Labshake search
Citations for World Precision Instruments :
151 - 200 of 687 citations for 6 BROMO 4 4 DIMETHYL 1H BENZO D 1 3 OXAZINE 2 4H THIONE since 2019
Citations are collected from bioRxiv only, the total number of publications could be much larger.
-
bioRxiv - Physiology 2022Quote: ... Glass pipette tips were created from glass rods (World Precision Instruments, Inc., 1B120F-4) using a Narshige pipette puller (Model PC-100 ...
-
bioRxiv - Neuroscience 2021Quote: ... Borosilicate glass capillary tubes (Kwik-Fil 1B150F-4, World Precision Instruments, Hitchin, United Kingdom) were pulled using a Model P90 micropipette puller (Sutter instruments ...
-
bioRxiv - Neuroscience 2022Quote: ... Before activating the micropump (MicroSyringe Pump Controller, Micro 4 ™, World Precision Instruments, Inc.) for the injection ...
-
bioRxiv - Neuroscience 2023Quote: Thick-walled borosilicate glass pipettes (World Precision Instruments; Sarasota, Fl, USA; Cat# 1B150F-4) were pulled using a Narishige PP-830 electrode puller (Tokyo ...
-
bioRxiv - Neuroscience 2023Quote: ... Neurons were patched using ∼20 MΩ-resistant borosilicate pipettes (1B100F-4; World Precision Instruments). Pipettes were pulled by micropipette puller P-1000 (Sutter ...
-
bioRxiv - Neuroscience 2023Quote: ... patch pipettes were pulled from borosilicate glass capillary tubes (TW150-4; World Precision Instruments) using a PC-10 pipette puller (Narishige) ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch pipettes were fabricated from borosilicate glass capillaries (1B150F-4, World Precision Instruments, USA) on a micropipette puller (P-97 Sutter Instrument ...
-
bioRxiv - Neuroscience 2023Quote: ... Patch pipettes were pulled from borosilicate glass (1B120F-4; World Precision Instruments, Sarasota, FL) on a P-97 Sutter Instruments puller (Novato ...
-
bioRxiv - Neuroscience 2024Quote: ... was placed partially inside a capillary tube (#1B120F-4; World Precision Instruments; Sarasota, FL) and then saturated with tastant ...
-
bioRxiv - Physiology 2024Quote: ... The circuit was completed with a thinly pulled borosilicate glass electrode (1B200F-4, WPI) filled with 500 mM KCl ...
-
bioRxiv - Neuroscience 2021Quote: ... we pulled 6 to 10 M-Ohm glass pipettes made of thick-walled glass (World Precision Instruments 1B150F-3) using a Sutter Instruments P-1000 puller ...
-
bioRxiv - Neuroscience 2021Quote: ... we used four individual samples (exceptions: SST RML 10 WPI: n = 3; PV NBH 10 WPI: n = 3; Astro RML 18 WPI: n = 2). RNA was converted to cDNA using the Transcriptor High Fidelity cDNA Synthesis Kit (Roche Aplied Science) ...
-
bioRxiv - Neuroscience 2020Quote: ... Recording electrodes (4” thin-wall glass capillary tubes; 1.5 OD / 1.12 ID – World Precision Instruments) were made using a P-97 Flaming/Brown™ micropipette puller (Sutter Instruments ...
-
bioRxiv - Neuroscience 2020Quote: ... Electrodes with a resistance of 4-5 MΩ were pulled from borosilicate capillaries (WPI, USA) in a horizontal puller (P1000 ...
-
bioRxiv - Neuroscience 2021Quote: Recording pipettes were pulled from filamented thin-wall borosilicate glass (TW150F-4, World Precision Instruments) and had a resistance of 4-7 MΩ when filled with internal solution (for intrinsic excitability (AP ...
-
bioRxiv - Genetics 2023Quote: ... This mixture was then loaded into a pulled microinjection needle (World Precision Instruments, 1B100F-4). Injected animals were singled onto 6 cm NGMA plates and allowed to produce offspring ...
