched using fire-polished 3–7 MΩ resistant borosilicate pipettes (World Precision Instruments, USA) and membrane currents and voltages were recorded in the whole-cell conFIGuration by a Digidata 1440A and a MultiClamp 700A amplifier ...
-
bioRxiv - Neuroscience 2023Quote: ... was then injected through a thin glass pipette with a micropump (UMP-3, World Precision Instruments). After injection ...
-
bioRxiv - Physiology 2021Quote: ... juncea leaves with 100 nL ultra pure water containing 100 ng of dsIMPI or each 100 ng of dsPaGTR5/6/7/8 using a Nanoliter 2010 Injector (World Precision Instruments). A subset of the dsRNA-injected beetles were fed with detached leaves of Arabidopsis plants in plastic containers with moistened tissue for gene expression analysis (n = 6 replicates ...
-
bioRxiv - Neuroscience 2020Quote: ... 500 mM sucrose was applied directly on the dendritic field of the patched neurons at a puff pressure of 6–8 psi using a PV-820 Pneumatic Picopump system (World Precision Instruments). Receptor-mediated synaptic responses were pharmacologically isolated by applying drug combinations of 50 µM picrotoxin ...
-
bioRxiv - Neuroscience 2022Quote: ... Oocytes were injected with 38.6 nL of Bgl-FaNaC encoding RNA at a concentration of 20 ng/uL using a Nanoliter 2000 microinjector (World Precision Instruments). Maximum expression levels were observed 6 days following injection.
-
bioRxiv - Neuroscience 2023Quote: ... The virus solution (0.4-0.6 µL) was injected at a rate of 2 nL/s with a microinjection pump (either Neurostar NanoW or WPI NanoLiter 2010). The pipette was slowly withdrawn at least 10 minutes after the completion of the injection ...
-
bioRxiv - Neuroscience 2019Quote: ... was connected to a pneumatic injector (3–20 PSI, 10–90 s; Pneumatic Pump; World Precision Instruments). This set-up was used to load the somatosensory cortex with the Ca2+-sensitive dye Oregon Green Bapta (OGB-AM ...
-
bioRxiv - Neuroscience 2022Quote: ... which was positioned over the peroneal nerve using a 3-axis micromanipulator (KITE-R, World Precision Instruments). The micromanipulator was secured to an optical breadboard (MB1218 ...
-
bioRxiv - Pathology 2021Quote: ... body temperatures were measured using a thermocouple thermometer and mouse rectal probe (World Precision Instruments, RET-3). Blood glucose measurements were obtained with 2uL of tail vein blood analyzed with a Bayer CONTOUR Blood Glucose Monitor and Test Strips ...
-
bioRxiv - Neuroscience 2023Quote: ... mice were anesthetized with 3% isoflurane (Henry Schein) and transferred to a stereotaxic apparatus (World Precision Instruments). One burr hole was drilled above the left hippocampus (−2 mm anterior-posterior [A-P] to Bregma ...
-
bioRxiv - Neuroscience 2023Quote: ... 400nl of virus was delivered to 3 locations respectively by a microinjection system (Nanoliter 2010, WPI Ltd) through a craniotomy (<1 mm2) ...
-
bioRxiv - Genetics 2022Quote: ... The recording electrodes were HEPES-buffered extracellular saline-filled glass micropipettes (type 1B100F-3, World Precision Instruments) pulled with a Sutter P-87 micropipette puller ...
-
bioRxiv - Neuroscience 2023Quote: ... The electrode tip was filled to 2-3 mm with K+ ionophore solution (IE190, World Precision Instruments) by capillary action ...
-
bioRxiv - Neuroscience 2023Quote: ... was injected at each site through a glass pipette and microsyringe pump (UMP-3, World Precision Instruments). After allowing at least ten minutes for viral diffusion ...
-
bioRxiv - Neuroscience 2020Quote: ... individual 7 µm diameter carbon fibres (Goodfellow Cambridge Limited, Cambridge, UK) were bundled and introduced into a pulled double borosilicate capillary (WPI, ref. TST150-6”) with ≃ 200 µm tip diameter and electrical impedance of 40-65 kΩ ...
-
bioRxiv - Neuroscience 2020Quote: ... 3 mm deep of dura mater) using a 36-gauge beveled needle (World Precision Instruments, Sarasota, FL, USA). A vehicle solution consisting of 0.1% BSA in PBS was injected into the contralateral striatum of the same mice ...
-
bioRxiv - Neuroscience 2021Quote: ... The recording electrodes were typically 3-5 MΩ size and were pulled from borosilicate glass (World Precision Instruments). The intracellular solution used had the following composition (in mM) ...
-
bioRxiv - Neuroscience 2021Quote: ... Patch pipettes having a resistance of 4–6 MΩ were fabricated from thin-wall glass capillaries (1.5 mm o.d./1.12 mm i.d., TW150F-3, World Precision Instruments). The internal patch pipette solution used for voltage-clamp recordings contained the following (in mM) ...
-
bioRxiv - Neuroscience 2022Quote: ... mice were anesthetized with 3% isoflurane (Henry Schein) and then transferred to a stereotaxic apparatus (World Precision Instruments). One burr hole was drilled above the left hippocampus (—2mm anterior-posterior (A-P ...
-
bioRxiv - Neuroscience 2023Quote: ... A patch pipette was pulled from a thin-wall glass capillary (1.5 mm o.d./ 1.12 mm i.d., TW150F-3, World Precision Instruments). Resistance of the pipette was typically 8-10 MΩ ...