-
bioRxiv - Neuroscience 2024Quote: Patch electrodes were created from 4in thin wall borosilicate glass (TW150F-4, World Precision Instruments) and pulled with a Narishige Model PC-10 were filled with the following (in mM ...
-
bioRxiv - Neuroscience 2021Quote: ... we used four individual samples (exceptions: SST RML 10 WPI: n = 3; PV NBH 10 WPI: n = 3; Astro RML 18 WPI: n = 2). RNA was converted to cDNA using the Transcriptor High Fidelity cDNA Synthesis Kit (Roche Aplied Science) ...
-
bioRxiv - Neuroscience 2022Quote: ... +2.2 mm ML from bregma) using a MicroSyringe Pump Controller Micro 4 (World Precision Instruments, WPI) at a rate of 30 nl/min ...
-
bioRxiv - Neuroscience 2022Quote: ... +2.2 mm ML from bregma) using a MicroSyringe Pump Controller Micro 4 (World Precision Instruments, WPI) at a rate of 30 nl/min ...
-
bioRxiv - Neuroscience 2020Quote: Pipettes for patch clamp recordings were pulled from borosilicate thin glass capillaries (TW150-4, WPI, USA) and filled with a filtered intracellular solution with the following composition (mM) ...
-
bioRxiv - Neuroscience 2020Quote: ... (4) conduction velocity – A 2.0 MΩ Parylene-coated tungsten metal stimulating electrode (TM33B20, World Precision Instruments) was positioned within the RF of interest ...
-
bioRxiv - Cell Biology 2021Quote: ... the patch pipettes were pulled from borosilicate glass capillary tubes (World Precision Instruments, Cat# TW150-4) using a PC-10 pipette puller (Narishige) ...
-
bioRxiv - Neuroscience 2022Quote: Pipettes filled with 4% LY PBS solution were mounted on a microelectrode holder (WPI, PE MEH710), which was fixed on a 3-D adjustable micromanipulor (Scientifica ...
-
bioRxiv - Physiology 2021Quote: ... Reference electrodes (5-10 megaohms) were pulled using filamented capillaries (1B100F-4, World Precision Instruments, USA) and back-filled with 1 M KCl ...
-
bioRxiv - Neuroscience 2020Quote: ... 4~5 MΩ for whole-cell recording) were pulled from borosilicate capillary glass (World Precision Instruments) with a Stutter P-97 horizontal puller ...
-
bioRxiv - Neuroscience 2021Quote: ... AAV virus was injected with a glass pipette using an infusion pump (Micro 4, WPI, USA). Viruses were injected bilaterally into target brain areas using the following coordinates ...
-
bioRxiv - Neuroscience 2022Quote: ... Glass recording electrodes (outer diameter 1.5 mm, inner diameter 0.84 mm, World Precision Instruments 1B150F-4) were pulled using a vertical puller (Narishige ...
-
bioRxiv - Physiology 2023Quote: ... Patch pipettes were pulled (PC-10, Narashige) from borosilicate glass tubes (TW150F-4, World Precision Instruments) and heat polished at the tip using a microforge (MF-200 ...
-
bioRxiv - Neuroscience 2023Quote: ... mice were initially anesthetized with 4% isoflurane and fixed in a stereotaxic frame (#504926, WPI, Germany) at 2% isoflurane ...
-
bioRxiv - Plant Biology 2023Quote: ... The measured data were acquired by a Lab-Trax-4 device (World Precision Instruments, Sarasota, USA) working with LabScribe2 software ...
-
bioRxiv - Physiology 2023Quote: ... The final injection mix was loaded using a pulled capillary needle (1B100F-4, World Precision Instruments) and injected into the germline of N2 young adults ...
-
bioRxiv - Neuroscience 2023Quote: ... Whole-cell recordings from these cells were obtained with glass pipettes (World Precision Instruments 1B150F-4) filled with a solution containing (in mM ...
-
bioRxiv - Physiology 2024Quote: ... Ion-selective electrodes were fashioned from borosilicate glass (TW150-4; World Precision Instruments, Sarasota, FL, USA), pulled on a Flaming-Brown P-1000 micropipette puller (Sutter Instruments ...
-
bioRxiv - Neuroscience 2020Quote: ... A 3 mm round cover glass (#1, World Precision Instruments) was placed over the exposed ...
-
bioRxiv - Neuroscience 2019Quote: ... A 3 mm glass coverslip (#1 thickness, World Precision Instruments) was glued onto the tube to seal the end that was inserted into the craniotomy ...
-
bioRxiv - Neuroscience 2022Quote: ... A 3 mm glass coverslip (#1 thickness, World Precision Instruments) was glued onto the tube to seal the end that was inserted into the craniotomy ...
-
bioRxiv - Neuroscience 2020Quote: Patch clamp pipettes were pulled from borosilicate capillaries (1B120F-4, World Precision Instruments, Inc., Sarasota, FL, USA) with a horizontal puller (P-87 ...
-
bioRxiv - Biophysics 2019Quote: ... An ACSF-filled glass pipette (opening diameter 10-30 µm, 1B120F-4, World Precision Instruments, Sarasota, FL) was used for Schaffer collateral nerve stimulations ...
-
bioRxiv - Pharmacology and Toxicology 2019Quote: ... Microinjection needles were created from glass capillary tubes (058 mm inner diameter; World Precision Instruments, 1B100F-4) using a pipette puller (Sutter instrument model p-30 ...
-
bioRxiv - Neuroscience 2022Quote: ... and controlled by a micromanipulator connected to a pneumatic picopump (4 psi, World Precision Instruments, SYS-PV820). Constant circulation of aCSF was maintained in the dish during the recording ...
-
Serotonergic Modulation of Spinal Circuitry Restores Motor Function after Chronic Spinal Cord InjurybioRxiv - Neuroscience 2023Quote: ... The junction was secured using 4-0 silk suture and liquid silicone (World Precision Instruments, Kwik-Sil). Note that an additional small incision was made above the cannula-implant site to expose the proximal (or silicone ...
-
bioRxiv - Neuroscience 2023Quote: Patch pipettes with 4.5-6.5 MΩ tip resistance were prepared from borosilicate glass capillaries (TW150F-4, WPI) using micropipette pullers (HEKA PIP 6 and MDI PMP102) ...
-
bioRxiv - Cell Biology 2023Quote: ... Microinjection was performed using borosilicate glass capillaries (4 inches, OD 1.0 mm, World Precision Instruments, FL, USA). 200-250 HeLa cells transfected with si-NC or si-METTL3 at a concentration of 25 nM were injected directly into the middle of the yolk sac of the larva ...
-
bioRxiv - Neuroscience 2023Quote: ... followed by AAV injections using a micro-syringe connected to a micropump (UltraMicroPump 4, WPI surgical instruments), which was lowered into the brain until it reached the DV coordinates (see below for details) ...
-
bioRxiv - Biochemistry 2023Quote: ... The samples were electrosprayed from gold-coated borosilicate glass capillaries Kwik-Fil 1B120F-4 (World Precision Instruments) prepared in-house essentially as described before (49 ...
-
bioRxiv - Developmental Biology 2024Quote: ... with needles pulled using a Model P-1000 Flaming Brown Micropipette Puller (World Precision Instruments, TW100F-4). Needles were cut to yield an injection volume of ∼1nL.
-
bioRxiv - Pharmacology and Toxicology 2019Quote: Micropipettes with a tip resistance of 3–6 MΩ were prepared from 1.2/0.69-mm OD/ID borosilicate glass capillaries (World Precision Instruments, GC-120F-10) using a pipette puller (Sutter Instruments ...
-
bioRxiv - Neuroscience 2023Quote: ... The electrode tip was filled to 2-3 mm with K+ ionophore solution (IE190, World Precision Instruments) by capillary action ...
-
bioRxiv - Neuroscience 2020Quote: ... Recording pipettes (resistance of 4-7 MΩ) were pulled from thick-walled borosilicate glass capillaries (World Precision Instruments) and filled with internal solution (in mM ...