-
bioRxiv - Neuroscience 2022Quote: ... attached to a 3 mm diameter large and 1.2 mm height cannula (Microgroup INC) with Kwik-Sil adhesive (WPI) and fixed the edge of the glass with cyanoacrylate ...
-
bioRxiv - Neuroscience 2020Quote: ... Recording patch pipettes (3-7 MΩ) were fabricated from standard-wall borosilicate glass capillary with filament (World Precision Instruments). Intracellular solution for DA PSC recording was (in mM) ...
-
bioRxiv - Neuroscience 2022Quote: ... were carried out with Nanofil 10 μL syringe and UMP-3 controller attached to it (World Precision Instruments, Inc.).
-
bioRxiv - Neuroscience 2022Quote: ... Electric signals from motor neuron axons in the tail were recorded using borosilicate pipettes (TW150-3, World Precision Instruments) pulled by a horizontal puller (P-1000 ...
-
bioRxiv - Neuroscience 2023Quote: Whole-cell patch-clamp recordings were obtained from NAc shell MSNs using borosilicate glass pipettes (3-5 ΩM; WPI) filled with intracellular solution containing (in mM) ...
-
bioRxiv - Neuroscience 2022Quote: ... Warner Instrument) attached to a 3 mm-diameter and 1.2 mm-high cannula (Microgroup INC) using KwikSil adhesive (WPI). The edge of the cannula was fixed to the skull with cyanoacrylate ...
-
bioRxiv - Neuroscience 2022Quote: ... ABRs were band-pass filtered (0.3–3 kHz, ×20,000 gain) using analog filters/amplifiers (ISO-80, World Precision Instruments, Sarasota ...
-
bioRxiv - Neuroscience 2022Quote: ... patch pipettes with a resistance of 3~5 MΩ were made from borosilicate glass (World Precision Instruments, Sarasota, FL) with a Sutter Instrument P-97 micropipette puller (Novato ...
-
bioRxiv - Neuroscience 2023Quote: ... Item# WE30030.5A5) with 2-3 µm diameter and 0.5 MΩ impedance connected to DAM50 Extracellular Amplifier (World Precision Instruments); data were acquired with Clampex 10.7 (Molecular Devices) ...
-
bioRxiv - Microbiology 2021Quote: ... cRNA was micro-injected into stage 5 or 6 oocytes using a Micro4TM micro-syringe pump controller and A203XVY nanoliter injector (World Precision Instruments, Sarasota, FLA, U.S.A.). Oocytes were maintained in oocyte Ringer’s buffer with added gentamycin (50 μg/ml ...
-
bioRxiv - Physiology 2021Quote: Pronuclei of one-cell stage embryos were collected from superovulated donor females (B6/SJL strain) and microinjected with CRISPR/Cas9 constructs using micromanipulators and injection needles (World Precision Instruments, filament #1B100-6). Injected embryos were implanted into pseudopregnant recipient females according to NIH guidelines ...
-
bioRxiv - Neuroscience 2021Quote: ... The recording glass electrode (thin-wall glass capillaries; OD, 1.0 mm; length, 76 mm; World Precision Instruments, cat. # TW100F-3) was pulled using a micropipette puller (Sutter Instrument ...
-
bioRxiv - Neuroscience 2020Quote: ... Viral suspensions were loaded in beveled glass capillaries (tip diameter: 15-30 µm) and injected with a micropump (UMP-3, WPI) at a rate of 20-30 nl/minute into the parenchyma ...
-
bioRxiv - Neuroscience 2022Quote: ... was left in place for 3 and 5 min after the first and second injections (100-nl/min, UMP3 electrical pump, WPI) to prevent backflow of the injected virus solution ...
-
bioRxiv - Neuroscience 2023Quote: ... 30–120 nl of virus were injected at a rate of 3 nl/s at two depths (0.1 mm and 0.2 mm ventral/below pia) using a microsyringe pump (UMP-3, World Precision Instruments).
-
bioRxiv - Genetics 2020Quote: ... Glass needles for zebrafish eggs injections were prepared from glass capillary tubes with filament (ø1 mm × 90 mm) (WPI #1B100F-3) using a NARISHIGE dual-stage micropipette puller PC-10 machine ...
-
bioRxiv - Biophysics 2020Quote: ... were collected by centrifugation for 3 min at 180 RCF and seeded onto glass bottom dishes (fluorodish; #FD35100, WPI, FL, USA) in CO2-independent medium (#18045-054 ...
-
bioRxiv - Neuroscience 2020Quote: ... Germany) and Pulse 8.11 software as described previously.3 Patch pipettes were pulled from borosilicate glass tubing (World Precision Instruments, Germany). The signals were filtered using an eight-pole Bessel filter built into the EPC-9 amplifier and digitized at a frequency ≥ filter cut-off frequency (VR-10B ...
-
bioRxiv - Neuroscience 2022Quote: ... The tip of the pipette was cut to an opening diameter of ∼3 μm and bent to ∼40° using a microforge (WPI, DMF1000). Tethers were pulled with a 4 µm diameter polystyrene bead (Spherotech #DIGP-40-2 ...
-
bioRxiv - Neuroscience 2022Quote: ... We sealed the craniotomy with silicone gel (Dow DOWSIL 3-4680, sometimes called “artificial dura”) and a silicone sealant (WPI KwikCast). We also implanted a stainless steel pin elsewhere on the dorsal surface of the skull ...
-
bioRxiv - Developmental Biology 2024Quote: Erythrocytes were isolated from 3-dpf zebrafish embryos (wild-type and miR-144Δ/Δ) by dissecting their tail using sapphire blade (WPI) and collecting cells in the bleeding buffer (1X PBS containing 2% PBS and 5 mM EDTA) ...